Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures

Similar documents
Global Journal of Engineering Science and Research Management

Study of R161 Refrigerant for Residential Airconditioning

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Energy Efficiency of Air-to-Air Mini Heat Pump

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Investigation of Evaporator Performance with and without Liquid Overfeeding

High Efficiency Heat Pump for Domestic Hot Water Generation

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Low GWP Refrigerants for Air Conditioning Applications

Performance Comparison Of Round Tubes Finned Heat Exchangers And Macro Micro-Channel Heat Exchangers In A Low Capacity Heat Pump

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Experimental and Numerical Study on the Performance of R410A Liquid Recirculation Cycles with and without Ejectors

Extremely Low Refrigerant Charge Beverage Display Cooler Technology Using Propane

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Quantification of Liquid Refrigerant Distribution in Parallel Flow Microchannel Heat Exchanger Using Infrared Thermography

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Performance Measurement of R32 Vapor Injection Heat Pump System

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Dynamic Simulation of Liquid Chillers

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Air-Cooled Heat Exchanger Performance for R410A

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Evaluation of HCFC Alternative Refrigerants

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

TERNARY ZEOTROPIC MIXTURE WITH CO 2 COMPONENT FOR R-22 HEAT PUMP APPLICATION

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental and Numerical Study of a Mobile Reversible Air Conditioning Heat Pump System Charge Imbalance when Switching Modes Paper #2569

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Full and Partial Load Performances of RAC and CAC Heat Pump using R-32

Efficiency of Non-Azeotropic Refrigerant Cycle

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Two-Phase Evaporation Pressure Drop Experimental Results for Low Refrigerant Mass Flux

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

System Modeling of Gas Engine Driven Heat Pump

Heat Exchanger Shelves For Better Temperature Control Of Food In Open-Type Display Cases

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Low GWP Refrigerants for Air Conditioning and Chiller Applications

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

The Circulation Composition Characteristic of the Zeotropic Mixture R1234ze(E)/R32 in a Heat Pump Cycle

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Purdue e-pubs. Purdue University

An Experimental and Theoretical Study on System Performance of Refrigeration Cycle Using Alternative Refrigerants

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Effect of Condenser Subcooling of the Performance of Vapor Compression Systems: Experimental and Numerical Investigation

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

*Corresponding author;

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

2. HEAT EXCHANGERS MESA

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Performance of CO2 Cycles with a Two-Stage Compressor

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

4th IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants 2013

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures Marian Hamdar Ecole des Mines de Paris Assaad Zoughaib Ecole des Mines de Paris Denis F. F. Clodic Ecole des Mines de Paris Follow this and additional works at: http://docs.lib.purdue.edu/iracc Hamdar, Marian; Zoughaib, Assaad; and Clodic, Denis F. F., "Modeling and Design of an Indirect Air Conditioning System Operating With Low GWP Zeotropic Mixtures" (2008). International Refrigeration and Air Conditioning Conference. Paper 938. http://docs.lib.purdue.edu/iracc/938 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2110, Page 1 MODELINGANDDESIGNOFANINDIRECTAIRCONDITIONINGSYSTEMOPERATINGWITHLOW GWPZEOTROPICMIXTURES Marian HAMDAR 1 *, Assaad ZOUGHAIB 2, Denis CLODIC 3 1,2,3 Center of Energy and Processes, Ecole des Mines de Paris, 60, boulevard Saint Michel - 75272 Paris Cedex 06, France 1 Phone: +33-1-40519405, Fax : +33-1-46342491 Email adress: marian.hamdar@ensmp.fr 2 Phone: +33-1-40519466, Fax : +33-1-46342491 Email adress: assaad.zoughaib@ensmp.fr 3 Phone: +33-1-40519249, Fax : +33-1-46342491 Email adress: denis.clodic@ensmp.fr ABSTRACT Indirect air conditioning can be considered as one of the technical options to reduce the refrigerant charge in order to minimize the emissions to the atmosphere. However, indirect systems are less efficient than direct ones due to the additional irreversibilities in the heat exchangers and the power consumption of the pumps. This problem can be overcome by the use of energy efficient heat exchangers with reduced approach temperature (1 K) and the choice of an efficient secondary fluid with evaluated thermo-physical properties. This paper deals with the modeling and design of an indirect air-conditioning system adapted to fluids with temperature glide. A particular attention is paid to the design of the primary and secondary heat exchangers by taking advantage of the mini-channels technology. The optimized heat exchanger presents high thermal efficiency, minimized pressure drop, and compactness over a conventional technology. The energy efficiency of the indirect system is calculated and comparison is carried out with a conventional direct system in order to predict the reduction of equivalent CO 2 emissions. 1. INTRODUCTION The environmental issues related to global warming bring up a new concern over the use of HCFC and HFC refrigerants with high GWP. In the framework of refrigerant substitution, various fluids, for example HCs, HFCs and certain blends of HFCs, which are mostly flammable, are considered as possible candidates. The main concern over using these refrigerants remains however the flammability issue for safety reasons. For mobile refrigeration and air conditioning, flammable alternatives require the use of single or double indirect loops to transport cold/heat via a safe secondary fluid or heat transfer fluid. The flammable or slightly flammable refrigerant is confined into a compact refrigeration loop. The refrigerant charge is reduced and possible leaks into the atmosphere are drastically reduced by the use of full hermetic compressor and a reduction of the number of fittings. The study falls into the context of substitution of a direct expansion air conditioning system, used for a mobile application, by a double indirect one, operating with low GWP zeotropic refrigerant blends. The system is characterized by the introduction of mini-channels technology into the primary heat exchangers. A model has been developed to assist the design of the system components. This paper describes the main characteristics of the model, and particularly the mini-channel heat exchangers models. The results are presented in terms of system efficiency and compactness of the components.

2110, Page 2 2. SYSTEM DESCRIPTION A double indirect air-conditioning system is composed of a primary refrigeration loop and two secondary loops from the evaporator and the condenser (Figure 1). Cold and hot heat transfer fluids (HTF) circulate in the evaporator/condenser loops and transfer heat to and from the refrigerant in the primary heat exchangers. Primary heat exchangers are Refrigerant-to-HTF plate heat exchangers. Secondary heat exchangers are Air-to-HTF parallel flow exchangers. They are referred to as cooler and heater. Cooled air is blown into the temperature control volume and the air blown through the radiator is rejected outdoor. Figure 1: Indirect air-conditioning primary and secondary loops The use of zeotropic refrigerant mixtures may result in improvement of the cycle coefficient of performance. The gain of performance can be illustrated by a comparison of the Carnot and Lorenz cycles. Theoretically, the cycle efficiency can be improved by reducing the temperature difference between refrigerant and heat transfer fluid, by achieving a temperature glide (TG) matching (Mulroy, 1994). The irreversibilities are reduced by maintaining a constant and small temperature difference along the heat transfer. For a specified cooling or heating duty, temperature glide matching with a specified mixture can only be obtained for a single mass flow rate of the heat transfer fluid. Besides its thermodynamic and transport properties, perfect glide matching is difficult to obtain for many zeotropic mixtures (Venkatarathnam, 1996). Unlike single-phase fluids, the refrigerant mixtures can present a non-linear temperature profile with enthalpy variation during phase change. The non-linearity property depends on the mixture composition and on the difference of normal boiling points between the constituents. An inappropriate mixture can result in non-linear temperature profile with a potential to show a pinch point between the two temperature profiles inside the evaporator or the condenser. The last consideration is related to the evaporation and condensation heat transfer coefficients of zeotropic refrigerant mixtures. It is known that the heat transfer coefficient of mixtures is lower than that of pure components, if a linear mixing law is applied (Thome, 1996). All of abovementioned issues show that the thermodynamic process obtained with zeotropes requires special care related to refrigerant selection and heat exchangers design. The required heat transfer areas with zoetropic blends are found to be larger to compensate the smaller temperature difference for TG matching and a possible lower heat transfer coefficient. Micro-channel tube heat exchangers represent an interesting technical option for compactness and heat transfer coefficient enhancement. This technology has been implemented in several industrial applications as automotive air conditioning, electronic cooling, waste heat recovery, etc. In this study, the selected refrigerant is a binary mixture of R-152a and R-32, with respective mass percentage of 80% and 20%. The physical properties of refrigerants are presented in Table 1. The GWP of the mixture is 235.

2110, Page 3 Table 1: Pure components physical properties. Refrigerant Molecular mass (g/mol) NBP Tc 34 Std safety group GWP (100 yr) HFC-152a 66.05-24 113.3 A2 124 HFC -32 52.02-51.7 78.1 A2 675 3. SYSTEM MODELING The indirect system model consists of primary refrigerant-to-htf model, the secondary Air-to-HTF model, and a simple compressor model, based on the manufacturer data. External heat losses through the compressor, the refrigerant pipes, and the HTF pipes are not modeled. Calculation of the refrigerant thermodynamic and transport properties is performed with REFPROP 7.0 subroutines. Additionally, built-in polynomial functions, allow calculating the secondary fluid thermo-physical properties. Component models and physical assumptions are detailed in the following. The heat exchanger zonal models involve mass and energy and momentum conservation equations. The energy equations are simplified by LMTD or -NUT approaches. The exchanger is discretized with a finite volume approach. The continuity of the refrigerant properties is verified in each unitary volume using special functions that check the state of the refrigerant through vapor quality. The set of equations is solved by iterations. Enthalpy and pressure are the variables calculated at the inlet and outlet of the elemental volume. Figure 2 presents a layout of the heat exchanger model. Input data includes the heat exchanger type (primary or secondary), the flow configuration (cross-flow, co-current or counter-current), detailed heat exchanger geometry, and hot and cold flow inlet conditions. The model uses a library of heat transfer and pressure drop models and correlations. Adapted correlations are selected for each operating range and conditions. The model outputs are heat transfer rate, pressure losses, outlet state variables, temperature, pressure and heat transfer coefficients (HTC) variation profiles. The heat exchanger description is saved in an input file. Exchanger geometry P, h i, cold P, h i, hot MFR cold MFR hot HEX type Flow configuration Exchanger Model -NUT DTLM P, h o, cold P, h o, hot Capacity cold, hot DP cold, hot T profile cold, hot HTC profile cold, hot 3.1 Primary heat exchanger correlations Thermal-hydraulic modeling and physical assumptions Figure 2 : Heat Exchanger model inputs and outputs. From the refrigerant side, the primary heat exchanger is designed with an assembly of multiport flat tubes, composed of several micro-channels, for the heat transfer coefficient enhancement. From the HTF side, the pressure drop is reduced by increasing the flow section area of HTF compared to the refrigerant in order to take into account the unbalanced mass flow rates between refrigerant and HTF in the evaporator and the condenser. The prediction of boiling and condensation heat transfer coefficients in micro-channels is a highly studied issue. The experimental investigations have proven that the physical phenomena occurring in micro-scale channels are

2110, Page 4 different from those occurring in macro-scale channels. The differences have been reported to be related to the effects of surface tension, gravity, and phase change mechanisms. The heat transfer coefficients have been predicted through empirical correlations issued from a multitude of experimental data or validated physical models. The different prediction models have been reviewed, compared and discussed in a previous study. Authors Thome et al. (Thome et al. 2004) (Dupont et al. 2004) Table 2: Two-phase heat transfer in mini-channels Evaporation. Channel size/ Correlation Fluid Comparison data: t t film t L dry R-11, R-12, R-113, R-123, htot hl h film hv R-134a, R-141b and CO 2 Refer to Thome et al. D h =0.77-3.1 mm Parameter range G = 50-564 kg/m²s Psat = 1.2-57.6 bar q = 5-178 W/cm² x = 0.01-0.99 Recently, Bertsch et al. (Bertsch et al. 2008) measured boiling heat transfer coefficient of R-134a in a multi-channel evaporator. They presented the results for mass fluxes of 20, 40, 60, and 81 kg/m²s. The heat flux in their experiments varied from 0 to 20 W/cm². Their results are very important because they are representative of the refrigerant flow conditions in refrigeration and heat pumps systems. They observed maximum heat transfer coefficient at vapor quality of 20%. Their experimental results are consistent with Thome et al. (Thome et al. 2004) Being established for large geometry and parameter range database, and several refrigerants, the evaporation model of Thome et al. is selected for the prediction of the evaporation heat transfer coefficient (Table 2). Authors Wang et al. (Wang et al. 2002) Table 3: Two-phase heat transfer in mini-channels Condensation. Channel size/ Correlation Fluid R-134a Nuall f annul Nuannul 1 f annul Nu strat Rectangular multichannels 0.5 1.655 0.6792 0.2208 1.376 8 tt D h = 1.46 mm Nuann 0.0274Prl Rel x 2 tt Nu strat Nu film 1 Nuconv 3 1/ 4 l l v gh fg d h Nu film 0.555 k T T Nu conv 0.023Re l 0.8 l l Pr 0.4 l sat w Parameter range Tsat = 45 66 C x = 0.03-0.94 G=75-750 kg/m²s Cavallini et al. (Cavallini et al. 2006) reviewed the condensation models and correlations for condensation in minichannels. They compared experimental data from heat transfer coefficient measurement of R-134a and R410A (G = 400-1400 kg/m²s, x = 0.25-0.75) inside multi-port channels (Cavallini et al. 2005). They found that, for dimensional gas velocity lower than 2.5, the correlations of Wang et al. (Wang et al. 2002) and Koyoma et al. (Koyoma et al. 2002) can fairly well predict the heat transfer coefficient. For dimensional gas velocity greater than 2.5 (for shear dominated regimes), the Moser et al. model with the Zhang and Webb frictional pressure gradient suits better the heat transfer coefficient data. The tested fluids are pure refrigerants (R-134a, R-123, R-141b..) or nearazeotropic mixtures (R-410A). No data are found for condensation of zeotropic mixtures in mini-channels and the Wang et al. correlation is used in this study (Table 3). 3.2 Compressor and expansion valve modeling The compression process is modeled using isentropic and volumetric efficiency. Adiabatic compression is assumed and thermal losses to the outside environment are neglected. The isentropic and volumetric efficiencies of the compressor are given as polynomial functions of the compression ratio (Equations 1 and 2). They are calculated based on the data provided by the manufacturer as follows: 2 v 0.25 1.33 101.53 (1) 5 4 3 2 is 0.021 0.636 7.603 44.31 120.249 50.6 (2)

2110, Page 5 For a given discharge pressure, the compressor outlet enthalpy is given by Equation 4. The refrigerant mass flow rate is calculated using Equation 3, where D is the displacement rate. D m ref (3) v h h cpr, in h cpr, out, is cpr, in cpr, out hcpr, in (4) is The expansion process of the refrigerant from the high pressure to the low pressure is assumed isenthalpic. Usually the volumetric flow rate through the expansion device is proportional to the differential pressure of the system. In this case, the mass flow rate through the expansion valve is assumed to be equal to that of the compressor. 3.2 Cycle simulation The cycle simulation strategy consists of the following procedures. First, the thermodynamic cycle is calculated with a cycle optimization tool that accounts for the TG matching between the refrigerant and the secondary fluid. The calculation tool is based on the temperature pinch method. In order to reduce irreversibility of the thermodynamic system, the temperature pinch is reduced to 2 K at the microchannel (primary) heat exchangers and to 3 K at the secondary heat exchangers. Inputs of the optimization tool are external air conditions (mass flow rate and temperatures), primary and secondary heat exchangers temperature pinch, and difference of temperatures for superheat and sub-cooling, compressor displacement rate. The cycle is optimized for temperature glide matching at the evaporator and the condenser. For a given required cooling capacity and a calculated refrigerant glide, temperature glide matching between the refrigerant and HTF only occurs only for one HTF mass flow rate. The compressor displacement rate is selected based on the cooling duty of the air-conditioning system. The subroutine allows defining the thermodynamic states of the refrigerant at the inlet and outlet of the heat exchangers and the compressor as well as the secondary fluid conditions. Then, each of the primary and secondary heat exchangers is sized for the calculated operating conditions, in order to satisfy the cooling and heating duties. The sizing includes optimal design of the heat exchangers accounting for compactness of core volume, heat transfer enhancement, and pressure drop reduction. At this step, 4 input files describing geometry, inlet conditions and assumptions of the primary and secondary heat exchangers are generated to perform the calculation of the overall model. At the end, heat exchanger and compressor models are coupled for cycle modeling. The evolution of the thermodynamic system in steady state conditions is based on a convergence criterion of constant superheat and total amount of refrigerant charge. The superheat at the evaporator outlet is controlled by the expansion device. Therefore, for a given refrigerant mass flow rate, the superheat value sets the evaporating pressure. The refrigerant charge inside the system defines the high pressure level. The total refrigerant charge is split into charges calculated at each iteration, in the evaporator, the condenser, and the refrigerant lines. For the calculation of the refrigerant charge in two-phase flow inside the evaporator and the condenser, an appropriate void fraction model has to be selected. The liquid and vapor masses in an heat-exchanger element of length dl and cross sectional area A are related to the void fraction by the following Equations 5 and 6: dcvap V A dl (5) dc A dl ( 1 ) (6) LIQ L In the literature, different void fraction models and correlations have been proposed for the estimation of the void fraction. Newell (Newell et al. 2002) have suggested that homogeneous model is most suitable for intermittent flow regimes where bubbles of vapor travel at the same velocity as the liquid slugs. The void fraction is therefore estimated in the micro-channels exchangers using the homogeneous model given by Equation 7. 1 1 x 1 V (7) x L

2110, Page 6 4. MODELING RESULTS AND DISCUSSION In this section, the micro-channels heat exchangers (MCHE) model and overall indirect model results are presented in terms of efficiency and components design. 4.1 Comparison to experimental data with plate heat exchangers (PHE) The relative gains in compactness, related to the use of MCHE, are highlighted by comparison to the experimental data of Shiba et al. (Shiba et al. 2007). They presented a development study of a high performance water-to-water heat pump. In their data, they attained a cooling COP of 5.5 by improving the heat exchangers technology, the compressor efficiency, and by integrating a liquid-vapor heat exchanger. Plate heat exchangers with external dimensions 529x268x232 mm 3 (core volume 33 L) were used for the experimental validation. Operating Mode Table 4: Performance calculation of the developed heat pump (Shiba et al. 2007). Cold water Cold water Hot water Hot water Cooling inlet temp. inlet temp. inlet temp. outlet temp. capacity (kw) Heating capacity (kw) Cooling 12 7 25 30 45.6 53.9 The testing conditions of Shiba et al. are used to simulate micro-channels heat exchangers. At equivalent performance, the volumetric flux is presented in Figure 3. The volume of MCHE does not include inlet/outlet distributors. For PHE, the same heat transfer area was used for the evaporator and condenser, which results in a lower volumetric capacity for the evaporator. For MCHE, the same tendency is observed. The volumetric flux is increased by 144 and 154 % in the evaporator and condenser respectively, with the micro-channel technology. No data was reported concerning the pressure drop of water and refrigerant. Capacity/Core Volume (kw/m3) 4500 4000 3500 3000 2500 2000 1500 1000 500 0 MCHE Evap PHE Evap MCHE Cond PHE Cond Figure 3: Comparison of the volumetric capacity of MCHE and PHE (Shiba et al. 2007). 4.2 Indirect system model results and comparison The performance of the indirect system was compared to a base case data performance of a direct expansion direct system. The direct system performance is presented in Table 5. The direct system operates with R-407C. The compressor displacement rate is 28.8 m 3 /h. The heat-exchanger technology is a conventional finned-tube coil. The external air flow rates are fixed by the machine at 4000 m 3 /h at the cooler and 8000 m 3 /h at the radiators. The air inlet temperatures are given in Table 5.

2110, Page 7 System Air inlet conditions ** Table 5: Comparison of direct to indirect system performances. Cold water Hot water Cooling Sensible Heating regime regime capacity /Latent capacity (kw) cooling (kw) (%) Cooling COP Refrigerant charge (g/kw) Direct 42/33/51.5 - - 31.2 55/45 41.4 3.1 400 Indirect 42/33/51.5 20/16.1 53.3/60.2 31.2 65/35 40.8 3.2 10 **Outdoor air temperature / Indoor air temperature / indoor air relative humidity (%) The optimized indirect system performance is presented in Table 5. The results show that same cooling capacity and COP are achieved with the indirect system. The compressor displacement rate is 35.2 m 3 /h. Figure 4 presents the temperature levels achieved with the direct and the indirect systems, as well as the optimized HTF inlet/outlet temperatures for TG matching. The average evaporating temperature of the indirect system is 13.4 C, while that of the direct system is 11 C. This result suggests that the evaporator is undersized. The average condensing temperature of the direct system is 58.2 C compared to 61.6 C in the indirect system. The thermodynamic cycle is shifted upwards with the increase of evaporating temperature in the indirect system. The compression ratio is increased from 3.6 to 3.7. 70 60 Temperature 50 40 30 20 10 0 Direct Ref. Indirect Ref. Indirect HTF Figure 4: Comparison of direct and indirect cycle temperatures. The results presented below are related to the primary micro-channels heat exchangers. The simulated heat exchanger geometrical configurations are presented in Table 6. Table 6: Micro-channels HTF/REF HX characteristics data. Evaporator model Condenser model Flow arrangement Counter-flow Counter-flow HX length mm 0.4 0.4 HX width mm 0.2 0.22 Number of plates 102 102 Channel D h (HTF/REF) mm 1/0.5 1/0.5 Channels number / Plate (HTF/REF) 146/220 133/200 Effective area(htf/ref) m² 10.8/8 11.9/8.8 The evaporator and the condenser volumes are respectively 10.1 and 11.1 L. The volumetric fluxes are 3000 and 3500 kw/m 3. The compactness of the exchangers is around 1900 m 2 /m 3. The flow regime is laminar. Table 6 shows that the refrigerant charge is 10 g/kw. The charge calculation excludes the volume of headers. In two-phase flow, the charge is estimated by the homogeneous model.

2110, Page 8 5. CONCLUSIONS AND PERSPECTIVES The performance of an indirect air conditioning system operating with a zoetrope mixture R-152a/R-32 (80/20%) has been evaluated through an accurate modeling of primary and secondary heat exchangers. The micro-channel technology has been introduced to primary heat exchangers. The simulations show that an indirect system can be as efficient as a direct system by reducing the minimum approach in heat exchangers. The modeling correlations for zeotropic mixtures in micro-channels are insufficient and need further research work. Well-known correlations developed for evaporation and condensation of pure refrigerants have been used. Knowing that heat transfer coefficient of zeotropic mixtures is reduced compared to pure components, experimental validation is necessary. This work will be the subject of a future investigation. NOMENCLATURE Nomenclature Subscripts A cross sectional area m² w wall D diameter m sat saturation D displacement rate m 3 /h l liquid dc element charge kg v vapor G mass flux kg/m²s cpr compressor g gravitational acceleration m/s² h enthalpy kj/kg Greek letters h heat transfer coefficient W/K.m² density kg/m 3 hfg vapor liquid enthalpy kj/kg v volumetric efficiency k thermal conductivity W/K.m is isentropic efficiency P pressure Pa specific volume m 3 /kg q heat flux W/m² void fraction x vapor quality efficiency μ dynamic viscosity Pa.s REFERENCES S. S. Bertsch, E. Groll, S. Garimella, 2008, Refrigerant flow boiling heat transfer in parallel microchannels as a function of local vapor quality, Heat Mass Transfer. A. Cavallini, D. Del Col, L. Doretti, M. Matkovic, L. Rossetto, C. Zilio, 2005, Condensation heat transfer and pressure gradient inside Multiport Minichannels, Heat Transf. Eng., vol. 26, no. 3, p. 45-55. A. Cavallini, L. Doretti, M. Matkovic, L. Rossetto, 2006, Update on condensation heat transfer and pressure drop inside Minichannels, Heat Transf. Eng., vol. 27, no. 4, p. 74-87. V. Dupont, J.R. Thome, A.M. Jacobi, 2004, Heat transfer model for evaporation in microchannels. Part 2: comparison with the database, Heat Mass Transfer, vol. 47, p. 3387-3401. S. Koyoma, K. Kuwahara, K. Nakashita, K. Yamamoto, 2003, An experimental study on condensation of refrigerant R-134a in a multi-port extruded tube, Int. J. Refrig., vol 24, p.425-432. W. J. Mulroy, P.A. Domanski, D. A. Didion, 1994, Glide matching with binary and ternary zeotropic refrigerant mixtures, Part 1. An experimental study, Int. J. Refrig., vol. 17, no. 4, p. 220-225. Y. Shiba, R. Ooka, Development of a high performance water-to-water heat pump for ground source application, 2007, Ashrae transactions, vol. 113, part 2. J.R. Thome, 1996, Boiling of new refrigerants: a state of the art review, Int. J. Refrig., vol. 19, no. 7, p. 435-457. J.R. Thome, V. Dupont, A.M. Jacobi, 2004, Heat transfer model for evaporation in microchannels. Part 1: presentation of the model, Heat Mass Transfer, vol. 47, p. 3375-3385. G. Venkatarathnam, G. Mokashi, S. Murthy, 1996, Occurrence of pinch points in condensers and evaporators for zeotropic refrigerant mixtures, Int. J. Refrig., vol. 19, no. 6, p. 361-368. W. W. Wang, T. D. Radcliff, R. Christensen, 2002, A condensation heat transfer correlation for millimeter-scale tubing with flow regime transition, Exp. Thermal Fluid Science, vol. 26, p.473-485.