Rotary type Oil-free Air Compressor General Catalogue. Oil-free Scroll Air Compressor Oil-free Claw Air Compressor

Similar documents
OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

High efficiency and Energy saving

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-37 VSD+ (7-37 kw/10-50 hp)

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

WIND Technical Description

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Global Series Screw Air Compressors Life source of industries

for Light Commercial Use

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

Global Series Screw Air Compressors Life source of industries HP

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Largo & Allegro. Air Compressors LARGO & ALLEGRO

Rollair. Air Compressors. Rollair 15-40E

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

Mink MV. Claw Vacuum Pumps for Rough Vacuum Industrial Applications. Claw Vacuum Technology by Busch

ROTARY SCREW COMPRESSOR CSA 5,5-7, HP

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save

NEW INTELLIGENT AIR TECHNOLOGY

Oil-injected rotary screw compressors GA GA

Vacuum Pump Vacuum Pump

L30 - L250. Oil Injected Rotary Screw Compressors. Engineered to Save

Ingersoll Rand 5-15 hp. Rotary Screw Compressors

Centrifugal Chiller. GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

L07 - L22. Oil Injected Rotary Screw Compressors. Intelligent Air Technology

EG Series Screw Air Compressors Life source of industries HP

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Energy Impacts of Compressed Air

Refrigeration air dryer

ROLLAIR AIR COMPRESSORS

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

Largo & Allegro. Rotary Screw Compressors LARGO & ALLEGRO 23-36

Rotary screw compressors

Reliability & efficiency without compromise

Rotary screw Air compressors. Fixed Speed 5 15HP

Rollair. Rotary Screw Compressors ROLLAIR E-50E (V)

CPF PRODUCT DESCRIPTION

ROTARY SCREW COMPRESSORS

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA / GA / GA VSD (11-37 kw/20-50 hp)

EG Series Screw Air Compressors Life source of industries kw

HITACHI BEBICON AIR COMPRESSORS TANK MOUNT BEBICON PACKAGE BEBICON OIL FREE SCROLL AIR COMPRESSORS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

The High-efficiency Air-cooled Chiller "H series"

CPVS PRODUCT DESCRIPTION

Reliability & efficiency without compromise

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Reliability & efficiency without compromise

Atlas Copco. Oil-free Scroll Compressors SF 1-22 ( kw/2-30 hp)

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

OIL-FREE SCREW AIR COMPRESSORS PRODUCT CATALOG

Water Pump. Constant Water Pressure

SCK. Air Compressors SCK 3-40 & ALLEGRO 8-11

L07 L22 (10 30 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L Series

RDS SERIES REFRIGERATED COMPRESSED AIR DRYERS ENERGY SAVING REFRIGERATED COMPRESSED AIR DRYERS SCFM

Reliability & efficiency without compromise

CPC PRODUCT DESCRIPTION

Compact design & easy maintenance

DENTAL AIR. LFx LF SF Class 0 clean air compressors. Atlas Copco dental compressors - 1

COMPACT CSL range 3-20 HP

Chapter 9: The basics of air preparation

OIL-FREE ROTARY SCREW COMPRESSORS Fixed Speed Regulated Speed (RS) D75 D275 INTELLIGENT AIR TECHNOLOGY

A Chiller is equipment to control temperature of customers heating sources. Application Examples

SCR ROTARY SCREW AIR COMPRESSORS

Screw Compressors HSD SERIES. Capacities from: 816 to 3002 cfm Pressures from: 80 to 217 psig

Rotary screw compressors

Distributed by: 2008 Ingersoll-Rand Company CCN IRITS

Practic - HLE. Piston Compressors 2 TO 10 HP 6 TO 500 LITRES

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

UltraDry s Features and Benefits

High-Performance, High-Reliability Gas Heat Pump

Fixed Speed Rotary Screw Compressors UP6S Series hp (11-22 kw)

Nitrogen Generation Systems Compressed Air Dryers

Screw Compressors ESM Fixed Speed & VS Variable Speed

L07 L22 (10 30 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L Series

Screw Compressors 15-22kW

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

ROTARY SCREW COMPRESSOR CSM MAXI 7, HP

Allegro. Rotary Screw Compressors. Allegro 8-14

Atlas Copco Oil-injected Rotary Screw Compressors. GA /GA VSD kw/ hp

OIL FREE COMPRESSED AIR Piston, Scroll & Screw Compressors 55 L/min to 42,763 L/min 2 Cfm to 1510 Cfm

Refrigerated Compressed Air Dryers

Thermal Shock Chamber TSE 11

Air-Cooled Condensing Units with Compact Screw Compressors

Genesis Series 5,5 to 22 kw. Compressed air at your service

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

Refrigerant air dryers. FD series ( l/s, cfm)

New standard in compressed air treatment, providing Energy Savings up to 99%

% by up ctoond re-heater and

Chapter B-2. Chapter 2. Air generation and distribution. Festo Didactic TP101

DC Inverter Smart VRF Products(R410A)

Refrigeration dryers DW 2-504

500 EX Fusion Compressor Series

Technical specifications GX

Atlas Copco Oil-injected Rotary Screw Compressors. GA 15-22/GA /GA VSD kw/15-40 hp

Transcription:

Rotary type Oilfree Air Compressor General Catalogue Oilfree Scroll Air Compressor Oilfree Claw Air Compressor

Quiet & Compact, Simple Air Quietness Easy operation Cleanness The scroll mechanism ensures silent and lowvibration operation, making for a comfortable working environment. Work can be done at ease even during nighttime. Just turning on and off the compressor is all that needs to be done for daily operation. In addition to error monitor and alarm functions, other functions such as remote control, and automatic restart after the voltage failure can be provided as options. Since it is an oilfree model, discharged air is clean. What's more, drainage is also clean because of the anticorrosive air tank that comes as a standard component. This keeps the office environment clean for people. 0.75 kw with aluminum and anticorrosive coating on internal surface 1.5 3.7 kw with stainless steel air tank Monitor Comparison with our other compressors Compact Compact design that upgrades the image of air compressor. The compressor can be installed easily even in narrow spaces where it was formerly difficult to install. Easy carrying, with wheels SLP15 22 needs almost same floor space as 1 page of newspaper to install Recipro tank mounted Recipro package Scroll compressor Wheels are available for 1.5 to 3.7kW as option (Picture: OCX813 is installed) Picture is Japan model. It may differ in each country or area. Oilfree scroll air compressor does not require any oil and water. Friendly Compressed air from Oil lubricated air compressor carries oil, moisture, and dust Oilfree air compressor can provide clean air The oillubricated reciprocating air compressor +SGP air pipe The oilfree air compressor +SUS air pipe Main component part FS OS sirocco fan Tip seal 3 OS FS Compression Chamber

Energy & Cost savings, Flexible air Energy Saving The multistage control offers optimal operation and energy savings. The system contains multiple compressors and motors. Multistage control is adopted to use an optimal number of compressors in line with the amount of air used. The ThinkAir Series compressors eliminates inefficient operation to save energy. Energysaving operation with 4 compressors when consumption Full operation with 6 compressors when consumption is high Multistage control to achieve greater energysaving performance than inverters Automatic startstop system using a pressure switch which is least energy loss. It offers optimal operation in line with the amount of air used. Differences in power consumption rate bontrol method Operation of multistage control to achieve high energy saving performance (multi stage control) Riskfree compressor If one compressor fails, the other multiple compressors mounted in the system start backup operation, preventing the supply of compressed air from being interrupted. Comparison of power consumption rate when the ThinkAir Series is used Cost Saving With conventional compressors, the unload time when compression is not required is also counted when the maintenance cycle is decided. The ThinkAir Series compressor is newly designed to calculate the load factor of the entire compressor system based on the operating/stop status of each of the multiple units mounted and extend the operation time according to this load factor. The life cycle cost of a compressor roughly breaks down into: Initial cost Electricity cost Maintenance cost The ThinkAir Series compressor can substantially c hange the life cycle cost from conventional compressors. Life cycle cost comparison between <Think Air Series> and other compressors Calculation conditions: Annual operation time Total amount of 10 years Each compressor equivalent to 22 kw <Average air consumption> 1.5 m3/min is assumed. (thousandyen) Other suction throttle Loaded and oilfree valve control unloaded models method control method Operating electricity cost Defective product cost Compressor maintenance cost Initial compressor cost Quietness Nostage oil models Oillubricated type screw compressor Stage oil models Oillubricated type screw compressor Loaded and unloaded control method Other oilfree models Oilfree 2stage compressor Air device maintenance cost The scroll mechanism ensures silent and lowvibration operation, making for a comfortable working environment.work can be done at ease even during nighttime. <60dB> 22kW and 37kW models operate lower noise level than 60dB(A) Air consumption rate Scroll power consumption rate Screw compressor power consumption rate (suction throttle valve control) Back up If one compressor fails, the other multiple compressors mounted in the system start backup operation, preventing the supply of compressed air from being interrupted. <52 53dB> 5.5kW/7.5 kw: Noise level equivalent to that inside an average office Picture is Japan model. It may differ in each country or area. on "Environment"! Friendly on "Cost"! It's clean, because it's oilfree Drain treatment is not necessary, because it's oilfree Proper drain treatment is required as drainage from the oil lubricated air compressor contains oil. The oillubricated reciprocating air compressor +SGP air pipe Proper drain treatment is required as drainage from the oil lubricated air compressor contains oil. it's friendly on environment and cost as drainage from the oilfree air compressor does not contain oil, and it's clean. The oilfree air compressor +SUS air pipe drainage from the oilfree air compressor drainage from the oil lubricated air compressor 4

Quiet & Compact, Simple Air Environment friendly membrane dryer Environment friendly membrane dryer which doesn t use hydro chlorofluorocarbon. It has purge cutoff function during non operation to avoid air loss. Environmentfriendliness Membrane dryer doesn t use any hydro chlorofluorocarbon Purge cutoff function It's new oilfree scroll air compressor <SmartAir> Series Purging air Hollow fiber Orifice Dry compressed air Moist compressed air Dehumidification principle Membrane Air Dryer uses a hollow fiber that allows the vapor can get through easily while it is harder for air (Oxygen and Nitrogen) to pass The world's first 0.75kW oilfree scroll air compressor 1 phase model as standard enables easy installation. Simple & Compact with small footprint design. 1 page of new paper space is enough for installation. More smart, More compact. SmartAir Specifications Picture is Japan model. It may differ in each country or area. Model Motor rated output kw(hp) Working pressure MPa Free Air delivery L/min Air Receiver L Air outlet connection B External dimensions (WxLxH) mm Weight kg Noise level db (A) Control system SLPA07EC 0.75kW (1HP) 0.60.8 74 5 Rc 1/4 355x590x690 50 45 SLPA15EB SLPA22EB 1.5kW (2HP) 2.2kW (3HP) 0.650.8 165 250 20 20 Rc 3/8 Rc 3/8 537x483x875 95 95 45 49 Pressure switch SLPA37E 3.7kW (5HP) 410 35 Rc 3/8 545x622x1,058 134 49 1.0MPa model Model Motor rated output kw(hp) Working pressure MPa Free Air delivery L/min Air Receiver L Air outlet connection B External dimensions (WxLxH) mm SLPA151EB SLPA221EB 1.5kW (2HP) 2.2kW (3HP) 0.81.0 130 215 20 20 Rc 3/8 Rc 3/8 46 537x483x875 95 50 Pressure switch SLPA371E 3.7kW (5HP) 345 35 Rc 3/8 545x622x1,058 134 Air delivery is discharged air volume converted into atmospheric pressure. Contact to us for guaranteed value. Noise level is measured in an anechoic room at full load operation, at the distance of 1.5m from the front. Supplemental air receiver is necessary for smaller than 3.7kW model based on use condition. Contact to us for selection. Dimensions are outer size, excluding protrusions such as ball valve. Height of SLPA07EC includes casters. Weight kg Noise level db (A) Control system 5

Energy & Cost savings, Flexible air The system may contain two compressors and motors. Multistage control is adopted to use an optimal number of compressors in line with the amount of air used. The system may contain two to eight compressors and motors. Optimal operation according to the amount of air used enables big energy and cost savings. it's <ThinkAIr> series The system may contain three to four compressors and motors. Multistage control is adopted to use an optimal number of compressors in line with the amount of air used. Internal structure Air end Motor Base Touch panel The system may contain six to eight compressors and motors. Huge energy savings as well as converting operation time to a load factor to reduce maintenance cost. ThinkAir Specifications Picture is Japan model. It may differ in each country or area. Model Motor rated output kw(hp) Working pressure MPa Free Air delivery L/min Air Receiver L Air outlet connection B External dimensions (WxLxH) mm Weight kg Noise level db (A) Control system SLPA55E SLPA75E SLPA110E SLPA150E SLPA220C SLPA300C 2.2kW + 3.7kW (7.5HP) 3.7kW x 2 (10HP) 3.7kW x 3 (15HP) 3.7kW x 4 (20HP) 3.7kW x 6 (30HP) 3.7kW x 8 (40HP) 0.650.8 0.60.7 670 835 1,225 1,670 2,700 3,600 Rc 3/4 Rc 3/4 Rc 3/4 Rc 1 Rc 1 1/2 Rc 1 1/2 650x955x1,195 650x955x1,555 1,400x1,140x1,640 245 265 330 425 900 1,050 52 53 56 58 59 60 Multistage control Automatic startstop 1.0MPa model Model SLPA551E SLPA751E SLPA1101E SLPA1501E SLPA2201C SLPA3001C Motor rated output kw(hp) 2.2kW + 3.7kW (7.5HP) 3.7kW x 2 (10HP) 3.7kW x 3 (15HP) 3.7kW x 4 (20HP) 3.7kW x 6 (30HP) 3.7kW x 8 (40HP) Working pressure MPa 0.81.0 Free Air delivery L/min 560 690 1,035 1,380 2,070 2,760 Air Receiver L Air outlet connection B Rc 3/4 Rc 3/4 Rc 3/4 Rc 1 Rc 1 1/2 Rc 1 1/2 External dimensions (WxLxH) mm 650x955x1,195 650x955x1,555 1,400x1,140x1,640 Weight kg 245 265 330 425 900 1,050 Noise level db (A) 52 53 56 58 59 60 Control system Multistage control Automatic startstop 6

Cuttingedge technologies provide high efficiency, durability and clean air. It's an ultimate oilfree air compressor. Suction filter Inter cooler Oil cooler After cooler Compressor air end Solenoid drain valve (inter cooler) Oil mist catcher Emergency stop switch Control panel The further evolved compressor has claws in its compression chamber <Claw Compression principle> The air compressor has uniquely shaped claws in the compression chamber to achieve the highest level of efficiency in this range. Very high durability The uniquely shaped claw compressor consists of two rotors, one male and one female. Since they do not come into contact with each other as they rotate, the rotors do not wear easily and have a long life. The inner surface of the casing and the surface of the female rotor have special coating for greater air tightness. On each rotor, the inlet and outlet are located on symmetric faces. This prevents load from being applied in the axial direction, thus prolonging the life of the bearing. The rotors with accurate design are made of stainless steel and highly resistant to corrosion. Since they are located symmetrically relative to the axis, they are free from vibration. 9 Fully aircooled, twostage compressor The claws are of a fully aircooled type and do not require cooling fluid (oil, water or coolant). With no extra auxiliary devices needed, they are easy to maintain. The twostage compression mechanism is used in which an inter cooler cools highpressure compressed air to prevent unnecessary heat expansion in the first stage and the air is compressed efficiently in the second stage. Since the compression heat is low, the main unit runs with far less heat, resulting in stable performance. Touch panel as standard An easytooperate LCD touch panel is provided. It features maintenance indication, fault indication, remote control and external output terminals. An automatic power fail recovery function is also available as a standard feature.

Air/oil flow diagram Oil mist catcher as a standard component Fine dual control enables energysaving operation The compressor has an oil mist catcher as a standard component inside the package. There is no need to set the breathing line, which improves the installation environment. The latest compressor diagnosis system is used By connecting a measuring instrument to the measuring plug of the compressor main unit, the life of the bearings in the main unit can be checked in advance. In addition to energyefficient loaded and unloaded operation, automatic motor start/stop is supported. The motor automatically starts and stops up to eight times per unit time, minimizing inefficient unloaded operation. Energysaving chart Inverter control also available, Greater energy savings Compressor speed control in line with air consumption is provided under all load conditions to reduce power consumption, delivering an optimal air flow for the application. Constant pressure control keeps the target pressure within the range of ±0.01 MPa, achieving an energy saving of about 8.5% compared with the standard model (loaded and unloaded control). An energy saving of about 19% is achieved at 50% load compared to the standard model (loaded and unloaded control). The motor stops when air consumption is low. A builtin DC reactor is featured that controls harmonics of the inverter in compliance with the harmonic guideline of the Japan Electrical Manufacturers' Association (JEMA). Lowpressure speed increasing function Constant pressure control for energy saving Energysaving chart LRL model/stop LRV model Picture is Japan model. It may differ in each country or area. 10

"Absolute air" is friendly on user and environment Select the most suitable model to production sites Specifications Model Motor rated output kw(hp) Working pressure MPa Free Air delivery /min Outlet air temperature Air outlet connection B External dimentions (WxLxH) mm Weight kg Noise level db (A) Control system FRL220 22kW(30HP) 0.7 3.7 Intake air + 12 C G1 1,760x1,000x1,656 1,200 65 Fine dual FRL370 37kW(50HP) 0.7 5.6 Intake air + 12 C G1 1/2 1,760x1,000x1,656 1,335 68 Fine dual Select air receiver, 600L for 22kW, and more than 1,000L for 37kW Picture is Japan model. It may differ in each country or area. 11

Specifications Model Motor rated output kw(hp) Working pressure MPa Free Air delivery /min Outlet air temperature Air outlet connection B External dimentions (WxLxH) mm Weight kg Noise level db (A) Control system FRV220 22kW(30HP) 0.7 3.7 Intake air + 12 C G1 1,760x1,000x1,656 1,230 65 Inverter FRV370 37kW(50HP) 0.7 5.6 Intake air + 12 C G1 1/2 1,760x1,000x1,656 1,340 68 Inverter Select air receiver, 600L for 22kW, and more than 1,000L for 37kW Picture is Japan model. It may differ in each country or area. 12

For a long, problemfree service life of the compressor. Installation conditions 1) Install to a bright and enough space to perform maintenance 2) Do not install outside 3) Make sure the installation area provides good ventilation. Failures to have good ventilation will affect the compressor and will decrease the product life. 4) Operate the compressor within the range of temperature 2 C ~ 40 C 5) The installation area must be less humid and dustfree environment. *High humidity may result in leakage or malfunction of the compressor. *Dust may affect performance of the compressor and decrease the product life cycle. 6) Install the compressor on a level floor. The unlevel ground may cause vibration, noise, or failure of the compressor. 7) Secure the enough space for regular maintenance and inspection 8) Do not block the air compressor intake and exhaust grating. 9) Refer to the instruction manual for details. Ventilation 1) Installation area of the compressor must be ventilated at all times for efficient operation 2) For general ventilation, ensure the minimum amount of ventilation required to prevent from the temperature rise of 5 deg C. Refer to Fig 1 3) Install ventilation fans in consideration of the positions of cooling air inlet and cooling air outlet. Inappropriate installation of fans will disturb the air circulation in the workplace and may affect performance of the compressor. 4) The ventilation air speed at cooling air inlet must be slower than 5m/sec. 5) For local ventilation with ducting, pressure drop over the ducting is to be minimized. If Pressure drop with the air flow is less than 30Pa(3mmAq), the ventilation fan is not required. Refer to Fig 3 In case the ventilation fan is required, it shall be selected along with the pressure drop calculated vythe cooling air flow and ducting oressure drop. Refer to Fig 4 6) Refer to the instruction manual for details. Fig 1 D B Compressor C A General and local ventilation figure(fr) Ventilation fan Exhaust air Exhaust ductair Exhaust Removable Ventilation fan Exhaust ductair Exhaust Air inlet duct Air inlet duct Air inlet duct Fig 2 General ventilation Fig 3 Local ventilation 1 Fig 4 Local ventilation 2 General and local ventilation figure (SLPA) Exhaust Ventilation fan Exhaust Ventilation fan Exhaust duct Compressor Air inlet Compressor Air inlet Fig 3 Local ventilation Fig 2 General ventilation 13

Note 14