COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

Similar documents
EZ Plate Instantaneous

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

ENGINEERED DUPLEX ALLOY

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Semi-Instantaneous Steam Fired Water Heater

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

THE HARD WATER WATER HEATER

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Semi-Instantaneous Indirect Fired Water Heater

Packaged Steam Fired Water Heater

ASME Packaged Indirect Fired Water Heater

DigiTemp. Digital Water Tempering System. PVI.com

Indirect Fired Water Heater

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

High Capacity Instantaneous Steam Fired Water Heater

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Flo-Rite-Temp Instantaneous Steam/Water Heater

INSTALLATION & MAINTENANCE MANUAL CSXT INSTANTANEOUS STEAM WATER HEATER Copyright 2006 PVI Industries, LLC

Owner s Manual Therma-Stor II Heat Recovery System

DUKE UNIVERSITY DESIGN GUIDELINES

Request for Proposal Domestic Hot Water System Replacement At Sun Valley High School Penn Delco School District

ASME Packaged Electric Water Heater

Heat Transfer Packages

Flo-Rite-Temp Instantaneous Steam/Water Heater

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Commercial Semi-Instantaneous Water Heaters

Design and Construction Standards SECTION PLUMBING EQUIPMENT

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Bryan Water-Pak Indirect Systems 360,000 BTU to 4,500,000 BTU Inputs 199 to 3,533 Gallons Storage Capacity

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

SWH Series. STONESTEEL Packaged Copper Coil Water Heaters Steam/Boiler Water/High Temperature Hot Water Vertical or Horizontal

INSTALLATION & MAINTENANCE MANUAL COBREX STORAGE WATER HEATER Steam Energy Source Models ( )(-2)(L)(150-***)A-TCX

ARTESIAN 220 & 340 Instantaneous Indirect Water Heater By Dunkirk Boilers INSTALLATION AND OPERATING INSTRUCTIONS ENGINEERING MANUAL

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

SECTION PLUMBING EQUIPMENT

Control and power circuit fusing to meet N.E.C.

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

Light Duty Commercial Electric Water Heater

ASPE Seminar Water Heater Piping Strategies Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

Niles Steel Tank Hot Water Generator Installation and Operation Manual

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

INSTALLATION & MAINTENANCE MANUAL EZ PLATE INSTANTANEOUS WATER HEATER

SECTION DOMESTIC WATER HEATERS

SB Series Brazed Plate Heat Exchanger Installation Manual

ADMS. AERCO Digital Mixing Station. AERCO.com

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

Automatic Circulating Water Heaters

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

SECTION FUEL-FIRED DOMESTIC WATER HEATERS

Hydronic Product & Application Catalog

SECTION PLUMBING EQUIPMENT

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Tankless On Demand Electric Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Originators of the Flexible Water Tube design

SECTION FUEL-FIRED, DOMESTIC WATER HEATERS

P-K COMPACT SEMI-INSTANTANEOUS INDIRECT WATER HEATERS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Easy Installation & Service

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Shipboard Electric Water Heater

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Revitalize Building Mechanical Systems (4619)

A complete, compact steam heat exchange solution for process and domestic water heating requirements.

Shell & Tube Heat Exchangers

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

SECTION WATER HEATERS

High Efficiency Commercial Gas Water Heaters

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Commercial Gas Water Heaters

SEH Series. Stainless Steel Instantaneous Packaged Steam Fired Water Heaters

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Removal of Non-condensable Gases and Air Is Critical In A Steam System

SECTION ELECTRIC WATER HEATERS

Tepid Water Delivery System

Shipboard Electric Water Heater

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

BASCO U-TUBE & TANK IMMERSION HEAT EXCHANGERS. ...world leaders in heat transfer technology

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SPH Series. Vertical Packaged Storage Boiler Water Fired Plate Heat Exchanger Water Heaters CEMLINE CORPORATION

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SmartPlate. Water Heaters. AERCO.com

Technical Data Manual Model Nos. and pricing: see Price List

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

Transcription:

COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com

Steam-Fired Domestic Hot Water Generator COBREX Semi-Instantaneous steam water heaters utilize a double-wall, copper-tube, counter-flow heat exchanger to provide moderate to large amounts of domestic hot water using steam as its energy source. The heat exchanger is external to the small tank for the smallest footprint, accessible through a 3 foot door and a great solution for retrofit applications. Heat exchanger and tank are connected with factory-assembled piping. With COBREX paired to AquaPLEX tanks of 150 through 215 gallons, this semi-instantaneous offering will handle peak loads as well as dump loads. COBREX semi-instantaneous features electronic operating control with Modbus connectability to a building automation system. With the COBREX unique operation, no steam control valve is necessary when inlet steam pressure is 15 psi or less. At-a-Glance 2 Up to 7000 MBH output Up to 8425 gph hot water delivery from 40 to 140 F Duplex stainless steel tank with 150, 175, 215 gallons storage 100% copper and brass, double-wall, shell-and-tube heat exchanger with single-pass, counterflow design Redundant dual heat exchangers available No steam control valve required at 15 psi steam Twenty-five year pressure vessel corrosion warranty

Advantages of the COBREX Water Heater No Steam Control Valve Needed with 15 psi Steam Provides simplified heater operation and lower maintenance cost. Design eliminates a typically large and expensive steam control valve and actuator and the associated maintenance and replacement cost. Circulation Flow Diffusers Diffusers dissipate the pressure and velocity of the water circulating back into the vessel from the heat exchanger. This allows 80% of the water stored in the tank to exit the heater at usable temperature. Redundancy Dual heat exchanger models can be operated and isolated independently to allow maintenance on one exchanger without an interruption in hot water supply. Circulation Pump and Control System Scaling in the heat exchanger is minimized by constant water circulation during a call for heat and a pump delay after the call for heat terminates. The condensate shutoff valve quickly causes the exchanger to completely fill with condensate and stops the flow of steam. Stopping steam flow and continuing domestic water flow combine to cool the exchanger below the temperature threshold where scale can precipitate from the water. Heat Exchanger Heat Exchanger and Tank on Separate Skids Installation of the entire system is greatly simplified by reducing the size and weight of the individual parts. The piping between the tank and heat exchanger is fully fabricated at the factory for simple field installation. Not Immersed in the Tank Heat exchanger removal is greatly simplified and the required pull space is only one heat exchanger diameter (maximum 10") away from the mounting stand. Lighter Weight and Easier to Move The largest heat exchanger is only 100 lbs. and is a fraction of the weight of a typical double-wall u-tube exchanger of equal capacity and greatly simplifies replacement if necessary. Clean-in-place Fittings The heat exchanger can be de-scaled in place without disconnecting any plumbing. Safety and Operating Controls Redundant Temperature and Safety Controls The combination of an electronic controller, high limit, pump shutoff, condensate shutoff valve and heat trap piping at the heat exchanger outlet prevent an over-temperature condition in the vessel. BAS Connectible Operating Control Full read/write capability through electronic operating control with Modbus protocol. BACnet gateways are available. Functions such as temperature setback, and remote over-temperature alarm notification are available. AquaPLEX Storage Tank Standard 25-year corrosion warranty. The duplex stainless steel tank is fully pickle-passivated and is naturally immune to corrosion in all potable waters. The tank requires no linings and no anodes rods or induced current anodes for corrosion protection. Unlike 316L or 304L stainless tanks, there is no concern about chloride stress corrosion cracking. 3

Heater Components Heat Transfer and Control System Hot Water Outlet Steam Inlet Hot Water Outlet Relief Valve Relief Valve CIP Fitting 140 Heat Exchanger Electronic Control Cold Water Inlet CIP Fitting Operating Probe Circulation Diffusers Connection Control Valve F&T Steam Trap Bronze Pump Cold Water Inlet 4

How It Works Steam Flow Hot Water Flow to Building Call for Heat Begins Valve OPEN Hot Water Circulates Back to Tank Pump ON Flow 135 Cold Makeup Water Demand for hot water causes cold makeup water to enter the storage tank and reduces tank temperature. The operating probe senses the temperature drop signaling the control to energize the pump between tank and heat exchanger and opens the condensate valve. The pump draws cold domestic water through the exchanger, extracting heat from the steam causing it to condense and evacuate through the steam trap. The pressure drop caused by condensing steam causes more steam to enter the exchanger and the process continues. The heated water flows back to the storage tank through diffuser tubes that prevent the circulated flow from disturbing the natural stratification of water in the tank and allows more than 80% of usable hot water from storage to enter the building at the required temperature. When demand for hot water ends, the pump will continue to operate until the tank returns to the required stored water temperature thus ending the process. Steam Flow Ends......as the Exchanger Fills with Return Piping Serves as a Heat Trap 140 Call for Heat Ends ( Control System) Immediately after the call for heat terminates, the condensate valve is closed, trapping condensate in the heat exchanger. Steam continues to condense until the exchanger is filled with condensate and the flow of steam is stopped completely. The pump remains energized for an additional minute to extract any residual heat from the exchanger and transfers it into the domestic water in the tank. The pump delay raises tank temperature an additional 2 F. Valve CLOSED Pump OFF after Time Delay Flow Stops 5

Robust Heat Exchanger The COBREX heat exchanger is a shell-and-tube design with domestic water in the shell and steam/condensate in the tubes. The exchanger is vertically oriented and single-pass. Steam and water paths are 100% counterflow and provide the greatest possible temperature differential at all points in the heat exchanger. The domestic water side also contains several baffles to create a circuitous and high velocity flow. This allows large amounts of hot water to be generated from a remarkably small heat exchanger. The straight, copper, double-wall tubes are brazed into brass tube sheets and contained within a solid copper shell. The exchanger is ASME stamped to Section VIII for 150psi maximum allowable working pressure (MAWP). Steam Inlet Copper Shell Brass Tubesheet Double-wall Tubes Hot Water Outlet Expansion Joint Breach Detection Port Cold Water Inlet Outlet 6

Specifications Available Configurations and Performance Model Btuh Output (@ 15 psi steam) Btuh per Gallon Recovery 40 to 140 F Configuration gallon/min gallon/hour 1200 840,000 5600 17 1010 single exchanger 1800 1,530,000 10,200 31 1840 single exchanger 2700 3,000,000 20,000 60 3600 single exchanger 3600 3,500,000 23,330 70 4215 single exchanger 1200-2 1,680,000 11,200 34 2020 dual exchanger 1800-2 3,070,000 20,467 61 3680 dual exchanger 2700-2 6,000,000 40,000 120 7200 dual exchanger 3600-2 7,000,000 46,667 140 8425 dual exchanger Single Exchanger Configuration Dual Exchanger Configuration Standard Equipment Heat exchanger ASME stamped, section VIII for 150 psi Pressure vessel ASME stamped, section IV HLW for 150 psi Three year heat exchanger warranty 25-year pressure vessel warranty Completely pre-fabricated tank-to-exchanger piping is all non-ferrous and includes pump, y-strainer, isolation valves, unions, CIP valves and ASME relief valve Factory-authorized startup and first year service policy Bottom drain valve and ASME relief valve Float and thermostatic steam trap Electronic operating control with MODBUS capability High-temperature limit Manway tank access (250 to 900 gallons) Complies with latest ASHRAE 90.1 standard Low lead compliant Refer to document PV8570 for complete list of standard and optional equipment 7

Manufacturing ASME Commercial Water Heaters Since 1961 PVI Industries 3209 Galvez Avenue Fort Worth, TX 76111 T: (817) 335-9531 Toll Free: (800) 784-8326 PVI.com PV 8598 6-2018 2018 PVI