Clarification Proposal Annex 1, PDA: A Global. Cleanroom and. Association. Clean Air Devices. Hasim Solmaz Lighthouse Worldwide Solutions

Similar documents
ISO Technical Committee 209 Status Report. Conor Murray Irish Representative, ISO TC 209 Committee Chairman Irish Cleanroom Society

Differences Matter: Knowing BMS and EMS Systems By: Jason Kelly

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Contamination Control for Life Science Applications

ISO INTERNATIONAL STANDARD

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

Pharmacy Solution Set

Factory & Hospital hygiene, Chap 21(7 th edition) Principles of GMP, Chap 23 (8 th edition )

ISO/TS TECHNICAL SPECIFICATION. Road vehicles Air filters for passenger compartments Part 1: Test for particulate filtration

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

OUR TRUSTED SERVICE & SUPPORT

Aseptic Barrier Systems

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

Laminar Flow Cabinets eco air V

The overview of standard of equipments used in asbestos removal Naroo Lee, Ph.D./Department of work environment

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

INTERNATIONAL STANDARD

PHARMACY DESIGN GUIDANCE UPDATE ON COMPLIANCE WITH USP CHAPTER 797 PHARMACEUTICAL COMPOUNDING - STERILE PREPARATIONS

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

International comparison of validation methods for dust concentration measurement

IS INTERNATIONAL STANDARD. Ergonomics - Visual danger signals - General requirements, design and testing

Contamination Control for Electronic and Semiconductor Applications

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Laminar Flow Hoods and Booths

Clean Room Solutions 2013

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

Cleanroom Technology. Complete solutions for pharmacies.

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

Theatre Classification and Air Particle Count Is that Surveillance?

PhEn Semester Review. J. Manfredi Spring 09

Investigation of the Performance of the Air Purifier in High-Risk Hospital Rooms by Counting Particles

INTERNATIONAL STANDARD

Isolators, RABs and Mobile Clean Rooms in Aseptic Processing. Gary Partington Walker Barrier Systems

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

REAL TIME LABORATORY MONITORING SYSTEM

CIRCULAIRE LAMINAR AIR FLOW

A company for the design and manufacture of cleanroom equipment

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

BioSafety Cabinet- Class 100

ISO INTERNATIONAL STANDARD

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

INTERNATIONAL STANDARD

CLASSIFICATION REPORT

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Loss Prevention Standard

Microbiological Safety Cabinets ENVAIR eco safe Comfort

PQS Independent type-testing protocol

Code of Practice Version 2 Metal Detection and X-Ray Systems

Microbiological Safety Cabinets ENVAIR eco safe Comfort Plus

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

Medical electrical equipment

2010 Topas GmbH. Company Profile

INTERNATIONAL STANDARD

Quick Reference Guide to Cabinet types

This is a preview - click here to buy the full publication TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

INTERNATIONAL STANDARD

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

AEROSOL SPECTROMETERS

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ETSI Standard Environment Engineering (EE); Thermal Management requirements for outdoor enclosures

STANDARD OPERATING PROCEDURE 1/1/07 DYCEM HOUSEKEEPING Medical Devices and Terminal Sterilized Pharmaceutical Products

SMA Microbial Air Sampler System Product Guide

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Cleanrooms and associated controlled environments Part 3: Test methods (ISO :2005)

ESSENTIAL REQUIREMENTS CHECK LIST

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

MassBioLogics Welcomes. The New England Chapter Parenteral Drug Association. March 12, 2008

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

COMMISSION DELEGATED REGULATION (EU) /... of

Division III Process Gas Treatment Equipment

A SINGLE GLOBAL LEGISLATION

INTERNATIONAL STANDARD

New CEN Enquiry procedure - 3 Month enquiry with weighted vote and optional formal vote for CEN home-grown projects

August 3, Marshal Sterio Surgically Clean Air, Inc 3451 Lake Shore Blvd. W. Toronto, ON M8W 1N2. Dear Mr. Sterio:

INTERNATIONAL STANDARD

This document is a preview generated by EVS

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY

CBC s Inspection Findings and Possible Remedies Thereto

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Cleanroom Air Showers

Micro 6. Main Features

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

INTERNATIONAL STANDARD

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Does your equipment meet your needs and the operational capacity stated by the manufacturer?

Smoke Detector Testing

ISO INTERNATIONAL STANDARD. Industrial fans Mechanical safety of fans Guarding

This is a preview - click here to buy the full publication

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

INTERNATIONAL STANDARD

PROCEDURE FOR HANDLING RAPID ALERTS AND RECALLS ARISING FROM QUALITY DEFECTS

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

INTERNATIONAL STANDARD

This document is a preview generated by EVS

Transcription:

Clarification Proposal Annex 1, PDA: A Global Cleanroom and Association Clean Air Devices Hasim Solmaz Lighthouse Worldwide Solutions

Agenda GMP Annex 1 Definitions Cleanroom and Clean Air Device Classification Cleanroom and Clean Air Device Monitoring One Experiment 2

GMP ANNEX 1 MANUFACTURE OF STERILE MEDICINAL PRODUCTS Principle (1st paragraph) «...this type of manufacture (Sterile manufacturing) must strictly follow carefully established and validated methods of preparation and procedure» 3

Note : (2. Paragraph) This guidance does not lay down detailed methods for determining the microbiological and particulate cleanliness of air, surfaces etc. Reference should be made to other documents such as the EN/ISO Standards. 4

Cleanroom and Clean Air Device Classification 5

Cleanroom and Clean Air Device Classification GMP Annex 1 Clause #4 «Clean rooms and clean air devices should be classified in accordance with EN ISO 14644-1. Classification should be clearly differentiated from operational process environmental monitoring.» 6

ISO 14644-1:1999 Maximum concentration limits (particles M 3 of air) for particles equal to and larger than the considered sizes shown below:, ISO Classification Number(N) 0.1µm 0.2µm 0.3µm 0.5µm 1.0µm 5.0µm ISO 1 10 2 ISO 2 100 24 10 4 ISO 3 1,000 237 102 35 8 ISO 4 10,000 2,370 1,020 352 83 ISO 5 100,000 23,700 10,200 3,520 832 29 ISO 6 1,000,000 237,000 102,000 35,200 8,320 293 ISO 7 352,000 83,200 2,930 ISO 8 3,520,000 832,000 29,300 ISO 9 35,200,000 8,320,000 293,000 7

GMP Annex 1: 2008 Maximum permitted number of particles per m³ equal to or greater than the tabulated size At Rest In Operation Grade 0.5µm 5.0µm 0.5µm 5.0µm A 3 520 20 3 520 20 B 3 520 29 352 000 2 900 C 352 000 2 900 3 520 000 29 000 D 3 520 000 29 000 Not Defined Not Defined 8

ISO/DIS 14644-1.2 (will be voted 18 Nov, 2014) Maximum concentration limits (particles M 3 of air) for particles equal to and larger than the considered sizes shown below: (a) ISO Classification Number(N) 0.1µm 0.2µm 0.3µm 0.5µm 1.0µm 5.0µm ISO 1 b 10 d 2 d d d e ISO 2 100 24 10 d 4 d e ISO 3 1,000 237 102 35 d 8 e ISO 4 10,000 2,370 1,020 352 83 e ISO 5 100,000 23,700 10,200 3,520 832 d,e,f 29 ISO 6 1,000,000 237,000 102,000 35,200 8,320 293 ISO 7 c c c 352,000 83,200 2,930 ISO 8 c c c 3,520,000 832,000 29,300 ISO 9 c c c 35,200,000 8,320,000 293,000 Classification table in Draft ISO 14644-1 9

Reviewing GMP Annex 1: 2003 Maximum permitted number of particles per m³ equal to or greater than the tabulated size At Rest In Operation Grade 0.5µm 5.0µm 0.5µm 5.0µm A 3 500 1* 3 500 1* B 3 500 1* 350 000 2 000 C 350 000 2 000 3 500 000 20 000 D 3 500 000 20 000 Not Defined Not Defined According to European Medicines Agency; (EMA, Proposals for amendment, 21 September 2005) *The maximum permitted number of particles at 5.0μm is established at 1/ m³ but for reasons related to false counts associated with electronic noise, stray light, etc. a limit of 20/m3 could be considered. 10

Reviewing GMP Annex 1: 2003 New developments in technology and with a new calibration standard ISO 21501-4:2007, better resolution, counting efficiency, less noise and false count rate is possible. Also, as per GMP Annex 1, Clause #13, «The occasional indication of 5.0 μm particle counts may be false counts due to electronic noise, stray light, coincidence, etc. However consecutive or regular counting of low levels is an indicator of a possible contamination event and should be investigated.» 11

PDA, Proposal for Amendment According to PDA comments letter to (April 24, 2006); «we have revised the table to be more aligned with EN ISO 14644-1, which is internationally accepted standard for non-viable particle classification» 12

New GMP Annex 1: 20XX Classification Standpoint Maximum permitted number of particles per m³ equal to or greater than the tabulated size At Rest In Operation Grade 0.5µm 5.0µm 0.5µm 5.0µm A 3 520 Not Defined/0 3 520 Not Defined/0 B 3 520 Not Defined/0 352 000 2 900 C 352 000 2 900 3 520 000 29 000 D 3 520 000 29 000 Not Defined Not Defined Classification : Only 0.5µm can be used as per ISO 14644-1. GMP Annex 1, Clause #5 «For classification purposes EN/ISO 14644-1 methodology defines both the minimum number of sample locations and the sample size based on the class limit of the largest considered particle size and the method of evaluation of the data collected» 13

New GMP Annex 1: 20XX Classification Standpoint Maximum permitted number of particles per m³ equal to or greater than the tabulated size At Rest In Operation Grade 0.5µm 5.0µm 0.5µm 5.0µm A 3 520 Not Defined/0 3 520 Not Defined/0 B 3 520 Not Defined/0 352 000 2 900 C 352 000 2 900 3 520 000 29 000 D 3 520 000 29 000 Not Defined Not Defined Classification : 5.0µm should be zero according to ISO/DIS 14644-1.2 Table 1 notes; d) Sampling and statistical limitations for particles in low concentrations make classification inappropriate e)... Greater than 1 micron particles make classification at this particle size inappropriate due to potential particle losses in sampling system 14

Cleanroom and Clean Air Device Classification GMP Annex 1, Clause #6, «Portable particle counters with a short length of sample tubing should be used for classification purposes because of the relatively higher rate of precipitation of particles 5.0μm in remote sampling systems with long lengths of tubing.» Lenght of tube sould defined based on experiment data. 15

3 Meters (10 ft) ~ Loss of 15% 5µm particles Portable particle counters with less than 3 meters should be used... 16

Cleanroom and Clean Air Device Classification GMP Annex 1, Clause #7, «In operation classification may be demonstrated during normal operations, simulated operations or during media fills as worst-case simulation is required for this. EN ISO 14644-2 provides information on testing to demonstrate continued compliance with the assigned cleanliness classifications.» ISO/DIS 14644-2.2 ; Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration (ISO 14644-2:2000 ; Specs for testing and monitoring to prove continued compliance with ISO 14644-1) 17

Cleanroom and Clean Air Device Monitoring 18

Cleanroom and Clean Air Device Monitoring GMP Annex 1, Clause#8 «monitoring locations based on a formal risk analysis study and the results obtained during the classification of rooms and/or clean air devices» Needs to refer ICH Q9 Quality Risk Management which is adopted and published by EMA on Feb, 2011 (INS/GMP/79766/2011). 19

New GMP Annex 1: 20XX Monitoring Standpoint Maximum permitted number of particles per m³ equal to or greater than the tabulated size At Rest In Operation Grade 0.5µm 5.0µm 0.5µm 5.0µm A 3 520 0 3 520 0 B 3 520 0 352 000 2 900 C 352 000 2 900 3 520 000 29 000 D 3 520 000 29 000 Not Defined Not Defined Monitoring : Grade A 5.0µm particles should not exist during operation except; «...generation of particles or droplets from the product itself.» (Annex 1, #9) «The occasional indication of 5.0 μm particle counts may be false counts due to electronic noise, stray light, coincidence, etc. However consecutive or regular counting of low levels is an indicator of a possible contamination event and should be investigated» (Annex 1, Clause #13). 20

Cleanroom and Clean Air Device Monitoring Monitoring locations definitions should be more informative. Example 1; FDA Aseptic Processing Guideline ; «... per-cubic-meter particle count of no more than 3520 in a size range of 0.5 μm and larger when counted at representative locations normally not more than 1 foot (30cm) away from the work site, within the airflow, and during filling/closing operations. This level of air cleanliness is also known as Class 100 (ISO 5)» 21

Particle Distribution Experiment If particles are in laminar air flow, they should follow the pattern and fall vertically HEPA 30 cm 30 cm 22

Particle Distribution Experiment If particles are in laminar air flow, they should follow the pattern and fall vertically, so isoprobe should represend only an air column, not less than 30 cm (1 foot) HEPA ~3 cm 23

Particle Distribution Experiment 24

Particle Distribution Experiment 29 pcs. Online Particle counters, 0.5 and 5.0 micron channels 25

Particle Distribution Experiment : Center Point No of Points : 1 : 75 mm No of Points : 4 : 150 mm No of Points : 4 : 212 mm No of Points : 4 : 225 mm No of Points : 4 : 300 mm No of Points : 4 : 335 mm No of Points : 8 Total 29 points, 21 points are less than 30 cm from center. 26

Particle Distribution Experiment ISO Class 5, Grade A Conditions Under HEPA 0.45 m/s laminar airflow 0.5 micronpolystyrene Latex(PSL) particles 27

Particle Distribution Experiment 28

Particle Distribution Experiment 0.5 micron Polystyrene Latex(PSL) particles introduced to laminar airflow, in same direction and same air velocity (0.45m/s) HEPA 29

Particle Distribution Experiment Results DISTRIBUTION PERCENTAGE (%) vs. SAMPLING DURATION 5 min. 10 min. 15 min. 20 min. 25 min. 30 min. 35 min. 40 min. 45 min. 0 mm 23.0% 24% 24.5% 24.5% 25.1% 25.5% 25.9% 26.4% 26.7% 75mm 24.3% 25.0% 24.9% 24.9% 25.2% 25.2% 25.5% 25.7% 25.9% 150mm 16.9% 17.0% 16.7% 16.7% 16.5% 16.4% 16.3% 16.3% 16.2% 212mm 12.1% 11.7% 11.9% 11.9% 11.8% 11.7% 11.6% 11.5% 11.4% 225mm 10.5% 10.3% 10.4% 10.4% 10.1% 9.9% 9.7% 9.5% 9.3% 300mm 6.9% 6.5% 6.3% 6.2% 6.0% 5.8% 5.6% 5.5% 5.3% 335mm 6.2% 5.4% 5.3% 5.4% 5.4% 5.4% 5.3% 5.3% 5.2% 30

Particle Distribution Experiment 30,0% 25,0% 20,0% 15,0% 10,0% 0 mm 75mm 150mm 212mm 225mm 300mm 335mm 5,0% 0,0% 5 min. 10 min. 15 min. 20 min. 25 min. 30 min. 35 min. 40 min. 45 min. 31

Particle Distribution Experiment Results, ~95% of all particles distributes within 30 cm Particles are not following the laminar pattern Reason? : Other Forces; Brownian motion: small particles suspended in gas or liquids come into contact with gas molecules. Thermal variation (thermophoresis) Electrostatic charges 32

Cleanroom and Clean Air Device Monitoring GMP Annex 1, Clause #11, «...the length of tubing and the radii of any bends in the tubing must be considered...» Example 2; ASTM F50-07 Standard Practice for Continuous Sizing and Counting of Airborne Particles «...a maximum transit tube length of 3 m can be used. If a flexible transit tube is to be used, then no radius of curvature below 15 cm shall be used.» 33

Thank you! Hasim Solmaz Lighthouse Worldwide Solutions hsolmaz@golighthouse.com 34