Chiller System RFCS. Application Field. Symbol. General. Product Features

Similar documents
FluidAqua Mobil FAM Economy Series

FluidAqua Mobil FAM 25/45/60/75/95 Series

FluidAqua Mobil FAM Economy Series

FluidAqua Mobil FAM 5

Air Cooler Industry OK-ELC 0-7

Industrial cooling systems LT

LAUDA WK class. Reliable, large selection of models, compact construction

Recirculating Coolers

cooling tailor made Customized OEM cooling units Product range the smart way of cooling!

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

EN aquatech.piovan.com

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Emerson Superheat Control. The smart solution for your application

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

3kW 6kW, QUBE Fiber Lasers

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

How to Select and Size a Chiller

The right temperature worldwide NEW. Excellent price-performance ratio Compact design Simple to use. LAUDA Microcool. Circulation chillers

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

GP SERIES Packaged Chillers

Water (R718) The Safe & Natural Refrigerant. echiller Future Proof Refrigeration

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING

GENERAL INFORMATIONS

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

Constant climate chamber with humidity

Oil-injected rotary screw compressors GA GA

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Emerson R290 Solutions for Commercial Refrigeration Applications

Constant climate chambers

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

LIGHT CURTAINS. Measuring and switching light curtains for a wide variety of applications.

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

Process air cooler series DV

Bulletin , March Electric Hot Gas Bypass Valves

Conditioning your ambient, maximising your comfort.

46C SERIES. powerreserve. Photoelectric sensors and light scanners with maximum function reserve.

Refrigeration dryers for energy efficient compressed air quality

Customers. The core of our innovation. Feeding&Conveying Drying Dosing Temperature Control Refrigeration. Granulation

Rev B, 9/2/2009. Kodiak Chiller Overview

Screw compressors SCK Capacity: m 3 /min

LAUDA Additional devices Immersion coolers, through-flow coolers, circulation heat exchangers

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

beta.line modular OFFSET-TECHNOLOGY FOR PROFESSIONALS Member of the technotrans group

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

SEMI Standard S2-0703, S8-1103, F

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Spacemaker. High Performance Air Conditioning. English

Temperature controllers TW, TO and TP, Speedy Therm

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

Added cooling capacity of 140 W. (air-cooled).

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Advantages / Characteristics

Buran DC DC 1175 AES / WB Air cooled / water cooled Refrigeration Dryers

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

A Chiller is equipment to control temperature of customers heating sources. Application Examples

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

OLF-5-TAK Tank connection kit 2.0

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

Precise Temperature Control; Compact Footprint

Vulcanic. Engineered Projects

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

TIMER CONTROLLED DRAINS

ef cooling - FURRER Industriekühlung GmbH Technical Data Water Cooling Units EPI-A 2 - EPI-A 6 norden cooling

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

Rotary Screw Compressors ASD T SFC With the world-renowned SIGMA PROFILE Air delivery from 0.56 to 5.51 m³/min Pressure 5.

TEMPERATURE SHOCK TEST CHAMBERS

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

ULTRAPAC SMART ULTRAPAC SMART INDUSTRIES

Rotary Evaporators designed

Precision Air Conditioner For Critical Application

Added cooling capacity of 140 W. (air-cooled).

SEMI-HERMETIC SCREW COMPRESSORS

Constant climate chamber with ICH-compliant illumination

MATERIALS FILTERS PRESSURE VALUE TESTS CARRIED OUT ON FILTERING ELEMENTS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Evaporators 60HZ version

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

±0.1 C. 40 kg. 47 kg. 69 kg 73 kg. With heating function. Convenient functions

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery 0.26 to 0.80 m 3 /min, Pressures bar

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Can precisely control the temperature of a heat source or process fluid.

PRODUCT GUIDE

E X V sistema Precision mechanics, powerful control. carel.com. connectivity, monitoring and remote managem,ent systems

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

Industrial cooling solutions

SHAKING WATER BATHS ENGLISH

LAUDA ECO. Precise, economical, flexible

Part IV: Flow Side Components Flow Diagram

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Transcription:

Chiller System RFCS Symbol Cooling circuit Refrigeration circuit Safety and regulation unit Condenser Application Field l Machine tools l Presses l Milling machines l Welding systems Whether integrated into a machine or used as a separate auxiliary cooler or insertion cooler, the RFCS range of chillers will tackle any cooling task and guarantees quality for your products with utmost precision. Compressor l Laser cooling Pump Evaporator Cooling fluid RFCS-G series General The RFCS cooling unit (chiller) is used to cool various liquids such as water, water glycol or oil down to the ambient temperature or below. The chiller system consists of refrigerator, pump, tank and controller and is able to set the temperature of the cooling media to a previously configured target value independently. Product Features l Fluid cooling system as separate auxiliary cooler or for integration into a machine l Can be used for any cooling tasks l Stand-alone control of the system by means of innovative controller design l Condenser available as water-cooled or air-cooled variant l Multiple cooling circuits l Precise temperature control accuracies from ±0.1 K l Optional outdoor installation l Think green act green: energyefficient mixer principle available as an option RFCS-D series Separate auxiliary coolers with high capacities up to 160 kw for cooling tasks in the machine tool sector. Several units can be connected in parallel to expand the capacity as required. Separate auxiliary cooler for cooling tasks in machine building (integration into the machine tool), capacities up to 7 kw Temperature control / remote maintenance H.I.B control unit 269

Operating Data Series Cooling power 1) [kw] Condenser Refrigerant aircooled watercooled Direct 4) DI 2) IW 3) (without tank) Pump capacity / flow rate Electrical supply 1) Dimensions LxDxH [mm] Weight [kg] 1.0 10 l/min @ 1.5 bar 230V - 50/60Hz 443 x 524 x 443 43 G0 1.5 10 l/min @ 1.5 bar 230V - 50/60Hz 443 x 524 x 443 45 2.3 10 l/min @ 1.5 bar 230V - 50/60Hz 443 x 524 x 443 48 D2 D3 3.3 15 l/min @ 2 bar 230V - 50/60Hz 480 x 420 x 800 80 3.3 15 l/min @ 2 bar 400/440V - 50/60Hz 480 x 420 x 800 80 4.5 15 l/min @ 2 bar 400/440V - 50/60Hz 595 x 555 x 1,131 130 5.6 15 l/min @ 2 bar 400/440V - 50/60Hz 595 x 555 x 1,131 130 D4 7.5 40 l/min @ 3 bar 400/440V - 50/60Hz 601 x 601 x 1,361 160 G4 G5 7.5 40 l/min @ 3 bar 400/440V - 50/60Hz 601 x 601 x 1,527 200 9.5 40 l/min @ 3 bar 400/440V - 50/60Hz 601 x 601 x 1,527 250 12 40 l/min @ 3 bar 400/440V - 50/60Hz 601 x 601 x 2,131 300 15 40 l/min @ 3 bar 400/440V - 50/60Hz 601 x 601 x 2,131 300 20 40 l/min @ 3 bar 400/440V - 50/60Hz 1,230 x 610 x 2,131 350 G6 26 40 l/min @ 3 bar 400/440V - 50/60Hz 1,230 x 610 x 2,131 380 32 40 l/min @ 3 bar 400/440V - 50/60Hz 1,230 x 610 x 2,131 400 40 90 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,134 1,000 50 90 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,134 1,000 60 90 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,134 1,000 G7 70 6) 150 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 750 90 6) 150 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 770 100 6) 150 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 780 135 6) 250 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 800 155 6) 250 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 900 1) Cooling capacity based on 35 C ambient air / water to condenser and 20 C process fluid supply temperature 2) DI = deionized water 3) IW = industrial water 4) Direct = Direct vaporization without refrigerant 5) Standard, additional voltages on request 6) Available as air-cooled variant with external condenser or heat exchanger Accessories l Higher capacity pumps available l Several parallel circuits l Ambient temperature-dependent control using separate temperature sensor l Serial interface for system monitoring l Filtration units for the refrigerant circuit l Flow indicator and flow monitoring l Extremely accurate control up to ±0.1 K, standard ±1.5 K l Speed-controlled fans 270

Design www.comoso.com In the standard versions, the RFCS cooling units are designed complete with compressor, air cooled condenser, submersible pump and electronic control. Optionally available with energy-efficient mixer control where a small hysteresis is required. G0 D2 D3 D4 G4 G5 G6 G7 271

Centralized Cooling Systems RFCS water-chiller with heat exchanger and HY-ECOBOX RFCS water chiller: The RFCS is used to prepare cold water. Regardless of the particular ambient temperature, cold water can be provided in a wide range of capacity classes and fed to the customer application. The unit is a water-cooled water chiller. The plate heat exchanger condenser transfers its process heat to a separate cooling-water circuit. Heat exchanger: RFCS cooling units with water-cooled condenser require a cooled water supply for heat removal. A heat exchanger is used when it is either not practical or not desirable to utilize mains water. Functioning at high external temperatures HY-ECOBOX: The HY-ECOBOX is an optional module which contributes to improved energy saving: when the ambient temperature drops below a certain level, the cooling machine's active cooling is switched off. The system then operates in passive cooling mode, using the heat exchanger. This energy manager can therefore only be used in combination with a heat exchanger. Advantages: l Saves resources, as no water is used l High energy-saving potential thanks to the HY-ECOBOX* l The RFCS transfers no heat into the building * ECOBOX: optional accessory for passive free cooling operation Functioning at low external temperatures 272

From the prototype to series production l Planning and advice from our specialists on site. You provide the task, we supply the solution. l Our own development centre produces market-driven, energy-efficient and cutting-edge solutions, to stay one step ahead of the state of the art. l The coolers are produced in the Bavarian town of Friedberg and rightly deserve the Made in Germany seal of quality! l In order to provide quality that is consistently very good, all equipment must undergo a function and performance test. l For service you can call on an international network of service engineers. Consultation and service with global reach. 273

Design Data Sheet, RFCS Cooling Unit Project: Contact: Telephone: E-mail: Date Created by Application Active cooling (RFCS): air-cooled water-cooled Installation site: Indoors Outdoors Series/housing*: D G Technical data Required cooling capacity: kw at and C operating temperature C ambient temperature Relative humidity: %RH Operating temperature adjustable from: C to C Supply voltage: V Ph Hz Temperature accuracy and control type Control accuracy: ±0.1 K ±0.5 K ±1.5 K Control type: Fixed value Controlled by ambient temperature Cooling fluid/refrigerant Cooling fluids: Water glycol % glycol: % DI water Conductance: μs/cm Mineral oil ISO / cst Pump specifications Flow rate: Operating pressure: Connection system, cooling circuit: l/min bar " internal thread Additional information on water-cooled RFCS: external cooling water supply Inlet temperature: min. C max. C Guaranteed water quantity: l/min Pressure p: min. bar max. bar Cooling water supply: e.g. well water, fresh water 274

Equipment Comment Paint (standard RAL 7035): Tank heating Flow monitoring Flow indicator Filter for cooling fluid (particle filter) Filtration rating: μm Controlled fan Air filter monitoring DI cartridges Conductance monitoring Conductance control Switching point: μs/cm Electric system Cooler plug connector with mains filter Power adaptor (internal 24 V supply) Power supply cable Main switch Comment Remote start (potential-free contact) Design: Supply / elec. connection (e.g. industrial connector, multi-pin) Transformer for special voltage Data interface (e.g. RS485) Interface specification Other accessories: Comments: Annual unit qty.: * Series/housing: The D basic housing is equipped with a horizontal condenser, making for flexible air routing/setup as access to the insides of the devices only needs to be possible from one side. The G basic housing is fitted with an upright condenser to provide compact installation space requirements even at higher capacity levels. 275

Note The information in this brochure relates to the operating conditions and applications described. For applications and operating conditions not described, please contact the relevant technical department. Subject to technical modifications and corrections. H.I.B Systemtechnik GmbH Winterbruckenweg 30 86316 Friedberg-Derching Germany Tel.: +49 821/ 747 71-400 Fax: +49 821/ 747 71-410 E-mail: info@h-i-b.de Internet: www.h-i-b.de HYDAC COOLING GMBH Industriegebiet 66280 Sulzbach / Saar Germany Tel.: +49 6897/ 509-01 Fax: +49 6897/ 509-454 E-mail: cooling@hydac.com Internet: www.hydac.com 276