Vanguard. Toxic & combustible gas detector

Similar documents
WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A. Installation and Maintenance Instructions

WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A. Installation and Maintenance Instructions

WirelessHART Toxic & Combustible Gas Detector P/N: TCD50H1A. Installation and Maintenance Instructions

IECEx Certificate of Conformity

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

Single Gas Clip and SGC Plus User s Manual Rev 2.3

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Duct Mount. Installation Instructions

Clip SGD. Portable single Gas Detector. User manual

For the Safety of Your

Safe Operation Manual. Honeywell IQ Force Gas Detector

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

Thank You for Attending Our February Webinar:

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

MGC Dock User s Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

MGC Dock User s Manual

RK / RK Methane Detector Operator s Manual

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron 8310 IR Detection of flammable gases and vapour

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Quick Start Guide For the

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Dräger X-am 2500 Multi-Gas Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ULTIMA X5000. MSAX5000.com

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Model D12-IR. Digital Gas Transmitter...

RK-05 Carbon Monoxide Detector Operator s Manual

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

SEC Signature Process Gas Analyzer

Spy Jeepmeter ope rati ng instructions

RK/ RK Combustible Gas Detector Operator s Manual

Dräger X-am 5000 Multi-Gas Detection

Certificate of Compliance

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

RK Multi Point Detector Operator s Manual

Net Safety ST3 XChem Toxic Gas Sensor

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

INSTRUCTION MANUAL HS-229G

Dräger Polytron 5700 IR Detection of flammable gases and vapours

OPTIBAR DP 7060 Supplementary Instructions

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Dräger X-am 5000 Multi-Gas Detection

Certificate of Compliance

RK-02 Multi Point Detector Operator s Manual

GasAlertMicroClip X3 Specifications

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

MT4 MAX/MT4 MAX + Infrared Thermometer

700G Series. Pressure Gauge. Safety Information

Certificate of Compliance

Owner s Manual. PIR-1 IR Learner

Dräger X-am 7000 Multi-Gas Detection

62 MAX/62 MAX + Infrared Thermometer

RK Hydrogen Sulfide Transmitter Operator s Manual

SmartPower Solutions. SmartPower Solutions. Product Data Sheet , Rev AC January Contents

Dräger Polytron 8700 IR Detection of flammable gases and vapors

VENTIS PRO SERIES. Product Guide

ue short form catalog Leaders in Safety, Alarm & Shutdown

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

180 Dexter Ave, P.O. Box 9143 Watertown, MA USA Phone: Fax: CP031210K

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Warranty Registration

RK-05 Combustible Gas Transmitter Operator s Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Users Manual. Air Velocity Meter

Dräger Polytron 8100 EC Detection of toxic gases and vapors

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Instruction Leaflet. Read instructions before operating. Retain for future reference.

MaxLite LED MICRO-T PANEL

Rosemount 2051T In-Line Pressure Transmitter

Solar Powered Wireless Photobeam Sensors

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Instruction Leaflet. Read instructions before operating. Retain for future reference.

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Remote Relay Module (RRM)

RK Carbon Monoxide Transmitter Operator s Manual

User s Manual For Model Aero-551 (Rev. Orig.)

Wireless Gas Monitoring

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

OLC(T) 100 FIXED GAS DETECTOR

ECHOLINE LOW PRESSURE MONITOR. Prevents Unwanted Shutdown Time and Space Saving UL Recognized

Transcription:

Toxic & combustible gas detector T C D 5 0 - B - 0 1

Capability Overview Wireless Capability WirelessHART communication 7.2 IEC 62591 compatible Integrated HART terminals Adjustable update rate Quick Mount Bracket Mounting bracket for pipe or wall mount Facilitates easy installation and replacement of unit Interoperability Seamless integration with existing WirelessHART networks and asset management systems Long Lifespan 5 years battery life* Battery pack is field replaceable in hazardous location areas Heavy Duty Design Class I, Div. 1&2 for hazardous areas Explosion-proof & intrinsically safe FLEXsense Sensor Automatically configures toxic or combustible gas sensor for readings in ppm or %LEL Sensor is field replaceable in hazardous location areas Easy Calibration and Use Configure, calibrate, and test onsite with the touch of a button 128x64 pixel graphic display showing gas concentration, network connection, and battery status *Based on an 8 second update rate. 5 years battery warranty valid upon battery warranty registration. WirelessHART is a registered trademark of Field Comm Group. FLEXsense is a trademark of United Electric Controls Co. 2 T C D 5 0 - B - 0 1

Specifications Sensor Hydrogen Sulfide (H 2 S) Methane (CH 4 ) Storage Temperature: 72 F (22 C) recommended Operating Temperature: -4 F (-20 C) to 122 F (50 C) Storage Humidity: 0% to 98% RH recommended Storage Pressure: 1.0 + 0.2 atm recommended Storage Life: 1 year in sealed package 3 years in sealed package Types: Electrochemical Nondispersive infrared Measurement range: 0 to 100 ppm 0 to 100 %LEL Resolution: 1 ppm 1 %LEL Accuracy 1 : +10 ppm +2% LEL or +5% of indication, whichever is greater Repeatability 2 : +10 ppm +2% LEL Response time (T90) 3 : 60 Seconds 30 Seconds Stabilization time: Up to 6 Hours at 72 F (22 C). See installation manual for details 1 Minute Note: Sensors are interchangeable & self-configurable with the transmitter base. Sensor allows for one-handed sensor installation in hazardous area without declassifying the area Battery Batteries: Operating Voltage: Average Battery Current: Life: Battery pack contains two Lithium battery cells 7.2 V <110uA typical (with H 2 S sensor) <300uA typical (with CH 4 sensor) 5 years based on an 8 second update rate 1 At standard conditions: 68 F (20 C) and 1.0 atm. Accuracy may vary with frequency, accuracy of calibration and environmental conditions (e.g., barometric pressure, temperature and humidity). 2 Measured at 50% LEL for CH4 sensor at 68 F (20 C) and measured at 25 ppm for H 2 S sensor at 68 F (20 C). 3 Excludes latency due to radio burst rate. T C D 5 0 - B - 0 1 3

Specifications Cont. Base Transmitter Operating Temperature: Operating Humidity: Material: Ingress Protection: Display: Display Language: Memory: Antenna: Mounting: Weight: -4 F (-20 C) to 140 F (60 C) 0% to 98% RH recommended Aluminum alloy (maximum copper content at 0.25%) with powder polyester paint; 316 stainless steel; nickel-plated brass; tempered glass Type 4X (enclosure only) Viewable area is 2.25 W x1.25 H (57.2mm x 31.8mm) Graphical LCD display English Programming and data are protected by a non-volatile EEPROM 2.4 GHz, Hazardous Area Antenna Supplied mounting bracket for 2 pipe or wall 7.84 lbs (Base) 9.61 lbs (Base with Sensor and Battery) Output and Access Communication WirelessHART HART 7.2; EDDL file available at Protocol: Process Variables: Primary Variable (PV): Hydrogen Sulfide (H 2 S) concentration in ppm Methane (CH 4 ) concentration in %LEL Secondary Variable (SV): Temperature ( C); Not available for Methane sensor Tertiary Variable (TV): Days since calibration (days) Quaternary (QV): Battery voltage (volts) Programming Access: HART hand-held communicator or via HART modem connected to HART terminals located in rear battery compartment or via remote access (e.g., asset management software such as Emerson AMS Device Manager) Calibration/Bump Test Via. external button on transmitter base Access: 4 T C D 5 0 - B - 0 1

how to order Step 1 - CHOOSE Transmitter MODEL TCD50H1A Base transmitter; includes enclosure, operating system, radio module, WirelessHART 7.2 communication protocol, 2.4 GHz antenna, and mounting bracket kit; excludes sensor and battery pack TCD50H1A01 TCD50H1A02 Base transmitter with FLEXsense Methane (CH 4 ) sensor; excludes battery pack Base transmitter with FLEXsense Hydrogen Sulfide (H 2 S) sensor; excludes battery pack Step 2 - CHOOSE A Battery 6361-807 Battery pack containing two lithium battery cells; 7.2V operating voltage* Options REPLACEMENT PARTS 6361-807 Battery pack containing two lithium battery cells; 7.2V operating voltage 62169-45 FLEXsense Methane (CH 4 ) sensor; sensor pack only, excludes base transmitter 62169-46 FLEXsense Hydrogen Sulfide (H 2 S) sensor; sensor pack only, excludes base transmitter Accessories 62169-50 Gas calibration kit including calibration cup and regulator 6361-811 Mounting bracket kit *Battery ships separately per US and International Transport Authorities (e.g., IATA). Follow proper disposal regulations for lithium batteries as they apply to your jurisdiction. T C D 5 0 - B - 0 1 5

Dimensional Drawings Calibration kit 71.1mm 2.75in 79.4mm 3.125in CALIBRATION CUP 915.9mm 36in NEOPRENE TUBING CALIBRATION GAS VENT HOSE 95.3mm 3.75in REGULATOR, FIXED FLOW RATE 0.25 to 0.8LPM 6 T C D 5 0 - B - 0 1 49mm 2in

Product Approvals & Ratings Model N. America Europe International TCD50H1A TCD50H1A01 TCD50H1A02 Class I Div. 1, Groups C & D, T4 USA: Class I, Zone 1, AEx db ia [ia] IIB T4 Gb Enclosure Type 4X** Canada: Class I, Zone 1, Ex db ia [ia] IIB T4 Gb -20 C < Ta < +60 C* II 2 (2) G Ex db ia [ia] IIB T4 Gb ITS 16 ATEX 18474-20 C < Tamb < +60 C* IECEx ETL 16.0016 Ex db ia [ia] IIB T4 Gb -20 C < Tamb < +60 C* *Ambient operating temperature range may vary with sensor type. **Enclosure type 4X ratings apply to enclosure only. UE declarations and third-party issued agency certifications are available for download at: www.ueonline.com/prod_approval. Compliance to Standards The device has been certified in accordance with the applicable requirements of the standards listed on page 5 of the installation and maintenance manual. T C D 5 0 - B - 0 1 7

Recommended Practices and Warnings United Electric Controls Company recommends careful consideration of the following factors when installing and operating the UE vanguard unit. Before installing a unit, the Installation and Maintenance instructions provided with the unit must be read and understood. This device is for monitoring and communicating gas concentration levels for data collection or record keeping and does not provide alarm signals. Misuse of this device may cause explosion and/or personal injury. These instructions must be thoroughly read and understood prior to installation of the device. The end-user is responsible for maintaining the device in full, operational condition. Install the device where shock, vibration and temperature fluctuations are minimal. Do not mount in ambient temperatures that exceed the limits on the device labelling. The device must be mounted vertically with the sensor pointing downward. Avoid dropping the device, as loosening of the threaded flame-proof joints or permanent damage may occur. When not in use, the device should be stored in a clean, dry area and within the temperature range listed within the device s environmental specifications. The only field replaceable parts are the battery pack and FLEXsense sensor. Substitution of other components will invalidate third party issued approvals and certifications, may impair suitability for Class 1, Div 1 location and void any warranties. Only battery packs and FLEXsense sensors provided by United Electric Controls are compatible with this device. New sensors must be calibrated after installation. Hydrogen Sulfide (H 2 S) is an extremely toxic gas, and exposure may result in loss of consciousness or death. Methane (CH 4 ) is a greenhouse gas and is extremely flammable. Exposure in closed areas may cause explosion, and result in loss of consciousness or death. LIMITED WARRANTY Seller warrants that the product hereby purchased is, upon delivery, free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller (Ex-works, Factory, Watertown, Massachusetts. INCOTERMS); provided, however, that this warranty applies only to equipment found to be so defective within a period (as defined in the chart below) from the date of manufacture by the Seller. PRODUCT SERIES/COMPONENTS/REPLACEMENT PARTS Electrochemical Sensors Infrared Sensors Vanguard Base Transmitter Battery WARRANTY 12 months 24 months 36 months 60 months* * 5 year battery warranty valid only with registration at Seller shall not be obligated under this warranty for alleged defects which examination discloses are due to tampering, misuse, neglect, improper storage, and in any case where products are disassembled by anyone other than authorized Seller s representatives. EXCEPT FOR THE LIMITED WARRANTY OF REPAIR AND REPLACEMENT STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES WHATSOEVER WITH RESPECT TO THE PRODUCT, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Limitation OF Seller s Liability Seller s liability to Buyer for any loss or claim, including liability incurred in connection with (i) breach of any warranty whatsoever, expressed or implied, (ii) a breach of contract, (iii) a negligent act or acts (or negligent failure to act) committed by Seller, or (iv) an act for which strict liability will be inputted to seller, is limited to the limited warranty of repair and/or replacement as so stated in our warranty of product. In no event shall the Seller be liable for any special, indirect, consequential or other damages of a like general nature, including, without limitation, loss of profits or production, or loss or expenses of any nature incurred by the buyer or any third party. UE specifications subject to change without notice. For a list of our international and DOMESTIC REGIOnal sales offices please visit our webpage www.ueonline.com 180 Dexter Avenue, P.O. Box 9143 Watertown, MA 02471-9143 USA Telephone: 617 926-1000 Fax: 617 926-2568 http://www.ueonline.com 8 T C D 5 0 - B - 0 1