TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

P R O D U C T D ATA S H E E T

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

P R O D U C T D ATA S H E E T

IGD.CO.UK

APPLICATION DATA SHEET

CH4 SO2NO2. C O2 mount options. The controller has two SPCO relays as standard with three 4-20mA outputs and an RS485 Modbus UK Design And Manufacture

APPLICATION DATA SHEET

TOCSIN 750 SERIES OLIVER IGD. Triton House Crosby Street Stockport SK2 6TS England

CH4 NO TOC-30A-AN1 TOC-30A-ANN TOC-30A-AN2 TOC-30A-AN3. Pepper Road Bramhall Technology Park Stockport SK7 5BW England. International Gas Detectors

APPLICATION DATA SHEET

GAS DETECTION International Gas Detectors CH4 NO

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

2-WIRE SYSTEMS OLIVER IGD. 2-Wire. Version 3.2 T750-INST. Addressable. Triton House Crosby Street Stockport SK2 6SH England

HART TOCSIN 903 SINGLE CHANNEL GAS DETECTOR USER INSTRUCTIONS. Oliver IGD Limited NEW WITH OPTIONAL. 4a Pepper Road Stockport SK7 5BW England

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Danfoss gas detection unit Type GD Heavy Duty

SUPREMATouch Modular Fire & Gas Detection System

Danfoss gas detection units

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Dräger Polytron 8000 Stationary gas detector (EC)

Multi-Gas-Controller MGC2

Recalibrate the way you look at gas detection

Dräger Polytron 8310 IR Detection of flammable gases and vapour

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Detection, Protection, Innovation

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Gas Controller Module GC-06

Dräger QuadGard Control System

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Sieger Apex. Flexibility that meets your requirements

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Industrial Grade Gas Detection Detecting The Difference

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Polytron 8200 Stationary gas detector (CatEx)

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

YOUR PARTNER IN FIRE & GAS DETECTION

TOCSIN 700+ INSTALLATION AND USER INSTRUCTIONS

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Danfoss gas detection units

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

System 57. An advanced World of intelligent gas detection system management

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

Products and performance

Industrial Grade Gas Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

System 57. An advanced world of intelligent gas detection system management

Personal & Portable Gas Monitors

GS100M Gas Detection Controller

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

3M Oldham MX 43 Controller

SenSmart Universal Gas Detector Series

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Industrial Grade Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Dependable Solutions for Gas Detection

Zareba Metro Gas Detector

TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

Oxygen (O2) Single-Point Gas Detection System

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

Touchpoint Plus. A whole new control experience

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

incontrol Systems Inc. Flame and Gas Detection

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

continuous emissions monitoring Combustion & Environmental Monitoring

Two-Channel Gas Controller

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Dräger Polytron 8700 IR Detection of flammable gases and vapors

BX444-Mc Gas Detector

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Dräger REGARD -1 Control System

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 5720 IR Toxic Gas Detection

DB5 Intrinsically Safe Sounder Type DB-5

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Danfoss gas detection Controller unit

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Touchpoint Pro Flexible Gas Control System

Excellence in Level Measurement

Transcription:

P R O D U C T D ATA S H E E T www.internationalgasdetectors.com Transmitters Control Systems OLIVER Sensors IGD Accessories TOCSIN 640 Pre-Configured Gas Detection System, CO2, O2 or N2O With all the features of a standard 640 system and pre-fitted with a detector and mains lead. Available with CO2, Oxygen or N2O detection. This version of the 640 is Pre-Calibrated and configured with standard alarms based on HSE document EH40. Ready to use within minutes of delivery with virtually no installation. The clear to read multi-colour display Provides clear indication of alarm status. Green in normal operation, flashing red on alarm and with level indication the system is simple to fit and operate. The built in sounder also provides clear indication of an alarm condition. Alarms automatically reset once the hazard is clear requiring no user input. Clear, Simple to use and effective protection. Idea for use in: Small Surgeries For Oxygen Depletion Monitoring CO2 Detection in Horticulture, Brewery Applications Background N2O Monitoring Systems are shipped with factory calibration certificates. The gas detectors fitted have long life Infra-red or polymer cells fitted with typical operational life in excess of 5 years. Features Supplied Pre-Calibrated with Detector: CO2, Oxygen or N2O Easy to Wall Mount Pre-Fitted With Mains Lead Expand Later as Required With Additional Detectors: CO2 O 2 N2O Relay Outputs as Standard 4-20mA Output as Standard RS485 Modbus as Standard Control up to 24 Devices as Gas Detectors or I/O Modules LCD Display With Multi Colour Backlight, Flashes Red on Alarm, Flashes Yellow on Fault etc E-Stop Input (System Configurable) Dedicated Interlock to Fire Systems (System Configurable) OLIVER International Gas Detectors H2SCO2 CH4 NO 2 SO2NOCO Triton House Crosby Street Stockport SK2 6SH England IGD Tel: +44 (0)161 483 1415 Fax: +44 (0) 161 484 2345 Email: sales@internationalgasdetectors.com Website: www.internationalgasdetectors.com REF T10-LPG-23R-V1.06 FS646773 Ref: ROS641C

Issuers name and address: EC Declaration of Conformity Declares that the product listed as: Oliver IGD Limited of Triton Hous, Crosby Street, Stockport, Single or Multi-Channel Detector Control Panel Combined Sk2 6SH with a Gas Detector England Are in conformity with the provisions of the following European Directive(s) when installed, operated, serviced and maintained in accordance with the installation and operating instructions contained in the product documentation. TOC-640 2004/108/EC 2006/95/EC EMC Directive Low Voltage Equipment Directive (note not applicable to 24V DC Powered Versions) And that the standards and/or technical specifications referenced below have been applied or considered. Electrical apparatus for the detection and measurement of flammable gases, general EN 61779-1:2000 requirements and test methods. Electrical apparatus for the detection and measurement of combustible gases, toxic gases or Oxygen: requirements and tests for apparatus using software and or digital technologies. Excluding requirements for SIL EMC Generic standards. Immunity for industrial environments EN 61000-6-2:2005 EN 61000-6-4:2007/A1:2011 EMC Generic standards. Emission standard for industrial environments EMC Limits. Limits for harmonic current emissions (equipment input current 16 A per phase) EN 61000-3-2:2014 EMC Limits. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage EN 61000-3-3:2013 supply systems, for equipment with rated current 16 A per phase T640-TF9 Technical File Reference EN 50271:2010 Product Markings TOC-640 Oliver IGD Limited Operate and Independently assessed ATEX/IECEX QAN. Quality Assurance Certificate Number ExVeritas 16PQAN0014 Quality Assurance Notification Number: 2585 ExVeritas, Units 16-18, Abenbury Way, Wrexham Industrial Estate, Wrexham, UK, LL13 9UZ S/-serial number Oliver IGD Limited operate an independently assessed Testing Agency: ISO9001:2008 Quality Management System. TUV - SUD Octagon House Concorde Way Quality Management Certificate Number PO 15 5RL FS 646773 Fareham BSI Assurance UK LTD, Chiswick High Road, London W4 4AL UK TUV Certificates and reports can be checked on-line at https://www.tuev-sued.de/industry_and_consumer_products/certificates Issued on: 20th Feb 2016 At Oliver IGD Limited, Stockport, SK2 6SH, United Kingdom Signature: Declaration of Conformity in accordance with EN ISO/IEC 17050-1:2010 Name Andrew J Collier M.I.O.D Position: Managing Director Date: 20th Feb 2016 Declaration Ref: TOC-640-DEC-2

REAR VIEW 30 REAR VIEW WALL MOUNTING POINT DETAILS 4.5mm SCREWS IF NOT USING FOOT MOUNTS 23 122 14 108 4 REAR ENTRY KNOCK OUTS 20mm DIA SIDE VIEW PANEL MOUNT VERSION (CLAMP) FRONT VIEW 84 79 18 PANEL CUT OUT 141 136 Optional Battery Backup Kit PN 5686601 201 3M Mains Lead Note this module uses the same style enclosure as the TOCSIN 640 and houses batteries and charge control. It is usually mounted below the TOC-640 and is supplied with all required connectors.

ORDER CODES TOCSIN 640 Controller 110/230V AC FOR CO2 TOC-640-CO2 TOCSIN 640 Controller 110/230V AC FOR O2 TOC-640-O2 TOCSIN 640 Controller 110/230V AC FOR N2O TOC-640-N2O Controller Panel Mount Kit 5686401 Battery Backup Module 5686601 Combine Controllers With Detectors and I/O Nodes as Required TOC -BBU BATTERY BACKUP RUNNING ON MAINS Use with TOC-30 Series Detectors and I/O modules. ABS housed detectors sealed up to IP65 rating. RUNNING ON BATTERY This detector series is standard 2 gang mount for surface, flush mounting or mounting to dado rail. Interface to TOC-30 Series annunciators for additional I/O functions. The smart alternative to beacons, sounders and slam switches. Use with Tocsin 103 Series detectors. IP Rated steel enclosures for harsh industrial environments. Use with Tocsin 102 Series detectors for hazardous area applications requiring ATEX approved equipment Interface to TOC-20 Series Infra Red CO2 Sensors. Reliable accurate CO2 monitoring with humidity and temperature readings. Flammable Gas Detection Toxic Gas Detection Oxygen Depletion Protecting People Since 1917

Standard Specifications Power 110/230V AC 50/60Hz 25W Standard 24V DC Option Construction ABS Display 2 Lines x 8 Digit LCD Display Multi-Colour Backlight (Red-Alarm, Yellow-Fault, Blue-Normal) User IGD Jog Wheel Option Select Outputs 3 off SPCO Relays 4A Non-Inductive User Configurable 1 off 4-20mA Linear Output User Configurable Other I/O Sounder 80dB @ 100mm (Mutable) RS485 Port Modbus Dedicated E-Stop Input Dedicated Fire System Interlock Inputs Up to 24 off Addressable Series Detectors or I/O Modules Note external Booster PSU may be required Temperature -5 to 55 Deg C Humidity 0-95% RH Non-Condensing Sealing IP54 Mounting Wall Mount, Panel Mount Kit Option, Duct Mount Kit Option Weight 840g Sensor Accuracies & Response Times Standard Ranges Sensor Response times and accuracies are determined by the type of sensor used. The following table provides general guidance for tests carried out by IGD at standard conditions. Type Ranges Available State When Ordering Type T90 Response Accuracy CO2 Infra Red Pellistors <10s +/-2% LEL 0-5000ppm 0-2% 0-5% Infra Red <15s +/-2% of Range Oxygen Electrochemical 0-25% Electrochemical <30s as CO,H2S,SO2 +/-2% of Range N2O Infra Red 0-1000ppm as O2 <15s as NO2,CL,NH3 <50s