RADIUS BZ1 AREA MONITOR. Product Guide

Similar documents
VENTIS PRO SERIES. Product Guide

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

An easy and flexible way to do gas detection.

ALTAIR 5X Multigas Detector

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector Product Specification

GasAlertMicroClip X3 Specifications

GAS DETECTION & RESPIRATORY PROTECTION

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

BM25 and BM25 Wireless

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

ULTIMA X5000. MSAX5000.com

MSA Portable Gas Detection

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Monitores Personales. Personal Monitor

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5000 Multi-Gas Detection

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

G-TECTA TM. Portable Gas Detection Instruments

OLC(T) 100 FIXED GAS DETECTOR

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Product Manual. The Essential Guide for Safety Teams and Instrument Operators

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Hazardous Gas Detection System. [ for Homeland Security ]

Dräger X-am 2500 Multi-Gas Detection

Transmitters/Sensors. OLCT Series

Polytector III G999 for Ex zone 0

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Choosing the best confined space gas detector

SAFESITE Multi-Threat Detection System

Safe Operation Manual. Honeywell IQ Force Gas Detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

MicroRAE. Wireless, Portable Four-Gas Detector. Gas Detection

IT S WHAT S INSIDE THAT COUNTS

3M Oldham OLCT 100. Description. Fixed Gas Detector

Sieger Apex. Flexibility that meets your requirements

IT S WHAT S INSIDE THAT COUNTS

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

S5000 Gas Monitor. GMS5000.com

Neotronics Impact & Impact Pro

Thank You for Attending Our February Webinar:

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

GAS DETECTION AND MONITORING SOLUTIONS

Dräger X-am 5000 Multi-Gas Detector

Dependable Solutions for Gas Detection

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Dräger X-am 2500 Multi-Gas Detector

IT S WHAT S INSIDE THAT COUNTS

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

altair 2X Gas Detectors

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

MSA XCell Sensors. Because every life has a purpose

ALTAIR 2X Gas Detectors It s what s inside that really counts

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

IT S WHAT S INSIDE THAT

altair 2X Gas Detectors

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Understanding the practicalities of using gas detectors in confined spaces

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Operator s Manual. 1, 2, 3, and 4-Gas Detector

Product Manual. The Essential Guide for Safety Teams and Instrument Operators. Edition 3 March 23, 2016 Part Number:

Dräger X-zone 5500 Area Monitoring

AreaRAE Plus Wireless, transportable area monitor Visibility on more gas threats than ever all in one versatile, easy-to-use device.

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

For the Safety of Your

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger Polytron 8000 Stationary gas detector (EC)

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Dräger Pac 8000 Single-Gas Detection Device

PROTÉGÉ ZM SINGLE GAS MONITOR

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

WATCHMAN MULTIGAS MONITOR

Toxic Gas Detection. Model F12. Toxic Gas Detection

Operator s Manual. 1, 2, 3, and 4-Gas Detector

multi-gas detector Go the distance, and save Wear yellow. Work safe.

MX6 ibrid. Multi-gas Monitor Operation Guide. Part Number: Revision 14

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger Pac 7000 Single-Gas Detection Device

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Why Wireless Gas Detection?

GAS DETECTOR ST400EC PART.NO

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MeshGuard and MeshGuard Gamma

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

SERVING EASTERN CANADA FOR OVER 25 YEARS! Gas Detecion. MicroRAE

Honeywell Analytics. Order List BW Clip & IntelliDoX

Transcription:

RADIUS BZ1 AREA ONITOR roduct Guide

Is Your Worksite READY FOR THE OENT? Stop worrying about missing alarms. Stop stressing over equipment downtime. The Radius BZ1 is built to detect gas hazards 24/7 without the hassle of elaborate wireless setups and maintenance routines. Radius just works, no questions asked, so your teams can focus on what s important and be confident that their area monitors are ready for whatever comes their way. eet the New Face of AREA ONITORING

Deploy Whenever and Wherever Whether setting up a perimeter, or monitoring leaks or confined spaces, the Radius BZ1 allows for flexible deployments to create buffers between workers and gas hazards. Get the essage oud and Clear oud audible alarms and different colored strobes for gas and non-gas events ensure workers not only know when the instrument is alarming, but why. Communicate gas hazards during emergency response, long-term projects, or while performing routine worksite maintenance by adding area monitors wherever they are needed. Deploy monitors for temporary work without worrying about battery life. The Radius BZ1 is the longest running area monitor on the market with 7 days (168 hours) of typical battery life and the option to extend it to over a month using the external power supply. Accurately detect gases regardless of environmental conditions and avoid false alarms thanks to the 360-degree gas path and all-weather sensor deployment. Grab workers attention with audible alarms that sound at 8 db at 1 m to cut through high-noise environments. Easily distinguish between critical and non-critical events based on ultra-bright blue and red lights and differing alarm tones. Know what hazards are present without getting too close thanks to a display that is three times larger than its nearest competitors. Focus on taking action in emergency situations with custom alarm action messages like EVACUATE or VENTIATE.

Know What is Happening Without Approaching Hazards Know more, without buying more, thanks to optional NS Wireless the first wireless platform that allows area monitors and personal monitors to share gas readings and alarms. Create wireless networks out of the box, with no setup or extra equipment needed, thanks to NS Wireless and its automatic, peer-to-peer mesh network. Receive alarms and real-time gas readings from any other instrument on the network. Get long-range communication, up to 300 m (~1,000 ft) between units, with minimal impact on the instrument s best-in-class run time. See gas readings and alarms from Ventis ro Series personal monitors that have joined the wireless group. Spend ess Time anaging Your Instruments Your instruments will spend more time in the field and less time in the shop thanks to a unique modular design, the DSX Docking Station, and patented DualSense Technology. Automatically bump, calibrate, manage settings, and update software for the removable, patent-pending SafeCore odules using DSX Docking Stations. Have confidence that gas readings are accurate and workers are safe, even when instruments are deployed for an extended period without maintenance, thanks to the redundant sensors in patented DualSense Technology. Configure your monitors, in your language, using textbased menus.

entane entane entane entane entane entane entane entane entane entane How Will You Use Your Radius BZ1? Area monitors are a highly flexible solution because they can be placed in temporary or long-term configurations based on your specific hazards. With the addition of NS Wireless, networks are created out of the box and provide visibility into gas hazards that are happening in any location. 1 Confined Space onitoring Know what s happening in a confined space by using the pumped SafeCore odule and tubing to draw air samples to the monitor. 2 erimeter onitoring Set up monitors around a tank, hot work, or other known hazardous areas to continuously 3 monitor for gas leaks. 1 3 Fence ine onitoring Create a barrier between a safe zone and hazardous work area. Use the hopping capability of NS Wireless to know what is happening up to 1.5 km away. 2 NS Wireless Highlights: No infrastructure required Out-of-the-box operation No need for IT setup Self-forming, self-healing networks ong-range communication up to 300 m (~1,000 ft) without sacrificing runtime View peer readings from Radius BZ1 Area onitors and Ventis ro Series personal monitors within a group www.indsci.com/radius

SECIFICATIONS* WARRANTY: Two-year warranty, including sensors and battery KEYAD: Three buttons DATA OG: At least 3 months at -second intervals EVENT OGGING: 60 alarm events INGRESS ROTECTION: I66 CASE ATERIA: Impact-resistant polycarbonate alloys DIENSIONS: 29 x 29 x 55 cm (11.5 x 11.5 x 21.5 in) WEIGHT: 7.5 kg (16.5 lb) TEERATURE RANGE: -20 C to 55 C (-4 F to 131 F) HUIDITY RANGE: 15-95 non-condensing (continuous) DISAY/READOUT: 11.2 cm (4.4 in) monochrome backlit graphical liquid crystal display (CD) OWER SOURCE/RUN TIE: Rechargeable nickel-metal hydride (NiH) battery pack 7 days (168 hours) typical @ 20 ºC, without pump, with wireless 3.5 days (84 hours) typical @ 20 ºC, with pump, with wireless 30 days (720 hours) typical @ 20 ºC, electrochemical sensors only, without pump, with wireless 8 hour recharge time AARS: 8 decibel (db) at 1 m (3.3 ft) redundant audible alarms Redundant, visual alarm Ds (red and blue) SENSORS: Up to 6 sensors (catalytic bead, photoionization detector, and electrochemical) Up to 7 simultaneous readings EASURING RANGES: CATAYTIC BEAD Combustible Gases: ECTROCHEICA Ammonia (NH 3): Carbon onoxide (CO): Carbon onoxide (CO High Range): Carbon onoxide (CO/H 2 ow): Carbon onoxide/hydrogen Sulfide: Chlorine (C 2): Hydrogen (H 2): Hydrogen Sulfide (H 2S): Hydrogen Cyanide (HCN): Nitrogen Dioxide (NO 2): Oxygen (O 2): Sulfur Dioxide (SO 2): 0-0 in 1 increments 0-500 ppm in 1 ppm increments 0-1,500 ppm in 1 ppm increments 0-9,999 ppm in 1 ppm increments 0-1,000 ppm in 1 ppm increments CO: 0-1,500 ppm in 1 ppm increments H 2S: 0-500 ppm in 0.1 ppm increments 0-50 ppm in 0.1 ppm increments 0-2,000 ppm in 1 ppm increments 0-500 ppm in 0.1 ppm increments 0-30 ppm in 0.1 ppm increments 0-150 ppm in 0.1 ppm increments 0-30 vol in 0.1 increments 0-150 ppm in 0.1 ppm increments HOTOIONIZATION Volatile Organic Compounds (.6 ev): 0-2,000 ppm in 0.1 ppm increments U: Optional integral pump, up to 30.48 m (0 ft) sample draw WIRESS: Optional NS Wireless, proprietary mesh network Frequency: IS license-free band (2.4 GHz) ax eers: 25 devices per network group independent, configurable network groups Range: 300 m (~1,000 ft) line of sight Encryption: AES-128 Approvals: FCC art 15, Others** CERTIFICATIONS: U: Class I, Division 1, Groups A, B, C, and D; T4 Class 1 Zone 0 AEx da ia IIC T4 Ga1 CSA: Class I, Division 1, Groups A, B, C, and D; T4 C22.2 No. 152 applies only to thermo-catalytic reading ATEX: Ex da ia IIC T4 Ga, Equipment Group and Category II 1G IECEx: Ex da ia IIC T4 Ga SUIED WITH ONITOR: Calibration cup (without pump), sample tubing and pump inlet water barrier (with pump), product manual, hand tool, charging power supply and region-specific cord REFERENCE GUIDE ANGUAGE: English, French, Spanish, German * These specifications are based on performance averages and may vary by instrument. ** See www.indsci.com/wireless-certifications for country-specific wireless approvals and certifications.

Ready for the oment, Day and Night Test drive the Radius BZ1 with the INSTRUENT SIUATOR www.indsci.com/radius-simulator Build and price your Radius BZ1 online with the INSTRUENT BUIDER www.indsci.com/ radius-builder

www.indsci.com/radius AERICAS hone: +1-412-788-4353 Fax: +1-412-788-8353 1-800-DETECTS (338-3287) North America info@indsci.com ASIA ACIFIC hone: +65-6561-7377 Fax: +65-6561-7787 info@ap.indsci.com EEA hone:+33 (0)1 57 32 92 61 Fax: +33 (0)1 57 32 92 67 info@eu.indsci.com