PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Similar documents
PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

RFID Card Access Control Unit. Operating Instructions

Installation Guide & User Manual

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

DOLKPS1KB Programming & Installation Manual

WIRING DIAGRAM AND INSTRUCTIONS

DOLKPL1KB DOLKPS1KB DOLKSF1KB

Operating instructions 2-channel code lock. Item No

User Manual X8s Access Control System

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

ELT-KLED EliteSuite LED Keypad Installation Manual

Operating Instructions Transponder code lock - Part 2 (split decoder)

HAA2866 HAA2866 ERRATUM

C2 Compact Range Installation & Programming Manual

General Purpose IO Technical Manual

SPLIT-DECODED CONTROLLER

Installation & User Manual V2.03

Model 4880 Status Output Display Module Manual

Transponder reader TECHNICAL SHEET (White) (Magnesium)

NX-148 LCD CODE PAD TABLE OF CONTENTS

Condominium Security Management System

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD AND CARD READER

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Sentry 4 Zone Alarm Panel User Manual

1. Introduction. 2. Product overview

Power Locking Installation Manual

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

User Manual. Dryer Controller M720

GSM RFID VOICE Alarm System

G34 AU1B (External Ultrasonic Sensor) Version 3

CORNELL Emergency Response Systems

PROGRAMMING PROCEDURES (Table 3)

SR-i500 INSTALLATION MANUAL AND USER S GUIDE. FM 2-Way Security System. Setting Clock Time. Setting Alarm Clock. FCC Notice

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

SOLO Installation manual STAND-ALONE PROXIMITY ACCESS CONTROL SYSTEM

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

AXS Strikemaster Engineering Manual

VIDEO CONTROLS LIMITED

HILLS Series LED Code Pad User Manual

Control/Communicator Installation Manual

Exit Stopper. STI-6400 Series

Strikemaster ES Engineering Manual

BSR Addressable Fire Detection control panel. Installation operation manual

GV2 Series Control Panels

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

Сontrol panel Contact GSM-9N

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

HILLS Series LCD Code Pad User Manual

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Ultra-8D. ControlPanel. Operators Manual. Advanced DigitalControls CP108-0M-V1

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Exit Stopper. STI-6400 Series

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

Solution 880 Operators Manual. Issue 1.00

Solution 862 Installation Manual ISSUE 1.30

Advisor Advanced User Guide

Installation Instructions

SECURIT 700L PLUS ENGINEERING MANUAL

Installation & Programming Guide

Dryer Controller M720

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

Addendum for STI-6406 with Dual Access Control

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

CC408. Quick Reference Guide Solution 880

MO144. Operators Guide. Universal Timer Module

SCR100 User Manual. Version:1.1 Date:Dec 2009

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Pump-Up Controller MODEL 4062

PIN & Proximity, PINPAD Single Door Access Controller USER S MANUAL. PIN & Proximity, PINPAD Single Door Access Controller Rev Rev.2.1.

ZM1 User Manual JVA TECHNOLOGIES.

Gmini 100. User Guide INTELEC SYSTEMS Intelligent Electronic Systems. Web:

WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Table of Contents. Appendix A Special Characters 31

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Installation Instructions

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Pump-Down Controller MODEL 4052

Installation Manual RINS1211-4

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

Version 1.03 January-2002 USER S MANUAL

Wireless Keypads LKP(E)S8M Series

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Model: M30. Owner s Operation Manual. For correct operation, please read this manual to familiarise yourself with the features.

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

GE Security. ATS1250/ door DGP / 4-lift DGP. Installation guide

Transcription:

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Contents I. SPECIAL FEATURES 1 II. FRONT PANEL 1 III. INSTALLATION PROCEDURES AND PROXIMITY CARD TYPES 2 IV. SETTING MODE AND FUNCTIONS 3 1. Add Proximity Card(s) 3 2. Delete Proximity Card(s) 4 3. Add / Change User Pass Code 4 4. Door Lock Time Setting 5 5. Setting Door Access Entry Mode 5 6. Batch Registration (Adding Sequential Card Series) 6 7. Anti-Tamper Output 6 8. Change System Code 7 9. Delete User Pass Codes 7 10. Delete All Proximity Cards 8 11. Door Access Using System Code 8 V. INSTALLATION OF PROXIMITY READER 9 1. Connections 9 2. Installation of electric lock and exit push button 10 3. Installation of door sensor, external relay and siren 11 VI. PRECAUTIONS 12

ST-320 Mode Setting I. SPECIAL FEATURES: 1. Stand alone operation. 2. Front panel power-on indicator. 3. Four door opening modes. ENTRY MODE 1: 4-digit Pass Code only. ENTRY MODE 2: Proximity Card access only. ENTRY MODE 3: Proximity Card plus 4-digit Pass Code. ENTRY MODE 4: Proximity Card or 4-digit Pass Code 4. Programming Mode is protected by a 4-digit System Pass Code. 5. All Proximity Cards must be registered prior to use. 6. Maximum storage of 2000 cards. 8. Non-volatile memory protects against data loss. II. FRONT PANEL AND PROXIMITY CARD TYPES Indicator Lights Status Light: Yellow Status Light: Status Light Bar: Function Flashes to indicate panel key press. On to indicate Programming Mode. Off in Normal Mode. Flashes to indicate unsuccessful access. On when alarm is active. Red - Power on in Normal Mode. Indicates successful access. Pass Code Entry and Programming Mode. Ten Numeric Keys 0-9: # Key: Confirmation Key * Key: Clear or Escape Key Indicator Yellow Indicator Status Light Bar Clear / Escape Key 1 2 3 4 5 6 7 8 9 * 0 # Confirmation Key Door Bell

Proximity Cards Proximity Cards will have either a single 8-digit number or an 8-digit number separated by a comma and a 10-digit number in the center of the card. The ST-320 uses only the last 6-digits of the 8-digit number printed on either card type. 0008502004 131,00050 04110022 Last 6-Digits 502004 Last 6-Digits 110022 III. INSTALLATION PROCEEDURES 1. Refer to Appendix for mounting instructions. 2. Do not install Proximity Reader on or near metal objects, this will reduce the effective range of Access Card detection. 3. Install the appropriate connector(s) to meet door access application requirements. See the examples located on page 10 and 11. 4. Connect power to the reader. 5. The Status Light Bar should turn on Red and a single BEEP will sound. If the unit is not attached to the mounting plate, the Yellow Status Light will be on, indicating an alarm condition. The alarm is caused by the Anti-Tamper Switch on the rear of the unit.

IV. SETTING MODES AND FUNCTIONS ** Programming Mode Default System Pass Code: 4567 ** The system is factory preset for Entry Mode 2 Proximity Card Access Only. If another Entry Mode is desired, proceed to Function 5 prior to adding Proximity Cards or Pass Codes. To enter into the Programming Mode, press the following keys in sequence: * # 4 5 6 7 # After the last # in the sequence the system will once and the Status Light will be on. The system will exit the Programming Mode automatically if no keys are pressed within 20 seconds. The user can exit the Programming Mode any time by pressing the * key. 1. Add Proximity Card(s) 1 6-Digit *** Proximity Card Code Card Code Accepted Next Card * Terminate Card Code Failed 3 Duplicate Card * Terminate *** Placing the Proximity Card to be entered within the readers detection range instead of entering the 6-Digit Card Code can also register single cards. This feature will only function for individual card entry and not in the Batch Registration (Function 6) mode.

2. Delete Proximity Card(s) 2 6-Digit Proximity Card Code Card Code Deleted Next Card * Terminate Card Code Delete Failed 3 Duplicate Card * Terminate 3. Add / Change User Pass Code The System allows up to 8 different User Pass Codes to be programmed. Each Pass Code must be a 4-digit number. The 4-digit Pass Code alone can allow door access (ENTRY MODE 1) or be used in combination with a Proximity Card. 3 Pass Code Location ( 1 8 ) 4-digit Pass Code Pass Code Accepted * Terminate

4. Door Lock Time Setting This setting determines how long the electronic lock is active after door access. The time can be set between 01 99 seconds (must use 2-digits). Set 99 seconds for toggle state (suitable for security system). 4 2-Digit Time Duration ( 01 99 ) Time Accepted Complete 5. Setting Door Access Entry Mode There are four Door Access Entry Modes available in the ST-320. The unit is factory preset for MODE 2, Proximity Card Access only. ENTRY MODE 1: 4-digit Pass Code only. ( 4-digit Pass Code for door access) ENTRY MODE 2: Proximity Card access only. (Present Proximity Card for door access) ENTRY MODE 3: Proximity Card plus 4-digit Pass Code. (Present Proximity Card and enter 4-digit Pass Code within 5 seconds) ENTRY MODE 4: Proximity Card or 4-digit Pass Code (Present Proximity Card or enter 4-digit Pass Code) 5 Door Entry Mode ( 1 4 ) Complete

6. Batch Registration (Adding Sequential Card Series) A sequential series of Proximity Cards can be quickly added to the system with this function. the lowest 6-digit Card Code followed by the amount of cards in the sequence. the amount of cards using a 4-digit value (75 cards = 0075) 6 First 6-Digit Proximity Card Code Card 4-Digit Quantity 0001-2000 2 * Terminate 7. Anti-Tamper Output The system has an output dedicated to the detection of Forced Entry of the access door (door contacts) and removal of the system from its mounting plate (Tamper Switch). The Function can be set whether to include Forced Entry detection or not. The system Tamper Switch will always activate the Anti-Tamper output. 0 to include Forced Entry detection. 1 to ignore. 7 0: Include 1: Ignore 2 Complete

8. Change System Code The factory default System Pass Code: 4567 The new 4-digit Pass Code value must be entered twice. 8 new 4-digit System Code XXXX # REPEAT new 4-digit System Code XXXX # System Codes Match 2 Complete # System Codes Do Not Match 4 Terminate 9. Delete User Pass Codes This function will delete ALL 8 User Pass Codes. 9 3 Complete

10. Delete All Proximity Cards This function will delete ALL Proximity Cards stored on the system. The Status Light will flash up to 20 seconds while function is executing. 9 9 Status Light Flashing 2 Complete 11. Door Access Using System Code 0 0 Door Access Complete

V. Installation of Proximity Reader: 1. Connections: Red Anti-Tamper Switch, Common Contact 8-Pin Connector Black Brown Orange Yellow Anti-Tamper Switch, NO Contact Not Used Anti-Damage "Forced Entry" Alarm Output Duress Alarm Output Door Contact Sensor 1 Blue Purple Door Contact Sensor 2 GND Red +12 VDC 6-Pin Connector Brown Blue GND Door Control Relay, Contact (NO) Door Control Relay, Contact (NC) Purple Yellow Door Control Relay, Contact (COM) Exit Push Button 2-Pin Connector Blue Blue Door Bell Switch Door Bell Switch Door Control Relay, Contact Rating: Anti-Tamper Switch Contact Rating: Door Bell Switch Contact Rating: 12 VDC @ 3 A 24 VDC @ 0.5 A 110 VAC @ 3 A

2. Installation of electric lock and exit push button: ELECTRIC LOCK: FAIL SECURE EXIT PUSH BUTTON ELECTRIC LOCK Yellow Purple 6-Pin Connector Blue + 12 VDC Brown Red + 12 VDC ELECTRIC LOCK: FAIL SAFE EXIT PUSH BUTTON ELECTRIC LOCK Yellow Purple 6-Pin Connector Blue + 12 VDC Brown Red + 12 VDC Note: (1) Fail-Secure type lock: Connect to 6-pin connector, Purple and points. (2) Fail Safe type lock: Connect to 6-pin connector, Purple and Blue points. (3) Use dry contact only for Exit Push-Button (4) Proximity reader power consumption: Standby = 90mA / Active = 110 ma DO NOT SHARE THE SAME POWER SUPPLY WITH THE ELECTRIC LOCK AND PROXIMITY READER.

Red Orange Yellow Black Brown Yellow Blue Purple Red Brown Blue Purple Red Orange Purple Yellow Black Brown Yellow Blue Red Brown Blue Purple 3. Installation of door sensor, external relay and siren: A. Installation of reed switch (normal close), external relay "Forced Entry" (anti-damage) 6-Pin Connector 8-Pin Connector Door Reed ( NC ) COM NC External Relay Siren NC NO COM + 12 VDC B. Installation of reed switch (normal open), external relay (duress) 6-Pin Connector 8-Pin Connector Door Reed ( NO ) COM NO External Relay Siren NC NO COM + 12 VDC

Note: (1) The system provides two external relay connection points: a. Forced Entry anti-damage (tamper switch and door sensor) alarm output connection point. (8-pin Orange wire) b. Duress alarm output connection point. (8-pin Yellow wire) (2) If door sensors are connected, be sure to enable Function 7 (Anti-Tamper Output). (3) The door sensor (Anti-Tamper Output) alarm will activate if the door is not closed within 30 seconds after a valid card or code access. (4) The Duress alarm output can be activated by pressing * prior to entering 4-digit Pass Code. (5) Alarms can be cleared by entering the Programming Mode, presenting a valid Access Card or entering a valid User Pass Code VI. Precautions 1. Prior to installation, check the voltage and polarity of the power supply to avoid damage to the Proximity Reader. 2. Do not share the power supply with the electric lock and Proximity Reader. 3. Do not install Proximity Reader on or near metal objects, this will reduce the effective range of Access Card detection. 4. Do not attempt any repair or modification of the Proximity Reader.

Appendix

Optional Accessories Goose Neck Stand PED-001 Mounting Adapter Plate PRX320-PAD