Analogue Addressable Fire Panel Range

Similar documents
Analogue Addressable Fire Panel Range

Product Overview Brochure. Flexibility to design a fire system that best suits you

Extending Your Potential. Product Range

ZXSe Range Data Sheet

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Components Brochure DX CONNEXION

Application Guide 001

(Fire) Emergency Evacuation Plan

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

MINERVA MZX125 Digital Addressable Fire Detection System

PREMISES FIRE SAFETY HANDBOOK

ID2000. intelligent fire alarm panel

intelligent fire alarm ID60series panels

UNIVERSITY COLLEGE LONDON PREMISES FIRE SAFETY HANDBOOK. Regulatory Reform (Fire Safety) Order 2005 DARWIN BUILDING

PREMISES FIRE SAFETY HANDBOOK

Honeywell Air Sampling Devices Data Sheet

Medicontrol itcp Intelligent Theatre Control Panels

ID50series. intelligent fire alarm panels

Advanced FireAlarm Panel 1-4Loop

PREMISES FIRE SAFETY HANDBOOK

Honeywell Air Sampling Devices Data Sheet

Intelligent Security & Fire Ltd

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ID3000 intelligent. fire alarm panel

The future of lighting management. Cutting costs and carbon keeping your building compliant.

Report For NHS Shetland

Solution F2. Fire Alarm Control Panels one step ahead.

EMERGENCY EVACUATION PLAN

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

ID3000 intelligent. fire alarm panel

MINERVA MZX125. Digital Addressable Fire Detection System

Addressable Loop Powered Visual Alarm Devices

Wellsprings Primary School. Fire Emergency Evacuation Plan

Different types of Fire Alarm System

Sita200plus. 200detectors. Single loop analogue addressable System

Building Technologies

LightSweep. Lighting Control System

We can help you with the Fire Risk Assessment. What s more, we can help you put your evacuation plans in place.

WILTSHIRE POLICE FORCE PROCEDURE. Fire Safety Management

A Guide To BS Understanding the selection, spacing and siting of detectors

Clino System 99. Intelligent Life Care Integrated Communication Systems for Care Provision

SOUNDER BASES AND SOUNDER BEACON BASES

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Fire Certificate. An issue of Maintenance from the Technical and Legal perspective

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Managing Fire Safety To Ensure Legislative Compliance

Notifier by Honeywell: Non-Addressable Audible & Visual Alarm Devices. Approved to EN54-3/EN54-23

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

FireClass. Introducing a new class of fire detection

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Dangerous Assumptions

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

False Alarm Management

Contents. Morley-IAS by Honeywell. Providing a control panel solution for fire industry professionals.

...your control needs

Welcome to Morley IAS Fire Systems

Security, Efficiency and Comfort with KNX

Building Technologies

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

LEICESTER GRAMMAR SCHOOL TRUST FIRE SAFETY POLICY

Local Rules: Fire Safety

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

Case Study Media Contact Beth Welch, or

Emergency Communications

Fire and Smoke Control Systems

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (All Buildings - Excluding Sleeping Accommodation)

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

At the end of this study topic, you will be able to discuss the legal requirements of the Fire Safety Manager Scheme, and list the statutory duties

Fire Risk Assessment. A safety guide for users of the hall

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING

FP-PGN-14 Part of NTW(O)41 Fire Policy

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

DEF Fire Evacuation and Emergency Planning Criteria

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

NHSScotland Firecode. A Model Management Structure for Fire Safety Version 4. This document forms part of NHSScotland Firecode Edition No

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

You requested information regarding fire risk assessments. Specifically you asked for:

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 PERIODIC REVIEW OF FIRE RISK ASSESSMENT

/ / White Paper. Focusing on user experience

Security & Safety in the Building Automation World. Presented by Gary P. Wright, RCDD, EE, EC Director of Security & Communications

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Product overview. Alarm indicator, operator and display panels

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

Organize your security with PSIM + software

HART XL High Sensitivity Smoke Detection

Organize your security with PSIM + software

Design of Fire safety in Multi Occupancy Residential Accommodation

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

Consultant Specification AGILE Wireless Fire Detection System

The Future of Smart Technology

The Ultimate, Digital Public Address & Voice Alarm System FLEXIBILITY UNLIMITED

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Design Guidelines Fire Safety in New and Refurbished Buildings

Transcription:

Analogue Addressable Fire Panel Range

Why Choose a Morley-IAS Analogue Addressable Control Panel? By choosing a system that utilises a Morley-IAS analogue addressable control panel, the precise location of a fire or fault can be quickly and clearly identified. Analogue addressable sensors connected to the control panel are, in themselves, intelligent devices and capable of reporting far more than just fire or fault conditions. Morley-IAS control panels make full use of the information provided by the sensors. This concise information helps to reduce maintenance costs, protect the site and its occupants at all times, and in the event of a fire, manage the activation effectively reducing unnecessary down time. Why Choose Morley-IAS by Honeywell? The wide range of products from Morley-IAS allows you the freedom to design a system that best suits your needs with the option to create, add and enhance, whenever and however you wish. Our extensive network of trained distributors and installers gives building owners and managers the freedom to choose the installer and/or maintenance provider that best meets their requirements. Beacon Centre for the Blind Wolverhampton

Analogue Addressable, Networkable Fire Alarm Control Panels Available with 1, 2 or 4 Loops 5 button presses and you can have a working fire alarm system. How simple is that? Scenario A London based property developer owns a complex of four, four storey buildings comprising 30 to 40 luxury apartments in each block. The buildings require a fire detection and alarm system to protect the escape routes, common areas, car parks, plant rooms etc. Solution Their Consulting Engineers have proposed the installation of four new Morley-IAS DX Connexion fire alarm control panels, as the panels support Morley-IAS protocol device. The 16 loop, 80 zone capacity of the Connexion s peer-to-peer network provides a simple cost effective solution for their buildings. Additionally, the attractive modern panel facia and large blue LCD display fit well when flush mounted in the luxurious entrances to the apartment blocks. The choice of control panel is welcomed by the electrical contractor who has experienced the simple 5 button set-up routine and intuitive menu structure provided as it reduces his installation and commissioning time significantly. Welcome Break Services London Gateway M1

ZXSe Range Analogue Addressable, Networkable Fire Alarm Control Panels Available with 1, 2 or 5 Loops Scenario Estates Facilities manager Dave Smith needs to link the various fire alarm systems at the County General Hospital. Since most of the buildings are already equipped with Morley ZX analogue addressable fire alarm panels. Solution Following a meeting with Morley s local Business Manager, Dave decides to upgrade the existing Morley ZX control panels and replace others with fire alarm control panels from the Morley ZXSe range. This allows Dave to integrate all of his buildings fire alarm systems and consolidate the site wide information back at the telephone operator s room. The ZXSe range of fire alarm control panels reduces Dave s costs but still meets the fire strategy dictated by the Hospitals Fire Officer. The complex event programming feature of the ZXSe panel makes the integration of the various items of plant and the horizontal phased evacuation required in the Main Hospital Building achievable. Additionally, passive repeater panels sited at nurse stations will provide ward staff with precise information as to the progress of a fire should it occur allowing them to prepare patients well ahead of the need to move them. Hospital Site Networked Schematic MAIN HOSPITAL BUILDING Main Entrance ZX5Se Telephone Ops Room Visualeyez ZX1Se Repeater Accommodation Block ZX2Se Laundry ZX1Se Repeater Outpatients Building ZX2Se

Site-Wide Alarm Management System Scenario Dave Smith also recognizes the need to present clear and concise information as to the status of an alarm event to his telephone operators. Visualeyez assists the operators who make the call to the fire brigade when there is an alarm activation at the County General Hospital. Solution A Morley-IAS PC based Visualeyez alarm management system will assist both the telephone operators and his own engineering staff with the day to day management of the 2500 fire sensors dotted around the hospital, complimenting the recently installed network of ZXSe fire alarm control panels. The Visualeyez alarm management system will additionally allow a remote off-site building that belongs to the hospital to be seamlessly integrated with the rest of the fire alarm system using a Visualeyez Cube unit. The comprehensive software package will help Dave plan and record his maintenance of the fire alarm system and importantly simplify his obligations under the Regulatory Reform Fire Safety Order to maintain adequate documentation. HUBs images supplied by Sheffield Hallam University

DISTRIBUTOR CONTACT DETAILS For further details on these or any other Morley-IAS products please contact your local distributor, your local Morley-IAS Business Manager or please feel free to contact the head office using the details provided below. For further details on these or any other Morley-IAS products please contact your local distributor, Morley-IAS Business Manager or via our contact Every care has been taken in the preperation of this datasheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. Morley-IAS by Honeywell 2011 702, 7th Flr., B-Wing, T: +91-22-6765 0721 Reliable Tech Park, F: +91-22 6765 0730 Thane-Belapur Road, Airoli, E: marcom.hls@honeywell.com Navi Mumbai - 400708 www.morley-ias.co.uk MRLLP: 005-August-13 details found below.