Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

Similar documents
Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance

INSTRUCTION MANUAL CD Fax: (503)

99 Washington Street Melrose, MA Phone Toll Free Visit us at

GAS-Mate. Combustible Gas Leak Detector

Stand Fan. English. Owner s Guide. Model F R

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

H-10PM. Refrigerant Leak Detector

RK/ RK Carbon Monoxide Detector Operator s Manual

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

RK/ RK Oxygen Detector Operator s Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

HAND HELD METAL DETECTOR

RK-02 Multi Point Detector Operator s Manual

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

RK Multi Point Detector Operator s Manual

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

16 Stand Fan with Remote Control Model No: FS3-40R-30

Cordless Electric Broom

RK Carbon Monoxide Transmitter Operator s Manual

RK-05 Combustible Gas Transmitter Operator s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

RK/ RK Combustible Gas Detector Operator s Manual

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

RLD-H10P Refrigerant Leak Detector

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

IMPORTANT SAFETY INFORMATION:

IMPORTANT INSTRUCTIONS READ & SAVE

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

OWNER S GUIDE SV

OWNER S GUIDE SV

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

RK Carbon Monoxide Transmitter Operator s Manual

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

RK CO 2 Transmitter Operator s Manual

D-TEK Select. Refrigerant Leak Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

TEK-Mate. Refrigerant Leak Detector

Whisper. Ultrasonic Leak Detector

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

For technical support call:

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

RK Carbon Monoxide Transmitter Operator s Manual

TEK-Mate. Refrigerant Leak Detector

RK Hydrogen Sulfide Transmitter Operator s Manual

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

IMPORTANT SAFETY INFORMATION:

Infrared Portable Space Heater

LD-5000 REFRIGERANT LEAK DETECTOR

Owner s Manual TDS8515. Model Numbers:

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

RK Combustible Gas Transmitter Operator s Manual

R Series B & T2 Model

Retro Flip Alarm Clock MODEL: CH1200/1/2

NGD8800 USER S MANUAL

ELECTRIC STOVE HEATER Models: FS2213B

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

RK / RK Methane Detector Operator s Manual

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

RK Transmitter Technical Notice

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

CS150 OWNER S MANUAL DISCRIMINATOR METAL DETECTOR

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

BOLT ION 2-IN-1 CORDLESS VACUUM USER GUIDE REMANUFACTURED 1312R. For How-To videos, go to

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

IMPORTANT SAFETY INFORMATION:

750MM INDUSTRIAL PEDESTAL DRUM FAN

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

With Remote Control. English. Model

16 OUTDOOR MISTING FAN

Famous Trails Anaheim, California

18 INCHES, OSCILLATING STAND FAN

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

42 Oscillating Tower Fan with Remote Control. OWNER S MANUAL Model # FC1-42R-03

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

RK/ RK Oxygen Detector Operator s Manual

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower


14 Upright Vacuum with HEPA Filter & Dual Power

User s Manual and Operating Instructions

Use and Care Instructions

COMBUSTIBLE GAS LEAK DETECTOR PEN

Transcription:

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance www.graceindustries.com MCTM1012 October 2012 1

1. Cover 2. Table of Contents 3. Top View 4. Side View 5. Features & Benefits 6. Operation: Turning ON 7. Operation: Adjusting Sensitivity 8. Operation: Scanning for Gases 10. Operation: Electronic Purge 12. Operation: Charging the Battery 13. Operation: Battery Life 14. Maintenance: Battery Maintenance 15. Maintenance: Sensor Maintenance 16. Maintenance: Replacement of Hydrocarbon Sensor 17. Telescoping Investigator s Probe - Optional Equipment for Scanning for Gases/Hydrocarbons 19. Model C Warranty Information Model C Table of Contents 2

Model C Top View Sensor Sheath Sensor Sensor Indicator Light (Red) Belt Clip Purge Indicator Light (Yellow) Ready Indicator Light (Green) ON/OFF & Sensitivity Adjust Control 3

Model C Side View Sensor Mute Switch Purge Switch Audio Speaker Battery Charger Jack Battery Charging Light (Red) 6 Foot Coiled Sensor Cord 4

Model C Features & Benefits Detects approx. 125 toxic/combustible gases and/or vapors including heating gases Adjustable Sensitivity aids in pinpointing the source of high gas concentration Solid State Sensor, housed in a protective guard, with a 6 foot coiled sensor cord Audio and Visual displays indicate the detection of suspect gases Powered by Nickel Cadmium rechargeable batteries with operating time of approximately 8 to 10 hours of use Corrosion resistant, painted steel enclosure Electronic Purge permits quick recovery of sensor element Mute Switch turns off audio tones and permits discreet investigation Applications: Arson Investigation, Leak detection, General purpose gas detection 5

Model C Operation Turning ON Mute Switch Turn the Model C Electronic Nose ON by rotating the ON/OFF & Sensitivity Adjust Control clockwise until a click is heard. This may cause the Audio Indicator to beep in synchronism with the Red Sensor Indicator Light. As the unit warms up, the flashing and beeping will cease. Wait approximately two minutes; the Green Ready Indicator Light will glow when the sensor has reached operating temperature (stabilization). A Mute switch is located on the side of the detector and can be switched ON to silence the audio for discreet investigations. ON/OFF & Sensitivity Adjust Control 6

Model C Operation Adjusting Sensitivity Rotate the Sensitivity Adjust Control knob clockwise until a beeping sound and flashing Red Sensor Indicator Light starts. Then slowly rotate the Sensitivity Adjust Control knob counterclockwise until the beeping action and flashing Red Sensor Indicator Light just stops. The Model C is now ready for use and has a sensitivity of approximately 100 parts per million (ppm) for methane as the test gas. The most sensitive mode of operation may be achieved by rotating the Sensitivity Adjust Control clockwise so that a very slow beep and flash rate occurs. This mode of operation permits the detection of gas concentrations of less than 50 parts per million (ppm). ON/OFF & Sensitivity Adjust Control 7

Model C Operation Scanning for Gases Because the Model C is constantly sampling the atmosphere and is dependent upon (hydrocarbon) aerosol particles or gas molecules to diffuse into the detector, sufficient time should be allowed for this to occur - usually 4 to 5 seconds. When attempting to locate very small leaks or hydrocarbon vapors, slowly scan the area in question, holding the Model C at a 45 degree angle and one inch from the area being examined. When gas or accelerants are detected, the audio and visual indicators will beep and flash in synchronism. Beep and flash rates will increase when higher concentrations of gas/hydrocarbons are discovered. 8

Model C Operation Scanning for Gases Consideration must be given to factors such as time, temperature and relative humidity. Most accelerants/hydrocarbons are more pronounced as aerosol particles on warm, dry days than on cold, damp days. These factors will influence the volatility of hydrocarbons. If there is an area of suspicion and you do not get a reading, put the Model C in its most sensitive mode (indicated by a very slow beep and flash rate) and observe if any change in beep rate occurs upon further investigation of the suspect area. 9

Model C Operation Electronic Purge The Electronic Purge feature permits a rapid recovery of the sensor element. After the Model C has detected the presence of an accelerant, simply slide the Purge Switch to the ON position; the Yellow Purge Indicator Light will glow. Leave the Purge Switch in the ON position for 15 to 30 seconds. There will be a rapid beeping sound as the sensor burns off residual vapors. After 15 to 30 seconds, slide Purge Switch to OFF position. The unit will rapidly cease to annunciate and the detector is now ready to detect another sample. Purge Switch Turn Purge Switch OFF before attempting to detect another sample. 10

Model C Operation Electronic Purge The Purge Switch may also be used to speed the warm-up period when the unit is initially turned on. When the Purge Switch is in the ON position, the detector s circuits are disabled and the Model C will NOT detect the presence of gas or accelerants in this mode. Turn Purge Switch OFF before attempting to detect a sample. Purge Switch 11

Model C Operation Charging the Battery To charge your Model C: Turn unit OFF and insert charger plug into the Battery Charging Jack on the side of the unit. Plug the charger/adapter into power source/outlet. Battery Charging Indicator Light will glow Red while the unit is charging. Charging Jack Plug Adapters Provided 12

Model C Operation Battery Life Charge Model C for 12 hours to fully charge battery. Operating time for a fully charged battery is approximately 8 to 10 hours. When battery power is low, a slow beeping sound will start. Note: the low-battery indication is audio only. Plug Adapters Provided 13

Model C Maintenance Battery Maintenance For optimum performance from your Model C, the following procedures are recommended: Be certain the Model C is used a minimum of ten (10) hours per month, preferable several hours each week. If the unit is used less than ten hours, the following procedure should be observed to maintain peak performance. Turn the unit ON and let the battery completely discharge. When battery power is low, a slow beeping sound will start. Let the battery fully discharge before turning the unit OFF and recharging the battery. Note: the low-battery indication is audio only. This procedure conditions the battery for maximum power and also re-sensitizes the sensor by removing any absorbed gases that may have absorbed into the sensor. 14

Model C Maintenance Sensor Maintenance Avoid getting debris or foreign material in the sensor. If the sensor becomes contaminated, let the unit warm up and then lightly tap the sensor over a white piece of paper and observe if any material is dislodged. The white paper will readily show any foreign debris that may have been lodged in the sensor. If the sensor should accidentally become submerged in liquid, let the sensor dry out for 24 hours. Turn unit ON for 8 hours until the battery is exhausted. Charge the battery and repeat above procedure. 15

Model C Maintenance Replacement of Hydrocarbon Sensor Remove damaged or malfunctioning sensor from the socket located in the sensor housing at the end of the coiled cord. Use a small screwdriver to carefully and incrementally loosen the sensor from the socket. Once it is loose, pull the sensor out of the sensor housing. 16

Model C Maintenance Replacement of Hydrocarbon Sensor Plug in new replacement sensor by carefully aligning the sensor pins into the socket. 17

Model C Maintenance Replacement of Hydrocarbon Sensor Gently and firmly press the replacement sensor into the socket until it is secure. Allow for required warm-up period (approximately two (2) minutes) before use. 18

Telescoping Investigator s Probe Optional Equipment for Scanning for Gases/Hydrocarbons Using the Telescoping Investigator s Probe is helpful when scanning low or hard to reach areas. Remove pin from probe, insert sensor end of the Model C into the end of the probe as shown and replace the pin. Extend probe to desired length and scan area of concern. Pin 19

Telescoping Investigator s Probe Optional Equipment for Scanning for Gases/Hydrocarbons The probe is 43.5 inches long when fully extended; and the probe collapses down to 19 inches for storage. Use for investigating fire scenes, manholes, gas distribution lines, locating accidental gasoline spills in sewer system and other low or hard to reach areas. Pin 19 inches long when collapsed 43.5 inches long when extended 20

Model C Warranty Information Grace Industries, Inc. warrants Grace Industries, Inc. portable hydrocarbon detector Model C to be free from defects in workmanship and materials for a period of one year from the date of purchase. Grace Industries, Inc. will not repair or replace any merchandise under warranty which has been damaged because of accident, misuse or abuse while in possession or control of the consumer. This warranty is void if any attempt to repair or replace parts was made or attempted by other than qualified Grace Industries, Inc. personnel. This warranty is void if any of the sealed compartments are opened or tampered with. Send all returned merchandise, prepaid to: Grace Industries, Inc., Repair Division, 305 Bend Hill Road, Fredonia, PA 16124 USA. Grace Industries, Inc. shall not be liable for any direct, incidental or other consequential loss or damage arising out of the failure of the product to operate. 21

Model C Electronic Nose Accelerant and Gas Detector www.graceindustries.com MCTM1012 October 2012 22