INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

Similar documents
G&F Manufacturing Service Manual Version 2.0 April 2010

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

Owner s Manual for Swimming Pool Heat Pump

Owner s Manual PRINTED IN CANADA 05/2009

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

Quick Start Guide. For product manuals and further installation / operation procedures visit

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

Notice: Please remove these instruction from the Electrical area and store with proof of purchase. Ground. L1 L2 Bond 208V (2) COM (5) (1) 230V

Heat Pumps. English. Models: M1, M2, M3, M4, M5. User Manual

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

LF Readout Displayed on LED. Compressor Stops Fan Runs. 1 Hour Time INFORMATION. Delay Activates

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

OPERATING INSTRUCTIONS

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

AquaCal Operation Manual

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

AquaCal Installation Manual

This manual should be maintained in legible condition and kept adjacent to the heat pump pool heater or in a safe place for future use.

AquaCal Operation Manual

AquaCal Operation Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Smart Temp. Model

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

Operator: Save these instructions for future use!

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

POOL & SPA HEAT PUMP OWNER S MANUAL

No fan function in heat mode. Fan ON continuously. Indicates incorrect room temperature

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

CAUTION. Installation Manual

Heat Pump Defrost Board Replacement Kit

Series 9350HC, 9353HC, 10353HC, 10354HC and 10355HC

OWNER and INSTALLATION MANUAL

VIGOH55 HEAT PUMP OWNER S!MANUAL! 4438!Muhlhauser!Road!! Suite!600! Hamilton,!OH!45011! 877F278F

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

tcu.z Commercial Programmable Thermostat Installation Instructions

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

Emerson Blue Easy Set 1H/1C

Model Series 5450, 6450, 6450HC, 8450 & 8450HC

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

The Symbiont. GeoThermal

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

For Quick Set-Up go to Page 14

SunBlazer Installation Manual

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING 2 INSTALLATION. Premier Series

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

User s Manual

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

Omega PCB Installation/Operation Dev A - Version 14

AquaCal Installation Manual

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

WSK300 Multifunction Wall Control

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Poolsmart Plus Touchscreen Heating Controller. Installation & Operating Manual

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Installer Guide. WARNING Important Safety Information. 1 Specifications

Instruction Guide: Thermostat Operation

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

HEAT HEAT HEAT COOL COOL

HP50HA ABG Heat Pump

CommStat 4 Controller

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

I/O ZONE 560/583 AND OPERATION MANUAL

PROFESSIONAL - SSE. Stainless steel interior and exterior (with galvanized back and bottom)

Heat Pump Pool & Spa Heater

OWNER S MANUAL Models AT75 & AT110

Comfort System T-21-P Touchscreen Thermostat Installation Manual

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Q&A 2016 Practical Guide

BasicTroubleshooting Information and Guidelines

T-32-TS Touchscreen Thermostat. Installation Manual

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installation, Start-Up, and Operating Instructions

INSTALLATION INSTRUCTIONS & REPLACEMENT PARTS LIST

OWNER S MANUAL Venstar Inc. 08/07

HEAT COOL. Meets Commercial California Title 24

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

Product Manual SZ1009

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

OWNER S MANUAL Venstar Inc. 08/07

Operator: Save these instructions for future use!

Transcription:

INSTALLATION MANUAL G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309

G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309 INTRODUCTION This manual was designed to inform you on the correct way to install the GulfStream Heat Pumps. By following these simple instructions, you will be able to eliminate unnecessary time wasted on job sites. This is not step-by-step installation manual, but a reference guide if you have questions. We have also added ATTENTION, WARNING, and CAUTION boxes to help you identify the most important things to watch out for. Please make sure the warranty card and Homeowner Manual are given to the Homeowner after each installation. These are located inside the heat pump, in the same package with the unions. Attention, Warning, and Caution Boxes have been placed throughout manual to point out important information. Attention: Warning: Caution: Important information to be aware of. Action that might void warranty. Safety issue for owners. For questions about installation please call the Heat Pump Services Department from the job site. 954-318-6900 Electrical requirements can be found on the rating plate located on the bottom front of the base pan of the unit. It is the responsibility of installers to make sure all applicable codes related to the installation of this product are followed. Page 1

G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309 PAGE Introduction 1 Location of Heat Pump 3 Preferred Location Placement Example of Normal Installs Cold Air Recirculation Do s and Don ts of Plumbing the Unit 4 Plumbing Sequence 5 Multiple Heater Install 6 Electrical 7 Low Voltage Wiring 8 Location of Voltage Wires Bonding the Unit 9 Board Operation 10 Board Features to Explain to Home Owner Lock-Out - Lock Access to Board Hidden Service Menu/Set Preferences 11, 12 Select Language Remote T-Stat Solar Control Time Delay Spa Timer Even-Heat Feature for Pool Spa 13 Heat - Cool Unit Operation 14 Diagrams Plumbing Sequence Diagram 5 Multiple Heater Wiring Diagram 15 Pool Wire Diagram 16 Even-Heat Control Diagram 17 Contact Infomation 18 TABLE OF CONTENTS

LOCATION OF HEAT PUMP Location is probably the most important consideration when installing a heat pump. Poor installation can adversely affect performance, as well as cause problems with servicing and overall customer satisfaction. PREFERRED LOCATION PLACEMENT Have as much space as possible between the heater and house or any overhangs. Example shown is a preferred installation but is not always practical. EXAMPLE OF A NORMAL INSTALL See an example of a standard installation, which should work correctly with the space available. Make sure there are no overhangs that would cause the unit to recirculate the cold air. This will make the unit go into defrost mode. COLD AIR RECIRCULATION The heat pump gets its heat from the surrounding air; therefore, recirculation of the cold air off the top of the unit should be avoided. Enclosed spaces such as garages and sheds without proper ventilation should be avoided and may void warranty of the refrigerant components. In order to maintain maximum performance, avoid low overhangs such as porches, overhanging brush, etc., whenever possible. Page 3

DOs & DON Ts OF PLUMBING THE UNIT Consider the direction the heater is facing. The water connections run out the side of the heater. This keeps piping out of the way so customers and service personnel don t step on or trip over the piping. It defeats the purpose to run the piping back around the front of the heater. Try to keep all piping out of the way. Do plumb unit to side. Don t run pipes back around to the front of the unit. This makes access to the panel difficult for service. Don t plumb unit so that service personnel cannot remove or easily access the corner panel. A simple 90 turn can make all the difference for easy access between serviceable and non-serviceable. THE CONTROL PANEL MUST ALWAYS FACE OUT, away from walls and obstructions for ease of customer use and serviceability. Good Example Bad Example Page 4

PLUMBING SEQUENCE It is very important to plumb in the correct order. PLUMBING SEQUENCE The piping sequence is Pool Pump Filter Heater Chlorination System(s) Pool. Rigid PVC piping is recommended and all joints secured with PVC glue. Installation MUST conform to all local codes. Make sure water-flow is correct as indicated on the back of the heater. Again, try to keep piping away from areas that may be tripped over or stepped on when operating heater or servicing. Try to keep elbows and piping to a minimum to avoid excessive pressure drop. We use a full-flow heat exchanger so no external bypass is needed up to 60 GPM (Gallons Per Minute). Swimming Pool Pool To Pump Pump Salt Chlorine Generator To Pool Salt Water Chlorine Generator G&F Manufacturing 7902 Interstate Court N. Fort Myers FL 33917 Phone: 239.567.0009 Fax: 239.567.1907 If incorporating a Solar Pool Heating System to work in tandem with your heat pump, it should be plumbed here - AFTER the heater. * Solar Pool Heating GulfStream Heat Pump To Salt Chlorine Generator Heat Pump Pump To Filter Filter to GulfStream Heat Pump Filter * It is also possible, though not recommended, to plumb the solar heating system before the Heat Pump. It is not ideal as the temp of the solar heated water entering the unit may not produce the optimum desired temp by the homeowner. Please call the Heat Pump Services Department if you have questions about the plumbing order. 954-318-6900 Page 5

MULTIPLE HEATER INSTALL Multiple heater plumbing must be designed with balancing valves and flow meters to assure at least minimum water-flow to each heater. You will want to consult with our service department for important technical data prior to installation. A diagram of the system's flow should be drawn out prior to installation. This will prevent plumbing errors while on site, and help ensure the installation will go quickly. WIRING MULTIPLE HEATERS TO BE CONTROLLED BY ONE MASTER HEATER 1. Install external 2-pole 24-volt contactor. 2. Wire master contactor low voltage tabs to external contactor low voltage tabs. 3. Run low voltage wire from Heater 2 s pools/spa terminal on back of board to external contactor, L1 and T1. 4. Run low voltage wire from Heater 3 s pools/spa terminal on back of board to external contactor, L2 and T2. Pay close attention to different wiring colors to avoid confusing the wires during this set-up. In addition to causing installation delays and aggravation, mismatched or incorrect wiring may also cause problems with heater operation. 5. Program Remote T-Stat setting to ENABLED on Heater 2 and Heater 3. 6. This system is designed so that when master The Master Heater turns on, it energizes the contactor, causing all sub units to run until The Master Heater shuts off. You may also want to program the time delay on Heater 2 to 6 minutes, and Heater 3 to 7 minutes. This prevents the units from kicking on all at once, which may cause a power surge. Connecting another external contactor to low voltage tabs of the external contactor, you may wire an additional heater and all will be controlled by The Master Heater. MULTIPLE HEATER WIRING DIAGRAM LOCATED ON PAGE 16 Page 6

ELECTRICAL A qualified electrician must install the electrical power in accordance with local code requirements. Conduit must be run all the way up to electrical box and installed with appropriate connector. Failure to do so voids warranty of electrical components. Running wires as seen in Picture 1 not only allows snakes, bugs, lizards, etc., into box, which could possibly short components, but also poses a direct short hazard where wires penetrate the control box. Picture 1 - Bad Example Picture 2 - Good Example Bugs or lizards getting into board or shorting out the board will not be covered by warranty. In the bottom of the control box, there is a rubber-piercing plug through which to run low-voltage wiring for external controllers. Simply use a sharp tool, such as a razor, to pierce the plug and run the external control wires through it. Step One Step Two Page 7

LOCATION OF LOW VOLTAGE WIRES On the top right-hand corner of the control board, are the connections for outside controllers. Only Dry Contact (no voltage) Connections are to be made here. You may connect external controllers with a thermostat, without a thermostat, flow-switches, etc., to these connections. caution Not using the designated area to run your wires can cause safety issues and void warranty. To connect a three-wire controller, use common and either High or Spa, depending on switch, to these connections and disregard Pool or Low wires. Pool/Spa Terminal Wiring diagrams can be found on the back pages of this manual. Page 8

BONDING THE UNIT Bonding is often confused with electrical grounding. On the outside of our control box, on the bottom right-hand corner, is a bonding lug. Because all metals have different electrical potentials, all metal and electrical components of the pool system MUST be bonded together. Check all local and state code requirements. Damage caused by incorrect or no bonding will not be covered by warranty. Page 9

BOARD OPERATION Board operation is kept simple. You simply need to use the Mode button to toggle between Pool and Spa and Up and Down Arrows to adjust temperature set points. Do not leave these instructions where the Homeowner can see. If the Homeowner tampers with and/or damages the programming on the board, the warranty will be voided. BOARD FEATURES TO EXPLAIN TO THE HOMEOWER ADJUSTING TEMPERATURE: Use the Mode button to toggle between pool and spa. Use Up and Down Arrows to adjust temperature set points. LOCKING AND UNLOCKING THE CONTROLS: You may also lock settings by simply pressing and holding the Mode button for approximately 20 seconds until Locked displays on the digital readout. Repeat same to unlock controls. These are the only controls the customer needs to know about or use. All other set-ups are done in the hidden menu and should not be relayed to customer. Do not leave these instructions where the Homeowner can see. If the Homeowner tampers with and/or damages the programming on the board, the warranty will be voided. Page 10

HIDDEN SERVICE MENU ALL OPTIONS AND CALIBRATIONS ARE IN THE HIDDEN MENU Only the Hidden Menu items on the previous page, related to Temperature and Lock/Unlock should be shared with the Homeowner. Any of the other following options in the hidden menu are for service technicians ONLY!!! Any Programming Damage caused by non-service technician will not be covered by warranty, and will result in a voided warranty. TO ACCESS THE HIDDEN MENU OPTIONS Press and hold Up and Down Arrows at the same time until Option 1 appears in the display. Release arrow buttons, and use Mode to toggle through options. Use Up and Down Arrows to change settings at each option. OPTION 1: Language Select (Default is English ) Options: English, Spanish, French, Portuguese & German. Press the Up OR Down Arrows to toggle between selections. OPTION 2: Remote T-Stat (Default is Disabled ) This option is used for an external controller with its own thermostat, such as an Aqualink, Aqualogic, Compool, etc. Press the Up OR Down Arrows to display Enabled if using an external thermostatic controller. Page 11

HIDDEN SERVICE MENU Continued Options in the hidden menu are for service technicians ONLY!!! OPTION 5: Solar Control (Default is Disabled ) This option, with additional wiring, will allow the GulfStream Heat Pump to monitor the performance of the pool s solar heating system, and will automatically control the temperature. Temperature set point for the heater can be lower than solar but never higher; the unit will run till the set point for the heater is satisfied. Then it will get heat from the solar. When the solar set point has been reached the water will be diverted from the panels to prevent form going past the set point After accessing the service menu, press Mode until Solar Control displays on the screen. Then, to set the temperature, press Mode again until Pool- Solar Heat displays. Use Up Arrow when Pool Temperature set point comes up, Use Mode button to get the Pool- Solar Heat set point adjust using Up OR Down Arrow. OPTION 6: Time Delay (Default is 5 Minutes ) You may temporarily set the delay to 0 by pushing the Down Arrow. The system will automatically revert back to 5-minute time delay after 10 minutes. OFF will not allow the spa to run. Page 12

HIDDEN SERVICE MENU Continued OPTION 7: Spa Timer (Default is Continuous ) This option is for rental properties or Homeowners who do not want the spa to be left on indefinitely. Options are: Continuous, Off, or Up to 20 hours in 15-Minute Increments. OPTION 9: Temperature Scale (Default is Fahrenheit ) Use Up and Down Arrows to set Fahrenheit or Celsius to show on display screen. Page 13

HIDDEN SERVICE MENU Continued Options in the hidden menu are for service technicians ONLY!!! EVEN-HEAT FEATURE ON POOL/SPA OPTION 8: Even-Heat (Default is Disabled ) When enabled, this feature is activated when Water Pressure Switch, (WPS) is sensed open for more than 1 minute. The WPS being open for more than 1 minute serves as an indication to the control board that the external timer has timed out and pump has been shut off. This feature is meant to periodically turn the pump on based on the Even-Heat Delay setting and circulate the water. Time interval options are: 1 Hour, 2 Hour, 3 Hour, 4 Hour, Default, and Off. The water circulation distributes the heat evenly and control will sample water temperature to find out if there is a need for heating. If there is a need for heating, the heat pump will heat until temperature set point is reached. The pump will then be de-energized and the Even-Heat timer will reset. If there is no call for heat when the pump is turned on, the pump will shut off after a 5-minute time delay and the Even-Heat timer will reset. During Even-Heat time delay if WPS is sensed closed then Even-Heat Feature is canceled. The Even-Heat Delay setting remains per user setting in the set up menu. Even-Heat is activated when WPS is sensed open again for more than 1 minute. In case the water flow switch does not close on the second attempt, control will then display EVEN-HEAT, LOCKOUT and stop outputting. The user will have to reset power to the heat pump to unlock the control. Protection features with regard to the state of WPS, LPS and HPS apply when compressor is running. INSTALLING AN EVEN- HEAT FEATURE To install an Even Heat Feature, wire an extra contactor in parallel with time clock (See Wiring Diagram, Pg. 18). Wire low voltage side of contactor to control board marked Pump (See Wiring Diagram, Pg. 18). Set desired Time Interval that you would like the heater to check the water temperature. See the Even-Heat Feature wiring diagram on Page 18 of this manual. Incorporting the Even-Heat Feature will change the efficiencies of your Heat Pump operation. Page 14

HEAT COOL UNIT OPERATION OPERATION INSTRUCTONS FOR HEAT COOL MODELS ONLY. COOLING FEATURE IS ONLY FOR POOL, NOT FOR SPA. There are 2 Choices of Heat Cool Options Choice One HEAT COOL OPTION 3 IN HIDDEN MENU This will allow your Heat Pump to keep the temperature in your pool at the same temperature, so if your unit gets 2º warmer or colder, the unit will heat or cool the pool until it reaches set point again. 1. Go into service menu by pressing and holding the Up or Down Arrows at the same time, until screen changes to Language Select Default is English. 2. Press the Mode button until screen says -Default is: Pool Heat/Cool. 3. Screen will read Pool-Heat/Cool Disabled - Press Down Arrow to enable it. 4. Wait approximately 20 seconds for screen to display Back to Pool-Heat. 5. Press Mode button; screen will switch to Pool Heat/Cool. 6. Use Up or Down Arrows to adjust pool temperature set point to desired temperature. 7. Press Mode button while still in the Pool Temp set point screen. Choice Two HEAT or COOL OPTION 4 IN HIDDEN MENU This will allow your HP to either Heat or Cool your pool 1. Go into service menu by pressing and holding the Up or Down Arrows at the same time, until the screen changes to Language Select - English. 2. Press the Mode button until screen says -Default is: Pool Heat/Cool. 3. Screen will read Pool-Heat/Cool Disabled - Press Up Arrow to enable it. 4. Wait for screen to go back to Pool-Heat. (After 20 seconds). 5. Press Mode button; screen will switch to Pool Heat/Cool. 6. Set temperature and let it go through the delay. The unit will start cooling the pool until it hits the set point. 7. To switch back to Heat, press the Mode button till it displays Pool-Heat. Page 15

DIAGRAMS Wiring diagrams referenced throughout this manual appear on the following pages. Multiple Heater Wiring Diagram Pool Heater Wiring Diagram Even-Heat Control Diagram HEATER 2 Pool/Spa HEATER 3 Pool/Spa L1 T1 EXTERNAL CONTACTOR L2 T2 24 Volts L1 T1 HEATER 1 Master Heater Pool/Spa MASTER CONTACTOR G&F Manufacturing 7902 Interstate Court N. Fort Myers FL 33917 Phone: 239.567.0009 Fax: 239.567.1907 L2 T2 24 Volts Page 16

DIAGRAMS Black Red Wire - Use for 208 V Application Orange - 230 Volt 240 Volt L1 MAIN CONTACTOR L2 Transformer 24 VAC T1 T2 Blue Yellow Violet Violet Field Wiring for Remote Optional 10K Switch or Solar Sensor Thermostat Brown FAN CAPICTATOR Brown Green COMPRESSOR CAPICTATOR FAN MOTOR S COMPRESSOR R C Black Blue Black White Optional 24 Vac Field Wiring to Even Heat Contactor Red Solar Valve Digital Control Reversing Valve Pump Compressor High Pressure Switch Black Wires Solar Sensor Water Temp Sensor Low Pressure Switch Pink Wires Water Pressure Switch White Wires Pool/Spa T-Stat Defrost Temp Sensor HIGH VOLTAGE FIELD CONNECTION 208-230/1/60 220-240/1/50 G&F Manufacturing 7902 Interstate Court N. Fort Myers FL 33917 Phone: 239.567.0009 Fax: 239.567.1907 Page 17

DIAGRAMS G&F Manufacturing 7902 Interstate Court N. Fort Myers FL 33917 Phone: 239.567.0009 Fax: 239.567.1907 Optional 10K Solar Sensor Field Wiring for Remote Switch or Thermostat Line from Time Clock Even-Heat Contactor Field Installed 24 Vac From Transformer L1 M2 L2 Digital Control Pool/Spa T-Stat Solar Sensor H20 DEF Solar Valve T1 T2 Pump Comp RV HPS LPS WPS Black Wires Pink Wires Load to Time Clock 24 Vac Even Heat Control Wires LEGEND CAUTION: This is a parallel circuit to existing time clock. Proper phasing must be maintained. 24 Vac To Main Contact DEF Defrost Temp Sensor HPS High Pressure Switch H20 Water Temp Sensor LPS Low Pressure Switch M2 Even Heat Contactor RV Reversing Valve WPS Water Pressure Switch Page 18

G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309 Service All service must be handled by An Authorized Service Center Warranty may be void if a non-authorized service representative does service. Do not return the heater to your dealer, as they do not provide service. Before calling for assistance or service, please check the Troubleshooting Section of this manual or call your dealer. This may save you the cost of a service call. If you still need help, follow the instructions below. For Service or Questions Please Contact Us (954) 318-6900 When asking for help or service please provide a detailed description of the problem, your heater s complete serial number, the purchase date and dealer purchased from. This information will help us respond properly to your request. Keep a copy of the sales receipt showing the date of purchase. Proof of purchase will assure you of in-warranty service. Manufactured By G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida 33917 GulfStream, The GulfStream logo, GulfStream Swimming Pool Heat Pumps and GulfStreamHeatPump.com are trademarks of G&F Manufacturing The AHRI Certification and Member logos are trademarks of AHRI.