THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES

Similar documents
FIRST-CLASS IN TRAINS

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Fundamentals of Insulation and their effect on buidling sustainability

KoolthermTM. Technical Data. HVAC & Building Services Pipe Insulation

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Traction Cable Radox 3 GKW

Fire Retardant Resins PERFORMANCE THAT TAKES THE HEAT

TROsiFOl UV+ english

TECHNICAL TEXTILE DIVISION

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Fire Protection Industry

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

DualX X-ray Inspection System


Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Second Issue April See rear cover for applicable countries

Havells Fire Survival Cables

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Modula Standard Performance

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Arma-Chek D THE DURABLE PRE-COVERED ARMAFLEX SYSTEM TO WITHSTAND MECHANICAL STRESS

For more structural safety

For more structural safety

Flame Retardant Polyethylene Tubing

Cable tray solutions. For tunnels GUIDE. The global specialist in electrical and digital building infrastructures

MECHANICAL FIRE STOPPING SOLUTIONS

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

We thank you for allowing us to introduce Hi-Tech electric & Refrigeration co. to you as one of the leading HVAC-R spares supplier.


Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

FIRE TUBE Fire protection for process pipes and structural steel

SCREEN VISION SV 3% KOOLBLACK TM

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Pneumatic Tubing POLYTUBING O.D. 5/32"

A JOURNEY OF COMBINING FIRE SAFETY AND DESIGN CRITERIA FOR ENGINEERING THERMOPLASTICS FOR RAILWAY INTERIORS

Fire protection. DECORATIVE PANELS Fire protection

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

Real-time Monitoring Technology for Preservation Environment of Archives

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

Efficient curing processes with innovative UV-LED technology The Heraeus Noblelight UV-LED portfolio

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

XP-hf. Plural Component Sprayers for the Highest Demand Protective Coating Applications 1 PROVEN QUALITY. LEADING TECHNOLOGY.

OVERVIEW OF THE ELECTRIC RADIATORS RANGE

the Greenest Foodsafe Refrigeration in the World

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

New Recognition Certification for Access Hardware INDUSTRY ARTICLE

PERFORMANCE TESTERS. Performance Textile Testing

EN : A Report To: Poliuretanos S.A. Document Reference: (Issue 2), (Issue 2) & (Issue 4) Date: 13 th February 2015

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ATC Heating Devices. P. 1 ATC Heating Devices

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

ON FIRE OF QUALITY: SINCE 1972 A CONTINUUM

fire resistant cables

SCOPE OF ACCREDITATION

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

ELECTRICAL FIRE STOPPING SOLUTIONS

Creating a safer world!

Single core cables with reduced wall thickness

FIRE TESTING SERVICES FIRE TESTING SER

THE TRUE FIRE SURVIVAL CABLE

CI/SfB. September MediCare range. MediCare Standard. MediCare Plus. MediCare Air

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

BATTERY CASE & COVER

AT, MT & ES Series Super Low Sound Fan

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

Classification of Fire Performance of Wall and Ceiling Lining Materials

(front cover) Tatami Nara, ashlar. (left) Tatami Straw and Rush, monolithic. (back cover) Tatami Zen.

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Dräger PointGard 2100 Detection of toxic gases and vapours

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

GX-20/FM-200 Fire Extinguishing System

Global innovation in fire fighting

Tratos Railway Cables

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

maximise the sun s energy with warmflow solar Warmflow Solar

Annex to the Accreditation Certificate PL according to DIN EN ISO/IEC 17025:2005

Company Presentation

NON-FLAMMABLE WALL COVERING SYSTEM FOR INNOVATIVE FIRE PROTECTION

FRANCE M & F RANKING ACCORDING TO NF F

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

flexible conduit solutions for rail THE POWER IN CABLE MANAGEMENT

A Primer on HFOs. Hydrofluoro-olefins Low-GWP Refrigerants. Brett Van Horn, PhD Arkema Inc.

CONNECTION SYSTEMS TRANSIT APPLICATIONS

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

BS /1000V XLPE Insulation LSZH Sheath Cables

Transcription:

THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES Physically crosslinked polyolefin foam for thermal and acoustic insulation in railway vehicles. Meets the highest Fire and Smoke classification in major International Standards EN 45545-2 (HL3), NFPA 130, BS 6853 and TB/T 3237. PHYSICALLY C R O S S L I N K E D SEKISUI TECHNOLOGY

Enhancing passenger comfort and safety Effective thermal and acoustic insulation maintains a balanced interior environment by protecting passengers from noise and exterior temperature extremes. Thermal insulation of the rail car and HVAC system provides improved energy efficiency thus reducing loads and energy consumption. These key factors highlight the importance of insulation in enhancing passenger comfort and safety whilst at the same time reducing environmental impact. Thermobreak RT and Thermobreak AcoustiPlus are innovative, fibre-free insulation materials specifically designed for the railway and HVAC transportation equipment market. Thermobreak RT and Thermobreak AcoustiPlus are manufactured from physically crosslinked polyolefin foam, invented and commercialised by the Sekisui Chemical group. Today Sekisui Chemical is the largest polyolefin foam manufacturer in the world with multiple manufacturing facilities throughout Europe, USA, Asia and Australia, employing over 23,000 people. All foam manufacturing facilities are ISO 9001 and ISO 14001 accredited. Sekisui Chemical is committed to a corporate policy that recognises the utmost importance of our living environment. Our responsibility to the environment during the development of products and in all of our manufacturing processes is of highest priority. Originally developed in Australia, Thermobreak is widely used by leading railway builders and HVAC equipment manufacturers and has been supplied to numerous railway projects globally for over 20 years. Thermobreak RT is the first closed cell insulation product to achieve HL3 level up to 25mm thickness.

Insulation for Railway Vehicles Technically Superior Thermal Insulation Our unique physically crosslinked technology results in a smaller and more evenly distributed closed cell structure. Cell structure directly affects thermal conductivity and vapour permeability. Both are key factors in short and long-term insulation performance. Coupled with low emissivity reinforced aluminium foil facing, Thermobreak RT offers superior insulation performance and durability compared to any other flexible insulation. > Class leading thermal conductivity > Very lightweight > Flexible, fibre-free and easy to fabricate > Optional adhesive backing for faster application Thermal Conductivity (k) Fire & Smoke Safety Thermobreak RT range offers the highest fire and smoke ratings to meet most major National and International Standards > EN 45545-2 ( HL3 up to 25mm [ 1 ] ) > PRIIA-NFPA 130 > BS 6853 (Cat 1a, 1b) > TB/T 3237 0.030 W/mK @ 10 C 0.032 W/mK @ 23 C 0.208 BTU.in/h.ft 2 @ 50 F 0.221 BTU.in/h.ft 2 @ 73 F Application Areas Major applications include duct insulation, AC insulation and body/wall insulation. Superior thermal performance at lower thicknesses Vapour Permeability 2.3 X 10-15 Kg/ Pa.s.m 0.002 perm-inch Relatively constant k value over a 10 year period Permeability Resistance factor μ > 80,000 Optimum resistance to vapour transmission Density (foam core) 25 Kg/m 3 1.5 lb/ft 2 Low density ensures minimum weight Environmental and Health & Safety Thermobreak RT is manufactured to ISO 14001 environmental Standards and supports environmental initiatives and directives > Compliance to REACH directives > Compliant to RoHS directive > Zero ODP (Montreal Protocol) > Zero PVC, zero formaldehyde > Resistance to mould growth > Low GWP Thermobreak RT Product Range RT Standard product. Reinforced aluminium foil. Meets EN 45545-2 (HL3), NFPA 130, BS 6853 (1b) RT-LSH Enhanced Fire and Smoke properties. Heavy duty facing. Meets BS 6853 (1a) RT Tube Preformed tubes with reinforced aluminium foil. Meets EN 45545-2 (HL3), NFPA 130, BS 6853 (1b) Options Thermobreak is available with a factory applied adhesive backing designed to withstand 100 o C [212 o F]

RT RT-LSH RT TUBE Size Availability Thermobreak RT & RT-LSH Rolls also available for non adhesive backed product. Other sizes available on request Sheets Width 1200 mm 47 ID 5 ~ 250 mm 1/4 ~ 10 Length 2000 mm 78 Wall thickness 5 ~ 50 mm 1/4 ~ 2 Thickness range 3 mm ~ 50 mm 1/8 ~ 2 Length 2000 mm 78 Technical Data Material: Physically crosslinked closed cell polyolefin foam with factory applied reinforced aluminium foil. Optional pressure sensitive, high temperature adhesive backing Density (foam core only): 25kg/m 3 1.5 lb / ft 2 Tubes Thermal Conductivity: 0.032 W/m/ K (@ 23 C 0.208 BTU.in /h.ft2 @ 73 F Water Vapour Permeability (ASTM E96): 2.3 x 10-15 kg/(pa.s.m) 0.002 perm-inch (0.0084 mg.m/n.h) Water Vapour Permeance: 1.95 x 10-4 g/mn.s 0.0034 perm ½ thickness Permeability Resistance Factor: μ > 80,000 Water Absorption by Volume (JIS K6767): <0.1% v/v (0.00038g/cm 2 ) <0.1% v/v Resistance to Fungi (ASTM G21): Ozone Resistance: UV Resistance: Zero Growth Excellent Excellent Operating Temperature: -80 C ~ +100 C -112 F ~ 212 F Fire & Smoke Behaviour Thermobreak RT Test Method Description Result Tested thickness ISO 5658 Part 2 Flame Spread COMPLIES (EN 45545-2 R1, HL3 RATING) ISO 5659 Part 2 Smoke Toxicity COMPLIES (EN 45545-2 R1, HL3 RATING) 5 ~ 25 mm Smoke Density COMPLIES (EN 45545-2 R1, HL3 RATING) [1/4" ~ 1"] ISO 5660 Part 1 Heat Release Rate COMPLIES (EN 45545-2 R1, HL3 RATING) ASTM E162 Surface Flammability COMPLIES (PRIIA/NFPA 130) ASTM E662 Smoke Density COMPLIES (PRIIA/NFPA 130) 12 mm ASTM E1354 Heat Release Rate COMPLIES (PRIIA) [1/2"] BSS 7239 (Boeing) Smoke Toxicity COMPLIES (PRIIA) BS 476 Parts 6 & 7 Class 0 COMPLIES (BS 6853, CLASS Ib RATING) 12 mm BS 6853 Annex B2 Smoke Toxicity COMPLIES (BS 6853, CLASS Ib RATING) [1/2 ] BS 6853 Annex D8.4 Smoke Density COMPLIES (BS 6853, CLASS Ib RATING) GB/T 2406.2 Oxygen Index COMPLIES (TB/T 3237-2010) UIC 564-2-1991 Combustion Resistance COMPLIES (TB/T 3237-2010) 20 mm GB/T 8323.2-2008 Smoke Density COMPLIES (TB/T 3237-2010) [3/4"] TB/T 3237-2010 Part 4.4 Smoke Toxicity COMPLIES (TB/T 3237-2010) Thermobreak RT-LSH Test Description Result Thickness BS 476 Parts 6 & 7 Class 0 COMPLIES (BS 6853, CLASS Ia RATING) 25 mm BS 6853 Annex B2 Smoke Toxicity COMPLIES (BS 6853, CLASS Ia RATING) [1"] BS 6853 Annex D8.4 Smoke Density COMPLIES (BS 6853, CLASS Ia RATING)

New Generation Acoustic Liner The new generation lightweight acoustic material made from physically crosslinked polyolefin foam with partially open cell structure to enhance sound absorption, whilst maintaining the advantages of closed cell structure. It provides both sound and thermal insulation. It provides excellent sound absorption properties whilst offering: > Fibre free insulation > Meets major railway Fire & Smoke Standards - EN 45545-2 (HL3) - NFPA 130 - DIN 5510-2 - BS 476 Class 0 > Lightweight and flexible > Water absorption resistance > Anti-microbial to ASTM G21 > Optional adhesive backing > Easy to fabricate Thermobreak AcoustiPlus is ideal for wall and body insulation, duct insulation, AC insulation, floor insulation, as well as areas where noise absorption is required to enhance passenger comfort. Technical Data Material: Physically (irradiation) crosslinked partially open cell polyolefin foam with factory applied reinforced aluminium foil and optional pressure sensitive adhesive backing Density (foam core only): 25kg/m 3 1.5 lb / ft 2 Thermal Conductivity (ASTM C518): 0.036 W/m/ K @ 23 C 0.249 BTU.in /h.ft2 @ 73 F Resistance to Fungi (ASTM G21): Noise Reduction Coefficient (ISO 354): Zero Growth 0.30 (10 mm thickness) 0.40 (15 mm thickness) 0.40 (24 mm thickness) Operating Temperature Range: -80 C ~ +100 C -112 F ~ 212 F Maximum Recommended Design Air Velocity: 20.3 m/s 4000 fpm Fire & Smoke Behaviour Thermobreak AcoustiPlus Test Method Description Result Tested thickness ISO 5658 Part 2 Flame Spread COMPLIES (EN 45545-2 R1, HL3 RATING) ISO 5659 Part 2 Smoke Toxicity COMPLIES (EN 45545-2 R1, HL3 RATING) 25 mm Smoke Density COMPLIES (EN 45545-2 R1, HL3 RATING) [1"] ISO 5660 Part 1 Heat Release Rate COMPLIES (EN 45545-2 R1, HL3 RATING) ASTM E162 Surface Flammability COMPLIES (PRIIA/NFPA 130) ASTM E662 Smoke Density COMPLIES (PRIIA/NFPA 130) 25 mm ASTM E1354 Heat Release Rate COMPLIES (PRIIA) [1 ] BSS 7239 (Boeing) Smoke Toxicity COMPLIES (PRIIA) BS 476 Parts 6 & 7 Class 0 CLASS 0 25 mm [1"] DIN 54837 Burning Test COMPLIES (DIN 5510:2) Classification S4, SR2, ST2 15 mm [5/8 ] DIN EN ISO 5659-2: 2013 Smoke Toxicity COMPLIES (DIN 5510:2) Classification S4, SR2, ST2 15 mm [5/8 ]

THERMAL & ACOUSTIC INSULATION FOR RAILWAY VEHICLES ASIA PACIFIC REGION Sekisui Foam Australia 1-5 Parraweena Rd, PO Box 2898, Taren Point NSW 2229 Australia Tel: +61 2 9525 9880 Email: info@sekisuifoam.com.au Web: www.sekisuifoam.com.au Thai Sekisui Foam Co. Ltd 700/329 Moo 6, Amata Nakorn Industrial Estate, Tumbol Donhua-loh, Amphur Muang Chonburi 20000 Tel: +66 38 213219~26 Email: info@thaisekisui.co.th Web: www.thaisekisui.co.th EUROPE Sekisui Alveo (GB) Ltd 4 Kensworth Gate, High Street South Dunstable, Bedfordshire, LU6 3HS UK Tel: +44 (0)1582 600 456 Email: info.gb@sekisuialveo.com Web: www.sekisuialveo.com CHINA Sekisui (Shanghai) Int l Trading Co., Ltd. Room 706, Metro Tower, No.30 Tianyaoqiao Road Shanghai, 200030, China Tel: +86-(0)21-6482-0638 Fax: +86-(0)21-6482-0639 NORTH AMERICA Sekisui Voltek 17 Allen Avenue, Coldwater MI 49036 Tel: (800) 544 2254 Fax: (517) 279 8562 Email: prodinfo@sekisuivoltek.com Web: www.sekisuivoltek.com JAPAN Sekisui Material Solutions Co., Ltd. Address: 2-4-4 Nishitemma, Kita-ku, Osaka-shi, Osaka-fu, 530,-8565, Japan Tel: +81 (0)6 6365 4615 Fax: +81 (0)6 6365 4630