Auditing Association of Canada (AAC) Annual Conference North York, AMEC Environment & Infrastructure

Similar documents
COPYRIGHT ULC STANDARDS

Canada s Experiences: Thematic Session on Wood/Solid Fuel Residential Heating

June 7, 2016 PINCHIN LTD 1. Managing Radon in Buildings A Canadian Perspective SEMINAR OUTLINE WHAT IS RADON?

JOINT CODE INTERPRETATION

TECHNICAL SEMINAR CARLETON UNIVERSITY OCT Gerry Landmesser CFAA-NCR President Mircom Group of Companies

CFAA Alberta Technical Seminar 2010

Legislative Review 2017

Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Transforming the Canadian Home

3.1. Substances Not applicable 3.2. Mixtures Name Product identifier % GHS-CAN Classification GHS-US classification

This page is intentionally left blank.

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Plant Issues in an NFPA 652 Dust Hazard Analysis

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

BUILDING CODE INTERPRETATION

GAS SAFETY Information Bulletin

Fire statistics in Canada, Selected Observations from the National Fire Information Database 2005 to 2014

NFPA Talking Points on NFPA 1 Fire Code update to the 2015 Edition:

Container Recycling Institute

TICKET INFORMATION UTILIZATION BYLAW

Paper Tape Safety Data Sheet*

Study confirms cooking, smoking are top causes of house fires

DISTRICT/ MUNICIPALITY OF Wood Burning Appliance Bylaw No., 20

Building Standards Advisory Promoting construction of safe, healthy, habitable buildings

Fire Sprinklers Working Group Final Report

Understanding and Managing Fire Safety in Housing Accommodation

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

SOUTH CAROLINA LIQUEFIED PETROLEUM GAS PROGRAM (LP-GAS)

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Emergency Telephone Number Emergency Number : CHEMTREC / CANUTEC

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017

BOMA Calgary Luncheon Thursday, October 11, 2012 Building Owners Responsibilities for Fire Safety Equipment (Fire Alarm) Canadian Fire Alarm

New Developments in Green Building. HRM Environment & Sustainability Standing Committee Halifax, NS March 1, 2012

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

2010 FIRE CODE OF NEW YORK STATE

Fire Prevention Coffee Break Training November 2014

4/18/2017. *2012 edition of NFPA 99 has gone through a major overhaul. *This document is now a Code.

FIRE PREVENTION AND PROTECTION*

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

CITY OF PRINCE GEORGE BYLAW NO. 8266, 2010

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

BYLAW 5542 *******************************************************************************

Model Policy On Portable Fire Extinguishers (Ontario Version)

Horticulture Action Plan

Orange County EMERGENCY POWER PLAN (EPP) CRITERIA FOR ASSISTED LIVING FACILITIES & NURSING HOMES

FIRE PREVENTION CODE

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

S 2758 S T A T E O F R H O D E I S L A N D

CSA B Code Installation Code for Oil-Burning Equipment Yukon Housing Contractor s Breakfast March 2014 Presented by Ron Bramadat, Ken Alaric &

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

LexisNexis (TM) New Jersey Annotated Statutes

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

EVAP Project BACKGROUND EVAP UNIT

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

DOUGLAS L. BARRY FIRE CHIEF

Signal Word (GHS-US) 05/06/2015 EN (English US) 1/11

Emergency Telephone Number Emergency Number : /29/2015 EN (English US) 1/12

THE TOWN OF MIDLAND BY-LAW A By-law to regulate open air burning in the Town of Midland and to repeal By-laws and

ASVA Fire Bylaw Guide

Colorado Division of Fire Prevention & Control, Fire & Life Safety Section

Amend Base Code. Amend Base Code. Amend Base Code. Disposition. (Statute, Rule, FBC, Industry) Y/N

CANADIAN DAM ASSOCIATION ASSOCIATION CANADIENNE DES BARRAGES

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Town of Whitby By-law #

Winnipeg Fire Department Fire Prevention Branch

Self-Help Advice. Winter Power Failures

07/18/2016 EN (English US) 1/8

THE CITY OF VAUGHAN BY-LAW BY-LAW NUMBER

Granular Bentonite 8/40

Other Hazards Exposure may aggravate pre-existing eye, skin, or respiratory conditions. Unknown Acute Toxicity (GHS-US) Not available

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

07/18/2016 EN (English US) 1/8

Plant Processing and Extraction Facilities

CFAA Alberta Technical Seminar October 24, 2013 Calgary

Vancouver Airport Fuel Delivery Project. Fire Prevention, Preparedness and Emergency Response

Self-Help Advice. Winter Power Failures

The Corporation of the District of North Cowichan Fire Protection Bylaw Bylaw 3340

H318 Causes serious eye damage.

LOP-3600 Safety Data Sheet

NFPA 45 NFPA 211 NFPA 1600

07/18/2016 EN (English US) 1/8

PART 2. Basic Code Requirements - Semiconductor & Microelectronic Facilities using HPM s

Fire and Emergency Services Newfoundland and Labrador. Public Hearings Proposed Lower Churchill Hydroelectric Generation Project March 2011

Public Input No. 1-NFPA [ Global Input ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Fire Safety Plan Information. For Construction and Demolition Sites

RECOMMENDED READING GUIDE FOR REFRIGERATION PLANT EXAMINATION CANDIDATES

OPERATIONAL GUIDELINE. Office of the Fire Commissioner O.G.# Revision #1 TITLE: ISSUING ORDERS Page 1 of 8

Permitting and Licensing for Hazardous Material Use and Storage

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

Partnerships Across Borders: Parks Canada, NatureServe Canada and NatureServe

For use only under strictly controlled conditions and only by qualified personnel who are fully trained in the handling and use of this product.

FIRE SAFETY POLICY. 2.0 Under national, provincial and municipal fire regulations, the Board will ensure compliance with:

Agency for Health Care Administration

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Transcription:

Auditing Association of Canada (AAC) Annual Conference North York, 2013 AMEC Environment & Infrastructure The Role of the Fire Code in Compliance Auditing Peter Beukema, P. Eng., EP(CEA), EP(EMSLA) Senior Environmental Engineer April 9, 2013

Agenda: Applicability Adoption & Enforcement Audit Criteria Personal Experience Common Audit Findings Things to Consider 2

Applicability Fire Code Compliance Reporting Options: Environmental Compliance Audits (In Scope since at least 1999?) Health & Safety Compliance Audits (directly noted in NFC 2010) Due Diligence Assessments (Phase 1 ESA s with a twist or EMS driven) Storage Tank Management (Proposed financing / Bank Initiated / Internal First Party Audit) Building Condition Assessment (BCA s) $$ 3

Applicability Indirect Fire Code Reference - Example: Environmental Emergencies (E2) Applies to any person that has the charge, management or control of a listed substance, at any time of the year, that is stored either: At or above the threshold quantity specified in Column 3 of Schedule 1; Or, In a container having a maximum capacity equal to or more than the threshold quantity Detailing Prevention, Preparedness, Response and Recovery Measures 76 Flammable Substances and 98 Other Hazardous Substances Declarations are required by EC Testing the E2 Plan at least once per year is required, 4

Applicability Direct Fire Code Reference - Example: Petroleum Tank Management Association of Alberta PTMAA is delegated by the Province of Alberta with the authority to register petroleum storage tank systems regulated under Part 4 of the Alberta Fire Code. The PTMAA is also delegated the authority to certify individuals to install, remove, repair and test storage tank systems. Services provided by the PTMAA include: All matters related to the registration of petroleum storage tanks. Approval of individuals who install, test, maintain, alter, upgrade or remove petroleum tank storage systems. Ensuring that storage tank systems are designed, installed, upgraded, or operated in accordance with the Alberta Fire Code. Compliance monitoring of new storage tank installations. In-service inspection of existing storage tank installations. Monitoring of storage tank closures. 5

Adoption & Enforcement Adoption and enforcement of the National Fire Codes are the responsibility of the provincial and territorial authorities having jurisdiction. The following Provinces and Territories adopt or adapt the National Fire Code: New Brunswick, Nova Scotia, Manitoba and Saskatchewan: Province-wide adoption with some modifications and additions. Newfoundland and Labrador: Province-wide adoption except aspects pertaining to means of egress and to one- and twofamily dwellings. Northwest Territories, Nunavut and Yukon: Territory-wide adoption with some modifications and additions. 6

Adoption & Enforcement The following provinces publish their own codes based on the National Fire Code: Alberta and British Columbia Province-wide fire codes that are substantially the same as National Fire Code with variations that are primarily additions. Ontario Province-wide fire code based on the National Fire Code, but with significant variations in content and scope. Quebec Province - Major municipalities adopt the National Fire Code. Prince Edward Island Province-wide fire code not based on the National Fire Code. Major municipalities adopt the National Building Code. 7

Adoption & Enforcement WHO ARE THE REGULATORS? SOME EXAMPLES: Technical Standards and Safety Association (Ontario) Office of the Fire Marshal (Ontario / Quebec / Nova Scotia) Local Fire Department Representatives Fire Commissioner (BC/MB) Fire Discipline of Safety Services (Alberta) 8

Audit Criteria NFC 2005 NFC 2010 9

Audit Criteria WHAT ARE THE REQUIREMENTS? The 2005 edition of the National Fire Code of Canada (NFC) contained over 300 new technical changes setting out the technical provisions including regulating: Activities related to the construction, use or demolition of buildings and facilities Three Divisions: Division A includes the compliance options, the objectives and the functional statements. Division B contains the provisions now referred to as "acceptable solutions" relating to such issues as building and occupant fire safety, indoor and outdoor storage, flammable and combustible liquids, hazardous processes and operations, fire protection equipment, and fire emergency systems in high buildings. Division C contains administrative provisions. 10

Audit Criteria WHAT ARE THE REQUIREMENTS? The 2010 National Fire Code of Canada (NFC) provides minimum fire safety requirements for buildings, structures and areas where hazardous materials are used, and addresses fire protection and fire prevention in the ongoing operation of buildings and facilities. The 2010 NFC is in an objective-based code format in which all requirements are linked to one or more of the following objectives: Safety Health Fire and Structural Protection of Buildings 11

Audit Criteria Ontario Fire Code, 2007 DIVISION B PART 1 GENERAL PART 2 FIRE SAFETY PART 3 FIRE SAFETY FOR INDUSTRIAL AND COMMERCIAL USES PART 4 FLAMMABLE AND COMBUSTIBLE LIQUIDS PART 5 HAZARDOUS MATERIALS, PROCESSES AND OPERATIONS PART 6 FIRE PROTECTION EQUIPMENT PART 7 INSPECTION, TESTING AND MAINTENANCE OF FIRE EMERGENCY SYSTEMS IN HIGH BUILDINGS PART 8 DEMOLITION PART 9 RETROFIT National Fire Code, 2010 DIVISION B PART 1 GENERAL PART 2 BUILDING AND OCCUPANT SAFETY PART 3 INDOOR AND OUTDOOR STORAGE PART 4 FLAMMABLE AND COMBUSTIBLE LIQUIDS PART 5 HAZARDOUS PROCESSES AND OPERATIONS PART 6 FIRE PROTECTION EQUIPMENT PART 7 FIRE EMERGENCY SYSTEMS IN HIGH BUILDINGS 12

Audit Criteria National Fire Code of Canada, 2010 Part 4 Flammable and Combustible Liquids Section 4.1 General 4.1.1 Scope 4.1.1.1 Application 1) Except as provided in Sentences (2) and (3), this Part provides for the storage, handling, use and processing of flammable liquids and combustible liquids in buildings, structures and open areas. 2) Areas in process plants.. 3) This Part shall not apply to b) Appliances and their ancillary equipment within the scope of CSA B139, Installation Code for Oil Burning Equipment 13

Audit Criteria Ontario Fire Code, 2007 Part 4 Flammable Liquids and Combustible Liquids Section 4.1 Application 4.1.1 Scope and Application 4.1.1.2 Application 2) Except as specifically provided elsewhere in this Part, this Part does not apply to: b) The storage, handling, transportation and use of flammable liquids or combustible liquids to which the Technical Standards and Safety Act, 2000 and its regulations apply, Note that TSSA is the authority having jurisdiction for: Installation Code for Oil Burning Equipment Liquid Fuels Handling Code, 2007. 14

Audit Criteria CSA B139 Installation Code Scope: 1.1 This Code applies to the installation of appliances, equipment, components, and accessories where oil is used for fuel purposes in applications that include (a) space heating; (b) service water heating; (c) power generation; and (d) process application. 1.3 (h) above-ground storage tanks that have a maximum individual capacity of 2500 L (550 gal) and a maximum aggregate capacity of 5000 L (1100 gal). Oil = Fuel oil (oil) diesel, used oil, kerosene, and hydrocarbon fuel oil. 15

Personal Experience COMPLIANCE AUDIT RESULTS (2010): No. of ECA s completed = 38 No. of Days on-site = 53 No. of Days per ECA = 1.4 Number of Non-Compliance Findings = 615 Number of NC s per ECA = 16.2 Least No. of NC s = 5 Most No. of NC s = 46 16

Personal Experience Typical Compliance Audit Areas of Concern: 1. Emissions to Atmosphere (Air & Noise) 2. Water Management 3. Hazardous Materials Management (LBP/PCBs/ACMs/MSDSs) 4. Spills and Emergency Response 5. Storage Tank Management 6. Transportation of Dangerous Goods 7. Waste Management (Hazardous and Non-Hazardous) 8. Fire Code OTHERS INCLUDE: Boiler & Pressure Vessel Management, Sewer Use, Site Remediation, Specialty Chemicals, OH&S, Pesticides, etc. 17

Personal Experience 160 140 120 Number of NC s (2010 Audits) 100 80 NC's BMP's 60 40 20 0 Air Water HMM Spills Tanks TDG Waste Fire Code Typical ECA Areas of Concern 18

Common Audit Fidnings Common National Fire Code Findings: Improper storage of flammable and combustible liquids (4.1.8.1, 4.2.7.2, 4.2.7.9, 4.2.10.1) Improper use of yellow flammable and combustible liquid cabinets (4.2.7.10, 4.2.10.6) Lack of absorbent materials (4.2.7.11) Fire Safety Plan not reviewed every 12 months (2.8.2.1(2)) Gas cylinders not properly stored (doorways, under stairs, unsecured) (3.1.2.4) Fire extinguishers (monthly / annual inspections, mounting, securing) (6.2.1.1, NFPA 10) Numerous Storage Tank System related issues (vents, coating, containment, labelling, protection, etc.) (4.2.3.2, 4.3.1.5, 4.3.13.5) 19

Common Audit Fidnings Specific Ontario Fire Code Findings: Lack of Spills Training every six months (4.1.6.4(2)(h)) Fire Safety Plan not approved: 2.8.2.1(2) The fire safety plan shall be prepared, approved and implemented in buildings regulated by Article 2.8.1.1. approved means approved by the Chief Fire Official. buildings means any structure used or intended for supporting or sheltering any use or occupancy. occupancy means the use or intended use of the building or part thereof for the shelter or support of persons, animals or property. 20

Common Audit Findings Common Installation Code (CSA-B139) Findings: Spacing between wall and tank shell (6.4.2) Secondary containment inspection (6.8.6.1) Inadequate spill containment (6.4.7.1, 6.8.5.7) Proximity to floor drains (6.8.4.2) Vent pipe at least 150 mm above fill pipe (6.13.1.7) Storage Tank size (6.8.4.2) Fill pipe too close to Building Openings (6.12.6) Vent pipe not higher than 4.15m above tank bottom (6.13.1.8) 21

Things to Consider Grandfathering Provisions do exist in Ontario regarding the Installation Code for Oil Burning Equipment in Section 1(3) of Ontario Regulation 213/01 Fuel Oil: (3) Unless otherwise specified in this Regulation or the code adoption document, equipment installed in accordance with the predecessor of this Regulation shall be deemed approved under this Regulation on the day this Regulation comes into force if the equipment complied with the predecessor regulation at the time that it was installed. In Ontario TSSA still applies CSA-B139-06...not CSA-B139-09 Major Quebec Municipalities have not yet adopted NFC, 2010. Know where to draw the line between environmental or health & safety compliance AND engineering requirements. Have access to Technical Experts experienced with the Building Code. May need to rely on Oil Burning Technicians (OBT s) or licensed Petroleum Engineers approved by the Authority having Jurisdiction for any engineering assessment. 22

Things to Consider Acronym Overlap (and Overload) now affecting the Environmental Industry: ECA = Environmental Compliance Approval (new) MOE (Ontario) program for Modernization of Approvals ECA = ECA = ECA = Environmental Compliance Assessment O. Reg. 419/05 when considering air standards Environmental Compliance Audit CSA Z773-03 Operational comparison to Applicable Environmental Legislation Emission Concern Areas (Marine Industry) 23

Contact for additional information Peter Beukema, P. Eng., EP(CEA), EP(EMSLA) Senior Environmental Engineer peter.beukema@amec.com 905-687-6616 FINE PRINT: This presentation is not intended to provide exhaustive coverage of federal and provincial law, regulations, and policy, but rather a general overview of current issues and some coverage of current commentary on some of these issues. Before making corporate or organizational decisions a thorough review of the applicable legislation is strongly recommended.