Zehnder inside: A perfect indoor climate for all requirements

Similar documents
Ventilation Unit Zehnder ComfoAir 350

Zehnder ComfoAir 550. Ventilation unit

Always the best climate for RELIABLE SOLUTIONS. with Zehnder s overall system for comfortable indoor ventilation

Healthy, comfortable and energy-efficient ventilation

Overview and Specifications

Healthy, comfortable and energy-efficient ventilation

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Zehnder Comfosystems. ComfoAir 180 Datasheet

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

Think System Solution to get it right first time

Ventilation & Heat Recovery. The whole house system from OMNIE

HeATING. VENTILATION. COOLING. in ONE SYSTEM.

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

Zehnder Comfosystems Heat and Energy Recovery Ventilation

Zehnder ComfoAir flat 150

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

Put the V back in HVAC

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

Energy Options for Residential Heating. Juergen Korn, P.Eng.

PERFORMANCE. The new generation of MVHR units - ComfoAir Q. Always the best climate for

Whole Home Heat Recovery Ventilation

Heat Recovery Ventilation: Fresh Healthy Indoor Air with all the Savings

PRODUCT DATA SHEETS HEAT PUMPS

Building Regulations 2010: What it means to you.

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

Always the best climate for the IDEAL INSTALLATION

Lossnay RVX Fresh Series Air Ventilation

Ventilation unit Zehnder ComfoAir 200

Ventilation systems. Indoor air quality for inner well-being

ComfoAir Q. Mechanical Ventilation and Heat Recovery

Central Heating and Ventilation

with minimal heat loss for a pleasant and healthy living environment

Systems engineering Slide 1

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

THE PHOTON-HEATING. innovations to save our planet. Grüne Umwelt Technologien GmbH

HUMIDITY-SENSITIVE SOLAR VENTILATION. The sun gives you a breath of fresh air

SINGLE-ROOM VENTILATION. for schools and public spaces

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Heat Pump Water Heater Commercial Leaflet 2012

MECHANICAL VENTILATION

Energy Recovery, Wholehouse Ventilation ECO LIVING

Heat Recovery Units. Heat Recovery 1

Decentralised Ventilation Systems

Ventilation. Product Information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Dee Fly Cube 300 and 370. Heat Recovery ventilation

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Advance, decentralised ventilation with heat recovery

Renewable energies. Ready-made OEM systems for manufacturers of Solar thermal systems Solid fuel boilers (pellets, split logs, wood chips ) Heat pumps

HRV Brochure. Heat Recovery Ventilation

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

Ventilation system Zehnder ComfoAir Q Installer manual. Cooling Fresh Air Clean Air

DUCTING FOR HRV SYSTEMS The distribution of airflows

HCV 4 - HCV 5 - HCH 5 - HCH 8

BEST PRACTICE RECOMMENDATIONS

THE EFFECT OF ENTHALPY RECOVERY VENTILATION ON THE RESIDENTIAL INDOOR CLIMATE

experts in damp, mould, condensation control + organic heating & cooling xchangeair.com.au

Industrial Evaporative Cooling Units

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

better ventilation Maximum effect minimum dimensions

Nothing lost plenty of healthy fresh air gained

CWL Data sheet. Comfort home ventilation system

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

GreenMaster HP Exhaust air heat pump for residential properties

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

QUALITY CONTROL Passive House Checklist

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Heating and cooling ceiling systems Zehnder ZIP Planning document. Heating Cooling Fresh Air Clean Air

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Ventilation system Zehnder ComfoAir Q User manual. Cooling Fresh Air Clean Air

Riverdale NetZero Project Summary of Costs and Expected Performance

Air magic NTD500 Neutral Temperature Dehumidifier Air magic HRV500 Heat Recovery Ventilation. designed for radiant cooling systems.

MECHANICAL SERVICES 101. Ian White

VENTILATION WITH HEAT RECOVERY

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Maincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Zero Energy Home. Team 4 Nittany Designs Edesign100 Section 15 Submitted to: Professor Wallace Catanach 2/22/13 Team Members

Improving your home comfort by enhancing the air

Appendix A. Glossary of Common Terms

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

DEMAND-CONTROLLED HOME VENTILATION

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Installation instruction

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

CLEANAIRE. The energy efficient way to achieve a dry, healthy home. Product Information

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

Decentralised ventilation systems Trust the original.

Transcription:

Zehnder inside: A perfect indoor climate for all requirements Zehnder systems for radiant heating and cooling Zehnder designer radiators Zehnder Clean Air Solutions 1 Zehnder Systems for comfortable indoor ventilation

Tere Zehnder ventilation seminar Tallinn, October 5th 2010 08.10.2010 2

Who we are Anneli Saal, Zehnder Estonia Meelis Saal, Zehnder Estonia Klaus Niederer, Zehnder Engineer for Ventilation, Heating, Air Conditioning Technical Sales Support Export 08.10.2010 3

Agenda The mission statement Our history and the history of the ventilation technology Why ventilation? Advantages of HRV Energy savings Systems comparison Coffee break The four product groups Our products Renovation concepts Life samples Questions and answers 08.10.2010 4

Our mission We want to be the most attractive provider of energy-efficient, healthy and comfortable indoor climate solutions. Comfort Indoor Climate Solutions Health Energy efficiency 08.10.2010 5

The three elements of the triangle Comfort Increasing demand for comfort and a comfortable indoor climate Customers require simplicity and style We spend 70% of our time within 4 walls 08.10.2010 6

The three elements of the triangle Health Increasing sensitivity with respect to a healthy indoor climate (humidity, mould, fine dust, pollen, noise) Increasing proportion of elderly people with even higher demands for a healthy indoor climate Growing awareness regarding a healthy indoor climate for children 08.10.2010 7

The three elements of the triangle Energy efficiency Ecological awareness Limitation of oil and gas Governmental regulations in - Europe with the Energy Performance of Buildings Directive (EPBD) - Other important markets such as US and CN 08.10.2010 8

Indoor climate heating fresh air Functionality Design Efficiency clean air cooling 08.10.2010 9

The Zehnder is family owned since 1895 1895 Manufacturing of motor cycles 1930 First radiators made of steel fresh air 1958 Start of production of Ceiling Panels 1980 Invention and production of the first towel radiator 2000 Entry in residential ventilation with heat recovery 08.10.2010 10

The Zehnder ventilation history 1993 New concept of ventilation in Minergie houses in Switzerland Invention of a cleanable air distribution system 2000 Acquisition of J.E. StorkAir (NL) fresh air 2007 New air distribution system OnFloor Currently Zehnder is the market leader in residential ventilation 08.10.2010 11

Zehnder Comfosystems 08.10.2010 12

The history of ventilation 08.10.2010 13

Why ventilation? We (human beings) can last 3 weeks without food 3 days without water 3 minutes without air We breathe more than 500.000.000 times in our life We spend about 70% of our life inside of 4 walls Is any food more important than air? Where is having healthy air more important than inside? 08.10.2010 14

The tasks of a ventilation system Guarantee of a healthy air quality Limitation of the air humidity Minimising of the ventilation losses 08.10.2010 15

The advantages of a ventilation system with heat recovery Sound removal of pollutants as odors, smoke, housing poisons etc. Avoidance of humidity problems and protection of the building structure Protection of the inhabitants with regard to mould Filtration of the outside air as protection against pollen (allergies) Recovery of the ventilation heat resultant in energy savings No draughts in comparison to the window ventilation or supply valves Safety whilst inhabitants are absent Reduction of the street noise disturbance 08.10.2010 16

Why ventilation People Building Environment High comfort Preservation of health Prevention of damages to building Energy savings Extraction of CO2 and pollutants Extraction of humidity Dense building envelope Residential ventilation with heat recovery 08.10.2010 17

Humidity in buildings 08.10.2010 18

My personal experience 08.10.2010 19

My personal experience 08.10.2010 20

Legal requirements (EnEV 6) Impermeability, minimum change in air ventilation (1) Buildings have to be constructed /designed that the area transferring the heat, including all joints, is made permanently airtight to a standard that meets industry requirements. (2) Buildings have to be constructed / designed that the minimum change in air ventilation necessary for health and heating purposes is guaranteed. 08.10.2010 21

Legal opinion DIN E 1946-6 Planners and builders who build a new residence or renovate an existing one without using a controlled ventilation system are exposing themselves to the risk of liability. Although it cannot yet be stated with any degree of certainty that having a ventilation system is a mandatory requirement, the alternative of relying on the residents to provide the air convection described above by opening windows is extremely risky from a legal point of view. 08.10.2010 22

Various air sectors Living room Kitchen Bed room Hall Bath room Supply air Overflow area Exhaust air 08.10.2010 23

System components Ventilation device Air distribution system Air intakes and outlets Geothormal heat exchangers 08.10.2010 24

Zehnder ventilation devices components DC motors Lowest energy consumption Heat recovery unit High heat recovery > 90% Filters G3, G4, F8, pollen filter Control unit /display 08.10.2010 25

Zehnder heat exchanger 08.10.2010 26

Passivhaus certificate ComfoAir 350 08.10.2010 27

Passivhaus certificate criterias 1. Control criteria At an outside temperature of -10 ºC the supply temperature has to be +16.5 ºC as a minimum 2. Efficiency criteria (heat) The effective heat recovery figure in between -10 ºC to +15 ºC and dry exhaust air of + 21 ºC has to be as minimum 75 % Zehnder ComfoAir 350: 84% 3. Efficiency criteria (electricity) Maximum 0.45 Watts per m³ and hour Zehnder ComfoAir 350: 0.29 W /m³ /h 4. Tightness and Insulation Maximum internal and external leakage 3 % Zehnder ComfoAir: < 1% 08.10.2010 28

Passivhaus certificate criterias 5. Control criteria The ventilation device has to be controlled 6. Sound level criteria Maximum allowable sound absorption in minor rooms 35 db (A) Maximum allowable sound absorption in living rooms 25 db (A) 7. Hygiene criteria The ventilation device has to guarantee perfect hygiene supply air 8. Frost protection criteria The ventilation device has to be protected against icing 08.10.2010 29

ComfoAir 350 electrical consumption Air volume: 200 m³ /h External pressure: 225 Pa Electrical consumption of the unit: 0.29 W /m³ /h x 200 m³ /h = 58 W 58 W x 24 h /d x 365 d= 508 kwh per year Yearly electrical consumption in EEK: 508 kwh x 1 EEK /kwh= 508 EEK 80 EUR 08.10.2010 30

Energy comparison HRV and supply valves 08.10.2010 31

Comparison HRV and supply valves Energy savings in total per year: 7496 kwh Yearly net savings: Ventilation energy savings: 7496 kwh 7496 EEK 479 EUR - Electrical consumption HRV 1670 kwh 1670 EEK 107 EUR Total 5826 kwh 5826 EEK 372 EUR 08.10.2010 32

The differences of the two ventilation systems Topic Supply valves HRV Removal of pollutants NO YES Avoidance of humidity problems NO YES Protection of the building structure NO YES Filtration of the outside air OPTION YES Recovery of ventilation heat NO YES Draughts YES NO Safety whilst being absent Partly YES Reduction of the street noise NO YES 08.10.2010 33

Zehnder ventilation devices 100 150 m³ /h ComfoAir 100 Decentralised ComfoAir 140 Centralised ComfoAir 150 Centralised 08.10.2010 34

Zehnder ventilation devices 150 200 m³ /h ComfoAir 150 flat Centralised ComfoAir 200 Centralised 08.10.2010 35

Zehnder ventilation devices 350 550 m³ /h ComfoAir 350 Centralised ComfoAir 550 Centralised 08.10.2010 36

Heat exchanger and summer /winter bypass Heat exchangers Cross current flow Summer /winter bypass Automatically controlled Temperature freely adjustable 08.10.2010 37

Enthalpy heat exchanger Hygienic humidity recovery without transfer of smells and microbes Retrofittable Recovery figures Sensible: 86% Latent: 63 % Total: 127 % 08.10.2010 38

Cooling unit Artic 350 /550 Increase of the comfort level All in one Evaporator, compressor, condenser, expansion valve Controls Via ventilation device Cooling output 2.2 kw 08.10.2010 39

Zehnder comfobox 5 All in one energy centre Heating, cooling, ventilation and warm water Heat pump sizes 5, 6, 8, 10, 13 kw Ground source Geothermal probe, collector or basket 08.10.2010 40

Zehnder comfobox 5 Advantages All in one whole house energy centre Effective usage of renewable energy sources Minimum space requirements Free cooling and pre-heating with renewable energy Enthalpy exchanger usable High reliability Simple planning and installation of the entire system Settings and commissioning can be done easily 08.10.2010 41

Zehnder comfobox 5 08.10.2010 42

Zehnder comfobox 5 COP values COP 9 8 7 6 5 4 3 2 1-5 C 0 C 5 C 10 C 15 C Temp. of heat source Ground source 5 C /heating system 30 C 6.4 Ground source 5 C /heating system 40 C 4.5 Ground source 5 C /heating system 50 C 3.4 COP real T heating system 30 C T heating system 40 C T heating system 50 C 08.10.2010 43

Zehnder comfobox 5 components Electronic Air pre-heater Storage Ventilation device Hydraulics Heat pump 08.10.2010 44

Zehnder air distribution systems 08.10.2010 45

Zehnder air distribution systems OnFloor 08.10.2010 46

Zehnder air distribution system InFloor 08.10.2010 47

Zehnder air distribution systems Advantages Cleanable Low pressure losses Few components Easy to calculate and design Simple installation High flexibility during installation Damping of the noise level Settings and commissioning can be done easily 08.10.2010 48

Zehnder OnFloor air distribution system 08.10.2010 49

Zehnder OnFloor pipe Comfotube flat 51 Oval and flexible pipe (51 x 138 mm) High quality food-grade plastic (HDPE) Centrally adjustable air volumes Low loss of pressure Easy to clean For installation in the dampening layer Low weight Corrosion-proof 08.10.2010 50

Zehnder OnFloor components Flat 51 straight connector Flat 51 rectangular housing Flat 51 comfoset Flat 51 /4 manifold Flat 51 /6 manifold Flat 51 circular housing 08.10.2010 51

Zehnder InFloor pipe Comfotube 75 /90 Circular and flexible pipe High quality food-grade plastic (HDPE) Centrally adjustable air volumes Low loss of pressure Easy to clean High leak-proofness Low weight Corrosion-proof 08.10.2010 52

Zehnder InFloor components ComfoTube straight connector Manifold boxes ComfoTube housing CLD Manifolds ComfoTube housing TVA ComfoDuct 08.10.2010 53

Zehnder designer grilles 08.10.2010 54

Zehnder designer grilles Engelberg Luzern Abacus Vienna 08.10.2010 55

Zehnder designer grilles Roma Torino Pisa Venezia 08.10.2010 56

Zehnder designer grilles Genua Torino Venezia 08.10.2010 57

Zehnder valves /vents Supply valve STH Extract valve STB Supply valve KE Extract valve STC 08.10.2010 58

Zehnder renovation example 08.10.2010 59

Zehnder renovation example 08.10.2010 60

Zehnder geothermal heat exchangers Advantages Comfort Continuous supply of fresh air Provision of pre heated fresh supply air in winter and pre cooled fresh supply air in summer Health Improved air quality by removing stale and moist air (containing allergens and dust mites) Filtering supply air Energy efficiency Usage of free ambient heat /cool with minimal consumption of electricity 08.10.2010 61

Zehnder earth-brine heat exchanger ComfoFond-L 300 ComfoFond-L 600 08.10.2010 62

Zehnder earth-brine heat exchanger Supply air to the unit External brine filled ground loop PE 20 (300 m³ /h) PE 25 (600 m3 /h) Supply air from outside Connection of the external brine loop 08.10.2010 63

Zehnder earth-air heat exchanger Inlet tower 250 /500 Air geothermal heat exchanger CF 250 /500 08.10.2010 64

Zehnder earth-air heat exchanger Inlet tower 250 /500 External wall grill About 15 m About 1.7 m Wall duct and collection manifold with condensation drainage ComfoTube 110 2-3% gradient 08.10.2010 65

Zehnder project examples 08.10.2010 66

Zehnder project examples 08.10.2010 67

Zehnder project examples OnFloor 08.10.2010 68

Zehnder project examples OnFloor 08.10.2010 69

Zehnder project examples OnFloor 08.10.2010 70

Zehnder project examples OnFloor 08.10.2010 71

Zehnder project examples InFloor 08.10.2010 72

Zehnder project examples InFloor 08.10.2010 73

Zehnder project examples InFloor 08.10.2010 74

Zehnder project examples InFloor 08.10.2010 75

Zehnder project example 08.10.2010 76

Zehnder commissioning 08.10.2010 77

Zehnder services and support Zehnder provides Consultation and training Design assistance and support Supply Onsite support for installers Commissioning support Post installation support 08.10.2010 78

Questions??????????

Many thanks for your attention