EH0554 Indoor Climate Control

Similar documents
EH0533 Indoor Climate Control

EH kW Panel Heater

EH Fin Oil-Filled Radiator with timer

EH1688. Over Door Heater & Fan Chauffage de Porte & Ventilateur

EH W 7-Fin Oil-Filled Radiator Adjustable thermostat Built-in carrying handle Safety overload cut-out 2 year guarantee

EH " (40cm) Remote Control Wall Fan

EH kW 11-Fin Oil-Filled Radiator

EH1210. airooncentre.co.uk. Peltier Dehumidifier Déshumidificateur Peltier. The Award Winning Ventilation Specialists

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

EH W Pressure Washer

EH1415 Bébé Mayor Ultrasonic Humidifier with 2.5 L Water Tank

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Local air conditioner

Heat Pump / Air Conditioner

ARTICA. 8000Btu. Room Air Conditioners Portable Range

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

GDDEM10 DEHUMIDIFIER

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

MeacoCool MC Series Portable Air Conditioner

PORTABLE AIR CONDITIONER (LOCAL)

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

PORTABLE AIR CONDITIONER (LOCAL)

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

LOCAL AIR CONDITIONER

Portable Air Conditioner USER MANUAL

PORTABLE AIR CONDITIONER

PC20-AMFII / PC40-AMF USER MANUAL

USER MANUAL TPS-M5/M55/M555

Mini Tower Fan NSMTF-18

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

WHYNTER PORTABLE AIR CONDITIONER

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

AC-12200E Portable Air Conditioner

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Portable Air Conditioner

MeacoDry ABC Range Dehumidifiers

POLOCOOL USER MANUAL. 10,000 BTU (2.9kW) 12,000 BTU (3.5kW) PORTABLE REFRIGERATED AIR CONDITIONER. For JULY 2017

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

15,000 BTU Portable Air Conditioner

IMPORTANT SAFETY INSTRUCTIONS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

PORTABLE AIR CONDITIONER (LOCAL)

12L Dehumidifier Model: HG00923

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Up to 60 Pint Commercial Grade DEHUMIDIFIER

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

ACCESSORIES INCLUDED

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

BLOW DRY & GO HAIR KIT

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Instruction Manual. Portable Air Conditioner

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Reverse Cycle Split System Air Conditioner

Operating Instructions

P O R T A B L E Air Conditioner

PORTABLE AIR CONDITIONER

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

1.6kW Window / Wall Air Conditioner

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

12,000 BTU Evaporative Portable Air Conditioner

Meaco 10L small home dehumidifier Instructional Manual

Imperial Electric Fires

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Convection Panel Heater

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

air conditioner/dehumidifier 9000btu/hr

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.


Certified to CSA STD. C22.2 No.117

PORTABLE AIR CONDITIONER MODEL NO: AC7000

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Dehumidifier Owner s Manual Read and save these instructions before use

IG9813 USER MANUAL. 12 Litre Dehumidifier White. Batch code:

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

40cm Pedestal Fan with Remote Control

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Dual-Hose Portable Air Conditioner User Manual

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Transcription:

EH0554 Indoor Climate Control 3.2kW heating or cooling capacity Air conditioning Dehumidification Cooling Efficient heating via air-source heat-pump Suitable for high- or low-wall installation No external unit required Page 1

IMPORTANT Installer and Users please note: These instructions should be read carefully and left with the user of the product for future reference. BEFORE USE Inspect the product including its cable and plug for any signs of damage. If the product is damaged, DO NOT use it, and contact your supplier immediately. Check that the following items are included: Page 2

INSTALLATION The appliance weighs 42kg. In order to comply with Health and Safety Manual Handling guidelines, two people will be required to lift it. Transport and store in an upright position. Leave the unit in an upright position for at least 3 hours before first use. Choose the optimum location for the appliance: It must be on an external wall with 2m free clearance on both inside and outside to allow good airflow The wall must be able to withstand the weight of the unit. The wall must be perfectly flat. There must be no electrical wiring, gas pipes, or structural steelwork in the wall in the area where the appliance is to be mounted. Attach the template to the wall using masking tape. Use a spirit level to ensure that it is perfectly level. Drill the fixing holes and insert wall plugs. Using a 160mm core drill, drill the two air intake holes. These should be drilled with a downwards slope of between 3 and 5 to make sure that any water will drain out. Using a 30mm masonry bit, or a core drill, drill the hole for the water drain. This MUST have a downward slope of between 3 and 5 to make sure that the water will drain out. Cut the air intake tubes so that they are 10mm less then the thickness of the wall. Attach the flanges for the air intake and exhaust tubes to the tubes using the 10 mm screws provided. Then fix the tube/flange assembly into the hole. If the outside wall is accessible, fill the area between the tubes and the wall using expanding foam, and attach the rubber rings to the outside of the Page 3

wall using the screws provided, then fit the drainage tube into the 30mm hole and seal with foam as above. If the outside of the wall is not accessible, proceed as follows. Attach the nylon cords to the rubber ring as shown. Fold the rubber ring in half and pass it through the hole, keeping hold of the other ends of the nylon cords. Slide the tube (with the inside flange attached) into the hole, passing the nylon cords through the tube. Seal the area between the tube and the hole with expanding polyurethane foam, and then push the tube completely into the hole. Attach the cords to the tabs on the interior flange and pull tight. Attach the hanging bracket to the fixing holes, using the screws provided. Stick the foam gaskets to the back of the unit, around the air intake and exhaust ports. Connect the drain hose provided to the rear drain outlet. A further extension pipe with an internal diameter of 16mm can be fitted if required. Care must be taken to ensure that the drain always runs downwards. With two people, lifting the appliance by it sides, not the front cover, hang it on the fixing bracket, and push firmly against the wall, ensuring that the drain pipe engages with the drainage hole, and that the main unit fits flush against the wall. If there are any gaps between the unit and the wall, heating and cooling performance will be impaired.if the drain pipe does not engage properly with the drain tube in the wall, leakage will occur. Page 4

Remove transit fixings from the compressor as shown. If the mains lead is fitted with a Schuko plug (with two round pins), either fit the 13A plug adaptor provided, or remove the Schuko plug and fit a 13A plug. Alternatively, remove the plug and wire to the mains supply via a switched fused spur. Remove the top cover, and fit the filters as shown. Finally, fit two AAA batteries to the remote control. PAT TESTING. When used in an office environment, this product must be safetytested yearly by a qualified electrician (PAT Tested) in order to comply with the Electricity at Work Regulations. We recommend that it is PAT tested regularly when used in a domestic environment. GENERAL SAFETY REQUIREMENTS Domestic wiring must be tested periodically by a qualified electrician at least once every 10 years or at every change of occupancy. For office and retail premises, and buildings such as village halls, the wiring must be inspected at least once every 5 years. It is recommended that all building be fitted with smoke alarms (it is mandatory for new buildings). Page 5

PRODUCT SAFETY This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance Ensure that there is at least 300mm (1') between the sides of the appliance and any flammable materials Ensure that there is at least 900mm (3') from the top of the appliance and any flammable materials. Do not place on soft surfaces. Do not cover. This symbol shown on the casing of the appliance means that the appliance should not be covered. For indoor use only Not suitable for use in boats, caravans or similar locations. Do not use in bathrooms, or in wet locations. Do not place the mains lead beneath a carpet or rug. Do not use the appliance in locations where paint, petrol or other flammable liquids are used or stored. Do not use unless correctly installed Do no insert any object into the appliance through the grilles. This may damage the appliance or result in overheating or electric shock. Do not place objects on top of the appliance. Do not obstruct the air intakes and exhausts OPERATION Plug the mains lead into a 13 Amp mains socket (unless permanently installed) If connecting via an extension lead, make sure that the lead is rated at 13 Amps or more, and that it is fully unwound. Switch the unit on at the mains socket. Page 6

Using the remote control press the "ON/OFF" button to start the unit. There will be a short delay (of about a minute) before the appliance starts to operate. Always use the ON/OFF button to start and stop the appliance. Do not switch off at the mains socket whilst it is running. This will reduce the life of the compressor. "MODE" Button: Select the mode by pressing the "MODE" button. The available modes are: AUTO = Automatic mode: either heats or cools as required to maintain the room temperature between 20 C and 25 C. The TEMP+ and TEMP buttons are inoperative in AUTO mode. COOL = Cooling mode: cools if the room temperature is above the selected temperature.then use the TEMP+ and TEMP buttons to select the desired room temperature. When the temperature reaches the desired temperature, the compressor will stop, and the fan will continue to run. DRY = Dehumidifying mode: removes humidity, but does not affect room temperature. The fan operates at its lowest speed. FAN = Fan only mode: circulates the air, but does not affect room temperature or humidity. HEAT = Heating mode: heats if the room is temperature is below the selected temperature. Then use the TEMP+ and TEMP buttons to select the desired room temperature. When the temperature reaches the desired temperature, the compressor will stop, and the fan will continue to run. Heating performance reduces if the outdoor temperature falls below 7 C "SPEED" Button: Set the fan speed using the fan speed control. In all modes except dehumidifying mode. The fan speed can be low, medium or high. The fan speed is indicated by the speed of the segments on the windmill symbol on the LED display. TEMP+ and TEMP buttons: Use the + and buttons to select the desired room temperature. The temperature can be set to any temperature from 16 C to 31 C. Selecting a lower temperature whilst heating, or a higher temperature whilst cooling will reduce power consumption. SLEEP MODE: The SLEEP mode is selected by the SLEEP button (and is indicated by the "moon" icon). In SLEEP mode, the Page 7

fan speed is set to its lowest speed. SWING button: Press the "SWING" button to turn the oscillation of the louvres on or off. FAN SPEED: The fan speed can be low, medium, high or automatic. When set to automatic, the fan speed is determined by the amount of cooling or heating required to maintain the selected room temperature. The fan speed is indicated by the number of segments lit adjacent to the symbol. INDICATORS The indicators on the main unit operate as follows: The two-digit LED display shows the current room temperature: The green LED (top left) indicates that the compressor is running (heating or cooling is taking place) The yellow LED (top right) indicates that the timer is operating, or if it is flashing, indicates that the unit is defrosting. The red LED (bottom right) indicates that the appliance is in standby. The blue LED (bottom left) indicates that the unit is in "sleep" mode. The LED OFF button on the remote control controls the display of room temperature on the front of the main unit. USING THE TIMER To program the time at which the unit will switch off, press TIMER button until the icon is displayed. Then set the number of hours before which the appliance should switch off by pressing the HOUR button. To cancel the timer, press TIMER until the icon disappears. To select the time at which the unit will switch on, press ON/OFF on the remote control to switch the unit off. Then press the TIMER button until the icon is displayed. Then set the number of Page 8

hours before which the appliance should switch on by pressing the HOUR button. To cancel the timer, press TIMER until the icon disappears. Setting the clock: To set the clock, first press the CLOCK button. Then adjust the time using the HOUR and MINUTE buttons. When the time shown is correct, press the CLOCK button again. OPERATING COSTS At time of going to press, the average cost of electricity is 0.11 per unit (kilowatt-hour). The amount you are being charged will be shown on your electricity bill. At this cost, the EH0544 will cost 0.12 per hour to run either cooling or heating. To minimise the power used (and reduce operating costs): Make sure that the filter is kept clean. Make sure that the air intakes and exhausts are not obstructed. Keep doors and windows closed to prevent conditioned air from escaping, and to prevent exhaust air from re-entering the room. Use blinds to prevent direct sunlight reaching the room. MAINTENANCE Before cleaning, turn the unit off using the button on the control panel (NEVER switch off the power at the mains socket whilst the unit is running). Wait until the unit stop and then disconnect from the mains supply. The case may then be cleaned using a damp cloth with a drop of washing-up liquid to remove any dust or dirt from the case. Do no use stronger detergents or solvents as these may damage the plastic. Using a dry 1" (25mm) paint-brush, remove any dust from the grilles. Page 9

Remove the filters from the top of the unit. Clean the active carbon Dust filter and catalytic filters using a vacuum cleaner. Active Wash the dust filter in hand-hot carbon water to which a drop of washingup liquid has been added. filter Catalytic Thoroughly dry before replacing filter in the unit. Using the appliance with a blocked filter will severely reduce its efficiency, and using without the filter may lead to a build-up of a dust on the heat exchangers, which may constitute a fire hazard. If the mains lead is damaged, it must be replaced by the manufacturer or an authorised service centre. If the mains plug needs to be replaced, proceed as follows: Connect the brown wire to the terminal labelled "L". Connect the blue wire to the terminal labelled "N". Connect the green/yellow wire to the terminal labelled with the earth symbol or "E". Make sure that the cord-grip is positioned correctly (over the outer sheath of the cable) and it fully tightened. DISPOSAL AND RECYCLING You must not dispose of this appliance with domestic household waste. Most local authorities have specific collection system for appliances and disposal is free of charge to the end-user. When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal. This air conditioner contains R410a refrigerant gas. At the end of its life the disposal of this product must be in accordance with local regulations. Page 10

FAULT-FINDING If the appliance is not operating, proceed as follows: Check that the mains plug is firmly in the socket, and that the socket is switched ON. When the unit if switched on there will be a delay of about 1 minute before it starts to operate. Unit stops running: Mains supply is disconnected or has failed Target temperature has been reached. Timer has been set. Water tank is full (E6 will be displayed) In cooling mode, no cool air is produced: Room temperature is lower than set temperature The unit is defrosting (this will take a few minutes, and afterwards, it will resume operation) Filter is blocked Cooling is poor on hot days Too much direct sunshine is heating the room Windows or doors are open allowing hot air into the room A lot of people in the room (each person contributes about 75W of heating) Electrical equipment in the room producing heat Remote control does not work: Check batteries are correctly installed, and are not exhausted. Make sure that the remote control is pointed towards the main unit when being used. Water leakage Drain hole slopes the wrong way Drain tube not fitted correctly Water splashes out of the front of the appliance Appliance has not been installed level. FAULT CODES If any fault codes appear on the display, contact your local service agent. E2: Indoor sensor failure E4: Indoor coil sensor failure E5: Failure of upper fan motor Page 11

TECHNICAL SPECIFICATION Dimensions: 550 930 260 mm Weight: 42 kg Power supply: 230V ~ Cooling capacity: 3200 W Heating capacity: 3200 W Power consumption (cooling): 1220 W Power consumption (heating): 1090 W Operating current: 5 A Air flow 400 m 3 /hour Noise level: 38 45 dba Dehumidification capacity: 21.6 litres/day Refrigerant gas: R410a SERVICE WARRANTY Prem-i-Air guarantees the product free from defects in materials and workmanship for a period of twelve months. This Elite product is guaranteed for a further twelve months subject to the enclosed registration card being completed and returned to the address printed on it, or the registration form being completed on-line at www.prem-i-air.com Should this unit be operated under conditions other than those recommended, at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit, then the warranty will be rendered void. The product you buy may sometimes differ slightly from illustrations. This warranty is in addition to, and does not affect, your statutory rights. If you have any problems with this product, please call our Help Desk on (0845) 459 4816. Prem-i-Air Appliances Ltd., Lancots Lane, Sutton, St. Helens, Merseyside. WA9 3EX website: www.prem-i-air.com Page 12