FiRe mobile-2 Operation Manual

Similar documents
ZP2 Series Operation Manual

KFP-CF Series Operation Manual

1X-F Series Installation Manual

NX-181xx NetworX Voice keypad with touch buttons User Manual

KFP-AF Series Fire Alarm Control Panel Installation Manual

Advisor Advanced Mobile Application User Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Advisor Advanced User Guide

My Visonic SMS App User Guide

Challenger Series Users Manual

Challenger10 Administrators Manual

Challenger10 Users Manual

KM300 Carbon Monoxide Detection System Installation Manual

user manual Document No , Revision 03 November 2015

Pet Immune SAW PIR Motion Sensor

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

900 Series Protocol Guide for 2X Series Control Panels

Monitoring Operator Guide. Access Control Manager Software Version

User Manual. Dryer Controller M720

Glass Break Sensor. Set-Up Guide

Using ANM Mobile CHAPTER

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

RINS App User Guide. Connect to your home or business from anywhere in the world.

Door/Window Sensor. Set-Up Guide

Document No Issue 4 user manual

HERCULES 6 GRAPHICS SYSTEM

Mobile App User Guide

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

IFS Fiber Module Installation & Operation Instructions

Patriot Systems Limited

UC-331-UCX Dual Path Communication Module. Quick Start Guide

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Carbon Monoxide Sensor

Dryer Controller M720

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

Avigilon Control Center 5 System Integration Guide

Protégé Eclipse LED Keypad User Manual PRT-KLES

Lighting Xpert Insight User Manual

IndigoVision Alarm Panel. User Guide

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

Alarm Manager Plug-in

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

IFS Fiber Module Installation & Operation Instructions

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

R Series Remote Annunciators and Expander Installation and Operation Guide

Added password for IP setup page : Password must be in IP format!

FEC403EN Installation Manual

Monitor Alarms and Events

Operator's Handbook. Interactive Fire Alarm System Release 3. Information Panel, BV-320. Protecting life, environment and property...

status AW1 Plus WiFi Alarm System User Manual

JOVY SYSTEMS RE User Manual Rev. 1.00

Operating instructions V-ZUG-Home

INTRODUCTION... VI I. IOS... 1

INTRODUCTION... VI I. IOS... 1

MPL3115A2 Sensor Toolbox User s Guide

Protégé EliteSuite Eclipse LED Keypad Installation Manual ELT-KLES

VESDAnet Interface Card Product Guide. Document Number: 10672_05 Part Number: 30071

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

RFT CARES Android App User Guide

Midco SmartHOME Quick Start Guide. Learn how to protect the things that matter most using this Midco SmartHOME instruction guide.

Installation, Configuration and User Manual

Halton SAFE / 7.14 user guide and installation instructions

Photo 5 Photo 6 Note: Once you connected the dehumidifier to the local network you can install the app on any other mobile phones and use Scan QR key

CODE ALERT Enterprise Software User Guide

Door/Window Sensor. Set-Up Guide

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

Simplex Panel Interface Guide

Patriot Systems Limited

Section 9 System Operation

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Avigilon Control Center 5 System Integration Guide

MultiSite Manager. Setup Guide

i on Compact Security System

DEFA HOME. User Manual Base Unit PRO

G4S SMARTalarm User Guide

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Fire Operator Workstation (Fire OWS) User s Guide

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

Version 1.03 January-2002 USER S MANUAL

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

SYSTEM 5000 USER MANUAL

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Laptop / PC Programming Manual

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Fire detection and alarm system Operating instructions

Cisco CallManager. Management Module Guide. Document 5116

Sensor Cloud User Manual

ZITON RADIO LOOP MODULE

Dashboard for Windows V1.1.0

IFS Fiber Module Installation & Operation Instructions

Proliphix. Remote Management. User Guide

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Transcription:

FiRe mobile-2 Operation Manual P/N 00-3230-505-0003-01 ISS 07JAN15

Copyright Trademarks and patents Manufacturer Version 2015 UTC Fire & Security. All rights reserved. The FiRe mobile-2 name and logo are trademarks of UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, Netherlands. REV 01. This product works with control panels with firmware version 3.2 or later. Contact information For contact information, see www.utcfssecurityproducts.eu/.

Content Important information ii Limitation of liability ii Advisory messages ii Getting started 3 Install the application 3 Connect to a fire network 3 The user interface 4 View the fire network status 5 Manage the fire network 6 Manage notifications 6 Reset a fire network or a control panel 7 Sound or silence sounders 7 Enable or disable features or devices 7 Perform a one-man walk test 9 View system events 12 Configure application settings 13 FiRe mobile-2 Operation Manual i

Important information Limitation of liability To the maximum extent permitted by applicable law, in no event will UTCFS be liable for any lost profits or business opportunities, loss of use, business interruption, loss of data, or any other indirect, special, incidental, or consequential damages under any theory of liability, whether based in contract, tort, negligence, product liability, or otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the preceding limitation may not apply to you. In any event the total liability of UTCFS shall not exceed the purchase price of the product. The foregoing limitation will apply to the maximum extent permitted by applicable law, regardless of whether UTCFS has been advised of the possibility of such damages and regardless of whether any remedy fails of its essential purpose. Installation in accordance with these manual, applicable codes, and the instructions of the authority having jurisdiction is mandatory. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions. Advisory messages Advisory messages alert you to conditions or practices that can cause unwanted results. The advisory messages used in this document are described below. WARNING: Warning messages advise you of hazards that could result in injury or loss of life. They tell you which actions to take or to avoid in order to prevent the injury or loss of life Caution: Caution messages advise you of possible equipment damage. They tell you which actions to take or to avoid for preventing the damage. Note: Note messages advise you of the possible loss of time or effort. They describe how to avoid the loss. Notes are also used to point out important information that you should read. ii FiRe mobile-2 Operation Manual

Getting started Install the application Install the application directly from your mobile device app store (ios, Android, Windows). See below for application and platform compatibility details. Platform Version Android 2.3 or later ios 5 or later Windows 8.0 or 8.1 Note: The SSL certificate must be installed onto Windows mobile devices manually for the application to connect to the server (contact your server administrator for more details). Connect to a fire network Connect to a fire network as described below. Note: If you want to test the application with a virtual fire network, leave Demo Mode on the Web servers screen checked. To connect to a fire network: 1. Launch the application. 2. Enter your PIN. If it s your first time using the application, you ll need to create your PIN and add a hint to help you remember it. You can change the PIN at any time in the application settings. 3. On the Web Servers screen, uncheck Demo Mode. If servers have previously been added, a list of the available servers is displayed. 4. Tap the server that you want to connect to, or tap Add new server to add a new server. For a new server, enter the server name, description, username, password, IP address, and port, and then tap Save details (If necessary, contact your server administrator for this information). You can change the server details at any time in the application settings. A list of the available fire networks for the server is displayed. 5. On the Fire Networks screen, tap the fire network that you want to connect to. The fire network status screen is displayed. FiRe mobile-2 Operation Manual 3

The user interface Figure 1: The user interface Item Name Description 1 Back arrow Tap the back arrow to go back. 2 Network name Tap the network name to view additional network details, such as the network description and regional mode setting. 3 Settings Tap the settings icon to configure the network, server, PIN, language, and alarm type settings, or to log out of the application session. See Configure application settings on page 13 for more information. 4 Events Tap Events to display a list of system events. 5 Front Reserved for future use. See View system events on page 12 for more information. 6 FN MGMT Tap FN MGMT to manage fire network options, such as acknowledging notifications, resetting the system or control panel, activating or silencing sounders, enabling or disabling system features or devices, or performing a one-man walk test. See Manage the fire network on page 6 for more information. 7 Status Tap Status to view the fire network status and to view alarm, fault, and condition event indications. See View the fire network status on page 5 for more information. 4 FiRe mobile-2 Operation Manual

View the fire network status Tap Status to view the fire network status and to view alarm, fault, and condition event indications. Note: Depending on your settings, the Alarm event counter displays the number of zones in alarm (the default setting) or the number of devices in alarm. Figure 2: The Status screen 1. Alarm, Fault and Condition event counters 2. Alarm, Fault and Condition event icons 3. Event type drop-down menu 4. Status indicator 5. Event order drop-down menu 6. Event details pane The Status indicator changes colour to indicate the current system status, as shown in Table 1 below. Table 1: Fire network status indications Status indicator Green Red Yellow Blue Description Indicates that there are no events Indicates one or more alarm events Indicates one or more fault events (and no alarms) Indicates one or more condition events (and no alarms or faults) Swipe up or down in the event details pane to scroll through the events. To filter the events: Tap the event icon (Alarm, Fault, or Condition) or the event type drop-down menu to filter the events by type (Alarm, Fault, or Condition) Tap the event order drop-down menu to filter the events by date (Newest First or Oldest First) FiRe mobile-2 Operation Manual 5

Manage the fire network Note: Access to some of the features described in this section may be restricted by the user level assigned to your user account. Tap FN MGMT to manage fire network options, such as acknowledging notifications, resetting the fire network or control panel, activating or silencing sounders, enabling or disabling system features or devices, or performing a oneman walk test. Figure 3: The FG MGMT screen Manage notifications From the FN MGMT screen, tap Notifications to display a list of notifications that require acknowledgment. The number of new notifications that require acknowledgement is indicated in the Notifications icon. To acknowledge a notification: 1. Tap Notifications 2. Tap Accept for the notification that you want to acknowledge, or tap Accept All to accept all notifications 3. Tap OK to confirm the acknowledgement 4. Tap Done 6 FiRe mobile-2 Operation Manual

Reset a fire network or a control panel From the FN MGMT screen, tap Reset to reset a fire network or a control panel. To reset a fire network: 1. Tap Reset 2. Tap Network, and then tap Reset To reset a control panel: 1. Tap Reset, and then tap Panel 2. Tap the panel that you want to reset Enter the control panel description in the search box to filter the list 3. Tap Reset Sound or silence sounders From the FN MGMT screen, tap Sound / Silence to sound or silence sounders. To sound or silence all sounders in the fire network: 1. Tap Sound / Silence 2. Tap Network, and then tap Sound or Silence To sound or silence all sounders for a control panel: 1. Tap Sound / Silence, and then tap Panel 2. Tap the panel with the sounders that you want to sound or silence Enter the control panel description in the search box to filter the list 3. Tap Sound or Silence 4. Tap Done Enable or disable features or devices From the FN MGMT screen, tap Enable / Disable to enable or disable features or devices. Examples of common enable and disable operations are shown below. For a complete list of the features and devices that can be enabled or disabled see Table 2 on page 8. To enable or disable a zone: 1. Tap Enable / Disable, and then tap Zone 2. Tap the zones search box A list of the available zones is displayed FiRe mobile-2 Operation Manual 7

3. Tap the zone that you want to enable or disable 4. Tap Enable or Disable 5. Tap Done To enable or disable a device: 1. Tap Enable / Disable, and then tap Devices 2. Tap the Panels search box A list of the available panels is displayed 3. Tap the panel with the device that you want to enable or disable, and then tap the Loops search box A list of the available loops for the selected panel is displayed 4. Tap the loop with the device that you want to enable or disable, and then tap the Devices search box A list of the available devices for the selected loop is displayed 5. Tap the device that you want to enable or disable 6. Tap Enable or Disable 7. Tap Done To enable or disable an output group: 1. Tap Devices 2. Tap the panels search box A list of the available panels is displayed 3. Tap the output groups search box A list of the available output groups for the selected panel is displayed 4. Tap the output group that you want to enable or disable 5. Tap Enable or Disable 6. Tap Done Table 2: Features and devices that can be enabled or disabled Feature or device Zone Devices Output groups Sounders Fire Protection Fire Routing Panel Inputs Description Enable or disable fire network zones Enable or disable devices Enable or disable output groups Enable or disable sounders Enable or disable fire protection Enable or disable fire routing Enable or disable control panel inputs 8 FiRe mobile-2 Operation Manual

Feature or device Panel Outputs Panel Zones Description Enable or disable control panel outputs Enable or disable control panel zones Perform a one-man walk test From the FN MGMT screen, tap OMWT to perform a one-man walk test for devices in a zone. The one-man walk test allows a single installation or maintenance contractor to easily test zone devices configured as DET or MCP. Figure 4: OMWT Session Details 1. Session stopped (red icon) 2. Session inactive (grey icon) 3. Session active or paused (green icon) 4. Session edit and delete icons To create a new OMWT session: 1. Tap OMWT 2. Tap Add new session 3. Tap the Select Zone search box A list of the panels and zones available to test is displayed 4. Tap the panel and panel zone that you want to test 5. Enter a name for the session in the Session Name field, and then tap Save The session details are now saved If prevous sessions exist (including sessions created by other users), they are displayed on the Session Details screen. FiRe mobile-2 Operation Manual 9

The session icon colour indicates the session status (inactive, active or paused, or stopped). See Table 3 below for more information on session status indications. Table 3: OMWT session status indications Session icon Grey Green [1] Red Description Indicates that the session is inactive. You can open, edit, and start the session. Indicates that the session is active or is paused. You can open, edit, and resume the session. Indicates that the session has been stopped. You can open and review the session details. You cannot restart or edit a stopped session. [1] The session status remains active even if the application is closed or the network connection is lost during the OMWT session. Figure 5: OMWT session in progress 1. Test progress bar and statistics 2. Device icons 3. Play/Pause 4. Stop 5. Reports To start an OMWT session: 1. Tap OMWT. 2. On the Session Details screen, tap the session that you want to start. A list of zone devices is displayed. Each device type has a unique icon (see Table 4 on page 11). 3. Tap Play to start the session. 10 FiRe mobile-2 Operation Manual

4. Test the first device. If the device test is successful, the mobile device beeps and vibrates to confirm the test result and a green border is added to the the device type icon. If no confirmation is received, repeat the device test or tap the device icon, and then tap Failed to indicate a device failure. If the device test is marked as failed, a red border is added to the the device type icon. To re-test a device marked as passed (green border) or failed (red border), tap the device icon, and then tap Re-test. Any comments added when selecting Failed or Re-test for a device are included with the device details in the OMWT session report. 5. Continue testing the zone devices. 6. Tap Pause to pause the the session temporarily, or Stop to end the session when testing is complete. You cannot restart a stopped session. Table 4: Device type icons Icon Device type Multisensor Optical or ionisation detector Heat detector Manual call point Zone monitor unit Supervised output module Relay output module Sounder module Sounder (generic) Supervised input module Extinguishing control unit FiRe mobile-2 Operation Manual 11

Icon Device type I/O module (1 input, 1 output) I/O module (2 input, 2 output) I/O module (2 input, 1 output) I/O module (4 input) I/O module (3 input, 3 output) I/O module (4 input, 4 output) I/O module (1 input) To send an OMWT session report: 1. Tap Report 2. Add comments to the session report 3. Tap Mail 4. Enter the email address 5. Tap send View system events Tap Events to view a list of system events. The ten most recent events are displayed. Tap Load more events to display the next ten events. Swipe up or down to scroll through the displayed events. To filter the events: Tap the event type drop-down menu to filter the events by type (All, Alarm, Fault, or Condition) Tap the event order drop-down menu to filter the events by date (Newest First or Oldest First) 12 FiRe mobile-2 Operation Manual

Configure application settings Tap the settings icon (Figure 1 on page 4) to configure the network, server, PIN, language, and alarm type settings, or to log out of the application session. Tap Network to change the fire network. Tap Server to change the current server or to add a new server. Tap Change PIN to change the application PIN. Tap Language to change the application language. Tap Alarm Type to configure the alarm type setting for the alarm event counter on the Status screen (zones in alarm or devices in alarm). The default setting is Zone. Tap Logout to end the application session. FiRe mobile-2 Operation Manual 13