Onsite Fire Risk Reduction Methods

Similar documents
Onsite Fire Risk Reduction Methods. Marc Rivard, PE, SE WoodWorks

Renovation Program. Renovation Program GENERAL

OUTLINE FOR FIRE PREVENTION ACTIVITY

2010 FIRE CODE OF NEW YORK STATE

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

Construction and Development Guide

Stillwater Area Community Services Center Inc.

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

Fire Prevention Plan

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Fire Prevention Plan for Campus Services Building 1630 Musketeer Drive

Fire Prevention Plan

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Fire Prevention Plan for Residence Life 1625 Musketeer Drive

General Safety Requirements

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

EXAMPLE FIRE PREVENTION AND PROTECTION PLAN WORKSHEET

Hot Work Policy. Department of Risk Management. 1. Purpose. 2. Authority. 3. Scope

Safe Operating Procedure

Risk Management Services

Builders Risk - Fire Prevention Inspection Checklist

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY

FIRE RISK ASSESSMENT Self Assessment

The general safety requirements in the IFC were developed to. General Precautions Against Fire CHAPTER

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

Special Occupancy Requirements

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

HOT WORK SAFETY PROGRAM:

B. The Facility Emergency Planners and Alternate Planners will successfully complete the in-house DJJ Fire Prevention course.

Fire Safety Plan Information. For Construction and Demolition Sites

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Procedure DESCRIPTION/OVERVIEW

Safety Manual Section 7 Fire/Life Safety

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

Code Red Consultants- Fire Door Inspection, Testing, and Maintenance 1/5/2018. Learning Objectives. NFPA 241 Implementation

OPERATIONAL PERMIT STORAGE MAGAZINE PERMIT APPLICATION

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire Prevention Plan for

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Business Fire Inspection. City of Guadalupe

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

This policy applies to all Hot Work jobs performed on the Calhoun mill property by AbitibiAbitibiBowater employees.

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

FIRE PREVENTION AND PROTECTION FACT SHEET

OUR MISSION. OUR MISSION is to promote secure

The Social Accountability International (SAI) Fire Safety Checklist

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

Temporary Haunted Houses

Fire Prevention Plan for Cintas Center 1624 Musketeer Drive

Fire Prevention Plan Program

Fire Prevention Plan for Alumni Center 1507 Dana Avenue

Department Of Public Works: Internal Operations

Welcome to the Keys to a Successful Fire / Life Safety Inspection and Sustained Tenant & Building Safety

Introduction. Program Description. Section C.20 University of South Carolina Safety Program Guide FLAMMABLE AND COMBUSTIBLE LIQUIDS

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

Hot Work Policy and Procedures

FIRE SAFETY INSPECTION REPORT

Fire Prevention Plan for McGrath Health and Wellness Center 1714 Cleneay Avenue

Large Family Daycare Guideline

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Date Issued: December 14, 2017 Revision: 2.1

Bloomsburg University of Pennsylvania Hot Work Safety Program Effective Date: July 1, 2015

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

Written Fire Safety Plans

OFM-TG FIRE SAFETY PLANNING FOR RECYCLING FACILITIES AND WASTE PROCESSING OPERATIONS

BCIT FIRE SAFETY PROGRAM

Impairments to Fire Protection Equipment

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

Attention: Sharon Dickinson, Legislative Assistant, Planning and Land Use Management Committee

Board Policy 6819 Fire Safety and Prevention Plan

Table of Contents. EMERGENCY PROCEDURES Policy 190

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

INSPECTOR I SKILLS ADMINISTRATION

Fire Safety Plan Training 2017

Fire Safety Safety Program

5 Key Stages to Risk Assessment

Fire Safety. Version 1.0

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

Progressive Safety Services LLC 2

The general safety requirements in the IFC were developed to. General Precautions against Fire CHAPTER

Demolition Permit Application (Please print and complete ENTIRE form)

FIRE PREVENTION STANDARDS

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

Hot Work Program & Operational Guidelines. Environmental Health, Safety and Emergency Management (828)

Vacant Building Loss Prevention Best Practices

South Davis Metro Fire Agency

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Fire Drill Requirements Group E Occupancies

Transcription:

Onsite Fire Risk Reduction Methods

Outline Construction Fire Background Site Safety Code Requirements Construction Fire Safety Practices Additional Resources

Construction Fire Statistics According to NFPA, 2007-2011: 38,000 wood-frame apartments constructed 550 non-confined structure fires 1.4% of apartments constructed 209,360 non-confined structure fires in all apartments & family homes Only 0.9% of these occurred during construction

Construction Fire Statistics According to NFPA, Construction Fires in Multi-Family: Most likely to start on lower floors of a multistory building (76% started on 1 st or 2 nd floor) Not tied to increased height of buildings

Causes of Construction Fires US Fire Administration has identified 6 causes of construction site fires: Hot Work Smoking Heating Devices Electrical Malfunctions Cooking Fires Criminal Activity and Vandalism

Construction Fire Safety in the Code

Construction Fire Safety in the Code Base Building Codes: California Building Code (CBC) Chapter 33 & References CFC California Fire Code (CFC) Chapter 33 NFPA Standards: NFPA 1 Chapter 16 NFPA 241

Construction Fire Safety: CBC CBC Chapter 33: Safeguards During Construction CBC Section 3302.3 Fire safety during construction. Fire safety during construction shall comply with the applicable requirements of this code and the applicable provisions of Chapter 33 of the California Fire Code

Fire Extinguisher (CBC 3309) During construction, one portable fire extinguisher must be placed at: Each stairway on all floor levels with combustible materials Each storage or construction shed and where special hazards exist

Standpipes (CBC 3311) A minimum of one standpipe must be available during construction for fire department use. The standpipe is installed before the construction is 40 feet above fire department access.

Sprinkler System Commissioning (CBC 3312) Sprinkler system must be tested and approved before the certificate of occupancy is awarded

Construction Fire Safety: CFC Additional requirements for fire safety during construction are contained in CFC Temporary heating equipment must be listed and labeled (3303). Smoking is prohibited except in approved areas with posted signage (3304.1). A fire watch must be maintained with qualified personnel if required by the fire code official (3304.5).

Construction Fire Safety: CFC Welding operations must follow the provisions of IFC Chapter 35. Electrical wiring must comply with NFPA 70 (IFC 3304). The owner must designate a fire prevention superintendent responsible for the fire prevention program during construction (3308). An accessible emergency phone must be provided in an approved location at the construction site (3309).

OSHA Requirement: Fire Protection Plan OSHA 1926.150: The employer shall be responsible for the development of a fire protection program

Construction Fire Safety Construction Fire Safety is not a new concept Issue is not lack of codes that address this Issue is lack of enforcement & lack of compliance Construction Fire Safety necessitates functioning as a team, upholding a higher level of accountability, compliance & enforcement What resources are available to assist with this?

Construction Fire Safety: CFC ConstructionFireSafetyPractices.com

Construction Fire Safety Practices Collaborative Effort of: American Wood Council Industry Based Stakeholders Group FireForceOne (fire protection consultant) Goal: Provide information to public & private sector organizations regarding how to reduce the frequency and severity of fires during construction

Construction Fire Safety Practices Builds on existing code requirements to add guidance, based on the premise: Fire is No Accident Information can be incorporated in: Fire Protection Plan Safe Work Methods Hot Work Permit System Fire Protection Policy & Procedures

Construction Fire Safety Practices 3 Manuals: Basic Fire Precautions During Construction Hot Work During Construction FD Response to Fires During Construction

Construction Fire Safety Practices 7 Short Videos, Discuss: Generating & Enforcing a Fire Protection Plan Hot Work Best Practices (Welding, Soldering) Fire Department as a Partner Clean Job Site Job Site Security More

Fire Protection Plan Some Jurisdictions Provide FPP Templates General Safety Guidelines Include: Fire safety is everyone s responsibility Provide fire safety orientation & training for all on site, including sub-contactors Report fire hazards immediately

Construction Fire Safety Practices Fire is No Accident: No Smoking on Job Site Many utilize a zerotolerance policy: one strike and you re out

Construction Fire Safety Practices Fire is No Accident: Clean Construction Waste, Debris Use FPP to require routine, scheduled cleaning

Construction Fire Safety Practices Fire is No Accident: Clean Construction Site Waste from drilling for MEP, cutting wood (sawdust, wood chips) should be cleaned immediately Can create significant fire load Safely secure flammable liquids

Construction Fire Safety Practices Fire is No Accident: Provide Requirements for On-Site food preparation equipment Proper regulation of temporary heating equipment Proper use & maintenance of construction equipment

Hot Work Best Practices Hot Work Permitting System Identifies where each day s hot work is taking place Allows site supervisor, field personnel & security personnel to readily identify key areas

Hot Work Best Practices Maintain hot work watchman Located adjacent to any hot work taking place Armed with fire extinguisher, looking to spot any sparks, etc. from hot work Check area after hot work is complete

Fire Service As a Partner Maintain good communication & relationship with local fire service Provide frequent updates on water supply connection locations, status of passive & active fire protection measures Maintain access points

Site Security & Safety Off-hours more prone to vandalism, arson Should plan walk-through of entire building, especially in areas of that day s hot work Physical presence & video surveillance are key Proper fencing, locks, other security measures as necessary to prevent unauthorized access

Construction Fire Safety Practices Stop Fire Before it Starts Enforce & Maintain Code Requirements for Construction Site Fire Safety Generate & Follow Fire Protection Plan Involve Fire Service as a Key Partner Open Communication A Fire-Free Project is in Everyone s Best Interest

Construction Fire Safety Practices Awareness Action Accountability

Additional Resources WoodAware.com

Additional Resources: WoodAware.com Wood products primer guide with specific fire performance & fire service interaction Info on adhesives, smoke toxicity, charring & more

Additional Resources ModernFireFighting.com

Additional Resources: ModernFireFighting.com Provides information for fire service to educate on reaction of different building materials in fire events to enhance situational awareness & tactical preparedness Collaborative effort of US Fire Administration, AWC & Fireforceone

Questions? This concludes The American Institute of Architects Continuing Education Systems Course Speaker Name Speaker organization Speaker email address

Copyright Materials This presentation is protected by US and International Copyright laws. Reproduction, distribution, display and use of the presentation without written permission of the speaker is prohibited. The Wood Products Council 2017