IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

KOMFORT EC DB Suspended heat recovery air handling units

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

KITCHEN EXTRACTORS K Series

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Lo-Carbon Sentinel Kinetic Horizontal

Airflex Radial & ISO Thermal pipe

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

ENG. IDEO 325 Ecowatt. Installation Manual

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Small Room Heat Recovery Ventilation

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Air distribution systems. Opticlean OC-Q...

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Rotary heat Thermal Wheel recovery unit. Plate heat exchanger recovery unit No condensation drain required. Wall mounted

The Sentinel Kinetic Horizontal Range

Cassette units Model Comfort Circle. - heating - cooling - ventilation

INSTALLATION INSTRUCTION & OWNER S GUIDE

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Smoke extraction duct of sheet steel

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

VERTICAL FAN COIL UNITS

Installation and Maintenance

Air distribution systems. Opticlean OC-Q... DS 4136 E /1

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Ceiling diffusers. Type DLQL

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

UniTrane Ductable Units D-line and B-Line

CADB/T-D DP25 F7 Series CADB/T-DI DP25 F7 CADB/T-DC DP25 F7. Heat recovery units CADB/T-D

Aegean Range. A new range of fan coils for heating and cooling commercial applications

10-year industry best core warranty. 5-year warranty on balance of unit.

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS

Blower-YEFB-020-3R-1maxVel

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Healthy, comfortable and energy-efficient ventilation

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

HOTLINE:

Sentinel Demand Energy Recovery Ventilation

FAN COIL UNITS. The optimal solution for limited space

CI/SfB (57.7) 2nd edition

Ceiling swirl diffusers

Ceiling swirl diffusers

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

HEAT RECOVERY AIR HANDLING UNIT

Installation and Maintenance

Installation and Maintenance

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

Heat recovery unit RDKS

QZB "Standard" comfort fan coil

WHHR Midi & Midi Lite

Units for suspended ceilings

TECHNICAL SPECIFICATION

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Heater with Air Conditioning. E-Series Ford Aeromaster

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

For details of the full range of Wholehouse Heat Recovery Systems please refer to the Vent-Axia Clean Air Systems Brochure

(57.7) X. March 2006 PRODUCTS. ... the complete solution

CASSETTE UNIT. Comfort Circle

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

ENERGY RECOVERY VENTILATION (ERV)

Installation and Maintenance

Concealed ceiling unit with medium ESP

Transcription:

AKOR ST HR Series AKOR ST HR Balanced-airflow for single dwelling houses, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling houses up to 92% of efficiency. It connects, via ducting, to extraction outlets in each of the wet rooms. The fresh air that has been pre heated enters the rooms through supply air vents. Equipped with 2 centrifugal fans (a supply and an extract fan), each with a 23V-5Hz motor, Class B, 2-, designed for continuous operation, and terminal housing to connect the power supply cable. Specific applications Single dwellings Heat recovery unit Easy maintenance and filter cleaning. Efficient counter flow heat exchanger High efficient counter flow heat exchanger, manufactures from polypropylene plates. Drain Permanent drain to evacuate condensation water. Integrated rubber seals Circular connection flange with Integrated rubber seals. Switch Incorporated switch (Extract/Input). 2 extract positions with stop. 2 input positions with stop. www.solerpalau.com Heat recovery units AKOR 155

AKOR ST / AKOR ST GD Series AKOR ST GD Balanced-airflow for single dwelling houses, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling houses up to 6% of efficiency. It connects, via ducting, to extraction outlets in each of the wet rooms. The fresh air that has been pre heated enters the rooms through supply air vents. Equipped with 2 centrifugal fans (a supply and an extract fan), each with a 23V-5Hz motor, Class B, 2-, designed for continuous operation, and terminal housing to connect the power supply cable. Specific applications Single dwellings Heat recovery unit AKOR ST D15 AKOR ST GD D15 Easy maintenance and filter cleaning. Efficient cross flow heat exchanger High efficient cross flow heat exchanger, manufactures from polypropylene plates. Drain Permanent drain to evacuate condensation water. Integrated rubber seals Circular connection flange with Integrated rubber seals. Switch Incorporated switch (Extract/Input). 2 extract positions with stop. 2 input positions with stop. 156 Heat recovery units AKOR www.solerpalau.com

Reference A K O R - S T G D D 1 5 1 2 3 1 - AKOR ST: Serie. 2 - GD: High power fan. HR: High efficiency core. 3 - D15: Connection diameter. Technical characteristics Before installation check that the product electrical characteristics listed on the data plate label (voltage, power, frequency, etc.) match those of the intended electrical supply. Model Voltage (V) Power absorbed at free discharge (Maximum) (W) Configuration AKOR ST D15 23 132 1 inlet bellmouth 15 mm 15 48 AKOR ST GD D15 23 27 1 inlet bellmouth 15 mm 16 48 AKOR ST 23 132 AKOR ST GD 23 27 AKOR ST HR 23 132 * See section of Wiring Diagrams. 4 inlet bellmouth 8 mm 1 inlet bellmouth 125 mm 4 inlet bellmouth 8 mm 1 inlet bellmouth 125 mm 4 inlet bellmouth de 8 mm 1 inlet bellmouth 125 mm Weight (kg) Wiring diagram* (nº) 15 48 16 48 16 48 Performance curves The curves correspond to each of the 2 fans that each AKOR model incorporates. [Pa] 24 [mmwg] 24 AKOR ST D15 AKOR ST - AKOR ST HR [Pa] [mmwg] AKOR ST GD D15 - AKOR ST GD 5 5 2 2 16 16 4 4 12 12 3 3 8 8 High 2 2 4 4 Low 1 2 3 qv [m 3 /h] 1 1 Low High 1 2 3 4 qv [m 3 /h].2.4.6.8.1 qv [m 3 /s].2.4.6.8.1 qv [m 3 /s] www.solerpalau.com Heat recovery units AKOR 157

Efficiency curve Outdoor temperature: 5ºC. Outdoor relative humidity: no significant. Indoor temperature: 25ºC. Indoor relative humidity: 3%. AKOR ST D15 - AKOR ST GD D15 Rendimiento recuperador AKOR ST - AKOR ST GD (%) 75 7 65 6 55 5 5 8 1 12 14 16 18 2 qv [m 3 /h] η(%) AKOR ST HR 95 94 93 92 91 9 89 88 87 86 85 5 1 15 2 25 3 35 qv [m 3 /h] Dimensions 786 427 668 Ø125 427 Ø8 158 Heat recovery units AKOR www.solerpalau.com

Installation examples Ø6 CD Supply air DERIV 125/6P DERIV 125/6-6P DERIV 15/6-6-125P Ø125 Ø125 Extraction maxi 5m maxi 12m Interior air Fresh air CD DERIV 125/6-6 P DERIV 125/6 P DERIV 15/125-125 P Supply air Extraction DERIV 125/6-6 P DERIV 125/6 P Ø 15 Ø maxi 5m Interior air Fresh air Supply air Extraction Ø 15 Interior air Fresh air www.solerpalau.com Heat recovery units AKOR 159

Accessories ABE D.5 Defrosting unit Prevents the formation of ice from the condensation on the interchanger plates in the air extract. Made from galvanized steel plate and supplied with polyethylene clips. It has a heat resistance of 5W and control thermostats. ABE/CORIS Heating unit Allows the temperature of the blown air to be increased. It has a 5W power heating element and control thermostats. TAT Air inlet for false ceiling mounting TAP Air inlet wallmounted BOA/BOAC Inlet valves BOA 8/125. BOAC 8/125. CT Plastic roof terminal cowl CD Intake grille Designed to introduce air into individual houses. It can be installed on a wall, ceiling or on straight or inclined ceiling tiles. Diameter 6 mm. Plenum AKOR 1 inlet spigots in Ø6 mm. Outlet spigot in mm. 5 covers. DERIV Duct fittings. Ø C Ø D Ø B Model Ø A Ø B Ø C DERIV 8-8 P 8 8 8 Ø D DERIV 125-6-6-125 P 125 6 6 125 DERIV 125-6-6-125 P 125 6 6 6 Ø A DERIV 15-125-125 P 15 125 125 DERIV 15-6-6-125 P 15 6 6 125 16 Heat recovery units AKOR www.solerpalau.com