TM Integrated SensorDIM ED Driver Daylight Monitoring Version Model: HEC730 with HRC-0.1 ED + ED - ED current selection 0 9 Daylight threshold Antenna module connector Buzzer ] PUSH Extended antenna 99 10 22.2 Model: HEC730 Mechanical structure (mm) Further 20% saving Detection Pattern 0 Daylight Monitoring TM 2s~30min 2~0ux Ambient daylight threshold 2 in 1 and cost effective! This is a smart integration of HF (microwave) motion sensor and multiple current selection ED driver, which gives pre-selected constant current to drive the EDs to work based upon movement detection. Designed in the software and thanks to our worldwide patented circuit, the built-in daylight sensor is prior to motion sensor so as to achieve utmost energy saving purpose. With the detached sensor antenna SAM, it requires very little space on the ED panel. Only the antenna is installed on the surface, while the main body can be hidden behind the panel. Completely shadow free. Detached sensor antenna module: Model SAM Infrared remote receiver 3.9 Cable side entry Super-compact sensor antenna, with optional cable entry (side entry and back entry) 30.7 0. 2. 2.2 13 11.2.. Cable back entry Hytronik High frequency motion sensor 7
Product Functions and Features 1 Daylight monitoring function with threshold control 2 Tri-level control (corridor function) 3 Synchronization function Wall switch manual override (push function) Semi-auto function(absence detection) Further 20% saving @ initial 10,000 hours 7 ED current multi-selections 1 2 3 900mA 70mA 700mA 0mA 00mA 30mA Current The current can be easily configured by choosing the correct combination of the DIP switches (see table on the left). ED maximum load and voltage This multiple current ED driver has a wide range of loading capacity: Maximum load @ different currents: 3.~17.W (30mA) ~2W (00mA).~2W (0mA@277V) /.~2W (0mA@120V) 7~30W (700mA@277V)/ 7~2W (700mA@120V) 7~30W (70mA@277V) /7~2W (70mA@120V) 9~23W (900mA) Maximum voltage @ different currents: 10~0V (30mA) 10~0V (00mA) 10~V (0mA@277V)/ 10~V (0mA@120V) 10~3V (700mA@277V)/ 10~3V (700mA@120V) 10~0V (70mA@277V)/ 10~33V (70mA@120V) 10~2V (900mA) Settings (Remote Control HRC-0) O/ OFF Permanent O/OFF function Press the O/OFF button, the light goes to permanent on or permanent off mode, sensor is disabled. * Press Auto Mode, RESET or Scene mode buttons to quit from this mode. Auto Mode Sensor mode Press Auto Mode button, the sensor starts to work and all settings remain the same as the latest status before the light was switched on/off. O/ OFF SC1 SC3 100% Scene mode Auto Mode SC2 SC 20% 0% 0% Reset 100% + Dim - Daylight Sensor 2ux Reset function Press RESET button, all settings go back to the value of DIP switch settings. Test 2s min 30s 1min 30min 0s 10s 1min 10ux min 0ux ux Dim +/- ong press Dim + or Dim to adjust the light brightness between ~100% during hold-time. + means dimming up, means dimming down. 30min M/A HRC-0 ote: the buzzer beeps one time when RC receives signal successfully. 77 Hytronik High frequency motion sensor
Test mode The button Test 2s is for testing purpose only. The sensor goes to test mode (hold-time is 2s) automatically after commissioning, meanwhile the stand-by period and daylight sensor are disabled. * This mode can be ended by pressing reset, or any button of scene mode and hold time. The sensor setting is changed accordingly. M/A Manual override / absence detection By pressing this button, the sensor goes to manual override or absence detection / semi-auto function. ote: The buzzer beeps twice if it s manual override function, and beeps once if shifts to absence detection function. 100% 0% output Press these buttons to select full output level. 0% button allows for energy saving and reverse dimming to compensate for ED lumen depreciation over time. Supports fluorescent 10,000 hr initial burn-in. ux ux disable Press this button to disable the daylight sensor for threshold control. When motion is detected, the fixture will always turn O, regardless of ambient light level. Ambient daylight threshold Press this button, the latest surrounding lux value overwrites previous lux value learned, and is set as the daylight threshold. This feature enables the fixture to function well in any real application circumstance. Scene mode There are four scene modes fixed programs built-into the remote control. Select as appropriate. Each scene can be modified using the remote. The sensor will remember updates even after power outage. The green RESET button on remote reverts to original defaults. Scene options SC1 100% 1min 2ux SC2 100% min 2ux SC3 100% 30min 10ux SC 100% 0ux ote: end-user can adjust the settings by pressing buttons of detection range/hold-time/stand-by period/stand-by dimming level/daylight sensor. The latest setting stays in validity. Select as appropriate to adjust/reduce sensor sensitivity, detection range from 100%. Typical 100% sensor motion detection range is 9m. Please refer to detection pattern below. is time fixture remains at programmed full power level AFTER no motion is detected. Select daylight sensor threshold level at 2 UX / 10ux / 0UX. Ambient light must below this UX threshold for sensor to turn fixture O. Press Blue button to sample ambient light. Press ux button for fixture to always turn On when motion is detected. (tri-level control) Press the buttons of stand-by period to set stand-by period at 0s / 10s / 1min / / 30min / +. ote: 0s means on/off control; + means bi-level control, light never switches off when daylight sensor is disabled. Hytronik High frequency motion sensor 7
0 Press the buttons of stand-by dimming level to set the stand-by dimming level at / 20% /. Wiring Diagram_ Wiring Diagram_ + Maximum 10pcs ED+ ED- ED+ ED- ED+ ED- ED+ ED- Switch Dim Switch Dim Detection Pattern 0 9 Ceiling mounted height (m) 0% 7% Wall mounted height (m) 0% 7% Ceiling mounted detection pattern (m) Wall mounted detection pattern (m) Settings 1 can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. ote: by choosing Sensor OFF, it becomes a dimmable driver without sensor mode. 1 2 100 % 7% 0 % Sensor OFF I 100% II 7% III 0% IV Sensor OFF 2 means the time period to keep the lamp on 100%, after all motion has ceased (detection area vacated). ote: the maximum brightness during hold-time can be overridden by long push on the push-switch. 3 s 30s 3min I s II 30s III 3min IV 79 Hytronik High frequency motion sensor
3 The daylight threshold can be set on DIP switches, to fit for particular application. 0ux 10ux ux I II 0ux III 10ux IV ux (tri-level control) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. ote: 0s means on/off control; + means bi-level control, fixture never switches off when daylight sensor is disabled. 7 0s 10s 30min + I 0s II 10s III 30min IV + This is the dimmed low light output level you would like to have after the hold-time in the absence of people. 9 I II Technical Data Operating voltage Input current Input power Stand-by power Warm time Daylight threshold HF (microwave) frequency HF (microwave) power Detection angle Mounting height Output ED current Output ED voltage Output ED power Empty load voltage factor Efficiency Operating temperature Abnormal protection EMC standard Safety standard Certification Dielectric strength Max. case temperature (Tc) IP rating 120-277Vac 0/0Hz 0.2-0.1 A 31W (Max.) < 0.W 20s Sensor OFF/0% /7% /100% (100% /0% / on RC) s /30s /3min / (TEST 2s/30s /1min /min / /30min on RC) ux/10ux/0ux/disable (2ux /10ux / 0ux /ux disable on RC) 0s/10s/30min/+ ( 0s /10s / 1min / / 30min /+ on RC) / (/ 20%/ on RC).GHz+/-7MHz <0.2mW Max. (OxH): 12m x m 30 o ~10 o Max. m 30mA/00mA/0mA/700mA/70mA/900mA 10~0V (30mA) 10~0V (00mA) 10~V (0mA@277V)/ 10~V (0mA@120V) 10~3V (700mA@277V)/ 10~3V (700mA@120V) 10~0V (70mA@277V)/ 10~33V (70mA@120V) 10~2V (900mA) 3.~17.W (30mA) ~2W (00mA).~2W (0mA@277V) /.~2W (0mA@120V) 7~30W (700mA@277V)/ 7~2W (700mA@120V) 7~30W (70mA@277V) /7~2W (70mA@120V) 9~23W (900mA) 0V >0.9 % (Max.) -20 o C ~ +0 o C Output short-circuit protection with auto-reset Part 1B U 70 cuus listed, FCC Inputoutput:370Vac /ma/1min 7 o C IP20 Hytronik High frequency motion sensor 0