The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration

Similar documents
Tier1 Water Home Filtration System

Tier1 Water Home Filtration System

89 BIF/BAF USER MANUAL

765 Valve Filters (Taste & Odor, Nextsand, Multimedia, Neutralizer)

565 TLC Softener & Tannins Reduction System

485CLA Chloramine Reduction System. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

Installation and Operation Manual

565 HIM Softener, Iron & Manganese Reduction System

Installation and Operation Manual

Installation and Operation Manual

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

Econoflo Water Conditioner. Installation and Maintenance Instruction Manual

765 IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

85 TA 1 High Efficiency Twin Alternating Water Softener

HTO 185HEUF Hardness, Taste & Odor Reduction System

785 HIM Softener, Iron & Manganese Reduction System

Table of Contents. Unpacking / Inspection

785 Upflow Water Softener

485HTO Hardness, Taste & Odor Reduction System

Installation & Service Manual

485SIM Softener, Iron & Manganese Reduction System. Proud member of Canadian Institute of Plumbing & Heating.

565IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

Installation and Operation Manual

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

WG185 IronGuard SIM Series

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

6700XTR Valve Downflow

1850 Series TRIPLE TREAT Operation Manual

US Water Ultimate Dual Tank Superfilter

185HE IS Greensand Filter. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

Hybrid Water Softener

Commercial Water Softener

485HE High Efficiency Water Softener

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

FUSION PROFESSIONAL-GRADE METERED NITRATE REMOVAL SYSTEM

MP-MBA-45T-1/60T-1 / 75T-1

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

Whole House Filter Model: WH-LD

7000 Meter Initiated Valve

Metermatic Water Softener. Operation Manual

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

Clean Water Made Easy

High Flow 7000 SXT Series Water Softeners

Owner's Manual. WS Series. Water Softener

7800 Neutralizer Installation & Start-Up Guide

CWS Plus Sediment Filter Installation & Start Up Guide

Econoflo SXT Automatic Meter Initiated Water Softener

Installation and Operation Manual

Green Water Systems OWNERS MANUAL. Includes: Installation Procedures, Warranties, Service & Operation Guidelines.

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

2-Stage Under Counter Filtration System Model: WP-2 LCV

Fleck 5600 Carbon Filter Installation & Start Up Guide

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

IMPORTANT SAFETY INFORMATION READ ALL...

WHOLE HOUSE FILTER &

ispring Whole House Water Filter Systems USER S MANUAL

Installation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C

Installation Manual & Owner s Guide

ProFlo SXT Valve Downflow / Upflow

5700-E Sediment Filter Installation & Start-Up Guide

High Flow 7000 SXT Water Softener

Installation, Operation, and Maintenance Manual. Waterlogix Metered Residential Water Softener

Installation and Operation Manual

Clean Water Made Easy

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

Genesis Whole House Chlorination System Page 2

7500-S Sediment Backwash Filter Guide

Owners Manual 89DF HIMTLC PLUS

NovoSoft 465 Series SIM Water Softener Operation Manual

Clean Water Made Easy

Fleck 7000 Sediment Filter Installation & Start-Up Guide

Installation Instructions PP-AS20 Anti-Scale System

Water Softener Installation / Operation Manual

Kinetico 2060f OD Sulfur Guard Installation Instructions

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

Owners Manual. 900 Series Drinking Water Appliance

Owners Manual 89 BIF/BAF. Chemical Free Iron Filter

Owners Manual Models: 080-MXX-100, 080-MXX-150, 080-MXX-200, 080-MXX-250. US Water Systems Matrixx Commercial Water Softener

GE & PROFILE SmartWater Softener Systems

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Installation, Operation, and Maintenance Manual

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

OWNER S MANUAL. Premium Series Two Tank 1-PLUS-1 Water Conditioner & Whole House Filters

Clean Water Made Easy

Installation, Operation and Maintenance Manual

Fleck 2510 Softener Installation & Start Up Guide

The WateRx Plant. Features/Benefits. Applications (for municipal water usage) Great water throughout the home or office. Automatic weekly backwash

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Gas Connector Installation Instructions

Fleck 2510 SXT Catalox Installation & Start Up Guide

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

SUPERIOR SOFT-TEC NO SALT WATER SOFTENER Installation & Operation Manual

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

WS1 Softener Installation & Start-Up Guide

RIVERSOFT Water Softener System

C Series Water Softener Installation & Operation Manual (Please save for future reference)

This product was manufactured in an ISO 9001:2000 certified facility.

5900e Neutralizer Installation & Start Up Guide

C Series Water Softeners Installation & Operation Manual (Please save for future reference)

Transcription:

Owners Manual The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration INLET OUTLET NRV Filter FOLLOWTHE INSTALLATION INSTRUCTIONS CAREFULLY. FAILURE TO INSTALL THE UNIT PROPERLY VOIDS THE WARRANTY. BEFORE YOU BEGIN INSTALLATION, READ THIS ENTIRE MANUAL. THEN, OBTAIN ALL THE MATERIALS AND TOOLS PLEASE NOTE: THE LIFE EXPECTANCY OF THE CARBON MEDIA BED IN THESE UNITS WILL BE REDUCED AS COMPARED TO A BACK WASHING STYLE CARBON FILTER. THE ACTUAL MEDIA BED LIFE WILL VARY DEPENDING ON WATER CONSUMPTION, CHLORINE/CHLORAMINES CONCENTRATION AND FLOW RATE. EXCEEDING THE PEAK FLOW RATE LISTED ON PAGE SIX WILL DRASTICALLY REDUCE THE LIFE EXPECTANCY OF THE CARBON MEDIA. 1. Read all instructions carefully before operation. 2. Avoid pinched o-rings during installaion by applying (provided with install kit) NSF certified lubricant to all seals. 3. This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfecion before or after the system.

Table of Contents UNPACKING / INSPECTION 4 SAFETY GUIDE 5 PROPER INSTALLATION 5 SYSTEM DIMENSIONS 5 SPECIFICATIONS 6 BEFORE STARTING INSTALLATION 6 INSTALL BYPASS TO THE FILTER 7 INSTALLATION INSTRUCTIONS 7 INSTALLATION 9 PARTS BREAKDOWN 10 TROUBLE SHOOTING 11 WARRANTY 12 3

UNPACKING / INSPECTION Be sure to check the entire unit for any shipping damage or parts loss. Also note damage to the shipping cartons. Contact the transportation company for all damage and loss claims. The manufacturer is not responsible for damages in transit. Small parts, needed to install the filter, are in a parts box. To avoid loss of the small parts, keep them in the parts bag until you are ready to use them. 1. Control Valve What is included in the box? 1. Control Valve 2. Tank 3. Parts Box 4. Owners Manual Bypass Shipped in Parts Box 3. Parts Box 2X 1 NPT Straight Adapter Bypass Tool 2X 900 3/4 Elbow Adapter Grease Packet 4

SAFETY GUIDE For your safety, the information in this manual must be followed to minimize the risk of electric shock, property damage or personal injury. s Check and comply with your provincial / state and local codes. You must follow these guidelines. s Use care when handling the filter tank. Do not turn upside down, drop, drag or set on sharp protrusions. s WARNING: This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. PROPER INSTALLATION This water filter system must be properly installed and located in accordance with the Installation Instructions before it is used. s DO NOT install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather. Water freezing in the system will break it. Do not attempt to treat water over 100 F. s DO NOT install in direct sunlight. Excessive sun or heat may cause distortion or other damage to non-metallic parts. s Properly ground to conform with all governing codes and ordinances. SYSTEM DIMENSIONS Models A (Inches) B (Inches) C (Inches) NRV TO-100 52 9" 12 NRV TO-150 58 10" 12 NRV TOK-100 52 9 12 NRV TOK-150 58 10 12 s Use only lead-free solder and flux for all sweat-solder connections, as required by state and federal codes. s Maximum allowable inlet water pressure is 125 psi. If daytime pressure is over 80 psi, night time pressure may exceed the maximum. Use a pressure reducing valve to reduce the flow if necessary. s WARNING: Discard all unused parts and packaging material after installation. Small parts remaining after the installation could be a choke hazard. C A NOTICE - THERE ARE INLET AND OUTLET LABELS ON THE VALVE. PLEASE MAKE SURE TO PLUMB AS SHOWN HERE B 5

SPECIFICATIONS How Your Filter Works These systems are complete, self-contained, loaded with media and ready to use. A simple inlet and outlet connecion is all that is required for installation. Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility. Specifications NRV TO-100 NRV TO-150 NRV TOK-100 NRV TOK-150 Peak Flow Rates 4.0 gpm 5.0 gpm 4.0 gpm 5.0 gpm Filter Media Volume - Cubic Feet 1.0 ft 1.5 ft 1.0 ft 1.5 ft Filter Tank Size 9x48 10x54 9x48 10x54 Media Type Coconut Carbon Coconut Carbon Coconut Carbon Coconut Carbon With KDF Distributor With KDF Distributor Media Loaded Yes Yes Yes Yes KDF Protector No No Yes Yes Tank Jacket No No No No Shipping Weight 60 lbs 78 lbs 60 lbs 78 lbs Plumbing Connections Includes 3/4 90 Elbows & 1 Straight NPT. Bypass Included. Electrical Requirements None Water Temperature Min 39 - Max. 100 degrees Fahrenheit Water Pressure Max. 125 psi BEFORE STARTING INSTALLATION Tools, Pipe, and Fittings, Other Materials These systems are complete, self-contained, loaded with media and ready to use. A simple inlet and outlet connection is all that is required for installation. Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility. s Pliers. s Screwdriver s Teflon tape s Razor knife s Two adjustable wrenches s Additional tools may be required if modification to home plumbing is required. s Plastic inlet and outlet fittings are included with the filter. To maintain full valve flow, 3/4 or 1 pipes to and from the filter fittings are recommended. You should maintain the same, or larger, pipe size as the water supply pipe, up to the filter inlet and outlet. s Use copper, brass, or PEX pipe and fittings. s Some codes may also allow PVC plastic pipe. s ALWAYS install the included bypass valve, or 3 shut-off valves. Bypass valves let you turn off water to the filter for repairs if needed, but still have water in the house pipes. 6

Where To Install The Filter s Place the filter tank as close as possible to the pressure tank (well system) or water meter (city water). s Connect the filter to the main water supply pipe BEFORE the water heater. DO NOT RUN HOT WATER THROUGH THE FILTER. Temperature of water passing through the filter must be less than 100 deg. F s Do not install the filter in a place where it could freeze. Damage caused by freezing is not covered by the warranty. INSTALL BYPASS TO THE FILTER s Put the filter in a place where water damage is least likely to occur if a leak develops. The manufacturer will not repair or pay for water damage. s If installing in an outside location, you must take the steps necessary to assure the filter, installation plumbing, wiring, etc., are as well protected from the elements, contamination, vandalism, etc., as when installed indoors. s Keep the filter out of direct sunlight. The sun s heat may soften and distort plastic parts. NOTE Be sure to use silicone grease on the O-rings (Provided) INSTALLATION INSTRUCTIONS 1. If your hot water tank is electric, turn off the power to it to avoid damage to the element in the tank. 2. If you have a private well, turn the power off to the pump and then shut off the main water shut off valve. If you have municipal water, simply shut off the main valve. Go to the faucet, (preferably on the lowest floor of the house) turn on the cold water until all pressure is relieved and the flow of water stops. 3. Connect the inlet and outlet of the filter using appropriate fittings. Perform all plumbing according to local plumbing codes. ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING WIRE BETWEEN THE INLET AND OUTLET PIPING TO MAINTAIN GROUNDING. The Inlet and Outlet should be as per below illustration. this will ensure that water will flow through the filter under upflow configuration Any solder joints near the valve must be done before connecting any piping to the valve. Always leave at least 6 (152 mm) between the valve and joints when soldering pipes that are connected to the valve. Failure to do this could cause damage to the valve. 4. Using the Allen Key (included), place the unit in the bypass position. Slowly turn on the main water supply. At the nearest cold treated water tap nearby remove the faucet screen, open the faucet and let water run a few minutes or until the system is free of any air or foreign material resulting from the plumbing work. The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration INLET OUTLET 7

5. Make sure there are no leaks in the plumbing system before proceeding. Close the water tap when water runs clean. 6. Proceed to start up instructions. Note: The unit is not ready for service until you complete the start-up instructions. Note : Carbon filters only: Once the unit has filled sufficiently that water is at least equal to the height of the media shut down the water for 15 20 minutes for the carbon to soak. After the carbon has soaked for the recommended time continue with installation instructions. Additional information for Non backwashing carbon filter. After soaking, remove the aerator screen from the nearest faucet, run water at this faucet until all fines (black) is gone from the water. Care of Your System To retain the attractive appearance of your new water filter, clean occasionally with mild soap solution. Do not use abrasive cleaners, ammonia or solvents. Never subject your filter to freezing or to temperatures above 100 F. Replacing the Media Bed Carbon NRV Filter - under normal operating conditions the effective life of the filter media is approximately one to three years, depending on the water quality, after which, taste and odor problems may return. When this happens, contact your dealer for a replacement media bed. Check to ensure all media parts are received. The first step in replacing the media bed is to shut off the water supply to the filter. At this point, you must disconnect the plumbing from the inlet and outlet. Then unscrew the head from the fibreglass tank. Once this has been done, remove the distributor tube. Then you can remove the filter media and two types of gravel from the tank. The quickest way to do this is by simply tipping the tank upside down into a large drum or pail. Loading the Media Pak Place the distributor tube back down the center of the tank. NOTE: the top of this tube should be plugged with a rag or cork to prevent media from entering. Pour the bag of coarse gravel into the tank, and then pour the bag of fine gravel into the tank. It is important that the distributor tube is not moved or pulled out as it is not possible to put it down to the bottom of the tank once gravel or media are in the tank. a a b c Plug the Riser Tube The riser (distributor) remains inside the tank seated in the depression at the bottom a) Remove the adaptor from the mineral tank. Grease the bottom oring of the adaptor. 8 b) Temporarily plug the open end of the riser tube to ensure that no resin or gravel falls down into the distribution. The riser (distributor) remains inside the tank seated in the depression at the bottom. Plug tube with a tape. Remove after media is loaded. c) Fill support bed first. The media will not always spill down inside the tank and may need to be swept inside. The large funnel (sold separately makes filling the tank easier and neater. (Or an empty 1 gallon or 4 liter container with the bottom cut out makes a good funnel.)

INSTALLATION Electrical Panel Ground Strap Ground Strap Cold Soft Water Hot Soft Water Raw Water Filtered Water Drain Water Meter NRV Filter Softener Water Heater 9

PARTS BREAKDOWN Bypass - 60095097 Model Mineral Tank Size Tank # (Natural Color) Tank # (Black Color) Tank # (Blue Color) Distributor# Valve # Media Bed # NRV-100 9 x 48 25010034 25010036 25010035 50010005 95402 60010068 NRV-150 10 x 54 25010049 25010051 25010050 50010005 95403 NRV-100TOK 9 x 48 25010034 25010036 25010035 50010012 95402 60010068 NRV-150TOK 10 x 54 25010049 25010051 25010050 50010012 95403 Bypass parts list No. Part # (WaterGroup) Description 24 60010006 Bypass Tool 1 23 NOT SOLD 063 Bypass Body 1 22 60010026 O-ring( 22.4 3.55) 2 21 60010020 Connector 3/4 NPT 2 20 60095087 Connector Clip 2 19 60095088 Bypass Shaft( Outlet) 1 18 60095089 Bypass Shaft( Inlet) 1 17 60095614 O-ring(30 2.65) 2 16 60095051 Shaft Seal 2 15 92846 Plug Clip 2 14 60095090 Shaft Clip 2 13 60010209 Bypass Plug 2 12 60010044 O-ring(12 2) 2 11 60010126 Screw M4 12 2 10 60010046 SS Clip 2 9 60095054 Bush 2 8 Qty Impeller Pin 1 10 7 60010238 Magnet 2 6 Impeller 1 5 60010102 O-ring(27 3) 1 4 60010587 Impeller Support 1 3 60010079 Valve-Bypass Connector(Inlet) 1 2 60010101 Valve-Bypass Connector(Outlet) 1 1 60010562 O-ring(23 3) 3

TROUBLE SHOOTING A. FILTER BLEEDS TASTE AND ODOR OR SEDIMENT 1. By-pass valve open. Close by-pass valve. 2. Defective or stripped media bed Replace media 3. Quality of water has worsened Have water sample analyzed to determine any change 4. Filter capacity too small Replace with larger unit or add another filter 5. Leak between valve and central tube. Check if central tube is cracked or o-ring is damaged. Replace faulty parts. B. LOW WATER PRESSURE 1. Iron or scale build up in line feeding unit. Clean pipes. 2. Inlet of control plugged due to foreign material. Clean control valve. 11

WARRANTY Canature WaterGroup warrants that your new water conditioner is built of quality material and workmanship. When properly installed and maintained, it will give years of trouble free service. Five Year Complete Parts Warranty Canature WaterGroup will replace any part which fails within 60 months from date of manufacture, as indicated by the serial number, provided the failure is due to a defect in material or workmanship. The only exception shall be when proof of purchase or installation is provided and then the warranty period shall be from the date thereof. Ten Year Warranty on Mineral Tanks and Brine Tanks Canature WaterGroup will provide a replacement mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails within 120 months, provided that the water conditioner is at all times operated in accordance with specifications and not subject to freezing. General Provisions Damage to any part of this water conditioner or filter as a result of misuse, misapplication, neglect, alteration, accident, installation or operation contrary to our printed instructions, damage to ion exchange resin and seals caused by chlorine / chloramines in the water supply, or damage caused by any force of nature is not covered in this warranty. We will repair or replace defective parts if our warranty department determines it to be defective under the terms of this warranty. Canature WaterGroup assumes no responsibility for consequential damage, labor or expense incurred as a result of a defect or failure. In the U.S.A. 1-877-288-9888 In Canada 1-877-288-9888 Regina, SK Cambridge, ON Carmel, IN Fridley, MN Phoenix, AZ Pottstown, PA 54540 01/18