Strategies for Building Energy Efficiency

Similar documents
August 15, 2013 Page 1 of 19

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

Energy-Efficiency Measures List

Facility information. Building Envelope

COMMERCIAL ENERGY SAVINGS GUIDE

ASHRAE/IESNA Standard

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

Incentive & Measure Specifications

Sequence of Operations (excerpt)

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

Thaddeus Stevens College of Technology Mellor Building

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Appendix A. Glossary of Common Terms

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

HVAC Mandatory Provisions Part II, Page 1

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

InvestSmart Business Energy Upgrades Lighting Equipment Catalog 01/01/2018

Job Name Control Systems Description Date

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

IMPA Energy Efficiency Program

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

COMcheck Software Version Review Mechanical Compliance Certificate

ONTARIO BUILDING CODE AND SUPPLEMENTARY STANDARD SB-10 PROJECT INFORMATION. Mechanical Designer Information*

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

CHAPTER 4. HVAC DELIVERY SYSTEMS

Energy Conservation Measures For the Town of Lakeville. Locations Town Hall Fire Department Police Department Council on Aging

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

High Performance Building Guide 1

2009 IECC Commercial Mechanical Requirements

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Paul McCown, PE, CEM, LEED AP, CxA Sr. Mechanical Engineer SSRCx, LLC Nashville, TN USA

2018 Rebate Catalog and Application

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

ENERGY AUDITOR CHECKLIST **

EarthWise System Seminar

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

1 - This title will copy onto other forms Date

Direct Install Program Eligible Measures Listing:

b.) Technical Information:

Business Energy Efficiency Incentives 2007

Energy Management and Controls

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Low-Impact Remodeling

A Guide to the Commercial Building Tax Deduction. Effective: January 1, 2006 to December 31, 2008 HL /07

HVAC Controls Upgrades: Requirement Details ( )

Residential Energy Efficiency Measures

Appendix 13. Categories of Cooling and Heating systems

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Energy Efficiency Practices for the Low- Income Population

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

Prescriptions for Critical Healthcare Cx. John D. Villani, P.E. Associate Grumman/Butkus Associates

Lackland ISD Energy Conservation Plan

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

Summary Comparison of Simulation Program Features

HVAC Controls Upgrades: Requirement Details ( )

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

HVAC System Consideration$ 05/14/2012 SAVING MONEY IN HVAC SYSTEMS

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

SEISCO APPLICATIONS & DIAGRAMS

Continuous Commissioning: A Valuable Partner to Retrofit Projects

An HVAC Audit of the Canberra Institute of Technology

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Efficiency: The Ultimate Renewable Resource

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

COMcheck Software Version Mechanical Compliance Certificate

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

Architectural Engineering Senior Thesis Mechanical System Redesign

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

CARNEGIE-STOUT PUBLIC LIBRARY REQUEST FOR PROPOSALS FOR HVAC MAINTENANCE

COMcheck Software Version Interior Lighting Compliance Certificate

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Summary of Energy Program Incentives

Eligible Prescriptive Measures List:

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

2018 International Energy Conservation Code (IECC) Updates

COMcheck Software Version Interior Lighting Compliance Certificate

High Five for Saving Energy!

HVAC 101. H V A C S y s t e m s

ASHRAE JOURNAL ON REHEAT

CONTENTS. B. System Design and Performance Requirements

9/18/2017. Nicholas Thornton, CEM. Systems: HVAC, Electrical, and Technology. Overview. Today s Goals Introductions HVAC Electrical Technology Q&A

MUNICIPAL ICE RINK PROGRAM

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

IAQ: Re-tuning Commercial Buildings

TECHNICAL REPORT 3 Mechanical Systems and Existing Conditions Northfield Mental Healthcare Center Northfield, Ohio

Urbana Free Library HVAC Analysis. Prepared for the Urbana Free Library. Prepared by Paul Boland, P.E., and Nathan Alderman, E.I.T.

BUILDING DESIGN STANDARDS. AIR CONDITIONING DIVISION 23 Heating, Ventilation and Air Conditioning

101 EASY WAYS TO SAVE ENERGY AND MONEY.

Small Building Program Design Phase Assistance

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

Reducing Energy in Heating, Cooling and Lighting

InterNACHI Home Energy Inspection for th Street

Transcription:

Strategies for Building Energy Efficiency Ben Sliwinski Technical Director SEDAC University of Illinois at Urbana-Champaign

How Buildings Use Energy Building Envelope (Walls, Roof, Windows, Floors) Lighting Heating, Ventilating, and Air Conditioning (HVAC) Internal and Process Loads (cooking, hot water, swimming pools, manufacturing, etc.)

Envelope

Increase Wall and Roof Insulation Insulate Walls to at least R-13 Insulate Roofs to at least R-20, Attics to R- 38. Floors over unconditioned spaces to R-30. Highly Efficient Buildings will have values which exceed these.

Window Characteristics Five key parameters: U-Factor Solar Heat Gain Coefficient (SHGC) Visual Light Transmittance (VLT) Air Leakage (cfm/sf) Condensation Resistance www.nfrc.org

The magic of Low-E The E stands for emissivity Absorptivity and Emissivity describe how materials respond to radiation. The properties are wavelength dependent. This allows a material to transmit light but block heat.

Why Low-E works

Tailoring the Window Lower U values almost always the best choice. Solar Heat Gain Coefficient can be selected to block less heat in Northern Climates more in Southern. VLT can be chosen to maximize daylighting or to eliminate glare.

Some Window Rules-of-Thumb U-Value Cold Climate Mixed Climate Hot Climate <0.33 all climates: low U not quite as important in hot climates VT >60% >50% >50% SHGC >0.55 0.40-0.55 <0.40 Spacer warm-edge spacers for all climates Frame Thermally broken frames for all climates Air Leakage <0.30 cfm/sf for all climates

Insulating Window Shades High R-Value Window Shades, while expensive, may also be a viable option.

Interior Window Films If acceptable by building management, window films may be a useful option. Choose film tailored for climate.

Air Sealing Air Sealing is just as important in a commercial or municipal building as it is in your home maybe even more! Wind and Stack effects are greater In multi story construction.

Lighting

Compact Fluorescent

Super T8 and Low Wattage T8 Super T8 systems can produce energy savings as high as 40 percent over standard T8. To identify a Super T8, look for lamps that are at least 3100 initial lumens [as opposed to 2850 for a standard T8] and have a barrier coat design and high lumen maintenance. Super T8 lamps include the SYLVANIA "Xtreme," Philips "Advantage" and GE "HL." Ballasts include the SYLVANIA "Xtreme," Advance "Optanium," Universal Triad "HE" and GE "UltraMax.

Occupancy Sensors Use them for office lighting Restroom lighting Storage Areas Mechanical Rooms Warehouse Aisles - Fluorescent Get creative use for HVAC in individual rooms or zones.

Isole Personal Occupancy Sensor

LED Exit Signs Payback is quick Rebates available Very basic lighting energy savings measure Chicago approved

HID to Fluorescent Retrofit Existing System: 400watt High Pressure Sodium and 400watt Metal Halide. Each fixture uses 455 watts (400 for lamp, 55 for ballast) Retrofit Each fixture uses 234 watts (lamps and ballast combined) Light levels increased 10-20%

Street and Parking Lot Lighting Probe Start HID to Pulse Start HID a typical retrofit. Fluorescent Induction, and LEDs making moves into market

Probe vs. Pulse Start

LED Traffic Signals Application is very popular Energy savings 50 to 75 percent Good LED application: directed light and switched on and off

LED Street Lighting DOE I-35 Minneapolis Gateway Study The LED luminaires offered a conservative 13% energy savings relative to the baseline HPS system. Simple payback was found to be quite long at current luminaire pricing. Overall public reaction to the LED bridge lighting has been very positive, with positive comments outweighing negative comments by about five-toone.

Other DOE Gateway Results http://www1.eere.energy.gov/buildings/ssl/ Oakland Street lighting 15 year payback Supermarket Parking Lot 70 percent savings 5 year payback

HVAC

Programmable Thermostats They work when you use them.

Thermostat Set-Back and Set-Up Set Heating to 68 F, set-back to at least 60 during unoccupied periods. Let condensation be your guide. Set cooling to 74, set-up to 80 during unoccupied periods. Developing morning recovery schedule based on demand charges or system capacity. Easy to do on systems without reheat.

System Shutdown During Breaks HVAC turn off exhaust fans HVAC place air handling units in unoccupied or holiday schedule HVAC place temperature control into unoccupied mode setbacks Lighting turn off sections, and go to minimum levels if bi-level switching available Plug loads turn off as possible

Variable Frequency Drives Variable Frequency Drives can save 20 percent or more in electrical usage. Often there are additional benefits in process control and quality. Look for pump and fan systems which have bypass or valve control. Chilled Water, Hot Water, AHU Fans, Pool Sand Filter Pumps are typical applications.

Demand Control Ventilation

Unit Ventilators great opportunities to save

CO 2 and Occupancy Sensor Control for Unit Ventilators

VAV Supply Air Temp. Reset Saves cooling energy Saves reheat energy Increases hours when economizer can be utilized.

VAV Fans Static Pressure Reset on VAV Systems. Provides significant fan energy savings since system is often at part load Reduces fan noise

VAV Control Deadband Variable air volume (VAV ) terminal units shall be programmed to operate at the minimum airflow setting without addition of reheat when the zone temperature is within the set deadband. To meet this requirement, the control system must allow separate heating and cooling setpoints that are at least 5 F apart. If, for example,the cooling setpoint is 75 F, then the control system cannot enable the reheat coil until the space temperature drops to 70 F or below.

Radiator Valves For spaces that tend to overheat, and don t have thermostats for control of radiators or hot water convectors.

Boilers, Chiller, Etc. Don t start boilers until OA temperatures are below 50 consistently. Consider shutting down boilers used for AC reheat in the summer or resetting the supply water temperature. Shut down chillers when OA temperatures are consistently below 50, and use economizer.

Reset Boiler Water and Chilled Water Supply Temps. Lower boiler water supply temperature in mild weather. Raise chilled water supply temperature in mild or dry weather.

Use Modular Boilers Modular boilers can follow load more closely with greatly improved efficiency Can mix modular boilers with existing large boiler system.

Isolate Off-Line Chillers Depending on plant arrangement and offline chiller can act as a bypass between supply and return water. This reduces system delta T, and wastes pumping energy.

Try Refrigerant Migration Free Cooling Some centrifugal chillers can provide free cooling at reduced capacity during periods when low temperature condenser water is available.

Reduce Boiler Blowdown Rate Review your blowdown practices to identify energy saving opportunities. Examine operating practices for boiler feedwater and blowdown rates developed by the American Society of Mechanical Engineers (ASME). Considerations include operating pressure, steam purity, and deposition control. Consider an automatic blowdown control system Fact Sheet Available at http://www1.eere.energy.gov/industry/bestpractices/p dfs/steam9_blowdown.pdf

Computers and Office Equipment

Vending Energy Management Vending Misers can be used to control Snack and Cold Drink Machines

Water Savings Measures Faucet Aerators Low Flow Shower Heads Low Flow Water Closets Low Flow Urinals Reduced cooling loads reduce cooling tower water usage Eliminate once-through cooling systems where possible

Water Saving Fixture Data Fixture Type EPAct 1992 Usage Limit Water Efficient Fixture Water Closet 1.6 GPF 1.1 to 0.8 GPF Urinal 1.0 GPF 0.5 to 0.0 GPF Faucet 2.5 GPM 1.8 GPM Shower 2.5 GPM 1.8 GPM

Lower Water Heater Temperature Set domestic water heater temperature to 130 F. Use gas fired booster heater where higher temp is required.

Retro-Commissioning

Typical Findings from RCx Missing or broken equipment/components Incorrect thermostat settings and control sequences Incorrect or missing BAS schedules for fans, pumps, lights, and other key components Malfunctioning control sensors such as outside air temperature sensors, supply air temperature sensors, damper position, etc. Heating and cooling systems fighting each other (excessive reheat).

Excessive Reheat Summer

Incorrect Schedule Fan System 2A 2B ERF2 A ERF2 B 3A 3B 5A 5B 7A 7B 8A 8B Monday Tuesday Wednesday Thursday Friday Saturday Sunday Start On 6:00 On 6:00 On 5:45 On 5:30 On 5:45 On 6:03 Stop On 9:45 On 9:45 On 9:45 On 9:20 On 9:45 On 9:41 Start On 6:00 On 6:00 On 5:45 On 5:30 On 5:45 On 6:03 Stop On 9:45 On 9:45 On 9:45 On 9:20 On 9:45 On 9:41 Start On 6:00 On 6:00 On 5:45 On 5:30 On 5:45 On 6:03 Stop On 9:45 On 9:45 On 9:45 On 9:20 On 9:45 On 9:41 Start On 6:00 On 6:00 On 5:45 On 5:30 On 5:45 On 6:03 Stop On 9:45 On 9:45 On 9:45 On 9:20 On 9:45 On 9:41 Start On 6:00 On 6:00 On 5:45 On 5:30 On 5:45 On 6:03 Stop On 9:45 On 9:45 On 9:45 On 9:20 On 9:45 On 9:41 Start On 8:45 On 8:45 On 8:30 On 8:10 On 8:30 On 8:43 Stop On 5:45 On 5:45 On 5:45 On 5:20 On 5:45 On 5:41 Start On 12:45 On 12:45 On 12:30 On 12:10 On 12:30 On 12:43 Stop On 5:45 On 5:45 On 5:45 On 5:20 On 5:45 On 5:41

Incorrect Control Sequence

Opportunity for Tighter Demand Control

Control of Baseboard Heaters

To Apply for SEDAC Assistance Call 1-800-214-7954 or, Visit the SEDAC web site at www.sedac.org and download an application.