in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Similar documents
HTM Circulation Pumps acc. to DIN EN 733 Type NKX

Global-Tek (Singapore) Pte Ltd

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Service Manual Tumble Dryer Air Vent

MODEL UC50e PARTS MANUAL Rev 1.00B

Silhouette. Feedwater Heater. Boiler Feedwater

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

MODEL UC50e PARTS MANUAL Rev 1.02

TA-MATIC

AD-236 AD-330. AD-360x2 AD-4545

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

General Description. Operation

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Transformer oil coolers BETA & CETA

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Flow Measurement SITRANS F C

GAS COMPONENTS ELECTRIC COMPONENTS WATER TECHNOLOGY MECHANICAL COMPONENTS TOOLS. Spare parts suitable for LA CIMBALI

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

MODEL CMA-130VL PARTS MANUAL Rev 1.00

Technology for life. Unit heater LH

Raffaello From serial number Group

VANGUARD 245 POST-MIX DISPENSER

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

CASSETTE UNIT. Comfort Circle

Thermostatic expansion valves for ammonia Type TEA

Safety vacuum drying oven for flammable solvents

Service Manual Tumble dryer Air Vent Electronic

SPARE PARTS LIST TPC A P - TPC VA P

PARTS MANUAL Rev 1.00B DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA FAX

/13 Price - $5.00

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

WOLF VENTILATION SYSTEM PRICE LIST

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

INSTALLATION and OPERATION INSTRUCTIONS

Heated Gas Sampling Probe PSG Basic

Tetra Pak Rotary Moulder 35 A2 Moulded stick novelty freezer

Precision air handling cabinets Ciatronic MICRO/EXPAIR

High Heat COP. High/Low Stage

1. General Description

Spare Parts Catalogue RC411

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

TECHNICAL SPECIFICATIONS

MITSUBISHI AIR-CON SPARES TD43C/TD43D/TD60

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

MD-170 Installation/Operator's Manual

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

NEW GREEN TECHNOLOGY

STC Series Twin Unit Coolers (E329630_A)

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

NEPTUNE 1. Model: NEPTUNE Part List English

PARTS MANUAL. American Dish Service ADS HIGH TEMP SINGLE RACK DISHMACHINE MODEL: HT Blake Street Edwardsville, Kansas (913)

Environmental Chambers

Thermostatic Expansion Valves Type TR 6

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Cool IR. Model C104 - Cooling System. Instruction Manual

DDM SERIES. Desiccant Dryer Mobile Drying of free-flowing granular plastic materials

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Model 10AB/APRB Automatic Dishwasher

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

(2) 325 tpd York Chlorine Liquefier Systems

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Replacement Parts List For Models COS-101 COS-101S

St George Appliances Spare Parts List MODEL FED4AS June 2003

GALATEA DOMUS. Dal 1901 COD

CATALOG OF REPLACEMENT PARTS

STR-600 Impact Dryer

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

CR20-07 A-F-A-E-HQQE 3x400/ HZ

STEAM TRAPS

Storage tank size Rated volume [l] Actual volume [l]

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

ThermoDual Domestic hot water charging system

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

2 - Hood DESCRIPTION CABLE HOLDER FOR BHC SLIDING WASHER TIE ROD FC SLIDING PLATE F. TIE ROD DOOR CATCH BR-BC-FC DOOR CATCH B-F-R

CATALOG OF REPLACEMENT PARTS

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

CR1 Series Triton Corrosion Resistant Washdown Heaters

AD-410 Models AD-410 NON-TILT* 1 DOOR GAS MODEL AD-410 NON-TILT* 1 DOOR STEAM MODEL

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Taco 00 Series Cartridge Circulators

TECHNICAL INFORMATION L / A 1

Air Cooled Oil Coolers

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

Transcription:

CO 2 Vaporising Atmospheric ASCO CO 2 Vaporiser The atmospheric ASCO CO 2 Vaporiser has been developed to drastically reduce CO 2 vaporisation costs. Ambient air, which is available at no cost, is used to achieve energy savings of over 95 % compared to standard electric vaporisers. As each vaporiser is supplied prepiped and prewired, installation can be made within minutes. Bases for the mounting on the floor are included in the delivery. In addition to our standard models, we offers individual solutions of modern and easy to maintain CO 2 vaporisers. In accordance with your requirements, we provide you with a suitable CO 2 vaporiser. Advantages of an atmospheric ASCO CO 2 vaporiser: 25 times less energy compared with electrically heated vaporisers Designed for continuous and automatic operation (no attendance required) Built-in thermostat to prevent liquid CO 2 from flowing through 2 coil system to ensure safe defrosting with built in solenoid valves Simple and fast installation, only electric power and CO 2 required Vaporisers with tubes in stainless steel or copper available Complete unit in various capacities at very reasonable prices, ready for use Specifications Vaporising capacity (approx.) from liquid CO 2 at 17 bar (247 psi) length/width/height mm incl. control box in/out connections outer Ø net weight kg approx. power consumption max. operating pressure 200 kg/h CU (440 lb/h) 2 200 900 1'000 (87 x 35 x 39 in) 1 PN 40 126 kg (278 lb/h) 1.58 kw (2.12 HP) 200 kg/h SS (440 lb/h) 2 200 900 1'000 (87 x 35 x 39 in) 1 PN 40 126 kg (278 lb/h) 1.58 kw (2.12 HP) 300 kg/h CU (661 lb/h) 3 000 900 1'000 (118 x 35 x 39 in) 1 PN 40 260 kg (573 lb/h) 300 kg/h SS (661 lb) 3 000 900 1'000 (118 x 35 x 39 in) 1 PN 40 260 kg (573 lb/h) 500 kg/h CU (1102 lb/h) 3 000 900 1'200 (118 x 35 x 39 in) 1 PN 40 320 kg (705 lb/h) 500 kg/h SS (1102 lb/h) 3 000 900 1'200 (87 x 35 x 47 in) 1 PN 40 320 kg (705 lb/h) 1 000 kg/h CU (2205 lb/h) 4 200 1'000 1 450 (165 x 39 x 57 in) 1 PN 40 510 kg (1124 lb/h) 5.37 kw (7.20 HP) 1 000 kg/h SS (2205 lb/h) 4 200 1'000 1 450 (165 x 39 x 57 in) 1 PN 40 510 kg (1124 lb/h) 5.37 kw (7.20 HP) CU = with copper tubes, SS = with stainless steel tubes Ambient air temperature: min. +10 C, max. +45 C

Atmospheric ASCO CO 2 Vaporisers: Description CO 2 gas to bottling line or other point of use Pressure reducing valve CO 2 storage tank CO 2 vaporiser Temperature sensor with automatic shut-off Liquid carbon dioxide is taken from a tank, completely evaporated in the vaporiser and fed to the point of use. In order to ensure safe defrosting of the vaporiser, it is equipped with two autonomous coils, which are controlled by a solenoid valve each. While one vaporiser coil is in service, the other is being defrosted. The air blowers remain in continuous operation. The arrangement shown above permits operation of the vaporiser at air temperatures of max. +45 C, at least +10 C and, at reduced capacity as low as +5 C in order to be able to utilise the vaporiser thoughout the year, the unit should be installed inside a building away from the most inclement weather, for example in a boiler room or similar. Liquid CO 2 in Fans Thermostat with automatic shut-off CO 2 gas out Time switch Solenoid valves Air

Atmospheric ASCO CO 2 Vaporisers: Description and installation Description ASCO Atmospheric CO 2 Vaporisers are supplied as one unit, prewired, pretested (incl. pressure test to 35.4 bar) (513.43 psi) and ready for immediate use. They consist of a special heat exchanger unit and aluminium fins. Air is forced through the heat exchanger by fans. Any condensate dropping from the tubes is collected by an aluminium tray mounted on the bottom of the unit, and an outlet pipe can be connected to drain. The unit also includes solenoid valves and a complete control box. A temperature sensor is also incorporated to ensure no liquid CO 2 can pass through the vaporiser. Installation ASCO Vaporisers should ideally be installed in areas such as boiler houses and similar warm rooms (max. temperature of +45 C). External installation is only recommended where ambient air temperature is above +10 C and max. +45 C. They also operate at +5 C but at reduced capacity. 1'000 kg/h (2'204.62 lb/h) atmospheric ASCO CO 2 Vaporiser: Thermostat 1'000 kg/h (2'204.62 lb/h) Atmospheric ASCO CO 2 Vaporiser: Control box with timer 1'000 kg/h (2'204.62 lb/h) Atmospheric ASCO CO 2 Vaporiser: Air intake side 1'000 kg/h ('2204.62 lb/h) Atmospheric ASCO CO 2 Vaporiser: Two independent coils

Atmospheric ASCO CO 2 Vaporiser: Available standard capacities Pos. 001 200 kg/h (440.92 lb) atmospheric ASCO CO 2 Vaporiser CU part no. 4046048 SS part no. 4062852 air flow total: 3.4 m 3 /sec (120 ft 3 /sec) coil volume: 15 l (4 gal) net weight: approx. 126 kg (277.78 lb) fan speed: 1 330 rpm no. of fans: 2 power cons. per fan: 0.79 kw (1.06 HP) SS = stainless steel Pos. 002 300 kg/h (661.39 lb/h) atmospheric ASCO CO 2 Vaporiser CU part no. 4062853 SS part no. 4062854 air flow total: 5.1 m 3 /sec (180.1 ft 3 /sec) coil volume: 22 l (5.8 gal) net weight: approx. 260 kg (573.20 lb) fan speed: 1 330 rpm no. of fans: 3 power cons. per fan: 0.79 kw (1.06 HP) SS = stainless steel Pos. 003 500 kg/h (1'102.31 lb) atmospheric ASCO CO 2 Vaporiser CU part no. 4062855 SS part no. 4062856 air flow total: 5.1 m 3 /sec (180.1 ft 3 /sec) coil volume: 41 l (10.8 gal) net weight: approx. 320 kg (705.48 lb) fan speed: 1 330 rpm no. of fans: 3 power cons. per fan: 0.79 kw (1.06 HP) SS = stainless steel'

Atmospheric ASCO CO 2 Vaporiser: Available standard capacities Pos. 004 1 000 kg/h (2204.62 lb/h) atmospheric ASCO CO 2 Vaporiser CU part no. 4046061 SS part no. 4062858 air flow total: 9.9 m 3 /sec (349.6 ft 3 /sec) coil volume: 78 l (20.6 gal) net weight: approx. 510 kg (1'124.36 lb) fan speed: 890 rpm no. of fans: 3 power cons. per fan: 1.79 kw (2.40 HP) SS = stainless steel Atmospheric CO 2 Vaporisers: Options Pos. 001 Dome loaded pressure reducing valve C31 part no. 4046817 for gaseous and liquid CO 2 incl. repair kit (diaphagm and O-ring) Pos. 002 Dome loaded pressure reducing valve C2-K32 part no. 4046644 for gaseous and liquid CO 2 incl. repair kit (diaphagm and O-ring) Pos. 003 Line safety assembly 1 - (362.59 psi) welding connection Consisting of: stainless steel pipe 1 300 mm (11.81 in) safety valve (362.59 psi) vent ball valve stainless steel 1/4 part no. 4046831

Atmospheric CO 2 Vaporisers: Options Pos. 004 CO 2 flowmeter MF15 Mass flow sensor Type MF15 (fully calibrated) assembled to process pipe DN 15, PN 40 with flange connection DIN 2635. Measuring range 0-1 000 kg/h ( 0-2205 lb/h) at 22 bar (319.08 psi) The flow computer (on wall bracket) is equipped with digital display of current CO 2 flow rate in kg/h as well as totalizer and integrated keyboard. 10 meter connection cable with plug is prewired and connected. Voltage 115-230 V, 50/60 Hz part no. 4062504 Accessories included: 2 pcs counterflange DN 15/PN40 welding (item no. 910101) 8 pcs screw m12x45, hex., inox (item no. 100020) 8 pcs nut M12, inox (item no. 100022) 2 pcs gasket DN15, 2 x 51 x 22 mm ( (item no. 110150) Pos. 005 CO 2 flowmeter MF25 Mass flow sensor Type MF25 (fully calibrated) assembled to process pipe DN 25, PN 40 with flange connection DIN 2635. Measuring range 0-2 700 kg/h (0-5'952 lb/h) at 22 bar (319.08 psi) The flow computer (on wall bracket) is equipped with digital display of current CO 2 flow rat in kg/h as well as totalizer and integrated keyboard. 10 meter connection cable with plug is prewired and connected. Voltage 115-230 V, 50/60 Hz part no. 4062505 Accessories included: 2 pcs counterflange DN 25/PN40 welding (item no. 910301) 8 pcs screw M12x45, hex., inox (item no. 100020) 8 pcs Nut M12, inox (item no. 100022) 2 pcs gasket DN25, 2 x 71 x 35 mm (0.08 x 2.80 x 1.38 in) (item no. 110151)