Aspirated Smoke Detectors

Similar documents
Aspirating smoke detection

HART XL High Sensitivity Smoke Detection

Retail security solutions

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

HART XL High Sensitivity Smoke Detection

Open-area Smoke Imaging Detection (OSID)

FAAST PRODUCT RANGE Aspirating Smoke Detection

Intelligent Earliest Warning Aspirating Fire Detector

Aspir A ation spir P R O D U C T S

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

FAAST Beyond Standard Methods of Detection

EARLIEST SMOKE DETECTION WITH MAXIMUM FLEXIBILITY

FAAST. Fire Alarm Aspirating Sensing Technology

Buys Time. Aspirating Smoke Detection

ID50series. intelligent fire alarm panels

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

LM80031 Issue H. Installer s Handbook

Open-area Smoke Imaging Detection (OSID)

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

FAAST. Fire Alarm Aspirating Sensing Technology

Why Hart XL Aspirating Smoke Detection?

Analogue Detectors. Series 200 plus

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Open-area Smoke Imaging Detection (OSID)

TrueAlarm Analog Sensing

High-precision aspirating smoke detectors for every requirement.

LaserFOCUS VLF-250 Engineering Specification

The World's No. 1 Brand of Air-sampling Smoke Detector

Buys Time. Aspirating Smoke Detection

FAAST. Fire Alarm Aspiration Sensing Technology

Aspiration Detection.

High Sensitivity Smoke Detector

Flexible Air-sampling Smoke Detection

Aspirating Smoke Detection (ASD) Systems Fire Detection

LEARNING SPECIAL HAZARD DETECTION TYPES

TrueAlarm Smoke Detectors

intelligent fire alarm ID60series panels

FIRElink-25 Air Sampling System INSTALLATION MANUAL

Consultant Specification AGILE Wireless Fire Detection System

FIRElink-100 Air Sampling System INSTALLATION MANUAL

Desigo Fire Safety intelligent detectors for complete safety

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

LaserSense HSSD-2 Aspirating Smoke Detector Installers Handbook

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

CAPILLARY SAMPLING INTRODUCTION. Page 1 CAPILLARY SAMPLING

Leading by technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Intelligent. Signature Series Multisensor Detection. An EDWARDS brand.

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

High Sensitivity Smoke Detector

The World s No. 1 Brand of Aspirating Smoke Detection

Evolution Analogue Addressable Fire System

Aspirating Smoke Detection

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Laser Technology Smoke Detector

Motion sensor technologies. Leading by technology

and Aspirating Smoke Detection

High Sensitivity Smoke Detector

LaserSense 10 Aspirating Smoke Detector Installers Handbook

Turning expertise and innovations into marine solutions

High Sensitivity Smoke Detector

PROPOINT PLUS ASPIRATING SMOKE DETECTION SYSTEM

The World's No. 1 Brand of Aspirating Smoke Detector

Intelligent Signature Series Analog Detection

Range brochure. Beam detection. others look up to.

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

PoleStar Smart Refrigerated Air Dryers don t just cycle, cycle Smart.

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

The Digital Scroll Dryer

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Flexible & Innovative. Cooling Solutions

INTREPID Perimeter Intrusion Detection System

VESDA ASPIRATING SMOKE DETECTION INDUSTRY GUIDE SUBSTATIONS

Air Preparation Systems PRD Series

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

The World's No. 1 Brand of Aspirating Smoke Detector

Complete solutions for commercial security. Verex delivers leading intrusion, access and video products to protect today s companies

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Multi-Point Peripherals

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

ALK-V PHOTOELECTRIC SMOKE SENSOR

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

Introducing the innovative ipids Indoor Outdoor Detection System MANUFACTURING SECURITY SOLUTIONS

Energy Saving Refrigerated Air Dryers SRC Cycling Dryers

Australasia OVERVIEW, SIZE AND SCOPE ORGANISATIONAL STRUCTURE

Different types of Fire Alarm System

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Fact File 66. Guide to Beam Smoke Detectors

Cerberus FIT conventional system

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

SPEED, STABILITY, & RELIABILITY N EW! IntelliQuad TM PLUS Combination Smoke and Carbon Monoxide (CO) Detector

ID2000. intelligent fire alarm panel

Water-cooled chillers with High Speed Centrifugal Compressors

Aspirating Systems Design and Application Guide

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

Transcription:

Safety Security Certainty LaserSense Aspirated Smoke Detectors We listened to you

Aspirated air sampling technology Aspirated smoke detection is a method of smoke detection where the air from the protected area is actively drawn through a network of air sampling pipes, passed through a central detection unit and sampled for the presence of smoke. Based on the forward light scatter principle, the unit directs a powerful semiconductor laser through an aperture in a specially designed reflector. Any combustion products present in the moving air sample scatter light on the reflector from where it is focused on a single photo receiver. Aspirated Smoke Detection While perfectly clean air produces a very small amount of scatter, as the volume of particles below a specific size increases, the amount of light scatter increases. Measuring the amount of scatter gives a measure of the volume of impurity in the air - which in itself is directly related to the size of the fire. Relative to other methods, forward scatter laser technology has the advantage of significantly earlier detection. Other advantages include inherent immunity to dust/dirt build up, high signal to noise level and resistance to problems caused by vibration and high humidity. The signal from the detection chamber is processed by a unique ClassiFire Perceptive Artificial Intelligence system which continually adjusts the detector sensitivity to maintain a consistent level of performance. The detector s wastegate system samples a fraction of the air while bypassing the rest, thereby maximizing service life and permitting operation in diverse environments.

LaserSense Technology LaserSense is a highly sophisticated High Sensitivity Aspirated Smoke Detection product that has been designed to ensure that installation and commissioning is as simple as possible, while optimizing performance. The LaserSense range of detectors incorporates a patented artificial intelligence known as ClassiFire, which allows the detector to continually optimize its sensitivity ensuring a consistent level of protection in virtually any environment with minimal chance of nuisance alarms. The laser dust discrimination algorithm further enhances the performance of the range, ensuring a robust solution even in challenging dirty environments. ClassiFire The LaserSense range of detectors continuously adapt their sensitivity to the environment in which they are installed, providing alarm thresholds which are relative to the background smoke levels in the protected area, instead of placing the alarm threshold at a fixed level relative to ambient conditions. At any time, the detector s performance remains constant, regardless of fluctuations in the normal background smoke level, as can be seen in the figure on the right. The bar graph displays on the detectors only show smoke levels significantly above the expected background level, such as from a genuine fire situation. Smoke Density % obscuration / ft The initial 15-minute learning process provides a starting point for environmental compensation. 15 Minutes 1st 24 hours During the first 24-hours, the detector operates at a decreased sensitivity and adjusts to the most stable level using the ClassiFire algorithm. 1 Month1 Year Sensitivity is maintained regardless of changes in ambient conditions. Time Laser Dust Discrimination Laser Dust Discrimination employs a sophisticated algorithm that identifies and eliminates spikes in the obscuration reading caused by particulate matter in the air sample. This makes it possible for the LaserSense range of detectors to reach higher levels of sensitivity without sacrificing reliability. The figure on the right shows how high peaks caused by the presence dust, are eliminated to ensure the real smoke density is clearly visible. Laser signal shows steady output due to smoke and spikes due to dust particles. Spikes are electronically eliminated from detector signal Sensor signal smoke & dust Sensor signal dust eliminated Average 1 Average 2 The remaining steady output represents underlying smoke density Waste-gate Technology Waste Gate Technology is a powerful feature of the LaserSense range, which dramatically extends the life of the particulate filters inside of the detectors. With this technique only a small part of the total air sample is passed through the particulate filter and then to the detector head. The rest of the air sample bypasses the filter and detector head and flows directly to the exhaust of the detector. The presence of combustion products can be measured equally well from a small sample, as from a big sample. This feature ensures a longer service life for the the particulate filters, and in turn more capacity per maintenance cycle.

Products LaserSense Nano Single sampling pipe inlet Up to 750m² coverage Up to 50m pipe length Up to 10 sampling holes Four alarm thresholds SenseNET Networkable Cost effective The LaserSense Nano provides high sensitivity smoke detection in a small package for localized applications. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. The Nano comes with Fault, Pre-Alarm and Alarm relays onboard, as well as a remote input which is user configurable. All configuration on the Nano is done via easy to use dip switches. The Nano is also networkable through SenseNET or the Command Module, with the use of the optional communications board. LaserSense 25 Single sampling pipe inlet Up to 750m² coverage Up to 50m pipe length Up to 10 sampling holes Four alarm thresholds SenseNET Network ready Direct PC connect The LaserSense 25 provides high sensitivity smoke detection in a smaller package for localized applications. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. The LaserSense 25 ships with Fault and Fire relays and an optional Input Relay Card provides four levels of alarm, fault and three programmable remote inputs. Networkable through SenseNET or the Command Module. The detector is housed in a rugged metal enclosure. LaserSense 100 Dual sampling pipe inlets Up to 1400m² coverage Up to 100m combined pipe length Up to 20 sampling holes Four alarm thresholds SenseNET Network ready Direct PC connect The LaserSense 100 provides high sensitivity smoke detection in a medium size package for small to medium applications. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. The LaserSense 100 ships with Fault and Fire relays and an optional Input Relay Card provides four levels of alarm, fault and three programmable remote inputs. Networkable through SenseNET or the Command Module. The detector is housed in a rugged metal enclosure. LaserSense HSSD2 Four sampling pipe inlets Up to 2000m² coverage Up to 200m combined pipe length Up to 100 sampling holes Four alarm thresholds SenseNET Network ready Direct PC connect The LaserSense HSSD2 provides high sensitivity smoke detection for medium to large applications. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. The LaserSense HSSD2 ships with Fault and Fire relays plus three programmable remote inputs. Networkable through SenseNET or the Command Module. The detector is housed in a rugged metal enclosure.

LaserSense Command Module Network management of up to 127 detectors Global network display Global network programmer Multiple configurations SenseNET RS-485 communications RS-232 for PC interface Integral Modbus and BACnet protocol for BMS integration The LaserSense Command Module provides a single location display, control and interface for systems of up to 127 detectors. It provides global programming of all detector functions simultaneously. The LaserSense Command Module is available as standalone, or integrated with a detector. Both supplied in a rugged metal enclosure. The integral bar graph automatically displays the status of the detector on the network with the highest alarm level to identify potential problem areas. Integral Fault and four Alarm relays provide global detector output for integration to other systems. SenseNET PC Graphical System Management Manages all devices centrally Manages 16 loops of 127 detectors Real-time indication of alarms, with sound User definable sound files Displays graphical maps with specific instructions Displays full system status or historical Information SenseNET is a Windows based program that provides central management and monitoring of up to 127 detectors on a fault tolerant communications loop with extensive error checking and correction for utmost reliability. For large campus type facilities, up to 16 loops of 127 detectors per loop, can be efficiently monitored. The ability of SenseNET to produce site maps, warning sounds and to provide spoken instruction messages, which may be unique to each detector, is highly beneficial. Detectors may also be grouped together in zones with an associated zone map, allowing alarms and faults to be quickly and easily located. Sampling Pipes Import.dxf files Fire Dynamics Simulator support Transport time calculation Easy graphics interface Bill of materials creation An integral part of each aspirated smoke detector installation, is the air sampling pipe network. This pipe network can be very simple with only one or two bends, or can be very complex with multiple bends and T s. The design layout is determined by the specific installation requirements, while still staying compliant to local fire regulations. PipeCAD is a Windows based program that provides a design environment where the air sampling pipe network can be designed and also modeled to check the performance. Once a final design has been reached, PipeCAD generates a bill of materials which can be used for ordering purposes. Durable and robust Red clearly distinguishable A full range of air sampling pipes and accessories are available. Pipes are supplied in red, with printed warning text to identify them as the air sampling pipe network of the aspirated smoke detector. Various accessories are available, including remote sampling point assemblies, fittings and adaptors.

Applications Very Early Warning Computer cabinet protection Computer room protection Communication facilities Clean rooms Datacenters Museums High sensitivity smoke detection provided by laser based forward light scatter detection ensures reliable very early warning. This is key to ensure action can be taken even at the incipient stages of a fire, long before there are flames and this way keeping damages to an absolute minimum. LaserSense detectors are arguably the most sensitive of their type and can be thousands of times more sensitive than traditional spot-type detection systems. When such a system is coupled with the ClassiFire Perceptive Artificial Intelligence system, it can provide and maintain optimum sensitivity without external input, maximizing sensitivity and minimizing nuisance alarms. High Airflow Environments Datacenters Communication facilities Clean rooms Dual detection Return air monitoring With the cooling requirements of modem computing environments, cooling systems producing relatively high velocity air currents challenge traditional detection methods. High air velocity cools smoke from an incipient fire, which has insufficient thermal buoyancy to rise to the ceiling where conventional spot type detectors reside. LaserSense detectors actively sample the environment and with their high sensitivity capabilities can overcome the dilution effect providing reliable very early warning in aggressively high airflow environments. In these applications, the LaserSense sampling pipe network is often strategically positioned in front of return air grilles with sample ports positioned towards the airflow to capture particulate from an incipient fire as it is transported by the airflow. Hostile Environments Textile areas Paper mills Flour mills Cold and refrigerated storage facilities Recycling plants Contaminated areas Areas subject to high smoke or dust particulate Record storage warehouses By nature of the system, an aspirated smoke detector has no need to be located within the area it is protecting as the environment from the protected area is transported to the detector via an air sampling pipe network. This means LaserSense detectors can be used in areas of extreme temperatures or high humidity. The ClassiFire Perceptive Artificial Intelligence system ensures optimum sensitivity and performance in practically any environment without the need for external adjustment. LaserSense detectors also incorporate Dust Compensation and Laser Dust Discrimination (LDD³ ), providing highly effective smoke detection in dusty, hostile environments with minimum risk of nuisance alarms.

Concealed Detection Heritage buildings High-end residential Prison cells Architectural and design considerations Where detection is required but for reasons of aesthetic consideration or potential vandalism, it must not be visible or accessible, a continuous air sample can be discreetly drawn via flexible capillary tubes, which are either flush terminated or otherwise concealed in ceiling features. Capillary sampling provides an effective and affordable means to strategically locate the actual sample hole away from the main air sampling pipe run. Many configurations are possible. A wide variety of remote sample port accessories and remote sampling point assemblies are available. High Ceilings Atriums Warehouse and distribution centres Elevator shafts Aircraft hangars Auditoriums Airport terminals Due to the effects of stratification in buildings with high ceilings, it is unlikely that smoke will rise high enough or quickly enough for traditional detection systems to respond. Maintenance access to traditional detection once installed, also poses a problem. LaserSense aspirated smoke detectors utilize a sampling pipe network to actively draw the environment back to a centrally located location. With proper design and strategically located sample ports, the effects of stratification can be overcome and maintenance access simplified. Due to its high sensitivity potential, LaserSense detectors can also overcome the effects of dilution in large open spaces. Maintenance Access Issues Atriums Warehouse and distribution centres Cleanrooms Ceiling voids and below raised floors Record storage facilities Hospitals Classified areas Smoke detectors generally require testing on an annual basis or more frequently depending on local regulations. This requires access to ensure that maintenance personnel can carry out the testing and maintenance. Often this is impractical for traditional detection technologies, as access to equipment may be difficult due to its physical location high on a wall or ceiling, or access might be prohibited to the area where the equipment is located. The air sampling pipe network of an aspirating smoke detector, transports the protected environment back to a strategically located detector, facilitating ease of maintenance, test and inspection.

Safety Security Certainty www.utcfssecurityproducts.eu United Technologies Corporation (UTC) is a diversified company that provides a broad range of high technology products and services to the global aerospace and building systems industries. Its businesses include Carrier heating, air-conditioning and refrigeration solutions; Hamilton Sundstrand aerospace and industrial systems; Otis elevators and escalators; Pratt & Whitney engines; Sikorsky helicopters; and UTC Fire & Security systems. The company also operates a central research organisation that pursues technologies for improving the performance, energy efficiency and cost of UTC products and processes. UTC is a member of the Fortune 50, the Dow Jones Industrial Average and the Dow Jones Sustainability Indexes. UTC Fire & Security is a leading provider of fire safety and electronic security solutions that protect people, property, and assets the world over. Its employees share a commitment to help create safe and secure environments that allow people to live with certainty. With an extensive portfolio of products including fire detection, intrusion detection, access control, and video surveillance, UTC Fire & Security is well-positioned to meet the needs of a broad range of customers. 2012 UTC Fire & Security. All rights reserved. Ref. 1017 EN