FAAST Beyond Standard Methods of Detection

Similar documents
FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST PRODUCT RANGE Aspirating Smoke Detection

and Aspirating Smoke Detection

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Aspirating Smoke Detection PRODUCTS. Accessories Piping Conventional and Intelligent Detectors

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

FAAST. Fire Alarm Aspiration Sensing Technology

Aspir A ation spir P R O D U C T S

Aspirated Smoke Detectors

Aspiration Detection.

1.1 SCOPE 1.2 APPROVALS. A. The Aspirating Smoke Detector shall be tested, approved and/or listed by: 1.3 CODE, STANDARDS, AND REGULATION

LaserFOCUS VLF-250 Engineering Specification

Flexible Air-sampling Smoke Detection

Evolution Analogue Addressable Fire System

HART XL High Sensitivity Smoke Detection

FDA241, FDA221 Siemens ASD

FDA241, FDA221 Siemens ASD

Innovative protection that combines power and flexibility

Engineering Specification Guide VESDA-E VEP

Aspiration Systems for Smoke Detection

The World s No. 1 Brand of Aspirating Smoke Detection

The Next Generation of VESDA Aspirating Smoke Detection Technology

The World's No. 1 Brand of Aspirating Smoke Detector

Aspirating Smoke Detection for Duct Monitoring

The Next Generation of VESDA Aspirating Smoke Detection Technology

VESDA VLP. Engineering Specification

Intelligent Addressable Fire Alarm System

HART XL High Sensitivity Smoke Detection

ASPIRATING SMOKE DETECTION SYSTEMS

The World's No. 1 Brand of Aspirating Smoke Detector

Open-area Smoke Imaging Detector. Engineering Specification

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Buys Time. Aspirating Smoke Detection

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Basic Fire Alarm SystemTraining. Arman Alnasar

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Typical applications include the vibration detector. Detection of vibrations and shocks

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Who is EntryPass? EntryPass Products

LEARNING SPECIAL HAZARD DETECTION TYPES

Intelligent Earliest Warning Aspirating Fire Detector

The World's No. 1 Brand of Air-sampling Smoke Detector

What extinguishes fires without pressure peaks?

CAN unit for Analog Sensors

Buys Time. Aspirating Smoke Detection

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Issue 70 June 2017 THE GLOBAL VOICE FOR PASSIVE AND ACTIVE FIRE PROTECTION

Outdoor Temperature Sensor

Aspirating Accessories: Pipes and Fittings

High-precision aspirating smoke detectors for every requirement.

XYZ XYZ XYZ XYZ XYZ XYZ. Energy Utility Based billing for Individual Tenants. Comprehensive Base Station Monitoring. Diesel Generator Monitoring

For Complete Fire and Gas Solutions

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

FAAST XT 9400XA Fire Alarm Aspiration Sensing Technology

Aspirating smoke detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Fire control panels FC360

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Consultant Specification AGILE Wireless Fire Detection System

-Industrial. W hen All Else Fails... Difficult Applications. The Only TRULY Industrial Air Sampling Detector For Hostile and Difficult Environments

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

CODESEC FIRE ALARM SYSTEMS. security technologies

Analogue Detectors. Series 200 plus

Sensors and Detectors

Open-area Smoke Imaging Detection (OSID)

GO TOGETHER WITH CONSILIUM SUPERIOR ROLLING STOCK SAFETY SOLUTIONS

Dräger Flame 2100 Flame Detection

FAAST XS 7100X Fire Alarm Aspiration Sensing Technology

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

Desigo Fire Safety intelligent detectors for complete safety

Aspirating Smoke Detection (ASD) Systems Fire Detection

Reliably Advanced Extinguishing Control

CertifiedSafetyPassion. CertifiedSafetyPassion. Distributors and UL AML

Protecting Lives and Assets FPD-7024 Fire Alarm Control Panel

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Combined CAN Sensor Unit Temperature, Humidity and Smoke

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

Cerberus FIT conventional system

Safety Instrumented Fire & Gas Systems

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Dräger Flame 2500 Flame Detection

Autronica Fire and Security AS ID:

Control Technologies Fze Ph: E: Sharjah, UAE. M: W:

Aspirating Systems Design and Application Guide

MINERVA MX. 800 Series Ancillary Equipment

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

The EN54 Part 2 and 4 Fire System

A Comparison of Aspirated Smoke Detectors

INTEGRATED PERIMETER SECURITY SOLUTIONS

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Open-area Smoke Imaging Detection (OSID)

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

Product Classroom. Smart sensor, photoelectric sensor, inudctive proximity sensor, laser displacement sensor, area sensor

Transcription:

FAAST Beyond Standard Methods of Detection The statements contained herein are in good faith and provided for general information purposes only. These statements do not constitute an offer or guarantee of performance, as results may vary depending on certain conditions. This document should not be used for other purposes, nor copied without a clear authorization from System Sensor Europe.

Agenda Introduction to Aspiration detection Aspiration Product Portfolio FAAST : Basic System FAAST : Product Features Advantages FAAST FAAST LT : Basic System FAAST LT : Product Features Advantages FAAST LT FACP Integration Sample BOQ Where to Pitch What

Aspiration Smoke Detection A standard Aspiration Smoke Detection system comprises - a high sensitive smoke detector, an air intake fan and a network of sampling tubes that constantly draw air from the target environment into the detector Works as a standalone detector or conventional detector when connected to FACP via a module. Ultrasonic air flow sensing What? Standard Smoke Detector Aspirating Smoke Detector Characteristic Passive waits for smoke Active pulls smoke towards itself Sensitivity 0.5 to 3.43% Obs/m 0.0015% to 20.5% Obs/m Coverage Area Scope Defined by spot detection area Smoke detection in a normal environment/operating condition Determined by aggregate pipe length and # of holes Very early smoke detection in a difficult environment When a standard smoke detector is not an optimum solution

ASPIRATION PRODUCT PORTFOLIO FAAST SYSTEM SENSOR FAAST SYSTEM SENSOR FAAST LT 8100 8100E FL0111E FL0122E System Sensor : 30 years of smoke detection

FAAST : BASIC SYSTEM 1 Aspirator or fan system 2 Piping and sampling points 3 Filter : Patented Particle Separator 2 4 Filter 5 Detector Chamber 4 3 5 1 Launched in 2010; established credibility at a global level

FAAST : PRODUCT FEATURES Dual Vision BLUE and IR Laser IR Laser distinguish dust from combustion particles Blue LED precision smoke detection Detects a wide range of fire with consistent and high level of sensitivity. Multi-Stage filtering WAVELENGTH (nm) Patented particle separator removes larger contaminatesbefore they enter the detection chamber and filter Extends the life of the device Model No Sensitivity 8100 8100E FAAST has an unsurpassed sensitivity of 0.0015 % obs/m. Protects critical assets from any damage. Coverage Area (Sq m) 743 2000 Other Key Features Certification UL/FM VDS, CE Single Single Zone System Networking of detectors : Onboard TCP/IP. Seamless BMS Integration : Onboard Modbus # of Holes 36 36 Notification : 5 relay output along with email notification to customer via onboard TCP/IP. Launched in 2010; established credibility at a global level

Advantage FAAST What? Brand V FAAST 8100/8100E Implications Technology Laser Only BLUE LED + Laser Competitive Advantage Additional Hardware - for BMS Yes No Savings on high end network interface $$ Additional Software for notification via mail Yes No Savings on Software purchase $$ Filtration 2 stage 3 stage Competitive Advantage FAAST : Advanced Detection Technology

FAAST LT : BASIC SYSTEM 1 Aspirator or fan system 2 Piping and sampling points 2 2 3 Filter 4 Detector Chamber 3 3 1 1 4 4 Launched in 2014

FAAST LT : PRODUCT FEATURES Detection Technology Laser Laser detector : high sensitivity to combustion particles, early warning for fire Sensitivity : 0.07 % obs/m. Two Two Zone aspiration detector Gives individual alarms for both zones. Best suited for faster standard detection in large areas with multiple voids. Protection even in Rugged conditions IP rating of IP65 Protection against fire in harsh environments which are not subject to heavy airborne dust particles. Model No FL0111E FL0122E Coverage Area (Sq m) 1600 2000 Certification LPCB LPCB # of Channels Single Dual Class of Protection Class of Protection FL0111E # of holes FL0122E # of holes Total Coverage area (Sqm) Class A 6 150 Class B 12 600 Class C 32 2000 Total Coverage area (Sqm) Class A 3 75 Class B 6 300 Class C 16 1600 Launched in 2014 ; mid market aspiration detector

Advantage FAAST LT What? Brand V FAAST LT FL0111E/FL0122E Implications Technology Laser Laser On par with competition Channellevel addressability No Yes Individualalarms for both channels Detection :Large areas No Yes Faster standard detection Robust No Yes IP65 FAAST LT: Aspiration detector for mid market

FACP Integration Monitor Module Monitor Module Connected via Module Monitor Module Integration via modules : Alarm + Fault displayed on FACP

SAMPLE BOQ System Sensor FAAST System Sensor FAAST LT Description Model No Quantity Description Model No Quantity Description Model No Quantity Description Model No Quantity FAAST Detecor 8100 1 FAAST Detector 8100E 1 FAAST LT Detecor FL0111E( 1 FAAST LT Detecor FL0122E( 1 Power Supply PS-24V-2A/ 1 Power Supply PS-24V-2A/ 1 Power Supply PS-24V-2A/ 1 Power Supply PS-24V-2A/ 1 Flush Capillary Sampling Point 02-1008-15/ Design Flush Capillary Sampling 02-1008-15/ Point Layout Flush Capillary Sampling 02-1008-15/ Point Layout Flush Capillary Sampling Point 02-1008-15/ Layout End Cap 02-1006-25/ Design End Cap 02-1006-25/ Branching End Cap 02-1006-25/ Branching End Cap 02-1006-25/ Branching ABS/ CPVC Design ABS/ CPVC Layout ABS/ CPVC Layout ABS/ CPVC Layout Design Software IQ Free Design Software IQ Free Design Software IQ LT Free Design Software IQ LT Free

Where to Pitch What Category Applications 8100 8100E FL0111E FL0122E Datacenter Clean Rooms Telecom Switch Rooms Mission Critical Process Control Rooms Semi Conductor Fabrication Facility Small Office Server Rooms UPS Rooms Battery Rooms Museums Discrete Detection Religious - Church/Temple/Mosque Historic Structure

Where to Pitch What Category Applications 8100 8100E FL0111E FL0122E Textile Cold Storage Tobacco Processing Harsh Environments Chemical Plants Warehouses Railway Coaches Airport

FAAST : Customer Case Studies KOLKATA INTL AIRPORT. KAIA, SAUDI Total Units Installed 600 at Kolkata and 400 at Saudi MANUFACTURING Total Units 165 Tobacco Products Harsh Environment DATACENTERS ASSET PROTECTION 2012 & 2013 Total Units Installed Over 200 units Abu Dhabi Presidential Palace Total Units installed 100 No 2 in less than 4 years of introduction

FAAST Support Aspiration Solution Design Support STEP 1 Bill of Material STEP 2 Layout Flow reports Technical and Warranty Support Technical support at national level. Addresses all your needs for training, commissioning, warranty support and service. Dedicated Team 1. Vikrant Sharma Technical Manager 2. Chinab Aggarwal Customer Marketing Manager FAAST 3. Vinayendra Jain Sr Product Manager Sensors and Devices Global Company, Local Support

Thank You