Control Unit BROCHURE

Similar documents
Acessories BROCHURE JUNHO 2013

Flame Monitors BROCHURE

Product Overview Combustion Technology

Product Overview Combustion Technology

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

Chemical Processes in the Combustion

COMPACT FLAME CONTROLLER CFC 2000

D-VTA 100-XX BROCHURE

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

PUV, PIR and PFO Series BROCHURE

COMPACT FLAME CONTROLLER CFC 100

Products Catalog. Flame Monitoring & Evaluation Systems

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

UV - flame detector dual fuel burners for intermittent burner operations

D-LX 100 All-In-One Flame Scanner

Combustion Technology. Only those who handle combustion perfectly, can set technical standards.

ABB. Measure IT Uvisor System Dual sensor flame scanner. UR460 Mod. UVIR /ER/EF/DV Flame Scanner Product Data Sheet (rev B)

LFL Series Burner Flame Safeguard Control

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

Products Catalog. Flame Monitoring & Evaluation Systems

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Fibre Optic System D-LL 703/704

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

Burner control unit BCU 370

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

DATASHEET. Burner control unit FDA 601x

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

MBCE-110/230UV Flame Sensor Module

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Burner control unit PFU 780

Model 60200FR Gas Primary Control Data Sheet

Eclipse Self-Check UV Scanner

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

FIREYE C9707A ALL FUEL SCANNER

W-FLAME IR/UV FLAME DETECTOR

Burner control unit BCU 370

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Symphony Plus Combustion instruments

Eclipse 90 UV Scanner Model A Version 1

Burner control units BCU 480

U2 Combination Viewing Head and Signal Processors

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

SGU 930 SGU 930i. Control box

Power Supply Display Module PSDM. Installation and Operation Manual

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

Conspec - Why use our Flame Detectors

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

LAE10 LFE10. Use. Series 02

Talentum - Why use our Flame Detectors?

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

talentum Flame detection across the spectrum Range Brochure

Gas Turbine Flame Monitoring

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

Fireye FLAME SCANNERS

Flame Safeguards LFE10. Building Technologies HVAC Products

MBCE-110/230FR Flame Sensor Module

Fireye Flame Safeguard Controls

Manual MPA 41xx. Edition: Nr GB. Printed in Germany Edition Nr

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

BC-R10 Series. Burner Controllers

UV Flame Supervision System

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Industrial & Commercial Thermal BCU 580

Document code: 1 (10) Issuing date: Status:

Infrared Flame Detectors

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Flame Safeguards LFE10. Building Technologies HVAC Products

Process Alarm Module RTA 421

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

DSF-2010-SB KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE!

S55XB and S55XBE Series Viewing Heads

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Dräger Flame 2350 (UV&IR) Flame Detection

Flame detector FD 2011 / FD 2012

Industrial Flame Monitoring

Infrared Flame Detectors

MMG Gas burner safety control

IFD-E Flame Detector User Manual

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

On the job around the clock 24/7: Fire detection systems

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Flame Detector User Manual

Zircomat Oxygen Analyzers

Old documentation - Only for your information! Product is not available anymore!

TYPE 85UVF/IRF Integrated Flame Scanner with Internal Flame Relay

55UV5 SCANNER MODEL 1010

Transcription:

Control Unit BROCHURE JUNHO 2013

Control unit Self-monitoring and fail-safe control unit for the monitoring of gas, oil and coal flames with DURAG UV, UV+IR or IR flame sensors, primarily in single burner furnaces. D-UG 120 Features suitable for intermittent operation, continuous operation and 72-hour operation according to TRD 604 LED display Installation on DIN-rail. Applications Power stations Chemical industry Refineries Cement plants Waste incinerators Steam generators Heating plants. Certifications DVGW APAVE UL 372 FM Class 7610 GOST-R. Functional description The D-UG 120 control unit analyses the flame radiation via the signal of the flame sensor connected. The easy-to-read LED display shows the operational status of the flame monitor. The flame intensity is present as a current at an output 0/4...20 ma for further analysis. s D-LE 103 for standard applications D-LE 603 for selective flame monitoring D-LE 701/703 for special applications (fibre optics) D-GT 800 for particularly harsh environments sensors for Ex-applications are also available Design Enclosure for DIN-rail mounting. Power supply unit for connecting the D-UG 120 to 230VAC (D-NG 24/05) Digital display for optimal adjustment of the flame sensors by measuring the pulse rate and its extreme values (D-ZS 087-20) Optical adjustment aid for the alignment of the Swivel mount on the sighting tube (D-ZS 118) UV-C test light source 230 V / 50 Hz (D-ZS 077-10) UV-A, UV-B and IR test light source 230 V/50 Hz (D-ZS 093) Swivel mount for alignment of flame monitor to the flame to be monitored (D-ZS 033 - I) Thermal isolator with electrical insulation (D-ZS 117 - I) Ball valve for closing sighting tube (D-ZS 133 - I) Terminal box for connecting flame monitor (D-ZS 140 / 141). Mains adapter D-NG 24/05 Control unit D-UG 120 e.g. D-LE 103 Purge air flange Thermal/ electrical isolator D-ZS 117 I Swivel mount D-ZS-033 I Digital display D-ZS 087-20 Ball valve D-ZS 133 I mode Intermittent operation, continuous operation, 72-hour operation without permanent supervision Configurable switching thresholds 1 Safety Self-monitoring and fail-safe Threshold setting 0...9 Power supply 24 VDC 1 Protection IP20 Display LED Flame relay 1x NO contact, 230 VAC, 2 A Flame intensity 0/4...20 ma Status relay 1x NO contact, 230 VAC, 2 A Installation TS 35 DIN-rail Dimensions 100 x 75 x 118 mm (WxHxD) 14 Safety time 1 s Weight approx. 0.45 kg

Control unit Self-monitoring and fail-safe control unit for the monitoring of gas, oil and coal flames with DURAG UV, UV+IR or IR- flame sensors, primarily in multiple-burner furnaces. D-UG 660 Features intermittent operation, continuous operation and 72-hour operation as per TRD 604 Optional parallel operation of two flame sensors in any combination: UV/UV, UV/IR or IR/IR Three different settings supported for various modes (e.g. dependent on fuel or combustion technology), automatic activation by burner management system Plain text display. Applications Power stations Chemical industry Refineries Cement plants Waste incinerators Steam generators Heating plants. Functional description The D-UG 660 control unit analyses the flame radiation via the pulse signal of the flame sensor connected. The easy-to-read LCD display continually shows information on the defined setting and operational status. The flame intensity and signal are present at two current outputs 0/4...20 ma for further analysis. s D-LE 103 for standard applications D-LE 603 for selective flame monitoring D-LE 701/703 for special applications (fibre optics) D-GT 800 for particularly harsh environments sensors for Ex-applications are also available. Design Plug-in module (21HP and 3RU) for 19 racks (IP00). Digital display for optimal adjustment of the flame sensors by measuring the pulse rate and its extreme values (D-ZS 087-20) Optical adjustment aid for the alignment of the Swivel mount on the sighting tube (D-ZS 118) UV-C test light source 230 V / 50 Hz (D-ZS 077-10) UV-A, UV-B and IR test light source 230 V/50 Hz (D-ZS 093) Swivel mount for alignment of flame monitor to the flame to be monitored (D-ZS 033 - I) Thermal isolator with electrical isolation (D-ZS 117 - I) Ball valve for closing sighting tube (D-ZS 133 - I) Terminal box for connecting flame monitor (D-ZS 140 / 141) Various enclosures and racks for 1 to 4 devices. Certifications DVGW APAVE UL 372 FM Class 7610 AGA: AG 210 GOST-R. Control unit D-UG 660 e.g. D-LE 603 Purge air flange Digital display D-ZS 087-20 Thermal/ electrical isolator D-ZS 117 I Ball valve D-ZS 133 I Swivel mount D-ZS-033 I Second flame sensor mode Safety Power supply Intermittent operation, continuous operation, 72-hour operation without continual supervision Self-monitoring and fail-safe 24/48 VDC, 115/230 VAC Pre-configurable combinations of switching threshold and safety time connection Display 3 1 or 2 (parallel) Protection IP00 Flame intensity 0/4...20 ma Flame relay Status relay 1x switch-over contact, 230 VAC, 2 A 1x switch-over contact, 230 VAC, 2 A Flame signal alpha-numeric LCD display 0/4...20 ma Threshold setting 00...99 Dimensions 19 plug-in module, 3 RU, 21 HP Safety time 1... 5.5 s Weight approx. 1 kg 15

Flame monitor Particularly cost-effective, fail-safe flame monitors for the monitoring of gas and oil burners as well as combined gas/oil burners. AAL 75 D-IR 55 D-UV 55 Features monitoring of gas and oil burners of any load suitable for intermittent operation and continuous operation (only AAL 75 POD) simple installation on TS 35 DIN-rail. Applications Chemical industry Refineries Cement plants Waste incinerators Steam generators Heating plants. Certifications DVGW (not D-IR 55) UL 372 (not AAL 75) FM Class 7610 Functional description The flame monitor comprises of a control unit and flame sensor. Optical flame sensors generate a signal from the UV or IR range of the flame radiation s with an ionisation electrode process a current flowing through the flame Models AAL 75 Ionisation flame monitor for intermittent or continuous operation. Also suitable for single electrode operation in conjunction with DURAG ignition transformers, model D-HG 55. D-IR 55 Infra-red flame monitor for intermittent operation. Analyses flame intensity (flickering) in conjunction with the D-LE 55 ISF-CG flame sensor. D-UV 55 UV flame monitor for intermittent operation. Analyses the flame intensity in conjunction with the D-LE 55 UL-CG flame sensor. Cable for connecting the ionisation electrode to the (klez912f0) Ball valve for closing the sighting tube (D-ZS 133 III) Swivel mount for alignment of the flame sensor to the flame to be monitored (D-ZS 033 III) Test light source for D-UV 55/D-LE 55 for functional test of the flame monitor, battery operated (D-ZS 091). Test light source for D-IR 55/D-LE 55 ISF- CG for functional test of the flame monitor, voltage supply 115/230 VAC / 42-60Hz (D-ZS 093) Thermal isolator with electrical insulation for D-LE 55 UL-CG and D-LE 55 ISF-CG flame sensor (D-ZS 117 III). D-UV 55, D-IR 55 Ionisation electrode AAL 75 Flame monitor (control unit) Type AAL 75 D-IR 55 / D-UV 55 al mode Intermittent operation Intermittent operation Supply voltage 115 / 230 VAC, 50 / 60 Hz 115 / 230 VAC, 50 / 60 Hz Spectral sensitivity D-LE 55 ISF-CG: 790 1050 nm D-LE 55 UL-CG: 190 270 nm Safety time 1 s 1 s, 3 s or 5 s Mounting G 1 or G ½ Display LED LED Protection IP67 www.durag.de Protection IP20 IP20 Dimensions Ø27 mm, length 116 mm Flame relay 2 relay outputs: 250 VAC / 350 ma and 250 VAC / 2 A 1 relay output: 250 VAC / 2 A Installation TS 35 DIN-rail TS 35 DIN-rail Dimensions Weight 68x119x104 mm (WxHxD) 0.55 kg 75x118x70 mm (WxHxD) 0.3 kg Weight 0.45 kg

Zubehör Feuerungsautomat Burner Control D-GF 150 Intermittierender, Dauerbetrieb, 72 Stunden ohne ständige Beaufsichtigung sspannung 220/230 V oder 115 V, intermittent operation, continuous operation, 72-hour operation without permanent supervision Supply voltage 220/230 V or 115 V, Leistung 20 VA Power rating 20 VA Vorspülzeit, einstellbar 30 s - 20 min. Adjustable prepurging 30 s - 20 min. time Programmablauf LED-Anzeige Programme status LED status indicator Sicherheitszeit 3 s oder 5 s Safety time 3 s or 5 s Abschaltzeit <1 s Shut-off time <1 s Schutzart IP 20 Protection IP 20 Zündtrafo und lonisations- Flammenwächter Feuerungsautomat Burner Control ASD-75 sart Sicherheit ASD-75/POI: Intermittierender, ASD-75/POD: Dauerbetrieb Selbstüberwachend und fehlersicher al mode Safety ASD-75/POI: Intermittent operation ASD-75/POD: Continuous operation Self-monitoring and fail-safe Netzspannung 115/230 VAC, Power supply 115/230 VAC, Vorlüftzeit 0 s, 30 s, 60 s oder 120 s Prepurge time 0 s, 30 s, 60 s or 120 s Erste Sicherheitszeit 3 s, 5 s, 10 s oder 15 s First safety time 3 s, 5 s, 10 s or 15 s (Anlauf) (start-up) Flammenausfallzeit 1 s, 2 s, 3 s oder 5 s Flame failure response 1 s, 2 s, 3 s or 5 s time Flammenintensität 0 50 µa Flame intensity 0 50 μa Zul. Umgebungstemperatur Installation Hutschiene TS 35 Installation DIN-rail TS 35 Schutzart IP20 Protection IP20 Anzeige LEDs Display LED Gewicht ca. 1 kg Weight approx. 1 kg Eingänge externer Flammenwächter, 90-110 VDC Flammensignal Inputs external flame monitor, 90-110 VDC flame signal Länge Flammensignalkabel max. 150 m Length of flame signal cable max. 150 m Abmessungen 113x103x118 mm (BxHxT) Dimensions 113x103x118 mm (wxhxd) Steuergerät Control Unit A 240 K 3... für intermittierenden oder Dauerbetrieb, mit potentialfreiem Schaltteil zur Einbindung in eine übergeordnete Brennersteuerung for intermittent or continuous operation, with volt-free relay contact for integration into the main burner management system sspannung 24 VDC Supply voltage 24 VDC Leistung 5 VA Power rating 5 VA Vorspülzeit keine Prepurging time none Sicherheitszeit 3 s, 5 s, 8 s Safety time 3 s, 5 s, 8 s Abschaltzeit <1 s Shut-off time <1 s Signalkabellänge max. 150 m Signal cable length max. 150 m Einbau in 19 -Rack Mounting in 19 -Rack Zünder und Brenner mit Zündtrafo und Ionisations-Flammenwächter 3

Zubehör Flammenrelais Flame Relay A 285 K 2.3 zur Einbin dung in eine übergeordnete Brennersteuerung for integration into the main burner management system sspannung 90-110 VDC Supply voltage 90-110 VDC Schutzart IP 20 Protection IP 20 Signalkabellänge max. 150 m Signal cable length max. 150 m Einbau in Schaltschrank auf 35 mm Hutprofilschiene nach IEC/EN 60715 Mounting in control cabinet on 35 mm rails according to IEC/EN 60715 Kontakte Zündtrafo und Ionisations- Flammenwächter 2 potentialfreie Wechsler, max. 250 VAC, 1 A ohmsche Last Contacts 2 volt-free change-over, max. 250 VAC, 1 A resistive load Ionisations-Flammenwächter Ionisation Flame Monitor AAL 75 sspannung für intermittierenden oder Dauerbetrieb, mit 1 potentialfreien Wechsler 115/230 VAC Supply voltage for intermittent or continuous operation, with 1 volt-free relay contact 115/230 VAC Leistung 10 VA Power rating 10 VA Schutzart IP 20 Protection IP 20 Signalkabellänge max. 150 m Signal cable length max. 150 m Gehäuse Kunststoff Housing plastic Einbau in Schaltschrank auf 35 mm Hutprofilschiene nach IEC/EN 60715 Mounting in control cabinet on 35 mm rails according to IEC/EN 60715 Ionisationselektrode flame rod Gehäuse 2-teilig Kunststoff Two-part housing plastic Zündtrafo und Ionisations- Flammenwächter 4-20 ma Ausgang (nur zu Visualisierungszwecken) optional 4-20 ma output (for visualisation purposes only) optional extra 4 Feuerungsautomat Burner Control D-GF 75 sart D-GF 75-10: Intermittierender, D-GF 75-20: Dauerbetrieb Sicherheit Selbstüberwachend und fehlersicher al mode D-GF 75-10: Intermittent operation D-GF 75-20: Continuous operation Safety Self-monitoring and fail-safe Netzspannung 115/230 VAC, Power supply 115/230 VAC, Vorlüftzeit 0 s, 30 s, 60 s oder 120 s Prepurge time 0 s, 30 s, 60 s or 120 s Erste Sicherheitszeit 3 s, 5 s, 10 s oder 15 s First safety time 3 s, 5 s, 10 s or 15 s (Anlauf) (start-up) Flammenausfallzeit 1 s, 2 s, 3 s oder 5 s Flame failure response 1 s, 2 s, 3 s or 5 s time Flammenintensität 0 50 µa Flame intensity 0 50 μa Zul. Umgebungstemperatur Installation Hutschiene TS 35 Installation DIN-rail TS 35 Schutzart IP20 Protection IP20 Anzeige LEDs Display LED Gewicht ca. 1 kg Weight approx. 1 kg Flammenfühler externer Flammenwächter, Ionisationselektrode external flame monitor, ionisation electrode Länge der Ionisationsleitung max. 150 m (abgeschirmtes Kabel) Length of ionisation cable max. 150 m (shielded cable) Abmessungen 91x103x118 mm (BxHxT) Dimensions 91x103x118 mm (wxhxd)

Contactos/Contacts: Comercial/Commercial: Francisco Lopes e-mail: flopes@bhb,pt Tel: (+351) 21 843 64 00 Fax: (+351) 21 843 64 09 Assistência/Service: Joaquim Picante e-mail: jpicante@bhb.pt Tel: (+351) 21 843 64 00 24 Horas: (+351) 96 523 73 93 Note: DURAG, Inc., the owner of this document, reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. DURAG, Inc. does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. Copyright 2011 DURAG, Inc. All rights reserved