Technical Application Guide for UP-SHINE LED Panel Light

Similar documents
Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

Technical Application Guide for UP-SHINE LED Panel Light

Technical Application Guide for UP-SHINE LED Frameless Panel Light

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Technical Application Guide for UP-SHINE LED Ceiling light

Technical Application Guide for UPSHINE LED Ceiling light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

Technical Application Guide for UP-SHINE LED Downlight

Technical Application Guide for UP-SHINE LED Spotlight

Technical Application Guide for UP-SHINE LED Track Light

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

Technical Application LED Pendant Light LUZ-PL W-W

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

FDV BA- Lighting AS BA24-CL76-8WD

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-SS.

Technical Application Guide for UP-SHINE LED Ceiling light

LED Ceiling Light. Informations. Application notes. Application Areas PS-AL W(-D,-S) Indoor

Welcome. Star Light Technology Group(China)Limited. Star Light Technology Group(China)Limited. Star Light Technology (Shenzhen) Company Limited

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

LED Panel Light E830J

Dimmable LED Retrofit Kit

LED Edge-Lit Flat Panels

LED Shoplight fixture

LED Seamless VaporProof Fixture Installation Instruction

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

The Commercial LED Lighting Specialist

Technical Application Guide for PHILIPS LED Lamps

LED ROUND MINI PANELS

D O M E S T I C LED. Lighting C O M M E R C I A L

ipanel LED Panel Light

SUNIDEA CO.,LIMITED.

TROFFER RETROFIT KIT (TRK)

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

LUXCOMFO TM LED Flood Light Datasheet

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Technical application guide

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

SL2989 Revo 26W Adjust LED Downlight RECESSED LED DOWNLIGHTS

BAS SFP22 Edge-lit LED Panel

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

LED Lights & Parts. World of LED Lights. Product Catalogue 2017 Vol 2. STORE ADDRESS 3695 E 1st Ave, Vancouver, BC V5M 1C2

T8 LED LIGHTING TUBE (LUX V.)

ClearAccent - Affordable recessed LED spot

WARRANTY LED ECO PANEL.

110 lm w STANDARD SERIES

LED Panels. We re excited to unveil our new LED Panels. These new LED panels are ideal for commercial use and fit into standard tile grid systems.

Vaya Linear LP, White & Mono

P5500 LED Architectural Downlighting

A low energy alternative to halogen which provide energy savings of around 90%

Technical application guide

Fortimo LED Line Gen2 Module

AOD LED Panel Light AL-PL

performance PowerBalance, surface mounted Benefits Features Application Specifications

Corn Light. Applications. Key Features. General Usage. 5years

Recessed and surface mounted LED downlight family

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

LED FLAT PANEL EDGE LIT MLFP SERIES G2

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

LED Product Catalogue

IP65 Dimmable LED. Fire Rated, Low Profile Downlights VELA RANGE. Lighting

Classix 6" 6" Round Lens Downlight

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

CoreLine Wall-mounted the clear choice for LED

Fortimo LED Line High Flux Module

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

ENERGY EFFICIENT LED SOLUTIONS

Affordable and reliable energy saving LED Lighting Luminaires

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

LED SLIM DISKS PK613LED FIXED 3-LIGHT ROUND

LED Fire Rated Downlight

Liteharbor Lighting Technology Co., Ltd.

SmartBalance recessed combining performance with smart design

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

LED Elite A19 Series 9W Non-Dimmable All-Purpose A19 A-Lamp 3000 K

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

CoreLine Recessed Spot the clear choice for LED

FPK KELVIN ADJUSTABLE FLAT PANEL 5 YEAR WARRANTY

Ultra Energy Efficient

PRODUCT COLLECTION

FPK - KELVIN-ADJUSTABLE FLAT PANEL

Classix 6" 6" Round Lens Wall Wash

Glacial. COB Inground

Maxos LED General Lighting innovative, flexible solution delivers ideal light output


LED14DR5627K 14W Led 5"/6" Rec DWNLT 27K

HIGH LUMINOUS EFFICIENCY

Classix 6" 6" Round Lens Wall Wash

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

LED Panel Light Specification List

Company Presentation

CoreLine Waterproof the clear choice for LED

Transcription:

Technical Application Guide for UP-SHINE LED Panel Light UP-PL66-36W-S3

Introduction Up-shine led panel adopts high lumen SMD LED with CRI >8. Top branded driver comes with triac dim, -1V dim and DALI dim, it has perfect dimming range and shares great compatibility with worldwide famous brand dimmers. The ultra slim profile fits seamlessly into any work place. It is available in various installation ways: embedded into ceiling, suspended with hanging wires, surface mounted in a concrete ceiling by using surface mounting frame. Up to 8% energy saving compared to standard CFL Long lifetime of 4, hours Triac dim, -1V dim, DALI dim 12 wide beam angle CCT: 3K 4K 5K 57K No UV/IR light Environment friendly, without Mercury or any other hazardous substances Application notes IP4 for indoor use only Professional electrician for installation only Switch off before installation Do not touch when in use Keep away from hot steam and corrosive gas Application Areas Office & school lighting: office room, meeting room, class room etc. Commercial lighting: shopping mall, super market, retailer shops etc. Other situations: hospital, laboratory, dust-free workshop etc. Certificates

595 8. Product Information 595 Technical Specifications Model Voltage Power Power Factor Lumen (±5%) Beam angle CCT Lifespan CRI Dimmable Dimension UP-PL66-36W-S3 AC23V 36W.9 245 12 o 3K 4h 8 No 595*595*8mm UP-PL66-36W-S3 AC23V 36W.9 26 12 o 4K 4h 8 No 595*595*8mm UP-PL66-36W-S3 AC23V 36W.9 263 12 o 5K 4h 8 No 595*595*8mm UP-PL66-36W-S3 AC23V 36W.9 267 12 o 57K 4h 8 No 595*595*8mm UP-PL66-36WD-S3 AC23V 36W.9 238 12 o 3K 4h 8 Yes 595*595*8mm UP-PL66-36WD-S3 AC23V 36W.9 252 12 o 4K 4h 8 Yes 595*595*8mm UP-PL66-36WD-S3 AC23V 36W.9 256 12 o 5K 4h 8 Yes 595*595*8mm UP-PL66-36WD-S3 AC23V 36W.9 26 12 o 57K 4h 8 Yes 595*595*8mm Driver data Sheet Driver data DIM Non-dim Input rated Voltage AC23V AC23V Frequency 5Hz 5Hz Input Voltage AC2-24V AC2-24V Efficiency 83% 86% Total load Wattage 36W±5% 36W±5% Power Factor.9.9 Rated input current.2a.2a Full load output Voltage DC29-33V DC29-33V Rated output current 1mA 15mA Output current range 1mA±5% 15mA±5% Power tolerance ±5% ±5% Current output tolerance ±5% ±5% Dimming range 8%-1% Dimmer Triac dimmers Short circuit protection PASS PASS Over voltage protection PASS PASS Over temperature protection PASS PASS Withstand voltage AC375V AC375V Fixture Compatibility Rated Wattage Electrical Classification Ingress Protection (IP) Operating Temp Operating Humidity Storage Temp 36W Ⅱ IP4-2 o C~45 o C ~9% -2 o C~65 o C

Spectral Distribution 3K 4K.8 Max=5338 [1.=2] 3.5SDCM F3K.8 Max=7171 [1.=2] 2.12SDCM F4K.7.7.6.6.5.4.3 x=.4464 y=.449.5.4.3 x=.3841 y=.3816.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 5K 57K.8 Max=7133 [1.=2] 3.87SDCM F5K.8 Max=7428 [1.=2] 5.57SDCM F57K.7.7.6.6.5.4.3 x=.3467 y=.3678.5.4.3 x=.3459 y=.375.2.2.1.1. 38 5 6 7 8. 38 5 6 7 8 Photometric Diagram 3K 4K -12-9 -/+18 16 12 9 8 6.4 5.6 MH=1m C/18 C9/27 Flux out: 1656 lm 3.281ft 1.88, 71.37fc 1m 214., 768.2lx 6.562ft 4.969, 17.84fc 2m 53.49, 192.1lx 1.15ft 39.5cm 2.31ft 619.cm -12-9 -/+18 18 12 9 9 8.1 6.3 MH=1m C/18 C9/27 Flux out: 1889 lm 3.281ft 22.67, 81.4fc 1m 244., 876.2lx 6.562ft 5.668, 2.35fc 2m 61.1, 219.lx 1.13ft 38.91cm 2.27ft 617.82cm 32 4.8 4 9.843ft 2.29, 7.93fc 3m 23.77, 85.36lx 3.46ft 928.51cm 36 5.4 4.5 9.843ft 2.519, 9.44fc 3m 27.12, 97.35lx 3.4ft 926.73cm 48 3.2 54 3.6 64 2.4 13.12ft 1.242, 4.461fc 4m 13.37, 48.2lx 4.64ft 1238.1cm 72 2.7 13.12ft 1.417, 5.87fc 4m 15.25, 54.76lx 4.54ft 1235.64cm 8-3 3 AVERAGE BEAM ANGLE(5%): 114.3 DEG 1.6.8-25 -2-15 -1-5 5 1 15 2 25 16.4ft.7951, 2.855fc 5.77ft 5m 8.558, 3.73lx 1547.51cm Height Eavg, Emax Angle: 114.26deg Diameter 9-3 3 AVERAGE BEAM ANGLE(5%): 114.3 DEG 1.8.9-25 -2-15 -1-5 5 1 15 2 25 16.4ft.996, 3.256fc 5.67ft 5m 9.761, 35.5lx 1544.55cm Height Eavg, Emax Angle: 114.16deg Diameter 5K 57K -12-9 -/+18 18 12 9 9 8.1 6.3 MH=1m C/18 C9/27 Flux out: 1869 lm 3.281ft 22.46, 8.71fc 1m 241.8, 868.8lx 6.562ft 5.616, 2.18fc 2m 6.45, 21lx 1.13ft 38.91cm 2.27ft 617.82cm -12-9 -/+18 18 12 9 9 8.1 6.3 MH=1m C/18 C9/27 Flux out: 1872 lm 3.281ft 22.46, 8.71fc 1m 241.8, 868.8lx 6.562ft 5.616, 2.18fc 2m 6.45, 21lx 1.13ft 38.91cm 2.27ft 617.82cm 36 5.4 4.5 9.843ft 2.496, 8.968fc 3m 26.87, 96.53lx 3.4ft 926.73cm 36 5.4 4.5 9.843ft 2.496, 8.968fc 3m 26.87, 96.53lx 3.4ft 926.73cm 54 3.6 54 3.6 72 2.7 13.12ft 1.44, 5.45fc 4m 15.11, 54.3lx 4.54ft 1235.64cm 72 2.7 13.12ft 1.44, 5.45fc 4m 15.11, 54.3lx 4.54ft 1235.64cm 9-3 3 AVERAGE BEAM ANGLE(5%): 114.1 DEG 1.8.9-25 -2-15 -1-5 5 1 15 2 25 16.4ft.8985, 3.229fc 5.67ft 5m 9.672, 34.75lx 1544.55cm Height Eavg, Emax Angle: 114.2deg Diameter 9-3 3 AVERAGE BEAM ANGLE(5%): 114.2 DEG 1.8.9-25 -2-15 -1-5 5 1 15 2 25 16.4ft.8985, 3.229fc 5.67ft 5m 9.672, 34.75lx 1544.55cm Height Eavg, Emax Angle: 114.16deg Diameter

Polar Diagram Comparison -15 O +/-18 O 15 O -12 O 12 O -9 O 9 O 3 6-6 O 9 6 O 12-3 O 15 3 O O AVERAGE BEAM ANGLE (5%): 114.2DEG C/18, 114.5 deg C3/21, 114. deg C6/24, 114.1 deg C9/27, 114.4 deg Driver lifetime & LED light decay rate Driver Lifetime LED Light Decay Rate 9 11%.4 Lifetime (hours) 8 7 6 5 4 3 2 1 65 o C 75 o C 85 o C 95 o C 15 o C Capacitor Tc ( o C) % Luminous Flux 15% 1% 95% 9% 85%.35.3.25.2.15 8% 75% FLUX.1.5 U'V' 7%. 1 2 3 4 5 6 7 8 9 1 LifeTime (hours) Temperature The testing is operated at 25 C The lifetime of capacitor, minimum of 5, hours if operated at 15 C, will be doubled whenever the temperature drops 1 C The highest withstand temperature of IC, MOS could be 12 C The highest withstand temperature of LED junction temperature is 15 C 8 Temperature ( o C) 7 6 5 4 3 2 1 14:29:22 15:2:16 16:11:16 17:2:16 17:53:16 18:44:16 19:35:16 2:26:16 21:17:16 22:8:16 22:59:16 23:5:16 :41:16 1:32:16 2:23:16 3:14:16 4:5:16 4:56:16 5:47:16 6:38:16 7:29:16 8:2:16 Time The driver lifespan is based on capacitor working temperature. IC Capacitor MOS PCB Fitting Voltage transformer Environmental temperature

Installation 1.Recessed into ceiling 1. Remove ceiling plaster slab 2. Connect power supply 3. Fix the panel light into right place 4. Stabilize the panel 2. Suspending 1. A.Fix the anchor into target place on the ceiling B.Fix the installation mount on the ceiling with plastic anchor 2. Hang the panel to ceiling with suspended installation kits 3. Adjust the length of steel wire. Connect the power supply 3. Surface mounted 1. Fix the bracket of panel light on the ceiling 2. Install hanging fixtures on the panel light 3. Install the LED Panel light on the bracket 4. Connect the power cord and then it can be used 4. Surface mounted 1. Fix the frame on the ceiling with screw 2. Pull down the side frame 3. Push the panel into the frame, connect the driver 4. Install the side frame 5. Turn on the power switch, finish the installation Packaging Information SIZE(CM) N.W/pc (KGS) G.W.(KGS) Q'TY(PCS) Carton 66.5*34.5*73 4.2 27.5 5 CTNS Q'TY(PCS) VOLUME(CBM) 2'' standard container 4'' standard container 164 82 28 33 165 56 Phone: +86 755 2919 7389 Add: 2nd building Dingfeng High-Tech Zone, Fuyuan 1st road, Fu Yong Sub-district, Bao'an, Shenzhen China