HVAC Equipment Access Equipment Location

Similar documents
Inspection Checklist Mechanical Rough in

Inspection Checklist Residential Mechanical Rough In July 2016

Mechanical Appliance and Equipment Inspection Checklist

2015 MECHANICAL CODE REQUIREMENTS

Inspection Checklist Mechanical Final

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

C O D E S & A M M E N D M E N T S

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

2012 INTERNATIONAL FUEL GAS CODE VENTS

1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights

Habitability Guidelines

Building Department Informational Handout

CHIMNEYS AND VENTS CHAPTER 8

DUCT SYSTEMS CHAPTER 6

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

CHAPTER 8 CHIMNEYS AND VENTS

DUCT SYSTEMS CHAPTER 6

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

DUCT SYSTEMS CHAPTER 6

CHAPTER 8 CHIMNEYS AND VENTS

IMC Significant Changes Summary Tier I

BUILDER S PRE-INSPECTION CHECKLIST

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION

GENERAL BASIC INSTALLATION INSTRUCTIONS DIRECT FIRED HOT WATER BOILERS PARKER BOILER CO.

GENERAL BASIC INSTALLATION INSTRUCTIONS INDIRECT GAS FIRED WATER HEATERS PARKER BOILER CO.

Ventilation for New Low-Rise Residential Buildings July 20, 2015

NC Mechanical Code. Land Use and Environmental Service Agency (Code Enforcement) Table of Contents

Appendices. Provisions in the appendices shall not apply unless specifically adopted or referenced in this code.

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

Introduction Service Pipe Application Important Terms Air Requirements... Appliance Location... Venting... Calculations...

TABLE OF CONTENTS. Part I Administrative... 1

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Gil Rossmiller. In the construction industry for over 30 years. ICC IRC Plumbing & Mechanical Code Development Committee

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

BUILDER S PRE-INSPECTION CHECKLIST

SAFETY AND INSTALLATION MANUAL MODEL 8100

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2000 EDITION

Do not use this vent pipe or fittings for venting incinerators of any kind.

Notable Changes in the Mechanical Codes

Uniform Dwelling Code 2017 Updates SPS 323

CHAPTER 5: EXHAUST SYSTEMS

Summary of BBS Proposed Ohio Mechanical Code Rule Changes October 2016

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Item # 1 Comment Seq # 1 UMC 2012 (Chapters 1 15): Chair, UMC Correlation Task Group (Manual of Style)

SPECIFIC APPLIANCES CHAPTER 6

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2007

HOME INSPECTOR EDUCATION EXPO 2016

This standard shall prescribe provisions based on minimum requirements for safety to life and property.

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

SPECIFIC APPLIANCES CHAPTER 6

Land Use and Environmental Service Agency (Code Enforcement) NC Mechanical Code. Table of Contents

Venting of Gas Fired Equipment RV

TABLE OF CONTENTS. Part I Administrative... 1

2012 International Mechanical Code Significant Changes. About the Significant Changes

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS SL280UHNV

INSTALLATION INSTRUCTIONS

SPECIFIC APPLIANCES CHAPTER 6

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

The Heating System and Ventilation and Combustion Air

Land Use and Environmental Service Agency (Code Enforcement) NC Mechanical Code. Table of Contents

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

CHIMNEY INSTALLATION. Technical Bulletin #1

Desiccant Dehumidifier

2012 International Fuel Gas Code Design, Installation and Inspection Principles

Excellent Home Inspection Services, LLC

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2006 EDITION

PLAN REVIEW SUBMITTAL GUIDE

CHAPTER 6 SPECIFIC APPLIANCES

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instructions

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

20/20 Home Inspections. Photo Attachments

2009 ELECTRICAL CODE REQUIREMENTS

Installation Instructions

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

CHAPTER 7 WATER HEATING EQUIPMENT AND VENTS

Installation Instructions

TABLE OF CONTENTS. Part I Administrative

X Article/Section 902.0(D) X X X X X X X X X X X

Fundamentals of the 2012 International Mechanical Code

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

Installation Instructions

DOCUMENT TABLE OF CONTENTS

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS G60UH(X) Series

Equipment Specifications and Required Information Quantity Rebate

MBPA Home Performance FIELD DATA COLLECTION FORM

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

INSTALLATION AND SERVICE MANUAL

Transcription:

City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating, and Air-Conditioning Systems Equipment Access 30 inches deep minimum workspace on the control (front) side of equipment 18 inches deep minimum front side workspace on room, wall and unit heaters Door to enclosed equipment room 24 inches wide and 30 inches deep minimum or must be greater than the size of the equipment. 30 inches minimum clearance from front side to end of opened door to equipment room. Equipment Location Attic Access minimum 22 inches by 30 inches or dimension of appliance Maximum distance from access opening to equipment is 20 feet. Solid floor from access opening to equipment minimum 24 inches wide. Minimum 30 inch by 30 inch platform in front of service side of unit. Upright furnace requires minimum 5 feet headroom clearance Lighting outlet must be switched from access door to equipment. Under floor Appliance mounted on slab must be elevated 3 inches above grade minimum Appliance suspended from joist must be minimum 6 inches from ground and minimum 12 inches if located in a flood plain area. Access space to pass equipment opening must be 22 inches by 30 inches minimum or per manufactures Passageway not required if equipment can be serviced or removed from access opening. Access door maximum 20 feet to equipment location. Access door rough opening 22 inches by 30 inches minimum or 18 inches by 24 inches if a floor furnace. Light switch must be located at access door to equipment. Below ground mounted units must have 12 inches minimum clearance on all sides. 30 inch by 30 minimum clearance, level space on service side unless otherwise specified Below ground mounted units excavation greater than 12 inches, line with concrete or masonry to 4 inches above grade. Garage Furnace unit with any flame or sparking devices must be mounted greater than 18 inches above garage floor. Furnace unit and all components must be protected from physical damage such as protective bollards. Ducts ran through fire-resistive wall s must be 26 gauge thickness. No duct opening may be made into the garage area(s). Roof top All equipment must be listed for outdoor location or be protected per manufactures All equipment must be securely anchored in place using seismic design category D1 or D2 (wind loading, ice loading for Ohio) A 30 inch platform must be installed at the equipment site Accessibility to equipment must use a catwalk with railing for sloped roofs.

Appliance Installation Approved plans and permit must be on-site for new installations. All equipment shall be listed and labeled for the intended use. All installation instructions must be on-site Alterations & repairs shall comply with current code. Alterations & repairs cannot make the current system overloaded Mechanical systems shall be properly maintained. Provide access for removal and servicing Use only designated fuel(s) unless factory approved kit is installed and labeled. Configuring equipment sizing shall be per approved methods Foundations for outdoor installations shall prevent movement of equipment. A heat source is required in each habitable room All vents, caps, and flashing must be fasten or anchored in approved manner. If more than one system, permanently mark each system and what it serves. All drilling and notching of wood must be per building code, Electric Central Heat All branch circuits must be sized for 125% of the anticipated heating load The maximum unsubdivided load current is 48 amperes. A disconnecting means must be in sight of the heating equipment Electric Baseboard Heat Must be installed per manufacturers specifications and listing No electrical receptacles are permitted above permanently installed heaters No baseboard heaters can be permanently installed below a receptacle Electric Radiant-Heat Systems Must be installed per manufacturer s instructions All heating panels must be installed parallel to the framing All fasteners must be more than ¼ inch from the heating element(s) No field modifications of the heating panels is permitted No bridging of expansion joints is permitted when installed in concrete. Electric Duct Heaters Must be installed per the manufacturer s instructions. If located less than 4 feet from heat pump/air conditioning units, both must be listed for clearances less than 4 feet. All duct heaters installed must be accessible for servicing. All duct heaters must have an interlock that prevents operation without a blower. Central Forced-Air Furnace All fuel burning furnaces cannot be open to bedrooms, storerooms or bathrooms. All fuel burning furnaces must be behind gasket self closing doors AND all combustion air is supplied from the outside to the enclosure OR use of a direct vent type with enclosed combustion chamber. All furnace room passage openings must be 24 inches minimum wide. Must provide a work space depth of 30 inches, height of 30 inches or to the height of the unit. The total space provided must be 12 inches greater than the furnace. Replacement furnaces located in exiting alcoves must have clearance per manufacturers labels

Distance from the combustion chamber measured horizontally to the closed door of the enclosure must be a minimum of 6 inches. Return air duct intake must be a minimum of 10 feet from any combustion such as a gas water heater or gas clothes drier or be separated by a tight-fitting door. An electrical receptacle must be provided within 25 feet of the furnace. The automatic outlet air temperature must have a limit system for temperatures over 250 degrees F. An air filter is required on all furnaces. Condensing High-Efficiency Furnace The flue must be gas tight The flue cannot have any other natural or forced vents Y into the same piping. A condensate drain pipe is required and must not exit into a public way or nuisance location. The drainpipe cannot be less than ¾ inch pipe with less than a 1/8 inch per feet slope. The drainpipe is permitted to be connected to indirect receptor such as a lavatory, tub overflow or tailpiece. Heat Pumps & Air Conditioning Heat-pump return air minimum clearance area is 6 square inches per 1,000 BTU of output An air filter is required Outdoor unit must be mounted on a minimum 3 inch thick raised pad sloped to drain defrost water. Horizontal air handler must be set level or slightly sloped to condensate drain. No cooling coils can be mounted upstream from heat exchangers. All refrigerant vapor or suction lines must be insulated using minimum R-4 insulation. Installer must use nail-plate protection for refrigerant piping closer than 1.5 inches of framing edges. The condenser unit cannot be placed next to a dryer output vent. Use of a heat pump with strip (emergency) heaters requires a two-stage thermostat. Heat-Pump Return & Supply Main Duct Sizes BTU Rating 24,000 30,000 36,000 42,000 48,000 60,000 Tons 2 2.5 3 3.5 4 5 Blower sq.in. 144 180 216 252 288 360 Round duct dia. 14 16 18 18 20 20 Electrical Requirements Power disconnect must be insight of condenser unit Must maintain working clearance in front of disconnect (cannot mount disconnect directly behind condenser unit). The thermostat cable cannot be run through the same conduit as the power conductors. Conductor sizes must be rated the same as the overcurrent nameplate rating of the unit. Window and Through-Wall Units Maximum permitted cord length is 10 feet for 120 volt units and 6 feet for 240 volt units. Cord & plug may serve as a disconnecting means if unit controls are less than 6 feet from floor. The maximum load can only be 80% of the rating of the single branch circuit. Maximum 50% of the rated load if the cooling circuit has other outlets.

Condensate Condensate may not drain to any public street or way. The drainpipe cannot be less than ¾ inch and must slope 1/8 inch per feet. Use of PVC female threaded fittings is prohibited Drain line may not be directly connected to waste or vent pipes. The drain line may connect to indirect receptor such as lavatory, tailpipe or bath tub overflow. A secondary drain and/or pan required for equipment mounted above framing. The secondary drain must drain to conspicuous point of disposal. A water level detector device in the overflow pan may be used in lieu of a pan drain. Drilling of other pipes to accept drain pipes is not permitted. Evaporative (Swamp) coolers Units mounted at ground level must be placed on 3 inch minimum base and be level. Units mounted on platforms must be no less than 6 inches above grade All supports must be rated per manufactures Openings into buildings must be flashed. A backflow water protection device must be used on potable water supplies. Ducts Ducts insulation shall not flame or smoke (no class 2 ducts) Concealed ductwork must be #30 gage sheet or greater if less than 14 inches Exposed ductwork must be #28 gage or greater if less than 14 inches Riser that is factory-made cannot raise vertically more than two stories. Fire blocking must be used around duct where passing between floors in concealed spaces. Fire stopping damper must be used between occupancies per manufactures Penetration between house and garage No duct openings into garage Ducts used in attached garage must be greater than 26 gage sheet steel. Return Air Must have sufficient volume = 25% of the area served No ducts mounted in bathrooms, kitchen, garage, furnace room, or another dwelling. Ducts must be no closer than 10 feet from natural draft appliances using combustion chamber or draft hood or wood burning fireplace. All ducts must be 2 square inches per KBtu output or per manufactures Air conditioning and heat pumps return air ducts minimum clearance area is 6 square inches per 1,000 Btu nominal. Studs used as partition or cavities are permitted if not greater than one floor in height and isolated with tight-fitting metal or 2 inch wood. Gypsum board permitted in return air if air is less than 125 degrees and no moisture. Central Heating Main Duct Sizes Btu 50K 60K 80K 100K 125K 150K 200K Gravity feed 280 336 448 560 700 840 1120 Gravity round duct 20 22 24 30 30 36 42 Blower sq. in. 80 96 128 160 200 240 320 Blower round duct 12 12 14 16 16 18 22

Supply Air Ducts must be minimum 2 sq.in. per KBtu output rating or per manufacturer Ducts must be minimum 6 sq.in. per KBtu nominal rating for AC or heat pump or per manufacturer Stud or partition cavities not approved for supply air. Vibration isolators can be a maximum of 10 inches long. Installation Distance from duct to ground must be 4 inches minimum. Ducts in concrete must be encased with a minimum 2 inches of concrete unless factory protected. No flexible ducts are permitted underground All joints must be airtight. All manufactured ducts must be tapped with UL181 tape. All joints to the air-handler equipment must be mechanical. Flexible duct must be supported using an 11/2 inch strap every 4 feet or per manufacturer Metal duct must be supported every 10 feet minimum. All ducts in garages must be protected from physical damage. Combustion air Combustion air ducts are normally two ducts running from the outside air supply to the furnace room. One duct stops at the ceiling level and the other stops low to the floor level close to the appliances that are burning oil or gas. The lower duct serves to provide fresh air to the appliance and the higher duct provides an exhaust for any fumes. As houses are built tighter and to higher energy-efficiency standards, the interior of the building does not provide enough fresh air to supply and fully burn the fuel at the correct temperature, as a result deadly carbon monoxide can be a product of the combustion. Duct for the upper opening may not slope down to the fresh air intake. Ducts entering from the outdoors must be fitted with a ¾ inch or larger mesh screen. No screen is necessary for ducts ending in the attic. Maintain duct separation from furnace room to fresh air source. Duct openings must terminate in open space in front of the appliance firebox. The area around the appliance must remain open space from floor to ceiling No dampers are permitted in combustion air ducts Use of joist/stud bay is acceptable if not greater than one fire block removed. Consider exhaust fans when determining combustion-air requirements. Confined space is less than 50 square feet. Unconfined space is greater than 50 square feet. Appliances installed in unconfined space may rely on infiltration alone. Installers should follow manufacturer instructions for combustion air. Two openings are required from confined space to adjacent unconfined space required, one at top of ceiling and one less than 12 inches from floor level. Openings to unconfined spaces must be a minimum of 100 square inches. Openings to confined spaces must be 1 square inch per 1,000 Btu. Combined Inside and Outside Source- Nontight construction only Ducts may draw through two 100 square inch openings from adjacent space & one opening to an external source required at 1 square inch per 3,000 Btu per hour.

Outside source (required for tight construction) One single opening is permitted at upper 12 inch section of enclosure directly connected to external source with minimum 1 square inch per 3,000 Btu and greater than or equal to the cross sectional area of all vent connectors. Crawl space source Crawl space air may only be used for lower combustion use only. Minimum opening shall be 1 square inch per 4,000 Btu of input. Ventilation into crawl space must be increased two-times the normal amount required. The crawl space must meet the minimum building code regulation code requirements, 18 inches from joists to earth clearance. Combustion Air- Opening Sizes Inside Air Outside Air Openings BTU Opening size Cubic feet min. 1 in./2k BtuPH 1 in./4k Btu PH 30,000 1,500 (188 sq.ft) 15 sq.in. 7.5 sq.in. 40,000 2,000 (250 sq.ft.) 20 sq.in. 10 sq.in. 50,000 2,500 (313 sq.ft.) 25 sq.in. 12.4 sq.in. 60,000 100 sq. inch 3,000 (375 sq.ft.) 30 sq.in. 15 sq.in. 80,000 4,000 (500 sq.ft.) 40 sq.in. 20 sq.in. 100,000 5,000 (625 sq.ft.) 50 sq.in. 25 sq.in. 125,000 125 sq. inch 6,250 (781 sq.ft.) 62.5 sq.in. 31.3 sq.in. 150,000 150 sq. inch 7,500 (938 sq.ft.) 75 sq.in. 37.5 sq.in. Area of a Circle Dia. Area (square inches) 3 inch 7 sq. inches 4 inch 12.6 sq. inches 5 inch 20 sq. inches 6 inch 28 sq. inches 7 inch 38.5 sq. inches 8 inch 50.3 sq. inches 9 inch 63.6 sq. inches 10 inch 78.5 sq. inches 12 inch 113 sq. inches 14 inch 154 sq. inches 16 inch 201 sq. inches Other references can be found in the 2005 Ohio Mechanical Code and the International Building Code 2003 version.