INSTALLATION INSTRUCTIONS

Similar documents
USER INSTRUCTIONS Fir Road, Mishawaka, IN Phone: (574) Fax: (574)

USER INSTRUCTIONS Fir Road, Mishawaka, IN Phone: (574) Fax: (574) Page 1 of 15

Installation Manual PS-225 & PS-275

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

General System Layout Sketch

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Manual PS-200 & PS-201

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions PRO SERIES

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Thermostatic Concealed Shower Valve

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

HYDROGEN SULFIDE REMOVAL SYSTEMS

SYSTEMS for CATALYTIC FILTERS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

COPPER FREESTANDING TUB

General System Layout Sketch

Installation Instructions

HOT TANK INSTALLATION INSTRUCTIONS

SuperKlean Washdown Products

DRAIN WATER TEMPERING INSTALL

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

569, 570, 571, 572 Series

569, 570, 571, 572 Series

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SuperKlean Washdown Products

Installation and Owners manual

ACT Cartridge Dust Collector

KITCHEN FAUCET COS-KF222C

INSTALLATION INSTRUCTIONS

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

INSTALLATION INSTRUCTIONS

Installation Manual for M-G014 & M-G015

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation Instructions

FAUCET REPAIR RV PARTS & ACCESSORIES RV PARTS & ACCESSORIES FAUCET STEMS FAUCET ESCUTCHEONS

ERGOMAX 7 INSTALLATION

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Installation and Owners manual

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

K-870-JA-AA K-872-JA-AA

Installing the Turbo Floor Model System

WASHER & DRYER REPAIR

568X, 587X, 588X Series

Downdraft Ventilation

Installation Instructions

TOOLS & MISCELLANEOUS

Acrylic Claw Foot Tub

THE BEAUTY OF WATER THE SCIENCE OF RENEWAL. Heating Circulation System. Installation Instruction Manual

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

K4600 Assembly Directions

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

THERMOSTATIC SHOWER CONCEALED VALVE - TWIN WITH DIVERTER & TRIPLE WITH DIVERTER

SPEAKMAN SPEAKMAN SPECIFICATIONS

Handshower, Hose & Handshower Accessories

Installation Instructions Built-In Dishwasher

Acrylic Claw Foot Tub

General System Layout Sketch

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

BEFORE OPERATING THE MACHINE: WARNING

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation and operating instructions. E.2 Series high efficiency circulator

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

Installation Instructions

CLe-series Dishwashers

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

FREWIN STEAM SHOWER ENCLOSURE

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

Instant Hot Water Dispenser Owner s Manual

ODIN Backwash UNIT Installation Instructions

Installation and Operation Manual MG-304. Please read this manual carefully before use.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

E.2 series high efficiency circulator. Installation and operating instructions

INSTALLATION INSTRUCTIONS GEO PRIME TANK. (Patent Pending) GPC

INSTALLATION INSTRUCTIONS

Installation Instructions

CAST IRON CLAWFOOT TUB

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Heating and ventilation system,

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Installation and Operating Instructions

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

INSTALLATION INSTRUCTIONS

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

INSTALLATION AND OPERATION MANUAL

Installation, Operation & Maintenance Instructions

Basin Set INSTALLATION INSTRUCTIONS

Transcription:

Items Included in System: Polar White Part # s 301-032-00002 301-032-00006 301-032-00011 Black Part # s 301-032-00003 301-032-00005 Atmospheric Vacuum Breaker/Check Valve Part #571 VAC CHK Spin Weld Spray Head Part #631 OR ABS Tank Spray Head Part #571 Sprayer Label Part #103-002-00014 Page 1 of 15

Improper installation, operation or servicing this product will result in equipment damage & personal injury. This product should be installed & serviced by qualified technical personnel who have an in-depth knowledge of the construction process and potential hazards of this type of system. All B&B installed fittings are torqued to factory settings. Loosening or tightening these connections will result in potential leakage or damage voiding warranty consideration. All plumbing connections made to this product during installation should be hand tight plus ¼ turn. DO NOT over-tighten!! DO NOT "operate" equipment at power levels other than what is specified on equipment serial tag & data plate. Make sure tank fittings for black water tank flushing (ABS Tank & Rotomolded) are installed per instructions to avoid potential damage. DO NOT install panel with plumbing in a binding condition. Plumbing must have necessary room to move freely when panel is secured to mounting substrate. Double check ALL factory installed swivel fittings to hand tight plus ¼ turn due to potential loosening. OEM Manufacturer to provide user instructions clearly advising proper winterizing techniques. Damage to system due to incorrect winterizing techniques voids all warranty consideration. B&B Molders is not responsible for damage caused to other products connected to this system. It is the O.E.M. Manufacturer's responsibility to ensure plumbing is run to correct locations. Proper venting of freshwater holding tank is responsibility of RV manufacturer. (See B&B Power Vent for safe venting options.) Under sized vents may result in serious damage. Special rules apply for any warranty claim or submission. Please contact B&B Molders for further information. Do not use countersink headed screws due to potential cracking. Use only #8 pan headed screws. Nautilus System is designed for compartment use only and should not be used for exterior applications where exposure to exterior elements exists. System must be installed in a clean environment at O.E.M. free of dust and debris. Foreign contaminates have been proven to create leakage conditions. Optional: If this product comes equipped with a hot/cold faucet, make sure hot and cold are connected correctly. All plumbing connections made to this product during installation should be hand tight plus ¼ turn. Tank Flush DO NOT over-tighten swivel fitting to threaded water inlet connection. Over-tightening may result in stress cracking to plastic threads. DO NOT plumb Atmospheric Vacuum Breaker/Check Valve (Vac/Check) in a binding condition that puts stress on part. Plumbing should be securely fastened to permanent structure. B&B strongly recommends installing Vac/Check within 6' 8' of water inlet due to low pressure conditions. Vac/Check must be installed in an easily accessible location to end user. Vac/Check assembly must be plumbed in proper direction of flow & orientation. Working pressure per ASSE #1001 is 125 psi but NOT LESS THAN 8 psi. Spin weld fitting/sprayer must be installed according to Standard Plastic Welding Guidelines. IMPORTANT: FAILURE TO FOLLOW THESE INSTRUCTIONS FOR INSTALLATION OF OUR PRODUCT WILL FORFEIT ANY WARRANTY CONSIDERATION. Page 2 of 15

IMPORTANT!! NEVER push check valve on "CITY WATER" connection with pressure in line. This WILL cause irreparable damage to the check valve function. Page 2 of 15

INSTALLATION INSTRUCTIONS Nautilus P1 Handle Position and Valve Routing Information WHITE HANDLE: Receives water from water inlet on front of panel Sideways water goes into blue handle diverter Down water goes to pump inlet BLUE HANDLE: Receives water from white handle valve/water inlet on front of panel Sideways water goes to or comes from fresh water tank Down water goes to fixtures (cold) BLACK HANDLE: Is an on/off flow through valve that feeds pump from fresh water tank Sideways - water will not flow through valve Down water goes to or comes from fresh water tank RED HANDLE: Receives water from cold water supply line Sideways - water goes to hot water fixtures without going through hot water heater Up water goes to hot water heater GREEN HANDLE: Receives water from pump Sideways - water goes to fresh water tank Up water goes to fixtures

PLUMBING HARNESSES There are five different plumbing harnesses that are necessary on the Nautilus P1 Panel. 1 FRESH WATER TANK "IN" HARNESS: The (Fresh Water Tank In) line has two panel connections marked with a 1 on back side of Nautilus panel: "TANK FILL (PUMP)" & "TANK FILL (CITY)." 2 HOT FIXTURES HARNESS The (Hot Fixtures) line has two connections marked with a 2 on back side of Nautilus panel: "HOT" & "HOT WATER LINE/OUT." Items Needed for Harness: (2) 90 swivel fittings, (1) inline tee ½" Pex tubing lines (1) 1½", (1) 4 ¾ (4) ½" Oetiker clamps Items Needed for Harness: (2) 90 swivel fittings, (1) inline tee ½" Pex tubing lines: (1) 1½", (1) 73/4 (4) ½" Oetiker clamps Page 3 of 15

PLUMBING HARNESSES 3 WITH WATER FILTER If unit has a water filter, connect "WATER INLET" at bottom of panel to (Filter In) and connect (Filter Out) to "WATER INLET" marked with a 3 in middle of panel. WATER INLET HARNESS 3 WITHOUT WATER FILTER If unit does not have a water filter, run plumbing line from "WATER INLET" at bottom of panel to "WATER INLET" marked with a 3 in middle of panel. Items Needed for Harness: (2) 90 swivel fittings ½" Pex tubing line (1) 1¾" (2) ½" Oetiker clamps Page 4 of 15

PLUMBING HARNESSES 4 COLD WATER SUPPLY HARNESS The (Cold Water Supply) line has four connections marked with a 4 on back side of Nautilus panel: "COLD" on shower faucet, "COLD LINE SUPPLY," "FIXTURES (PUMP)," "CITY TO FIXTURES." 5 PUMP INLET HARNESS Line to (Pump Inlet) has two connections marked with a 5 on back side of Nautilus panel: "TO PUMP INLET" (there are 2 of these). Items Needed for Harness: (4) Straight swivel fittings (4) 90 inline elbows, (3) inline tees ½" Pex tubing lines: (4) 2½, (2) 1¾", (2) 2¾", (4) 3⅜" (20) ½" Oetiker clamps Items Needed for Harness: (2) Straight swivel fittings (1) 90 inline elbow, (1) inline tee ½" Pex tubing lines: (2) 1½", (1) 7 ⅞ (6) ½" Oetiker clamps Page 5 of 15

PLUMBING HARNESSES - OTHER Line from (Pump Out) has one connection on back of Nautilus panel: "PRESSURE FROM PUMP." Line from (Fresh Water Tank Out) has one connection on back of Nautilus panel: "IN FROM TANK." Line to (Hot Water Heater In) has one connection on back of Nautilus panel: "TO H2O HEATER." Page 6 of 15

1. Cut a 10" x 15" opening in substrate material & feed appropriate connections through opening. 2. Connect plumbing harness 4 (Cold Water Supply) to back of Nautilus panel at four locations marked with a 4. Screw plumbing swivel fittings onto diverter valve ends in the following order: "FIXTURES (PUMP)," "CITY TO FIXTURES," "COLD LINE SUPPLY" & "COLD" on shower faucet. 10" 15" Page 7 of 15

3. Connect plumbing harness 5 (Pump Inlet) to back of Nautilus panel at two locations marked with a 5. Screw plumbing swivel fittings onto each diverter valve end labeled "TO PUMP INLET." 4. Connect plumbing harness 1 (Fresh Water Tank) to back of Nautilus panel at two locations marked with a 1. Screw plumbing swivel fittings onto diverter valve ends in the following order: "TANK FILL (CITY)," "TANK FILL (PUMP)." Page 8 of 15

5A. UNITS WITH WATER FILTER Connect plumbing line running from (Filter In) to "WATER INLET" located at bottom of Nautilus panel. 5B. UNITS WITHOUT WATER FILTER Connect plumbing harness 3 (Water Inlet) to back of Nautilus panel at two locations marked with a 3. Screw plumbing swivel fittings onto diverter valve ends labeled "WATER INLET." Connect plumbing running from (Filter Out) to to diverter valve end labeled "WATER INLET" located at middle right of Nautilus panel marked with a 3. Page 9 of 15

6. Connect plumbing line running from (Hot Water Heater In) to diverter valve end labeled "TO H2O HEATER" on back of Nautilus panel. 7. Connect plumbing harness 2 (Hot Fixtures) to back of Nautilus panel at two locations marked with a 2. Screw plumbing swivel fittings onto diverter valve ends in the following order: "HOT WATER LINE/OUT," "HOT" on shower faucet. Page 10 of 15

8. Connect plumbing line running from (Pump Out) to diverter valve end labeled "PRESSURE FROM PUMP" on back of Nautilus panel. 9. Connect plumbing line from (Fresh Water Tank Out) to diverter valve end labeled "IN FROM TANK" on back of Nautilus panel. Page 11 of 15

10. Connect plumbing line running from bottom of listed Vac/Check to inlet labeled "TANK FLUSH." 11. Connect necessary coaxial cables to to appropriate connection identified on top left of panel and hand tighten. 12. Connect power service to terminals on back of pump switch located on top right of panel as illustrated below. SEE TANK FLUSHER INSTALLATION INSTRUCTIONS #1, PAGE14. **Make sure wiring connection is routed correctly for two switch operation. Page 12 of 15

13. Secure panel to substrate material using (10) #8 self-tapping pan headed screws. Page 13 of 15

TANK FLUSHER SYSTEM INSTALLATION 1. Vac/Check connected to tank flush inlet should be located a minimum of 6" above flood rim of highest fixture connected to waste holding tank. In addition, B&B recommends this length of piping not to exceed 6'-8' lineal feet. 2. Connect plumbing line running from discharge side of Vac/Check down to sprayer installed on black water tank. Make connection to sprayer device. a. Plumbing line running from water inlet must be a dedicated line for the Tank Flush System. b. Vac/Check assembly must be plumbed in proper direction of flow & orientation. Incorrect direction of flow will void warranty consideration. SPRAYER INSTALLATION ABS Tank - Glued Application 1. Drill a 1" hole on end or side of waste holding tank, NOT TO EXCEED 2" BELOW TOP CENTER OF TANK. 2. Insert desired ½" x ½" MPT fitting into threaded female connection of sprayer device, then tighten. Avoid excessive torque as this will cause stress & may result in cracking sprayer threads. If necessary, Teflon Tape may be used. Common thread sealants should never be used! 3. Apply a generous bead of 100% silicone sealant (do not substitute) to inside flange of black sprayer device. 4. Orientate black sprayer device with "top" facing up & fasten to tank using (3) #8 x ½ stainless steel screws. DO NOT USE COUNTERSINK HEADED SCREWS DUE TO POTENTIAL CRACKING. Let silicone sealant properly cure before testing. Page 14 of 15

INSTALLATION INSTRUCTIONS SPRAYER INSTALLATION Rotational Molded Tank Spin Weld Application 1. Drill a 1" hole on end or side of waste holding tank, NOT TO EXCEED 2" BELOW TOP CENTER OF TANK. 2. With a router that spins at over 20,000 rpm, insert white/clear sprayer device into special tool/chuck making sure it is well seated. Insert sprayer into 1" hole in tank. 3. Spin with chuck drive & stop when plastic begins to melt and hold for 5 seconds with light pressure to ensure bond. DO NOT USE SEALANT ON SPIN WELD SPRAYER! 4. Insert desired ½" x ½" MPT fitting into threaded female connection, then tighten. Avoid excessive torque as this will cause stress & may result in cracking sprayer threads. If necessary, Teflon Tape may be used. Common thread sealants should never be used! TESTING WATER SYSTEM Follow RVIA Standards and Guidelines when pressure testing water distribution systems. Damage to the Nautilus System as a result of not following RVIA Standard 7.7.2 (Water Distribution System Testing) voids all warranty consideration! TESTING THE FLUSHER SYSTEM 1. Connect a garden hose to water inlet of Flusher System. 2. Open dump valve on tank that Flusher Sprayer is installed. 3. Turn water ON to test system minimum water pressure of 40 psi must be used. *Atmospheric Vacuum Breaker shall not be subject to continuous pressure for more than 12 continuous hours. *It is normal for trapped water between Atmospheric Vacuum Breaker (Vac/Check) and water inlet to exit as garden hose is disconnected. **Important** Make sure faucet is open completely during entire tank flush cycle. Vac/Check is designed to work at water pressure range of 8 125 psi. Water leakage from Vac/Check is likely when water pressure in supply line is under 8 psi. It is normal for a small amount of water to escape Vac/Check as plumbing line for tank flush pressurizes. NOTE: Any parts added to system shall be equivalent of and installed in accordance with IAPMO TSC 27. Page 15 of 15