The Shortwave Reflectance of the Yankee Environmental Systems Hotplate

Similar documents
Pyroelectric Infrared Sensor PIR

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

TESTS OF ADSIL COATING

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

Global Warming and the Hydrological Cycle

Understanding total measurement uncertainty in power meters and detectors

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Dynamic performance of a novel dew point air conditioning for the UK buildings

LIMITS OF CARBON DIOXIDE IN CAUSING GLOBAL WARMING

STUDY ON A FLOOR SUPPLY AIR CONDIGIONING SYSTEM WITH THERMAL ENERGY STORAGE USING GRANULATED PCM

September 11, 2012 Ministry of Economy, Trade and Industry

for room heating Guntis Ruskis Scientific advisers: Aivars Aboltins, Janis Palabinskis

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Understanding Water Use by Plants in a Cloche System - Gardening

Green Roofs Impact on Buildings Cooling Load

A study of radiant cooling for a room with daytime application in tropical climate

Brine Generation Study

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Study on the Effect of Blade Angle on the Performance of a Small Cooling Tower

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

6. GREEN ROOF DESIGN. Figure 6.1: Schematic Design Phase proposal for green roof (SmithGroup). Figure 6.2: Example of a cool roof (fypower.org).

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

An FT-NIR Primer. NR800-A-006

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

HEATING OF AIR BY SOLAR ENERGY

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

Chapter 3 DESIGN OF THE STUDY

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Global Journal of Engineering Science and Research Management

Injection with front ends open at the ESRF

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Laser Collimated Beam Sensor

Reducing energy use, airstream heat gain, and condensate production

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Lecture 7 Water in the Atmosphere

Product data sheet Palas Fidas 200 S

DETECTION AND MONITORING OF ACTIVE FIRES USING REMOTE SENSING TECHNIQUES

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Test One: The Uncontrolled Compartment Fire

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Class 1 laser beam sensor safe for your eyes

Jülich Solar Power Tower System Behavior During Downtime

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

(Refer Slide Time: 00:00:40 min)

solution, due to the partial vapor pressure difference between the air and the desiccant solution. Then, the moisture from the diluted solution is rem

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Class 1 laser beam sensor safe for your eyes

Effect of the Use Pattern on Performance of Heat Pump Water Heater

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

THE EFFECT OF HIGH TEMPERATURE AIR DRYING ON EVAPORATION, RUNNABILITY AND COATED PAPER PROPERTIES. Pertti Heikkilä and Pasi Rajala

Mathematical Simulation of Longan Fruit Drying

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Class 1 laser beam sensor safe for your eyes

Electric radiator tests

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

R&D for the improvement of O&M in CSP plants. Dr. Marcelino Sánchez. - November,

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Solar Drying of Fruits and Vegetables

Systems Engineering Approach to Development of Advanced Residential Buildings

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

Performance Enhancement of Inclined Bubbling Fluidized Bed Paddy Dryer by Design Modification

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Distributed Temperature Sensing

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Thermal Performance Of Low Cost Solar Bamboo Dryer

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Heat Transfer in Evacuated Tubular Solar Collectors

Temperature dependent Components within the Pyroelectric Detector

Transcription:

1 - Introduction The Shortwave Reflectance of the Yankee Environmental Systems Hotplate David Siuta, Jefferson R. Snider and Bujidmaa Borkhuu University of Wyoming September 2010 (Updated September 2017) A Yankee Environmental Systems Hotplate Precipitation Sensor (hereafter the hotplate ) is new type of precipitation gauge. Precipitation intensities reported by the hotplate are derived from measurement of the electrical power needed to maintain the hotplate s upper surface at a constant temperature. Nominally, the plate surface temperature is set at 75 o C (Rasmussen et al., 2010). Other examples of heated constant-temperature meteorological sensors are the devices used to detect cloud water content (King et al., 1978; Korolev et al., 1998). Assuming that the hotplate s heat budget is at steady state, the electrical power supplied to its top plate can be equated to the rates of three heat transfer processes: 1) sensible heat transfer, 2) latent heat transfer (i.e., the component of the electrical power used to melt and evaporate precipitation), and 3) radiative heat transfer both at visible wavelengths (shortwave heating) and infrared wavelengths (longwave cooling). Typically, it is assumed that the net radiative heat transfer term is negligible. If that assumption is valid, then the electrical power minus the sensible heat term is proportional to the latent heat transfer and thus proportional to the precipitation intensity (Rasmussen et al., 2010). We show that this assumption can lead to substantial bias in a hotplate s report of precipitation intensity ( 10%). We also report measurements of the hotplate s reflectance at solar (shortwave) wavelengths and show how the derived reflectance, combined measurement of solar irradiance, can be used to correct a hotplate s biased report of precipitation intensity. 1

Figure 1 shows the top surface of the hotplate; we refer to this as the sensor plate. The sensor plate consists of a horizontal surface, diameter 0.13 m, and has three concentric rings extending vertically from its surface. Not seen in Figure 1 is the lower hotplate surface, here referred to as the reference plate. The reference plate is a mirror image of the sensor plate. Figure 1 The Yankee Environmental Systems Hotplate Precipitation Sensor (http://www.yesinc.com/products/data/tps3100/index.html). A parameter used in this analysis is the surface area of the upper plate. Sensible heat energy is transported across an area equal to the sum of the plate s horizontal surface area (0.013 m 2 ) plus the vertical surface area of the three rings (0.005 m 2 ). From the perspective of solar irradiance, the active surface area is approximately 0.002 m 2 smaller than the sum of horizontal and vertical areas. Throughout this analysis we approximate the effective hotplate surface area as the sum of horizontal and vertical areas ( A hp =0.018 m 2 ) and apply this surface area regardless of the specific process being analyzed (solar heating, sensible heating, etc.). 2

The hotplate microprocessor reports sensor data every second. Three of these measurements are used in this report: 1) the electrical power supplied to the sensor plate, 2) ambient temperature, and 3) wind speed. The latter is derived from values of ambient temperature and the electrical power supplied to the reference (bottom) plate (Rasmussen et al., 2010). Values of wind speed, and the ambient temperature, are used to derive the rate of sensible heat transfer from the sensor plate (Borkhuu, 2009). The derived sensible heat transfer rate is subtracted from the sensor plate electrical power and a power difference is formulated. An example of this is shown in Figure 2. The figure shows twelve hours of measurements made during operation of the hotplate on a 25 m tower located in the Medicine Bow Mountains of southeastern Wyoming. The Figures 2b-2c show the sensor plate electrical power and wind speed measurements; Figure 2a has measurements from collocated longwave and shortwave radiation sensors, and Figure 2d has the power difference (i.e., electrical power supplied to sensor plate minus the sensible heat transfer rate). The twelve-hour interval shown in Figure 2 was free of both clouds and precipitation. This is evident from the smooth data traces in Figure 2a and from the amplitude of the daytime shortwave flux (local noon is at 18:00 UTC). To ease comparison of the radiative and hotplate data, Figure 2b presents the electrical power supplied to the sensor plate divided by scaling converts the electrical power to an energy flux. The correlation seen between the A hp ; this electrical power (Figure 2b) and wind speed (Figure 2c) is an indication of the dominance of the sensible heat term in the plate s energy budget. The departure from zero seen in Figure 2d has two important implications for the hotplate s measurement of precipitation. During daytime, when the hotplate is absorbing a fraction of the incident shortwave radiation, it is evident that the power difference is negative. 3

On days with precipitation, this negative difference (residual) leads to underestimation of the hotplate-reported precipitation intensity. Conversely, the positive difference during nighttime can alias as precipitation. The magnitude of the nighttime and daytime residuals - approximately 100 and 200 W m -2 in Figure 2d - translate to a precipitation bias equal to 0.1 mm/hr (overestimate at night) and 0.2 mm/hr (underestimate during day). Because instantaneous wintertime precipitation intensities in southeastern Wyoming seldom exceed 2 mm/hr (Wolfe and Snider, 2010), these plus and minus residuals are indicative of significant (5% to 10%) uncertainty in determinations of wintertime precipitation reported by the hotplate. This report documents simultaneous measurements of solar irradiance, with measurements of hotplate sensor plate power, wind speed and temperature. In our analysis we derive the hotplate s shortwave reflectance. Our measurements and analysis are described in the next section. In the summary, we compare our reflectance values to values for aluminum reported in the literature. 4

Figure 2 (a) Time series of AmeriFlux downwelling longwave and shortwave radiation measurements, (b) electrical power supplied to the sensor plate divided by A hp, (c) wind speed derived from electrical power supplied to the reference plate, temperature and wind speed, (d) difference between electrical power supplied to the sensor plate and the derived sensible heat transfer rate (Borkhuu, 2009), divided by A hp. Measurements are from 20070414, acquired 25 m above ground level on the AmeriFlux tower located in the Medicine Bow Mountains of southeastern Wyoming. 5

2 - Measurements Assuming steady state and no precipitation, and ignoring longwave radiative terms, the sensor plate s energy balance equation is P SH Ahp I (1 R ), (1) where, P is the electrical power supplied to the sensor plate, SH is the sensor plate s sensible heat term (Borkhuu, 2009), I is the solar irradiance and R is the senor plate s shortwave reflectance. In these experiments, the hotplate was either shaded from shortwave radiation, or illuminated by it. Equation 1 is formulated differently for the shaded and illuminated situations, here indicated by either a subscript s or i, respectively: P i SH A I (1 R ) (2) i hp Ps SH s (3) Measurements of I, combined with hotplate measurements of P i, P s and derived values of SH s and SH i (Borkhuu, 2009), allow the reflectance to be calculated as R P P ( SH SH ) s i s i 1 (4) I Ahp The direct normal component of the solar irradiance ( I N, W m -2 ) was measured with an Eppley-Angstrom Compensation Pyrheliometer (Eppley Laboratory, 1976). During the experiments, paired measurements of I N were obtained from the two channels of the pyrheliometer. These were derived via the pyheliometer s calibration equation, where I i 4.27x10 3 (5) N 2 i the compensation current in ampere. The time of the pyrheliometer measurement and an ephemeris (http://solardat.uoregon.edu/solarpositioncalculator.html) were used to derive the 6

solar zenith angle ( ). Since the hotplate was oriented horizontally, the direct horizontal component of the irradiance appears in Equations 1, 2 and 4. The direct horizontal component was derived from values of I N (Equation 5) and the solar zenith angle. I I cos (6) N All measurements were made inside an air conditioned office (temperature = 23 o C); sunlight entered the office through a south-facing window. The experiments consist of three steps: 1) the hotplate is turned on and allowed to warm up for 15 minutes while illuminated by sunlight, 2) hotplate measurements are made for 10 minutes (illuminated data) and during that time measurements were made with the pyrheliometer, and 3) the shades are drawn and hotplate measurements are made for 10 minutes (shaded data). Table 1 presents the pyrheliometer measurements. Because the two experiments were conducted during wintertime, well before solar noon, the solar zenith angle was relatively large. Neither day had significant cloud cover, but since the path length through the atmosphere was large owing to the large zenith angle, and because of attenuation by the office window, the irradiances in the last three columns of Table 1 (~100 W m -2 ) are substantially smaller than unattenuated value of the direct horizontal component ( ~700 W m -2 ). Figure 3 has the hotplate data from one of the two experiments. In addition to a time series of electrical power (Figure 3d), the temperature (Figure 3a), wind speed (Figure 3b), and the sensible heat (Figure 3c) time series are illustrated. The three parts of the experiment are evident with the illuminated and shaded intervals starting at 16:00 and 16:10, respectively (all times are UTC, or local time +7 hr). During the illuminated interval the temperature increases and the sensible heat decreases slightly; this behavior is expected because the rate of sensible heat transfer, as formulated in Borkhuu (2009), decreases with decreasing temperature difference 7

between the hotplate and its surroundings. Electrical power supplied to the hotplate (Figure 3d) is seen to shift from an average value of 9.42 W (illuminated) to 10.15 W (shaded). This increase is expected because the solar input is stopped at 16:10. Finally, the Figure 3b (hotplate windspeed) is seen to be 0 m/s for the duration of this experiment. Evidently, ventilation due to the building s heating system produced a velocity which was undetectable by the hotplate. Table 2 summarizes the two experiments, including the direct horizontal irradiance and the time-averaged hotplate measurements from Figure 3 (electrical power and sensible heat, for both the illuminated and shaded intervals). The final column of Table 2 has the reflectance values derived using Equation 4. 8

Table 1 Measurements from the pyrheliometer Date Time (MST) Solar Zenith Angle ( o ) Left Current (A) Right Current (A) Direct Normal Irradiance (Left) (W/m 2 ) Direct Normal Irradiance (Right) (W/m 2 ) Direct Horizontal Irradiance (Left) (W/m 2 ) Direct Horizontal Irradiance (Right) (W/m 2 ) Averaged Direct Horizontal Irradiance (W/m 2 ) 20100203 10:51 61.0 0.217 0.214 201 196 97 95 96 20100312 9:20 59.3 0.225 0.222 216 210 110 107 109 Table 2 - Measurements from the pyrheliometer and hotplate Date Averaged Direct Horizontal Irradiance (W/m 2 ) Hotplate Electrical Power Illuminated (W) Hotplate Electrical Power Shaded (W) Hotplate Sensible Heat Illuminated (W) Hotplate Sensible Heat Shaded (W) Hotplate Reflectance 20100203 96 9.82 10.40 10.35 10.34 0.66 20100312 109 9.42 10.15 10.25 10.21 0.61 9

Figure 3 - (a) temperature, (b) wind speed derived from the electrical power supplied to the reference plate, temperature and wind speed, (c) sensible heat term for the sensor plate derived from temperature and wind speed via the algorithm of Borkhuu (2009), (d) electrical power supplied to the sensor plate. Measurements made on 20100312 in an office in the College of Engineering and Applied Science at the University of Wyoming. Data is acquired at 1 Hz. Plotted values are resampled at 0.1 Hz. 10

Discussion and Conclusion: We report two experimental determinations of the fraction of solar energy reflected by the upward-oriented surface of the Yankee Environmental Systems Hotplate Precipitation Sensor. Our two determinations of the reflectance are 0.66 and 0.61 and their average is 0.63. This average is slightly smaller than the value reported for polished aluminum reflecting incandescent light (0.69; Weast, 1975) and significantly smaller than the value for vacuumdeposited aluminum at visible wavelengths (0.97; Hass, 1955). As can be seen from Figure 1 the hotplate surface is not polished. Furthermore, since the reflectance of vacuum-deposited metal is significantly larger than that of a polished metal surface (Hass, 1955), our reflectance determination is qualitatively consistent and perhaps even quantitatively consistent with values reported in the literature. Repeated assessment of the reflectance is needed to specify the precision of the measurement. An uncertainty analysis, and comparison of the irradiance measurement to a reference standard, are needed to gauge the absolute accuracy of the reflectance. 11

References Borkhuu, B., Snowfall at a High Elevation Site: Comparisons of Six Measurement Techniques, M.S. Thesis, Department of Atmospheric Science, University of Wyoming, 2009 Epply Laboratory., The Epply-Angstrom Compensation Pyrheliometer and Associated D.C. Electrical Instrumentation, 1976 Hass, G., Filmed surfaces for reflecting optics, Journal of the Optical Society of America, 945-952, 1955 King, W.D., D.A.Parkin, R.J.Handsworth, A hot-wire liquid water device having fully calculable response characteristics, J. Appl. Meteor., 17, 1809-1813, 1978 Korolev, A.V., J.W.Strapp, G.A.Isaac, A.N.Nevzorov, The Nevzorov airborne hot-wire LWC TWC probe: Principle of operation and performance characteristics, J. Atmos. Oceanic Tech., 15, 1495-1510, 1998 Rasmussen, R., Hallett, J., Purcell, R., Landolt, S.D., Cole, J., The hotplate snow gauge, Submitted to Journal of Applied Meteorology and Climatology, 2010 Weast, R.C., Ed., Handbook of Chemistry and Physics, 56 th ed, Chemical Rubber Company, Cleaveland, Ohio, 1975 Wolfe, J.P., and J.R.Snider, A reflectivity/snowrate relationship for S-band radar at a highaltitude Site, submitted to Journal of Applied Meteorology and Climatology, 2010 12