Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

Similar documents
Is it time to replace YOUR DUCTED SYSTEM?

A/C Cooling Load calculation and measurement

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

- Murdoch University, Western Australia.

An Efficient Cold Store Facility

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

Water Jet Nozzle to reduce the operation cost in Air Conditioning unit

Optimisation of cooling coil performance during operation stage for improved humidity control

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Split Type Air Conditioners

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

APPLICATION OF HEAT PUMP SYSTEM FOR ECO-FRIENDLY VEHICLES

Inverter Ducted Air Conditioners


AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

All DC Inverter Multi VRF

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

Transcritical CO2 Bottle Cooler Development

Heat Pumps for Swimming Pools extend the season or swim year round

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

Inverter High Wall MSZ-GE Series

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

You will investigate the electrical consumption in your home over the course of TWO days (48 hour period).

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

HI-WALL SPLIT SYSTEMS

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

Drink Showcase Equipped with Inverter Freezer

Inverter Wall Mounted Series

eceee 2017 summer study on energy efficiency

EN aquatech.piovan.com

Presented By: John Dolan, P.E.

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Public Services Building 155 N First Avenue Hillsboro, OR March 2012

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

USER MANUAL TPS-M5/M55/M555

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

DEVELOPMENT OF A KILN DRIED WOOD SYSTEM USING HEAT PUMP TECHNOLOGY

Designing Energy Efficient Outdoor Air Systems

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Air Conditioners. Summer

CHOOSING A COOLING SYSTEM

Armstrong Cool-Fog Systems

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Local air conditioner

Hansol Hi Wall Inverter Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

Attractive. Selling a higher form. (up)selling Guide. Infinity 18VS heat pump & Infinity 19VS air conditioner

Research on Waste Heat Recovery System for Residential Gas Engine-Driven Heat Pump

THE ULTIMATE HEATING + COOLING GUIDE PCRAU0318

September 11, 2012 Ministry of Economy, Trade and Industry

MRI Advanced Cooling System

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Inverter Ducted Air Conditioners

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

. Creating Maximum Comfort

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

Pressure Enthalpy Charts

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Global Solutions for Ammonia Industrial Refrigeration

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Split System Air Conditioning

Eco Compact Series GAS HEAT PUMP

Energy Use in Refrigeration Systems

DESIGN & TECHNICAL MANUAL

WATE R -C OOLE D WATE R C H ILLE R S

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Dehumidification: Energy Efficiency Comparisons

A Comparison Between Refrigerants Used In Air Conditioning

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

we care about Better Air

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Digitemp. Beyond air conditioning.

Better air. Leading the new era in air conditioning Inverter System

,Chaojian He6, f. School of Guangxi University, Nanning , China.

Universal Applications

Energy Recovery Ventilation

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

MODEL: DC10RCDH / DC12RCDH

Precision air conditioners with inverter technology for stable room conditions

Agam Greenhouse Energy Systems Ltd.

Japanese market and issue of Heat Pump Kenji Matsuda

Energy consumption storage facilities examined in ICE-E

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

PCRAU0510. the. ultimate. heating and cooling guide

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Reverse Cycle Portable Air Conditioner with Dehumidifier

Aeration vs NAD vs NAD+heating vs Heated Air Drying

Parilla Thermal Storage Project Case Study. May Page 1 of 11

Transcription:

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM 13 th May 2017 0

1

Portion of Inverter Residential Air Conditioners Worldwide (2015) and in Vietnam (Mar 2017)

What is "Inverter"? 3

Mechanism of Air Conditioner What convey the refrigerant? Compressor is the pump to deliver the refrigerant between the indoor unit and the outdoor unit. Refrigerant Heat Indoor Air Ambient Air 30 Refrigerant Compressor 4 5 4

Mechanism of Air Conditioner What convey the refrigerant? Compressor controls the temperature of refrigerant which receives the heat from the air. Daikin is a world leading company who manufactures not only air conditioner but also compressor. 5

Mechanism of Air Conditioner About control system of compressor 2 types of motor for compressor Non-Inverter Inverter Non-Inverter ON/OFF control ONLY Inverter enable to control flexibly 6

What is Inverter? The difference between Non-INV and INV A/C WITHOUT INVERTER Repeating hard training and rest brings big exhaustion of strength and the load to body is big. A/C WITH INVERTER If the runner can keep an appropriate load under the advise from trainer, the runner would be able to keep running efficiently 7

ROOM TEMP. ( ) ROOM TEMP. ( ) What is Inverter? The difference between Non-INV and INV NON-INVERTER A/C without inverter brings bad efficiency. Ex.) unstable room temp., high power consumption, etc INVERTER A/C with inverter can actualize energy saving comfortably, because it can accurately adjust room temp. Large difference Small difference TIME TIME 8

What is Inverter? Operation pattern for Non-Inverter (setting temp./capacity/power consumption) Waste of power consumption 9

What is Inverter? Operation pattern for Inverter (setting temp./capacity/power consumption) Waste power consumption 10

Power consumption efficiency [kwh/kwh] What is Inverter? Cooling capacity and energy saving Fuel consumption [km/l] 0 50 100 [km/h] Speed Non Inverter Air con Inverter Air con 0 50 100 [%] Cooling capacity 11

Cooling load (w) Cooling load (w) Cooling load (w) Cooling load (w) Cooling load (w) Cooling load (w) What is Inverter? Cooling capacity and energy saving Air conditioning loads is changing by hour during a day in each country. Indonesia : Jakarta Malaysia : Kuala Lumpur Vietnam : Ho Chi Minh ~2400W ~3000W ~2400W Time Time Time Thailand : Bangkok Vietnam : Hanoi Philippines : Manila ~2400W Time ~2400W ~2600W Time Time <Calculation conditions> - 3 people stay (all day) - Natural ventilation - With windows (with curtains) - With room lamps (lighting rates are set per hour) - With heat-generating devices (such as TV) - Sleep hours: 24:00-6:00 - Use ambient temp. data for the day in each city with setting AHRAE Design Ambient Temp. as peak ambient temp. - Preset room temp.: Design conditions in each city * Annual A/C loads of rooms to be cooled by average representative models (calculated with Daikin s software DACCS-HKG) 12

What is Inverter? Cooling capacity and energy saving for Inverter Enough capacity Higher efficiency Higher efficiency Necessary Cooling Capacity (Cooling load) Morning Noon~After noon Evening Night Low~Mid High~Too High High~Mid Low~Too Low Air-con Cooling Capacity 50~80% 100~120% 80~60% 50~20% Power Consumption Efficiency Mid Low Mid High Lower power consumption efficiency, but enough cooling Higher power consumption efficiency, with lower capacity 13

What is Inverter? Cooling capacity and energy saving for Non Inverter Not enough capacity Low efficiency Low efficiency Necessary Cooling Capacity (Cooling load) Air-con Cooling Capacity Around 100% with often ON OFF Morning Noon~After noon Evening Night Low~Mid High~Too High High~Mid Low~Too Low Around 100% sometime with not enough capacity Around 100% with often ON OFF Around 100% with always ON OFF Power Consumption Efficiency Low Low Low Too Low Comparative higher power consumption efficiency, but not enough cooling Lower power consumption efficiency, with frequent ON/OFF 14

What is Inverter? 15

Energy Saving through Next Generation Refrigerant 16

Properties of HFC-32 Potential of Refrigeration capacity :1.6 times of R410A Ozone Protection Energy resources P - h Chart (R22/R410A/R32) Climate Change Peak Load 3100 Safety 2300 Lower pressure loss, when capacity is same, leads to thinner piping diameter Higher coefficient of heat transfer compared to R410A Charge volume reduction Enthalpy Large kj/kg Enthalpy/Kg totally 30% reduction against R410A 17

Converting from R-410A to HFC-32 would reduce Global Warming Impact in 2030 by approx. 800 million tons-co2

Energy Saving in Practical Use (Humidity Control) 19

Energy Saving Impact by Temperature Setting setting temperature :1, electricity consumption :max. approx.10% Example: In case a set temperature is raised from 27 to 28. Energy Saving (Electricity Reduction) Annual Impact CO2 Reduction 30.24 kwh 10.6 kg Calculation Condition In case air conditioner s (2.2 kw) set temperature for cooling is raised from 27 to 28 at the time the outside temperature is at 31. (operating time: 9 hours / day) Source: The Energy Conservation Center, Japan Estimation under the usage in summer in Japan However, comfort may decrease as temperature rises 20

Room temperature ( ) Provide Comfort by Humidity Control Comfort Temperature only, Comfort = Temperature & Humidity Combinations of Humidity and Temperature Comparison of sensible temperature by humidity 30 Relatively humid 28 80% 0.25m/s 28 50% 0.25m/s 10 low Relatively dry Humidity Combination of humidity and temperature to reach comfort level. High temperature: Dry Low temperature: Humid high Due to high humidity, feel uncomfortable, and hot and humid. If humidity decreases, feel comfortable even though temperature is high. Survey by Daikin Industries Ltd. The above images are based on the estimation. 21

Temperature & Humidity Condition and Comfort The proportion of those who felt comfortable increases as the humidity lowers even under high temperature. Percentage of those who felt comfortable (%) 100 20 25.9 24.9 26.5 -RH15% = +0.5 RH 65-85% RH 45-55% 60 you can get comfort (coolness) RH 15-35% by lower humidity even under higher temperature 70 80 90 Temperature ( ) (Rohles, 1975) Feel more comfortable under the environment with the humidity of around 50% than with the humidity of around 70% even though the temperature is 1 higher. ( humidity of 20% is equivalent to the sensible temperature of 1.) 22

Comparison of Humidity Control In practical situations, NON inverter operate with many start-stop operation, so increase in humidity is often seen by the stop, Inverter can operate with reducing the start-stop operation by low capacity operation (compressor low rotation), there is an advantage in comfort. Non-Inverter operation data Inverter operation data Humidity is frequently increasing Not been able to dehumidification Increase in humidity is controlled Indoor RH 70% Indoor temp. 26 Non-Inverter cannot create a comfortable environment well Indoor unit discharge air temp. Compressor ON Start-stop operation Continuous operation Compressor OFF Outdoor temp. 29~31 Outdoor temp. 29~32 Survey by Daikin Industries Ltd. 23

New technology of Humidity control Air Conditioners stably operate at around set temperature about 80% of their operation time in practical situation. Operation in summer: Comparison of operating time by air conditioner loads and ambient temperatures (Daikin data: N=261 nationwide) Air Conditioner Operating Load Research period: July 16, 2013 September 15, 2013 High Load Area of circle shows utilization time Normal Load Stable Operation Focus on Stable Operation (low capacity operation) 80% of operation time Ambient Temperature ( ) Case in western Japan 24

New technology of Humidity control Have you experienced such situation? Cooling starts at 28 A/C turns on and off Repeatedly feel cold and hot in turn, and temperature cannot be adjusted appropriately. A/C stops automatically Lower set temperature as feel hot After reaching set temperature, A/C turns off and feel hot. If set temperature is lowered, feel cold. Challenge 1: Temperature does not stabilize After reaching set temperature, A/C repeatedly turns on and off and room temperature fluctuate because A/C Challenge 2: Hot & High Humidity After reaching set temperature, feel hot and humid because A/C becomes unable to dehumidify and room temperature rises. Temperature and Humidity change during operation (Conventional Operation) Start operation Temperature / Humidity Challenge 1 Challenge 2 Humidity Temperature Time If set temperature is lowered because of feeling hot Challenge 3: Higher Electricity Bill & Not Good for Health If set temperature is lowered to seek comfort, extra electricity may be incurred. Moreover, too much air cooling is not good for health. 25

New technology of Humidity control 1Not feel hot and humid because dehumidification is sufficient Temperature change after starting operation (image) Current Feel hot and humid because humidity increases after temperature stabilizes. New Start operation Humidity Reaching set temperature Hot & Humid Humidity of current operation Humidity of New operation Comfortable humidity can maintain because dehumidification can be done even after temperature stabilizes. Not feel hot and humid because comfortable humidity can maintain. Time 2Feel comfortable even if set temperature is relatively high as not feel hot and humid. Current Lower set temperature because dehumidification is not sufficient even after reaching the original set temperature. New Feel comfortable even if set temperature is relatively high because dehumidification at set temperature is sufficient. In case the temperature of room with 70 humidity from 29 to 28 Current Cooling New Cooling 28 80% Feel hot 28 50% Comfortable Lower set temperature as feel hot. Comfort was evaluated with PMV value. Same Comfort Level 27 80% Comfortable New technology can provide the same comfort level even if set temperature is 1 higher. 26

New technology of Humidity control <Summary> NEW humidity control 1 A/C can control temperature with ±0.5 accuracy. Steadily maintain temperature. Remote control can also set by 0.5. NEW humidity control 2 Temperature change after starting operation (image) Temperature / Humidity Start operation Temperature of new technology Humidity of current operation Humidity of new technology Temperature of current operation Time A/C can dehumidify the air while operating cooling mode even after the temperature stabilizes after reaching set temperature. As A/C can maintain appropriate humidity, feel comfortable instead of feel hot and humid even though set temperature is relatively higher. Temperature and Humidity are Stable 27

Features of new technology of DAIKIN product 28

Flagship Model Urusara7 The new flagship model has 7 features, made possible by DAIKIN s original technology 2 Next- Generation Refrigerant 1 Energy Saving 3 Humidity Control 4 5 Airflow Control Air Purification 6 Automatic Cleaning 7 Designed in Japan 29

Thank you!! 30