Product Features Technical Training 2007

Similar documents
Applica. First Edition uly 2005

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

2. FEATURES. Gold aluminum fin is offered as standard material of the condenser heat exchanger of this series of chiller.

Service Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november

Operating Functions Temperature Parameters

USER'S OPERATING INSTRUCTIONS

SERVICE MANUAL. Inverter Wall Mounted Single Split. MODELS Cooling Only. Heatpump SM-5WM-Y-NA-B1

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

Container Refrigeration

Part 3 Troubleshooting

REMOTE CONTROL FOR CHILLER MYCHILLER

Safety & Installation Instructions

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

INSTALLATION & OPERATION MANUAL

Troubleshooting & Reference

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Rev B, 9/2/2009. Kodiak Chiller Overview

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Chilled Water System Solution

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

Smart Temp. Model

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX30

User Manual. Dryer Controller M720

Dryer Controller M720

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

Inverter Wall Mounted Series

T-32-TS Touchscreen Thermostat. Installation Manual

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Product Manual SZ1009

Fast Track Troubleshooting

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

KSIM20912-H216 KSIM30912-H216 KSIM40912-H216

Air Cooled Module Water Chiller

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

NO. F ISSUED: JUN. 18, 2008 REVISED: JUN. 17, 2011 HOSHIZAKI SELF-CONTAINED CRESCENT CUBER KM-100A KM-125A MODEL SERVICE MANUAL

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Product Manual SZ1022/SZ1031/SZ1035/

AC&R Controller RWR Basic Documentation VR2002 for water to water heat pump units

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Ice Rink (Single and Dual Configurations) Custom Control Features

Fast Track Troubleshooting

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

AQUASNAP JUNIOR 30RHV

Wired Controller XK60

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Ductless Split Air Conditioner

Fast Track Troubleshooting

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

Chilled Water System. All Product Brochure

RSMV Technical Guide

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

GeneSys Air-Cooled Screw Compressor Chiller

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MAC-120HE-03 Air-Cooled Chiller

Ductless Split Air Conditioner

AIR COOLED MINI CHILLER

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

MSRW MINI SERIES. Modular Water Cooled Scroll Chiller MSRW075 MSRW085 Nominal Capacity 73 to 1312 kw(r) Issue: 2.0 Date 07/08

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Comfort System T-21-P Touchscreen Thermostat Installation Manual

HT V2 HT Split

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

Transcription:

Product Features

Product Features Less foot print occupied Less space required.

Product Features Made of AISI 316 Stainless Steel High heat exchange efficiency

Product Features New Technology BPHE True Dual Circuits Conventional Back to Back Circuits BPHE Primary Circuit 1 Primary Circuit 2 Secondary Circuit Inverter Mini Chiller True Dual Circuits BPHE Primary Circuit 1 Primary Circuit 2

Product Features Support up to 50 chiller and 120 fan coil units through chiller bus

Product Features Chiller Bus A network up to 50 chillers Operation control on chillers done through microprocessor controller. Additional chiller can be added on by just extend the water piping. Water Out Water In Up to 50 Chillers

Product Features Can be done through Chiller Control Panel User friendly and versatile controls Main menu includes: Operation Timer Display Setting Alarm Whole system configuration Unique system configuration

Product Features 1. Less Start & Stop 3. Precise Temperature Control 2. Fast Cooling/ Heating 4. Low Starting Surge Running current Conventional air conditioner: High starting current Frequent on/off cycle Inverter air conditioner: Low starting current Smooth operation Hours of operation

Product Features Conventional System Inverter System

Product Features High & Low Pressure Switches Anti Freeze Protection Sensor Discharge Temperature Sensor Over Pressure Relief Valve Water Pressure Differential Switch Anti Freeze Heater on BPHE Compressor, Water Pump Overload Protector Back To Content

Schematic Diagram & Components

Schematic diagram 5ACV100CR Disch Temp 1 (Disch Comp 1) Inv Comp HP1 Suct Temp (Suction) Acc LP1 Cond In Temp 1 (Condenser) 4WV BPHE Out Temp (BPHE Out) Condenser Coil 1 BPHE In Temp (BPHE In) Cond Out Temp 1 (Def Comp 1) Liq Rvr Filter Drier EXV O/A Temp (Outdoor Air) Pump Disch Temp 2 (Disch Comp 2) Std Comp HP2 Acc LP2 4WV BPHE Condenser Coil 2 EWT (Water In) LWT (Water Out) Check valve Cond Out Temp 2 (Def Comp 2) FS Cooling Cap Tube Liq Rvr Heating Cap Tube Filter Drier Summary Pages Screen 3 Display Menu Defrost Sensor Display Menu Inverter Chiller Display Menu Discharge Sensor Check valve

Components Fan guards Coil guards Variable speed fan motors (100%, 70% & 50%) Heat exchangers with gold fin as standard True dual circuits BPHE (Brazed plate heat exchanger) Control box assembly Expansion tank ( 8L) Water pump

Components Unidirectional bridge diode IPM board (Intelligent power module) 3 phase rectifier bridge diode Fan capacitors Power board EMI filter Capacitor board PFC capacitor (Power factor correction) Main board Magnetic contactors

Components For Model 55, 75, 100 & 135 For Model 30

Components To convert rectified DC current +500VDC to respective desired voltages 12VDC relay MCU +5VDC IPM +15VDC Ensure stability of above voltages within power supply voltage fluctuation range (304480 VAC) Over voltage feedback Output short circuit protection

Components

Components

Components High pressure switch (NC) 600 psi open, 480psi close. EXV (Electronics expansion valve Low pressure switch (NC) 18 psi open, 28 psi close. Chiller panel controller Differential pressure switch 4 Way valve Over pressure relief valve Anti freeze heater on BPHE Fixed speed scroll compressor (R410A) Pump OLP (overload protector) Compressor OLP (overload protector) Variable drive system compartment Fixed drive system compartment Variable speed scroll compressor (R410A)

Installation & Commissioning

Installation & Commissioning Unit Handling Unit Placement Maintenance Access Water Piping & Fitting Power Supply & Electrical Connection Preliminary Checking before Startup General Control Flow Chart

Installation & Commissioning 5ACV 100/135/210 CR

Installation & Commissioning Air Cooled Chiller are cooled by air, space restriction will reduces the air flow, decrease the cooling capacity, increase the power input and, in come cases, prevent the unit from operating because of an excess of condensation pressure. 5ACV equipped with propeller fan, which doesn t need ductwork on fan outlet. Direct effect of the wind on the discharge surface of the fan should be avoided. Enough clearance around the unit for maintenance works.

Installation & Commissioning Minimum clearances 5ACV30/55/75CR 5ACV100/135/210CR

Installation & Commissioning

Installation & Commissioning 5ACV 30 / 55 / 75 CR

Installation & Commissioning 5ACV 100 / 135 CR

Installation & Commissioning 5ACV 210 CR

Installation & Commissioning! Install piping with minimum bends and changes in elevation to minimize pressure drop. Consider the following: Vibration eliminators to reduce vibration and noise transmission to the building. Shut off valves to isolate the unit from the piping system during unit servicing. Manual or automatic air vent valves at the highest points of the chilled water piping. A means of maintaining adequate system water pressure (expansion tank or regulating valve) Temperature and pressure indicators located at the unit to air in unit servicing.

Installation & Commissioning! Water connection could be damaged by an excessive stress when screwing them. Use a second spanner to compensate the stress of tightening. Safety differential pressure switch is used to ensure adequate water flow to evaporator before starting up the unit. Balancing valve to regulate the amount of water flow rate through the unit.! It is mandatory to install a strainer at the inlet of the unit.

Installation & Commissioning Recommended Piping Connection

Installation & Commissioning Recommended Fuses & Cable Size Model 5ACV100CR 5ACV135CR 5ACV210CR Voltage Range ** 380 415 / 3 / 50 Recommended Fuse (A) * 40 60 100 Power Supply Cable Size (mm 2 ) * 10 10 10 Number of Conductor 3 5 5 Interconnection Cable Size (mm 2 ) * 1.5 1.5 1.5 Model 5ACV30CR 5ACV55CR 5ACV75CR Voltage Range ** 230 / 1 / 50 415 / 3 / 50 415 / 3 / 50 Recommended Fuse (A) * 36 25 10 Power Supply Cable Size (mm 2 ) * 10 10 10 Number of Conductor 3 5 5 Interconnection Cable Size (mm 2 ) * 1.5 1.5 1.5 IMPORTANT: The figures shown in the table are for information purpose only. They should be checked and selected to comply with local/national codes of regulation. This is also subject to the type of installation and conduction used. * The appropriate voltage range should be checked with label data on the unit.

Installation & Commissioning!!! Before carrying out any operations on the electrical system, make sure that the unit is deenergized. It is important that the appliance is grounded. Before connecting the power supply lines, check that the available voltage value does not exceed the range specified in the electrical data being provided in Installation Manual.! It s recommended to check the correct sequence of the 3 supply phases RST before the unit start up.

Installation & Commissioning Check the power supply and grounding cable. Check that any voltage and phase variation in the power supply does not exceed the prefixed thresholds. Check that components of the external water circuit have been installed properly, and according to the manufacturer s instructions. Check that the filling of the hydraulic circuits, and make sure that the fluid circulation is correct, without any trace of leaks and air bubbles. Check that the direction of rotation of the pumps is correct. Adjust the liquid distribution network in such a way that the flow rate is within the specified range. Check that the water quality is up to the specification.

Installation & Commissioning Start No System On? Stop Inverter Comp Yes Yes No Clash between current & selected mode of operation? 60s Cooling? No Heating? No Stop pump Yes Yes Cooling mode Heating mode

Installation & Commissioning Cooling Mode Control Flow Chart Start ΔT = Actual Entering water temp Cooling water temp set point Pump on No No Yes Pump on for >3 min? ΔT > 2 C? No ΔT < 2 C for > 180s? Yes Frequency & EXV opening adjustment No No Yes Yes Inverter Comp Off? ΔT > 2 C? Stop Inverter Comp Yes 5s Shut Inverter 4WV & start Inverter O/Fan 30s Start Inverter Comp Return

Installation & Commissioning Heating Mode Control Flow Chart Start ΔT = Heating water temp set point Actual Entering water temp Pump on No No Yes Pump on for >3 min? ΔT > 2 C? No ΔT < 2 C for > 180s? Yes Frequency & EXV opening adjustment No No Yes Yes Inverter Comp Off? ΔT > 2 C? Stop Inverter Comp Yes 5s 30s Shut Inverter 4WV & start Inverter O/Fan Start Inverter Comp Return Back To Content

Self Diagnosis & Troubleshooting

Self Diagnosis & Troubleshooting Error Code Error Display Error Description Reset Control Measure (default) Pump System 1 System 2 (Variable Drive) (Fixed Drive) Comp Fan Comp Fan Phase Missing Phase Missing Manual Phase Seq Error Wrong phase Sequencing Manual Memory Error EEPROM read/write error Auto IPM Error IPM overcurrent or over heat Auto Continue.

Self Diagnosis & Troubleshooting Error Code Error Display Error Description Reset Control Measure (default) Pump System 1 System 2 (Variable Drive) (Fixed Drive) Comp Fan Comp Fan Entering Water Sensor Open/Short BPHE water in sensor error Auto Leaving Water Sensor Open/Short BPHE water out sensor error Auto VHx inlet Temp sensor Open/Short BPHE refrigerant in sensor error Auto VHx outlet Temp sensor Open/Short BPHE refrigerant out sensor error Auto Coil 1 inlet Temp Open/Short Coil in system 1 sensor error Auto Outdoor Air Sensor Open/Short Ambient Temp sensor error Auto Continue.

Self Diagnosis & Troubleshooting Error Code Error Display Error Description Reset Control Measure (default) Pump System 1 System 2 (Variable Drive) (Fixed Drive) Comp Fan Comp Fan Water Flow Error Cv Contact opened Manual Cool Mode Antifreeze Leaving water temp too low Auto Pump overload Pump OLP opened Auto Comp 1 Overload Comp 1 Overload Auto Comp 2 Overload Comp 1 Overload Auto Continue.

Self Diagnosis & Troubleshooting Error Code Error Display Error Description Reset Control Measure (default) Pump System 1 System 2 (Variable Drive) (Fixed Drive) Comp Fan Comp Fan Comp 1 Discharge Overheat Comp 1 discharge Overheat Auto Comp 1 Defrost Sensor Open/Short Coil Out system 1 sensor error Auto Comp 1 Suct Sensor Open/Short Suction comp system 1 sensor error Auto Comp 1 Discharge Sensor Open/Short Discharge Comp system 1 sensor error Auto Comp 2 Defrost sensor Open/Short Coil out system 2 sensor error Auto Comp 2 Discharge Sensor Open/Short/Overheat Discharge comp system 2 sensor error Auto Continue.

Self Diagnosis & Troubleshooting Error Code Error Display Error Description Reset Control Measure (default) Pump System 1 System 2 (Variable Drive) (Fixed Drive) Comp Fan Comp Fan OV/UN Voltage Comp. High Voltage (>490V) <460V, Auto OV/UN Voltage Comp. Low Voltage (<310V) >340V, Auto High Pressure 1 System 1 high pressure Auto Low Pressure 1 System 1 low pressure Auto High Pressure 2 System 2 high pressure Auto Low Pressure 2 System 2 low pressure Auto

Self Diagnosis & Troubleshooting 1. No response after poweron No response Yes Is main board LED light? Yes Check setting & operating condition Is connection IPM and Main Board OK? Yes Main Board or IPM Board Faulty No No Is R,S,T Input voltage normal? No Check Input power supply vac Connection Wire or Connector Faulty Rectifier Yes Is Power Board OK? No Change Power Board Power Board Main Board IPM

Self Diagnosis & Troubleshooting 2. LED on main board normal, but no output. LED lighted, No output Is Setting Parameter ok? No Change the Setting Parameter Yes Is Operating Condition OK? No Check Operating condition Yes Is main board s fuse ok? No Change Fuse Yes Replace main board

Self Diagnosis & Troubleshooting 3. Other functions normal but compressor not functioning Others OK, Comp not functioning Is fuse in DC loop ok? Yes Check operating conditions No Yes Is IPM OK? Check IPM No Is compressor ok? No Replace Compressor Yes Change Fuse

Self Diagnosis & Troubleshooting 4. Flow switch protection E01 Water flow error Short JK4 JK4 on main board Is water flow error persists? No Flow switch faulty or pump stopped. Yes Main board faulty, replace main board

Self Diagnosis & Troubleshooting 5. Over voltage protection E02 OV/UN Voltage Is Power supply > 490VAC? Yes Check the Electrical supply No Is Power supply < 460VAC? No Yes Power board error, rectify.

Self Diagnosis & Troubleshooting 6. Under voltage protection E03 OV/UN Voltage Is Power supply < 310VAC? Yes Check the Power supply No Is Power supply > 340VAC? No Yes Power board error, rectify.

Self Diagnosis & Troubleshooting 7. Pump overload protection E05 JK8 on main board Pump overload Is voltage of 97, 98 on heat relay VDC = 0 V No Yes Remove JK8, 97 & 98, check connectivity No Main board faulty Yes Pump overload

Self Diagnosis & Troubleshooting 8. Phase missing E06 Phase missing Is Voltage between R,S,T 415VAC ±20%? No Check incoming supply Yes 3 Phase supply Is JRST on main board 415VAC ±20%? Yes Main board faulty No Disconnect power, remove JRST, is voltage of socket 415VAC ±20%? Yes No To Check/replace EMI filter

Self Diagnosis & Troubleshooting Phase seq error E07 Interchange any 2 phase of R, S, T. Memory Error E08 Replace chip 24C02 Sensor Error E09, E12, E14, E20, E21, E22, E23, E24, E25, E30, E31, E33, E34 Check against the resistance cable.

Self Diagnosis & Troubleshooting 9. IPM protection E15 IPM Error Is IPM ok? Yes Replace Display Menu for Inverter No Inverter Chiller Is current at rated frequency ok? No Check compressor Comp Freq : 75Hz EXV : 320 Comp Amp : 9.7A Yes DC Bus : 555V Is IPM Error persists? No Normal

Self Diagnosis & Troubleshooting 9. IPM protection E15 Yes Use thermocouple. Is heat sink temperature >100 C? Yes Rectify Heat Sink Heat Compound No Use thermocouple. Is IPM temperature >100 C? No Main board faulty or wrong signal Yes Is heat compound dried out? No Change IPM IPM Yes Reapply heat compound

Self Diagnosis & Troubleshooting 10. Variable compressor overcurrent protection E16 Comp 1 overload Restart. Check compressor current on the handset. < 18 A? No Yes Check Compressor winding resistance Main board or compressor faulty Replace * For 5ACV30CR, Overload protection triggers when compressor current > 27 A

Self Diagnosis & Troubleshooting 11. Variable drive high pressure protection E17 & E27 High Pressure 1 Remove hp pin from main board. Remove OF. Is high pressure switch ok? No Replace Yes Check AC system for overload Rectify

Self Diagnosis & Troubleshooting 12. Variable drive low pressure protection E18 & E28 Low Pressure 1 Is low pressure switch ok? No Replace Yes Check AC system for low pressure Rectify

Self Diagnosis & Troubleshooting 13. Variable compressor high discharge temperature protection Comp 1 Discharge Overheat > 110 C? Yes Compressor stops Temp sensor ok? (<100 C?) No Replace Check AC system Rectify

Self Diagnosis & Troubleshooting 14. Fixed compressor overcurrent protection Comp 2 Overload Check VAC Check on compressor winding resistance, is it to spec? Check continuity. No Rectify Is supply voltage ok? Yes No Rectify Yes Check on Compressor insulation, is it ok? Check continuity. No Rectify Check current reading on handset against actual reading, is it very big different? Yes No Normal Yes Current sensing circuit error. Replace main board

Self Diagnosis & Troubleshooting Power Board Checking Power Board Power Board Checking Is Power board DCIN voltage normal? No Check bridge diode Yes Is JPpower/DC OUT output normal? Yes Main Board or IPM Board Faulty DCIN (+590VDC) No Replace power Board JPPower (+12Vdc & 7Vdc) DCOut (+15Vdc)

Self Diagnosis & Troubleshooting IPM Board Checking P N Use multimeter to check the Vdc between the P and N. The voltage should be around 590Vdc

Self Diagnosis & Troubleshooting Power Supply Checking Use the multimeter to check the power supply to controller. Refer to any of the 2 phase of supply (R&S, S&T or R&T). The supply should be 415VAC

Self Diagnosis & Troubleshooting Fuse Checking Use multimeter to check the continuity of the fuse. Fuse with sound BEEP is ok

Self Diagnosis & Troubleshooting Fuse Checking Use multimeter to check the continuity of the fuse. Fuse with sound BEEP is ok

Self Diagnosis & Troubleshooting Compressor Checking Check Compressor Check on compressor winding resistance, is it ok? No Change Compressor Yes Check on Compressor insulation, is it ok? No Change Compressor Yes Is compressor short body? Yes Change Compressor No Compressor OK

Self Diagnosis & Troubleshooting Bridge Diode Checking + ~ ~ Use multimeter to check the continuity of the bridge diode.

Resistance Table Low Temperature Sensor (Coil sensor and room/ambient sensor) Temperature Resistance Temperature Resistance ( C) (k Ω) ( C) (k Ω) 6 18.73 18 6.59 4 17.06 20 6.08 2 15.56 22 5.62 0 14.21 24 5.20 2 12.99 26 4.81 4 11.88 28 4.46 6 10.89 30 4.13 8 9.99 32 3.84 10 9.17 34 3.56 12 8.43 36 3.31 14 7.76 38 3.08 16 7.15 40 2.87 When Temp = 25 C, Resistance = 5 kω

Resistance Table High Temperature Sensor (Discharge sensor) Temperature Resistance Temperature Resistance ( C) (k Ω) ( C) (k Ω) 6 457.41 18 137.52 4 410.63 20 125.40 2 369.25 22 114.46 0 332.55 24 104.59 2 299.94 26 95.67 4 279.90 28 87.60 6 245.00 30 80.30 8 221.86 32 73.67 10 201.16 34 67.66 12 182.60 36 62.21 14 165.95 38 57.24 16 150.98 40 52.73 When Temp = 100 C, Resistance = 6.5 kω Back To Content

Centralized Control Solution: Smart Manager

Smart Manager Mini Chiller Nim FCU Mini Chiller Chiller Panel Controller Chiller Panel Controller Smart Manager Nim Netware 2/ SLM3 or wireless controller Netware 2/ SLM3 wireless controller FCU Support up to 50 Chillers in one chiller BUS and up to 120 FCUs in one NIM BUS. Mini Chiller Nim FCU Chiller Panel Controller Netware 2/SLM3 or wireless controller Can Support Up to 50 Chillers On the C BUS Can Support up to 120 FCUs On the NIM BUS

Smart Manager Programmable Energy Saving Timer Chiller One set of 7 days programmable operating schedules (2 ON/ timers per day) FCUs Five set of 7 days programmable operating schedules. (2 ON/ timers per day)

Smart Manager Holiday Setting (FCU) 10 holidays with duration of 99 days each can be set. All FCUs & Chiller will be turned during the holiday period. Timer Schedules are disabled during holiday period.

Smart Manager Display up to 46 types of Chiller Fault/ Alarm and 6 types of FCUs Fault/ Alarm New Alarm 1 [Ch 3] Comp 1 Overload 06/04/05 12:00 am Whenever Smart Manager receives a new alarm from Chiller or FCUs,, an alarm message will pop up on the LCD screen; shows type of alarm, alarm occurred time, date and unit. Backlight blinking and alarms buzzer produces beeping sound (if it s s set ON )

Smart Manager Memory Backup, Alarm Memory for Chiller & FCUs Real Time Clock (RTC) Settings Allows user to set the time and date Password Protection For advance parameter settings (Chiller) Setting Protection

Smart Manager Defrost & Discharge Sensor Temp Display (Chiller) Defrost Sensor Discharge Sensor Comp 1 : 12.8 C Comp 1 : 36.5 C Accumulative Compressor Run Time For servicing purpose

Smart Manager Component Smart Manager Chiller Panel Controller Mini Chiller main board Netware 3 SLM3 NIM FCU main board

Smart Manager Bus Wiring Network

Smart Manager Chiller Bus Chiller Panel 0 (Master) Chiller Panel 1 (Slave) Chiller Panel 2 (Slave) Chiller ID 0 Chiller ID 1 Chiller ID 2 B CN8 CN8 Chiller BUS A Smart Manager

Smart Manager NIM BUS Smart Manager Supply +12 VDC 120 Units of FCU NIM Master NIM Master NIM Master Wired Controller (Netware 3)

Smart Manager NIM BUS FEATURES Fan Coil Unit Monitor FCU s status and control FCU s settings (global, group or individual) Alarm (6 types of FCU fault) Five sets 7 days programmable timer (2 ON/ timer) 10 Holidays setting (turn all units during holiday period)

Smart Manager NIM BUS 120 groups Each group must consist one master Maximum 16 FCUs in one group including master Global Control Group control Individual control

Smart Manager Smart Manager Menu Go into FCU summary pages to Control and Display status of FCU SMART MANAGER Fan Coil Unit Chiller Settings Smart Manager Configuration Go into Chiller summary pages to Control and Display status of Chiller

Smart Manager Menu Structure Chiller Summary Pages Hold ESC 1s Select Chiller Smart Manager Hold ESC 1s Select Setting SM Setting Hold ESC 1s Select Fan Coil Unit FCU Summary Pages

Smart Manager Smart Manager Setting Priority Setting SM SETTINGS Priority : FCU Cool Threshold : 50 % Heat Threshold : 50 % Set to FCU, Chiller running mode is determined by FCU status base on threshold value If one FCU is ON, Chiller turn ON automatically Manual ON the Chiller will be turn automatically by the setting if all the FCU is If all FCUs are, Chiller turn automatically

Smart Manager Smart Manager Setting Priority Setting SM SETTINGS Priority : Chiller Cool Threshold : 50 % Heat Threshold : 50 % Set to Chiller, Chiller running mode is determined by Chiller status itself If Chiller is, No FCU can be turned ON Manual ON the FCU will be turn automatically by the setting If Chiller turn ON, FCUs can be turned ON or

Smart Manager Smart Manager Setting Priority Setting SM SETTINGS Priority : None Cool Threshold : 50 % Heat Threshold : 50 % Set to None, Operation Between Chiller and FCU isolated This priority setting is the factory setting

Smart Manager Threshold Setting SM SETTINGS Priority : FCU Cool Threshold : 60 % Heat Threshold : 70 % Must Set to FCU 50% Value setting 100% Ensure the Running Mode Of Chiller Total of FCU 10 No. of FCU in Cool Mode 7 6 No. of FCU in Heat Mode 3 4 Cool Threshold (C) 70 60 Heat Threshold (H) Running Mode of Chiller cooling cooling If C 60, Run as Cooling mode (current setting mode) 5 4 3 5 6 7 50 60 70 cooling cooling Heating If 40<C<60, remain as the current mode 2 8 80 Heating If H 70, Switch to Cooling Mode

Smart Manager FCU Unit Addres Setting Adjust the Dipswitch (DSW1) to assign Group Address setting Adjust the Dipswitch (DSW2) to assign FCU Unit setting

Smart Manager Connection to Smart Manager CN2 ~ Connect to Wired Controller CN3 ~ Connection of NIM Bus to Smart Manager CN1 ~ Connect to Main Board (WIV3)

Smart Manager Installation of Smart Manager A B Smart Manager A B

Smart Manager Menu Structure Diagram for FCU Operation Menu Press ENTER Press ENTER Setting Menu Summary Pages Press and Hold ENTER for 1s Main menu Unit Selection Menu Timer Menu Alarm Menu

Smart Manager Unit Selection Menu We can control the FCU as : Global Group Individual Unit Selection : Select All Select Group Select One Display the Global Master (G0U0) status and control all FCUs setting at once Display the Group Master (G1U0) status and control all FCUs setting in that group at once Only display the chosen FCUs and control the FCUs setting

Smart Manager Method 1 Select the Unit Selection and press ENTER Changing Display Unit Press & hold ENTER 1s (in Summary Pages) Unit Selection : Select All Select Group Select One 01/01/2000 12:00am Status Mode Set Temp Fan Room Temp Unit : : Cool : 24 o C : High : 27 o C : G0U0 Summary Page Unit : All G1 G0U1

Smart Manager Method 2 Changing Display Unit Press & hold UP or DOWN Key 1s (in Summary Pages) to scroll and display each FCU unit in the network 01/01/2000 12:00am Status : Mode : Cool Set Temp : 24 o C Fan : High Room Temp : 27 o C Unit : G0U0 Unit : GXUX will keep on changing to show ALL the FCU units exist in the network Let Off the UP or DOWN Key until the GXUX that u wish to display

Smart Manager Summary Pages FCU Menu Structures Press Up and Down Key for page scrolling And Display the Operation Status of FCU 01/01/2000 12:00 am 01/01/2000 12:00 am Status Mode Set Temp Fan Room Temp Unit : ON : Cool : 24 o C : High : 27 o C : G0U0 Swing : Yes Sleep : No Compressor : Schedule : 1 Timer : Disable

Smart Manager Main Menu of FCU Control the Operation Password Protected Advanced Parameters Setting & Panel Option MAIN MENU Operation Menu Setting Menu Timer Menu Alarm Menu Clock & Date Setting Timer On/Off Schedule Holiday Off Duration Record 20 erasable alarm histories

Smart Manager Operation Menu Change the Operation Settings of FCU 01/01/2000 12:00 am 01/01/2000 12:00 am Status Mode Set Temp Fan : ON : Cool : 24 o C : High Swing : Yes Sleep : No Schedule : 1 Timer : Disable Enable or Disable the Timer Schedule Select the Timer Schedule

Smart Manager Panel Option Setting of the Panel itself Backlight : Normal Buzzer : ON Screen Saver : Disable Timeout : 5m Contrast : 50% Brightness : Medium Temp Unit : o C Create a Beeping sound whenever It trigger any alarm Temperature Unit can be set either o For o C

Smart Manager Timer Menu Set Time: hh mm Set Date: yy mm dd MAIN MENU Clock Setting Date Setting Timer Schedules Holiday

Smart Manager Timer Schedule 5 sets of programmable timer schedules 7 days of timer schedule (Sun to Sat) 2 ON/ events per day Assigning timer schedule as Global (All FCUs), group (Groups of FCU) or individual (one FCU) Manually On/Off can always override the timer schedule SCHEDULE SETTINGS Schedule 1 Schedule 2 Schedule 3 Schedule 4 Schedule 5 Timer 1 Timer 2 ON ON Sun 0800 1600 Mon 0800 1600 Tue 0800 1600 Wed 0800 1600

Smart Manager Assigning ON/ Schedule After set the 7 days programmable On/Off Timer in Timer Schedule (up to 5 Sets) Select ONE set of timer schedule in Operation Menu Enable the Timer in order to activate the timer schedule OPERATION MENU Swing : Yes Sleep : No Schedule : 1 Timer : Enable

Smart Manager Holiday Setting All the FCU and Chiller will be turn Temporally Disable all the timer schedules 10 sets of Holiday Schedules 99 days duration for each holiday FCU can be opened manually ; FCU will switch off at 00:00am for the following day if it still in holiday mode SCHEDULE SETTINGS Holiday 1 Holiday 2 Holiday 3 Holiday 4 Holiday 5 SCHEDULE SETTINGS Holiday 6 Holiday 7 Holiday 8 Holiday 9 Holiday 10

Smart Manager Holiday Setting How to set a Holiday schedule? Set Holiday 1 Month : 1 Day : 25 Duration : Disable Specify the month and date for Holiday starting period Duration for the Holiday is from 1~99 days A sign [H] will be shown in Summary Page during holiday period

Smart Manager Example Christmas Holiday : 24/12/10 ~ 26/12/10 Duration : 3 days Set Holiday 1 Month : 12 Day : 24 Duration : 3 Start from 00:00am, 24/12/03 Holiday Mode will be activated Holiday Mode will be deactivated starting from 00:00am, 27/12/03

Smart Manager New Alarm Display Faulty or Alarm is triggered An New Alarm or Alarms will pop up on the LCD Beeping sound Backlight blinking Alarm occurred type Alarm 1 Outdoor coil Sensor missing [G0U0] Alarm occurred Unit (FCU ID) 01/01/00 12:00am Alarm occurred Date Alarm occurred time Back To Content

Selection Software

Smart Manager Independent Chilled Water FCU selection software. Independent Mini Chiller selection software. McQuay Chilled Water Product Selection Virtual Piping Sizing Back To Content

Competitor s Product Comparison

Competitor s Products Comparison Product Range 2HP 3HP 5HP 7HP 9HP 13HP 20HP 85HP 250HP OYLM M5ACVCR DAIKIN EWAQ / YQ UWAXP CARRIER AquaSnap BRIGHT BHLRCFZ Using R410A Refrigerant Using R407C Refrigerant

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV030CR 3HP DAIKIN EWYQ007ACV3HP BRIGHT BHLRCF10Z Refrigerant R410A R410A R407C Capacity, BTU/hr 27,000 24,225 33,096 Heating Capacity, BTU/hr 33,000 29,787 39,238 Noise, dba 59 63 56 COP 5.12 8.22 9.18 Height, inch 31.10 31.69 62.99 Width, inch 39.76 46.85 41.34 Depth, inch 18.11 14.17 19.68 Volume, ft3 12.96 12.18 35.31

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV055CR 5HP DAIKIN UWAXP125AY1 BRIGHT Refrigerant R410A R407C Capacity, BTU/hr 50,000 42,700 Heating Capacity, BTU/hr 66,000 Noise Indoor, dba 62 COP 6.59 Height, inch 55.51 57.09 Width, inch 39.76 32.87 Depth, inch 18.11 27.17 Volume, ft3 23.13 35.31

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV075CR 7HP DAIKIN UWAXP190AY1 BRIGHT Refrigerant R410A R407C Capacity, BTU/hr 70,000 64,900 Heating Capacity, BTU/hr 75,000 Noise Indoor, dba 65 COP 7.75 Height, inch 55.51 57.09 Width, inch 39.76 50.39 Depth, inch 18.11 27.17 Volume, ft3 23.13 35.31

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV100CR 9HP DAIKIN UWAXP250AY1 BRIGHT Refrigerant R410A R407C Capacity, BTU/hr 95,000 85,400 Heating Capacity, BTU/hr 100,000 Noise Indoor, dba 63 COP 7.92 Height, inch 49.61 57.09 Width, inch 59.06 50.39 Depth, inch 35.43 27.17 Volume, ft3 60.07 35.31

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV135CR 13HP DAIKIN UWAXP375AY1 BRIGHT Refrigerant R410A R407C Capacity, BTU/hr 131,500 128,000 Heating Capacity, BTU/hr 141,500 Noise Indoor, dba 67 COP 8.36 Height, inch 49.61 59.06 Width, inch 59.06 75.79 Depth, inch 35.43 27.17 Volume, ft3 60.07 70.63

Competitor s Products Comparison INVERTER MINI CHILLER OYLM M5ACV210CR 20HP DAIKIN UWAXP500AY1 BRIGHT Refrigerant R410A R407C Capacity, BTU/hr 200,00 171,000 Heating Capacity, BTU/hr 210,000 Noise Indoor, dba 85 COP 8.97 Height, inch 70.32 59.06 Width, inch 82.40 101.18 Depth, inch 46.93 27.17 Volume, ft3 157.36 93.94 Back To Content

Thank You Back To Content