Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Similar documents
Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Zareba Sensepoint Pro

Operating Instructions

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Operating Instructions and Maintenance Manual

Life Safety Network. Intelligent solutions for advanced requirements

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sieger Apex. Flexibility that meets your requirements

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Searchpoint Optima Plus

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Zareba Metro Gas Detector

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Technical Manual. Zareba Sensepoint Gas Detectors

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Sensepoint XCL Fixed Gas Detector

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

XNX Universal Transmitter

3M Oldham OLCT 100. Description. Fixed Gas Detector

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

System 57. An advanced world of intelligent gas detection system management

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Honeywell Analytics. Order List BW Clip & IntelliDoX

Zareba Unipoint controller

GAS DETECTOR ST400EC PART.NO

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

Fixed-Point Industrial Gas Detection

System 57. An advanced World of intelligent gas detection system management

XNX Universal Transmitter

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Transmitters/Sensors. OLCT Series

Operating Instructions

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Neotronics Impact & Impact Pro

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Operating Instructions

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Fixed-Point Industrial Gas Detection

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

APPLICATION DATA SHEET

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

Toxic Gas Detection. Model F12. Toxic Gas Detection

Searchpoint Optima Plus

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

MeshGuard and MeshGuard Gamma

MeshGuard and MeshGuard Gamma

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Touchpoint Pro Flexible Gas Control System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SPM Flex Chemcassette Tape-Based Gas Detector

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

SIMRAD GD10 IR GAS DETECTOR

XNX Universal Transmitter

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

ALTAIR 5X Multigas Detector Product Specification

P R O D U C T D ATA S H E E T

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

ULTIMA X5000. MSAX5000.com

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Safe Operation Manual. Honeywell IQ Force Gas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

Transcription:

Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs.

Sensepoint Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications Proven Sensor Technology Surecell TM electrochemical sensors Poison resistant catalytic bead Fast and reliable Typical 2 to 5 years operational life ATEX Certified Complies with the latest European standards Hazardous area approval and performance IP 65/66 for use in harsh environments Easy to Use Factory set operation Simple to replace Minimal training required Range of Accessories Weatherproof cap Flow adaptor Duct mounting kit Collecting cone The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially explosive atmospheres is made by the use of a suitable Exd or Exe approved junction box. The industry standard outputs from Sensepoint are connected to either a choice of Honeywell Analytics controllers or 3rd party DCS/PLC systems. Both flammable and toxic versions are certified to the latest European ATEX safety and performance standards. The flammable detector is available in either %LEL or PPM detection range versions and provides an industry standard mv bridge output. Typical life expectancy is greater than 5 years, after which the detector is simply replaced with a new one. The toxic detectors are supplied pre calibrated for easy installation and provide an industry standard 2 wire 4-20mA loop output. User connections are Exd, while front end Intrinsic Safety (IS design allows for easy exchange of the replaceable sensor while powered. IS design also removes the need for a sinter enabling very fast speed of response and detection of sticky gases such as Chlorine and Ammonia. Sensepoint has proven its suitability across a wide range of demanding applications by delivering high performance and reliability at an affordable cost.

Installation Details Dimensions Flammable %LEL or PPM Version Toxic or Oxygen Version Sensepoint flammable and toxic gas detectors are installed using suitable Exd or Exe junction boxes. The standard junction box available from Honeywell Analytics includes an earth continuity plate for added RFI protection. The detectors have a choice of mounting thread size to match local preferences. The Sensepoint range of flammable and toxic detectors are designed for use with a wide range of controllers available from Honeywell Analytics or with 3rd party control equipment accepting their industry standard output signals.

Installation Details Electrical Connections Typical Terminal Connections Flammable %LEL Version Brown (S Blue (NS White (01 +VE -VE Signal To Controller 3 Wire mv Bridge Circuit Toxic or Oxygen Version Blue (- Cable Screen +VE Signal To Controller Red (+ Screen 2 Wire 4-20mA (Sink Flammable PPM Version Blue (NS Green (01 Red (S Cable Screen +VE -VE Signal To Controller Screen 3 Wire mv Bridge Circuit

Technical Specification Gas & Range Flammable 0-100%LEL Flammable PPM (Typically 0-10%LEL Hydrogen Carbon Sulfide (H 2 S Monoxide (CO 20/ 50/100ppm 100/200/500ppm Ammonia (NH 3 50/ 1000ppm Chlorine (Cl 2 5/15ppm Oxygen (O 2 25% V/V Hydrogen (H 2 1000/10000ppm Sulfur Dioxide (SO 2 15/50ppm Nitric Oxide (NO 100ppm Nitrogen Dioxide (NO 2 10ppm Operating Temp -55 to +80 C 1-30 to +65 C -25 to +50 C -20 to +50 C -20 to +40 C -20 to +50 C -15 to +40 C Operating Humidity Continuous: 20 to 90% RH (non-condensing. Intermittent: 10 to 99% RH (non-condensing Storage Conditions 0 to 25 C; 30 to 70% RH 0 to 25 C; 30 to 70% RH Operating Pressure 90 to 110kPa Warm-up Time < 10 minutes < 20 minutes < 3 minutes < 5 minutes < 3 minutes 12 hours 1 hour Response Time T20 < 6 secs < 5 secs < 10 secs < 3 secs < 3 secs < 15 secs T50 < 5 secs < 15 secs < 12 secs < 10 secs < 20 secs < 5 secs < 10 secs < 10 secs < 5 secs < 30 secs T90 < 10 secs < 40 secs < 30 secs < 65 secs < 105 secs < 10 secs < 45 secs < 90 secs < 30 secs < 60 secs Supply 200mA; 0.7W maximum 18 to 30V dc; 0.9W maximum Signal Output mv bridge Loop powered 4 to 20mA Linearity < 5% fsd or ±10% of reading < 5% fsd Operating Life 5 years (typical 2 years (typical 18 months (typical 1 year (typical 18 months (typical Storage Life Typically, over 5 years when in original sealed packaging 6 months. Stability (zero with time* < ±3% fsd/yr < ±2% fsd/yr with temperature** < ±1% fsd 2 < ±3% fsd < ±5% fsd < ±6% fsd < ±2% fsd < ±2% fsd < ±5% fsd with humidity < ±1% fsd < ±10% fsd < ±2% fsd < ±10% fsd < ±2% fsd < ±2% fsd < ±10% fsd Stability (span with time* < ±3% fsd/yr < ±2% fsd/yr < ±4% fsd/yr < ±20% fsd/yr < 10% fsd/yr < ±20% fsd/yr < ±2% fsd/yr with temperature*** < ±3% fsd < ±8% fsd < ±25% fsd < ±20% fsd < ±20% fsd < 40% fsd < ±10% fsd < ±60% fsd < ±15% fsd < ±25% fsd with humidity < ±2% fsd < ±10% fsd < ±2% fsd < ±10% fsd < ±2% fsd < ±1% fsd < ±2% fsd < ±10% fsd Weight 190g 185g 205g 185g0 Construc. Materials Polyphenylene sulfide (PPS I.P. (NEMA Rating Certification Details (ATEX Other Certifications Ex II 2 GD EEx d IIC T6 (Tamb = -55 C to +55 C T5 (Tamb = -55 C to +70 C 3 BAS98ATEX2156X/4 SIRA03ATEX1116X (Performance IP65 (standard, IP67 (with weather protection fitted Ex II 2 GD EEx dia IIC T4 (Tamb = -55 C to +65 C BAS90ATEX2157X/5 Australian: SAA, Russian: GOST Applicable Standards This product complies with the relevant CE standards including: EMC to EN50270, Flammable to EN50054/57, Toxic to EN445544 (H 2 S only NOTES 1 High temp range version available -55 to +150 C See separate datasheet DS0303 2 Over temp range -20 to +55 C 3 LEL version T4-55 to +80 C, T3-55 to +150 C * = % of range (fsd per year ** Over operating temperature range *** = % of applied concentration

Ordering Information Accessories 00780-A-0100 00780-A-0160 Right Angle Mounting Bracket For Ceiling Mounting 02000-A-1635 Series 2000 Weather Housing Use With Toxic Sensor 02000-A-1640 Series 2000 Weather Housing Use With Flammable Sensor 02000-A-1642 Series 2000 Collecting Cone Use With Flammable Sensor 02000-A-1645 Series 2000 Calibration Flow Housing Assembly (Flam & Toxic 02000-A-3120 Series 2000 Flow Housing Assembly Plastic 2106B1110 Catalytic Bridge To 4-20mA Converter 2106B2114 Toxic Calibration Kit including calibration cover, removal tool, potentiometer adjustment tool 2106D2055 M36/M40 thread adaptor 225-262-138 Cable gland and caps, 20mm, Nylon Spares 2106B1545 2106B1546 2106B1547 2106B1548 2106B1549 2106B1594 2106B1595 2106B1596 2106B1597 2106B1598 2106B1599 Term Hsg Bartec DE1155 With Continuity Plate 1 x 25mm 3 x 20mm Entries ATEX Approved O 2 Electrochemical Cell Exchange Kit SO 2 Electrochemical Cell Exchange Kit Cl 2 Electrochemical Cell Exchange Kit CO Electrochemical Cell Exchange Kit H 2 S Electrochemical Cell Exchange Kit NO Electrochemical Cell Exchange Kit NH 3 0-1000ppm Electrochemical Cell Exchange Kit NH 3 0-50ppm Electrochemical Cell Exchange Kit H 2 0-1000ppm Electrochemical Cell Exchange Kit H 2 0-10000ppm Electrochemical Exchange Kit NO 2 0-10ppm Electrochemical Exchange Kit Calibration Equipment Contact your local Honeywell Analytics representative for details of suitable calibration equipment Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (044 943 4300 Fax: +41 (044 943 4398 gasdetection@honeywell.com Sensepoint Combustible 2106B1200 Sensepoint 0-100% LEL Flammable Sensor M20 2106B1201 Sensepoint 0-100% LEL Flammable Sensor M25 2106B1202 Sensepoint 0-100% LEL Flammable Sensor M26 2106B1203 Sensepoint 0-100% LEL Flammable Sensor M26 (VQ1AB pellistor 2106B1204 Sensepoint 0-100% LEL Flammable Sensor 3/4NPT 2106B1205 Sensepoint ppm (0-10% LEL Flammable Sensor M20 2106B1209 Sensepoint ppm (0-10%LEL Flammable Sensor 3/4NPT Sensepoint Toxic 2106B1400 Sensepoint Hydrogen Sulfide (H 2 S 0-20ppm Toxic Sensor M20 2106B1401 Sensepoint Hydrogen Sulfide (H 2 S 0-50ppm Toxic Sensor M20 2106B1402 Sensepoint Hydrogen Sulfide (H 2 S 0-100ppm Toxic Sensor M20 2106B1700 Sensepoint Hydrogen Sulfide (H 2 S 0-20ppm Toxic Sensor 3/4NPT 2106B1701 Sensepoint Hydrogen Sulfide (H 2 S 0-50ppm Toxic Sensor 3/4NPT 2106B1702 Sensepoint Hydrogen Sulfide (H 2 S 0-20ppm Toxic Sensor 3/4NPT 2106B1405 Sensepoint Carbon Monoxide (CO 0-100ppm Toxic Sensor M20 2106B1406 Sensepoint Carbon Monoxide (CO 0-200ppm Toxic Sensor M20 2106B1407 Sensepoint Carbon Monoxide (CO 0-500ppm Toxic Sensor M20 2106B1705 Sensepoint Carbon Monoxide (CO 0-100ppm Toxic Sensor 3/4NPT 2106B1706 Sensepoint Carbon Monoxide (CO 0-200ppm Toxic Sensor 3/4NPT 2106B1707 Sensepoint Carbon Monoxide (CO 0-500ppm Toxic Sensor 3/4NPT 2106B1410 Sensepoint Chlorine (Cl 2 0-5ppm Toxic Sensor M20 2106B1411 Sensepoint Chlorine (Cl 2 0-15ppm Toxic Sensor M20 2106B1711 Sensepoint Chlorine (Cl 2 0-15ppm Toxic Sensor 3/4NPT 2106B1413 Sensepoint Ammonia (NH 3 0-50ppm Toxic Sensor M20 2106B1414 Sensepoint Ammonia (NH 3 0-1000ppm Toxic Sensor M20 2106B1415 Sensepoint Ammonia (NH 3 0-100ppm Toxic Sensor M20 2106B1713 Sensepoint Ammonia (NH 3 0-50ppm Toxic Sensor 3/4NPT 2106B1714 Sensepoint Ammonia (NH 3 0-1000ppm Toxic Sensor 3/4NPT 2106B1715 Sensepoint Ammonia (NH 3 0-100ppm Toxic Sensor 3/4NPT 2106B1416 Sensepoint Hydrogen (H 2 0-1000ppm Toxic Sensor M20 2106B1417 Sensepoint Hydrogen (H 2 0-10000ppm Toxic Sensor M20 2106B1716 Sensepoint Hydrogen (H 2 0-1000ppm Toxic Sensor 3/4NPT 2106B1717 Sensepoint Hydrogen (H 2 0-10000ppm Toxic Sensor 3/4NPT 2106B1418 Sensepoint Nitric Oxide (NO 0-100ppm Toxic Sensor M20 2106B1718 Sensepoint Nitric Oxide (NO 0-100ppm Toxic Sensor 3/4NPT 2106B1420 Sensepoint Sulfur Dioxide (SO 2 0-15ppm Toxic Sensor M20 2106B1421 Sensepoint Sulfur Dioxide (SO 2 0-50ppm Toxic Sensor M20 2106B1720 Sensepoint Sulfur Dioxide (SO 2 0-15ppm Toxic Sensor 3/4NPT 2106B1721 Sensepoint Sulfur Dioxide (SO 2 0-50ppm Toxic Sensor 3/4NPT 2106B1422 Sensepoint Nitrogen Dioxide (NO 2 0-10ppm Toxic Sensor M20 2106B1722 Sensepoint Nitrogen Dioxide (NO 2 0-10ppm Toxic Sensor 3/4NPT 2106B1430 Sensepoint Oxygen (O 2 25% V/V Toxic Sensor M20 2106B1730 Sensepoint Oxygen (O 2 25% V/V Toxic Sensor 3/4NPT Americas Honeywell Analytics Distribution, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (02 2025 0307 Fax: +82 (02 2025 0329 analytics.ap@honeywell.com Technical Services ha.emea.service@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Sensepoint_DS0326_V4_EMEA 09/07 2007 Honeywell Analytics 11577