Toroidal Conductivity Transmitters Series APT4000 Specifications

Similar documents
MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Conductivity Product Name Part No.

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Hydrazine Analyzer Series 2171 Specifications

APT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual MU1I-6246 Revision 1 01/00

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

Figure 1 DirectLine DL423 Sensor. Description, continued

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Figure 1 DirectLine DL423 Sensor. Description, continued

Inductive Conductivity

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

Silica, Phosphate, Hydrazine Analyzers Series 2140 Specifications

Nov 08 PRODUCT SPECIFICATION SHEET

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Controllers, Indicators & Set Point Programmers

Low Temperature Zirconia Oxygen Analyzer

UDC 700 Universal Digital Controllers and Indicator Specifications

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Dual Input Toroidal Analyzer

Intrinsically Safe Transmitters, Option Code 2n

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

UDC100 Universal Digital Controller Specifications

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Gas and On-Line Analyzers

Potential Applications

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet


Sensors and Switches in Commercial Traction Elevators

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

HIH-4030/31 Series Humidity Sensors

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

HIH-4010/4020/4021 Series Humidity Sensors

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

I/A Series 716C 1/16 DIN Temperature Controller

HIH-4000 Series Humidity Sensors

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

UDA2182 Universal Dual Analyzer

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Level Measurement Continuous level measurement - Ultrasonic transmitters

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

UDA2182 Universal Dual Analyzer

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Oxygen (O2) Single-Point Gas Detection System

Duct Humidity/Temp Sensor

Force Sensors Line Guide

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Linear Current Sensors

Model Q45P/R. ph/orp Monitor...

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

HIH-4602-L Series Humidity Sensors

Danfoss gas detection unit Type GD Heavy Duty

DIGITAL METERS Large Display Temperature Meters Instruction Manual

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Model Q45P/R. ph/orp Monitor...

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Airflow Sensors Line Guide

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Continuous level measurement Ultrasonic transmitters

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

UDA2182 Universal Dual Analyzer Specifications

CLARITY II TURBIDIMETER

Dual Input ph/conductivity Analyzer

WARNING MISUSE OF DOCUMENTATION

Durafet Non-Glass ph Electrodes Specifications

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Dual Input ph/orp Analyzer

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Airflow Sensors Line Guide

Transcription:

Toroidal Conductivity Transmitters Series APT4000 Specifications 70-82-03-42 March 2001 Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity, chemical concentration and salinity in industrial processes within the chemical, food and dairy, pulp and paper, refinery, metals, and other industries. The APT4000 s NEMA 4X/IP65-rated enclosure is specifically designed to meet the measurement needs of Class I, Division 2 (non-incendive) and general-purpose areas. The transmitter can be used with Honeywell toroidal conductivity cells or electrically compatible sensors. The transmitter has a universal (20-253 V ac/dc, 45-65 Hz) power supply with one 4-20 ma output, two high/low alarm relays, a diagnostic relay, and a wash relay. Description The Honeywell APT4000 series of transmitters offers the widest available selection of advanced features in a reliable and economical instrument. Reliability First The advanced features of the APT4000 transmitter guarantee complete reliability. The APT4000 continuously monitors sensor and transmitter electronics and immediately displays diagnostic information at the onset of a problem. If an error or diagnostic is found, the transmitter will indicate the appropriate error code or pictograph (see Figure 2), blink a red LED and adjust the error current to 22 ma if desired. A manual loop-back check is available to test the integrity of the 4-20 ma output. Quick Problem Assessment The APT4000 has a large front display for quick recognition of process parameters and diagnostics even at a distance. Only the APT4000 employs visual feedback to quicken setup and maintenance times and to minimize errors made during calibrations. Figure 1 APT4000 TC Transmitter Visual feedback refers to pictograph type characters that appear on the display both to prompt and respond to operator and process changes. Pictograph type characters also appear during problem conditions to report diagnostics for easy troubleshooting. There is even a Sensoface pictograph that provides constant feedback to the operator on whether or not there is a problem with the cell. These easily learned and recognized symbols make the APT4000 an easy-to-use instrument in any language. Foolproof Calibrations Each Honeywell conductivity cell has unique measuring characteristics when shipped from the factory. It is possible that these characteristics will vary slightly depending upon the installation as well. For optimum accuracy, a singlepoint calibration in a known conductivity solution should be performed when a new cell is installed. Further calibration adjustments are also available for enhanced accuracy in special applications.

Toroidal Conductivity Transmitters 2 Works with a Variety of Cells The inputs to the APT4000 Series include the Honeywell 5000TC toroidal conductivity cells, which feature a 1000 ohm Platinum RTD. In addition, a wide variety of other manufacturers toroidal conductivity cells are compatible. Fully Certified The area certification for the ATP4000 TC is FM Class I, Div. 2, Groups A-D (non-incendive). In addition, each transmitter comes standard with CE. Temperature Loop Current Conductivity Cell Check Display/Process Variable Alarm Setting Calibration Security Code Entry Interval/Response Time ON OFF Sensoface R Measurement Units Conductivity Cell Data Slope Zero enter Continue with ENTER Wait Hold State Active Bar for Instrument Status Figure 2 APT4000 TC Display Features Features Large display with easy-to-read 0.75 inch measured value Applications The APT4000 TC transmitter is designed to meet the measurement needs of a number of industries, including: Simple operator interface with basic pictographs Continuous diagnostics for monitoring calibration, cell health, and transmitter self-test Manual loopback check for integrity of 4-20 ma output Chemical Food and Dairy Pulp and Paper Refinery Application in Class I, Division 2 or General Purpose Metals areas Wall, pipe or panel mounting Easy installation with pre-assembled empty enclosure and plug-in terminals Optical alarm signaling by blinking red LED Integrated current source for simple checking of peripheral devices Quick Response Time (less than five seconds per step change) NEMA 4X, IP65 plastic enclosure Dedicated high/low alarm relay

Toroidal Conductivity Transmitters 3 Specifications Conductivity Range 00.00 to 99.99 ms/cm, 000.0 to 999.9 ms/cm, 0000 to 1999 ms/cm Conductivity Input Concentration Range NaCl 0-26.3 % by wt (0 C) 0-28.1 % by wt (100 C) HCl 0-17 % by wt ( 20 C) 0-17 % by wt (50 C) NaOH 0-12 % by wt (0 C) 0-22 % by wt (100 C) H2SO 4 0-25 % by wt ( 17 C) 0-35 % by wt (110 C) H2SO 4 95-99 % by wt ( 10 C) 95-99 % by wt (110 C) HNO 3 0-28 % by wt ( 20 C) 0-28 % by wt (50 C) Salinity Range Accuracy Step Change Response Time Sensocheck Sensor Standarization Sensoface 0.0 % to 45.0 % (0 C to 35 C) (1% of measured value) (0.02 ms/cm) (1 of least significant digit) Less than 5 seconds Diagnostics Polarization detection and monitoring of cable capacitance (can be switched off) - Entry of cell calibration factor with display of conductivity and temperature - Temperature probe adjustment - Provides information on the electrode state via Sensocheck - Monitors asymmetry potential, slope, and response time during calibration Temperature Input Range Pt100/1000 RTD, 100 K Thermistor: 20.0 C to +150.0 C (+4 F to +302 F) Resolution Pt100/1000 RTD, 100 K Thermistor: 0.1 C or 1 F Accuracy Pt1000 RTD: ± 0.5 C Pt100 RTD: ± 1 C 100K Thermistor: ± 0.5 C below 100 C; less than 1 C above 100 C Temperature Compensation Display Sensor Standardization Options Test Mode Automatic Compensation using Pt 100 /1000 RTD or 100 K Thermistor, or manual adjust LCD display 76 mm x 48 mm (3 x 1-7/8 ) dimensions, 7-segment Cond Value: character height 17 mm (0.66"), meas. symbol 10 mm (0.4") Temperature: character height 10 mm (0.4"), meas. symbol 7 mm (0.33") Sensoface with three states, 5 status bars, 16 pictographs / symbols, Red Alarm LED Security protection with four-digit mode codes to access calibration and configuration options Calibration Calibration by Cell Factor: 0.100 to 19.99 Calibration by Transfer Ratio: 1.00 to 99.99 Zero Point Air Calibration: 0.5 ms/cm offset (low conductivity measurements) Calibration by Standardizing Solution Resistance measurement by use of fixed resistor temporarily inserted through the sensor bore.

Toroidal Conductivity Transmitters 4 Area Certifications / Compliances Approvals Data Retention RFI Suppression / Immunity to ESD FM Class I, Div. 2, Groups A-D Parameters and calibration data > 10 years (EEPROM) To EN 50 081-1 and EN 50 081-2 Ambient Conditions Operation/Environmental temperature: (T4) 20 C to +55 C ( 4 F to +131 F) (T6) 20 C to +40 C ( 4 F to +104 F) Output Current Supply Voltage Overrange Current Error Current Source Output Characteristic Minimum Span Contacts Maximal Current/Voltage Transport and Storage temperature: Supply/Output 0 ma or 4 ma to 20 ma current loop, 10 V floating 20 V to 253 V ac/dc, 45 Hz to 65 Hz, 2 VA / 1.5 W 22 ma for error messages < 0.3 % of current value +0.05 ma 3.80 ma to 22.0 ma Linear or Logarithmic LIN: 5 % of the selected range LOG: 1 decade Alarms/Relays 20 C to +70 C ( 4 F to +158 F) Alarm minimum: SPST N/O (Hysteresis 0.2 % of measured range) Alarm maximum: SPST N/O (Hysteresis 0.2 % of measured range) Diagnostic contact: SPST N/C Wash contact: SPST N/O AC: < 250 V / < 3A / < 750 VA DC: < 30 V/ < 3A / < 90 W Physical Enclosure Plastic enclosure made of PBT (polybutylene terephthalate) bluish-gray RAL 7031 Mounting Wall, Pipe, or Panel Mount Dimensions Height: 144 mm (5.67") Width: 144 mm (5.67") Depth: 105 mm (4.13") Protection NEMA 4X, IP65 Cable glands 3 breakthroughs for Pg 13.5 2 breakthroughs for NPT 1/2 or Rigid metallic conduit Weight Approximately 1 kg (2.2 lb.) Figure 3 APT4000TC Terminal Assignments

Toroidal Conductivity Transmitters 5 Model Selection Guide Reference 51-52-16-73 NOTE: Mounting kit not included with APT4000.

Toroidal Conductivity Transmitters 6 Figure 4 Dimension Drawing for APT4000 and P/N 51205990-001 panel mounting kit

Toroidal Conductivity Transmitters 7 Figure 5 Dimension Drawing for APT4000 with Wall or Pipe Mounting

Toroidal Conductivity Transmitters 8 Warranty/Remedy Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. For More Information Learn more about how Honeywell s APT4000 Series Toroidal Conductivity Transmitters can continuously measure conductivity, chemical concentration and salinity in industrial processes, visit our website www.honeywell.com/ps/hfs or contact your Honeywell account manager. Honeywell Process Solutions 1860 West Rose Garden Lane Phoenix, Arizona 85027 Tel: 1-800-423-9883 or 1-800-343-0228 www.honeywell.com/ps 70-82-03-42 March 2001 2010 Honeywell International Inc.