Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Similar documents
Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Conventional Leaflets

Operating instructions Vigilon panel and Network node Fire detection and alarm system

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

USER MANUAL & MAINTENANCE GUIDE OG OO

Fire detection and alarm system Operating instructions

FIRE ALARM CONTROL PANEL FVC01-08

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

User Operation Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Fire Alarm Control Panel. System Maintenance and Log Book

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Control Panel User Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

SYSTEM 5000 USER MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Installation, Operating and Maintenance Manual

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Intelligent Security & Fire Ltd

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

SECURIT 703 USER MANUAL

Document No Issue 4 user manual

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Control Panel User Guide (TO BE RETAINED BY THE USER)

Application, Installation, Operation & Maintenance Manual

Intelligent Security & Fire Ltd

Control Panel User Guide

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

USER MANUAL CEF AP28 CONTROL PANEL

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Conventional Fire Alarm System 2014 V1.2

KFP-CF Series Operation Manual

ZP3 Operator & Maintenance Manual Version 1

Intelligent Security & Fire Ltd

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

Intelligent Security & Fire Ltd

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

System 800 Addressable Fire Detection & Alarm System

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

Excel-EN Conventional Fire Control Panel

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

SECURIT 700L USER MANUAL

user manual Document No , Revision 03 November 2015

ID2000. operating manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

ISLE OF WIGHT FIRE & RESCUE SERVICE

The EN54 Part 2 and 4 Fire System

SECURIT 700L PLUS ENGINEERING MANUAL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Racal-Guardall. Countess. User Instructions. Countess

ZSC100 Gas Detection and Alarm System Controller

Firetrax Professional Conventional Fire Control Panel

The EN54 Part 2 & 4 Fire System

user manual and log book XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

NX-148 LCD CODE PAD TABLE OF CONTENTS

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Control Panel Engineering and Commissioning Instructions

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Installation Manual Premier 412/816/832. Issue 10

Conventional & Twin-wire Fire System

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

ORION Mini-Rep INSTALLATION MANUAL

Electro-Detectors Page 2. Revision History. EDA-Z Installation and Operation Manual

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

LOG BOOK & CERTIFICATES

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

CSP-204 CSP-208 CSP-104 CSP-108

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Transcription:

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels The panels are designed in accordance with the requirements of EN54 Part 2:1997 (and include optional clauses 7.8, 7.11 & 10), plus the requirements of EN54 Part 4:1997. This publication covers the: Conventional fire alarm panels: 1 zone panels:- XENEX1, 75585-01NMB, 13270-01 and 13270-01LB 2 zone panels:- XENEX2, 75585-02NMB, 13270-02 and 13270-02LB 4 zone panels:- XENEX4, 75585-04NMB, 13270-04 and 13270-04LB 8 zone panels:- XENEX8, 75585-08NMB, 13270-08 and 13270-08LB Fire alarm repeat panels: XENEX RPT, 75586-08NMB and 13271-08 and 13271-08LB. Panel code ending with LB signify Less batteries. This manual and logbook is intended for use by the end user and should be located in a secure but accessible position close to the panel. It is the responsibility of the end user to maintain the logbook. An Installation and Commissioning guide has been supplied to your installer with this panel. Year 2000 Compliance The panels are designed in accordance with the requirements of LPS2000. Contents Page Description of main 2 controls and indicators User responsibility 3 Operating instructions 5 Log book 7 Part 2 of 4188-424 Issue 2 1 03/01

Description of main controls and indicators Fire Panels Description of main controls and indicators ZONE Fire, Fault or Disablement indications red Zones FIRE Fault System Power Earth Sounder Disabled Other Fault indications 1 2 3 4 5 6 7 Cancel System Buzzer Reset Sound Silence Alarms Alarms Essential controls 1 2 3 4 5 6 7 8 9 Display 0 Numeric keypad Display test key Shift v 8 Shift or Function key Test green Power Day/Night Access / Function Normally lit to indicate Power supply healthy The light is lit when the Function key is pressed or there is an entry to controls with coded access Figure 1 Controls and indications cd8m191 Controls (Only available when access code is entered) Numeric keypad. Allows the entry of numeric data, ie passwords, addresses, data, etc. Shift key. The shift key gives access to the main functions of the panel. Display test key. Pressing the Display Test key after entering access code#(*) will initiate a sequence which illuminates all the indicators in turn enabling the indicators to be checked. # Coded entry is only required if Cancel Buzzer or Display test functions are configured for operation at Access level 2. Cancel Buzzer. Pressing the Cancel Buzzer button after entering access code#(*) will stop the internal buzzer sounding. System Reset. The system reset key when pressed after entering access code(*) will return the system to its normal operating state. If there are uncleared fires or faults then these conditions will re-occur. Sound Alarms. Pressing the Sound Alarms button after entering access code(*) will sound all of the system alarms. Should only be pressed in an emergency or at other agreed times, ie sounder tests. Silence Alarms. Pressing the Silence Alarms button after entering access code(*) will silence the system alarms. Should only be pressed when the emergency is over. *Three digit code. Indicators. Fire. When lit indicates that the system has detected a fire. Fault. When lit or flashing indicates that there is a fault condition on the system which requires rectification. ZoneFire/Fault/Disablement. Indicates when there is a fire (red indicator lit or flashing) or a fault ( indicator flashing) on the zone applicable to the indicators. A lit indicator in conjunction with other indicators is used to indicate various disabled conditions. System Fault. This indicator when lit indicates that there is a fault in the panel s processor. Power Fault. When lit or flashing indicates that there is a power supply fault present. Earth Fault. This indicator when lit or flashing indicates that there is an Earth Fault on the system. Sounder Fault. When flashing in conjunction with a flashing fault indicator indicates a sounder fault. When lit in conjunction with the disabled indicator indicates that the sounders are disabled. Disabled. Indicates in conjunction with the sounder or the zone indicators a disabled condition. Test. When lit indicates that the panel is in Test mode. Power. When lit indicates that the panel is powered up. Day/Night. When lit this indicates that Day Mode has been enabled. Night Mode is indicated by the indicator being unlit. Access/Function. The Access/Function lamp will flash when the shift key is pressed and be lit when the coded functions are accessed. 03/01 2 Part 2 of 4188-424 Issue 2

Fire Panels User Responsibility It is recommended that the persons responsible for the fire alarm system, should become familiar with the procedures on how to operate the controls and interpret indications given at the control and repeat panels. Adequate training should also have been given from appointed personnel. Daily The British Standard code of practice for Fire detection and alarm systems for buildings, BS 5839:Part1:1988, states that the system should be inspected daily to ensure that a normal indication is given at the control and indicating equipment and that any previously indicated fault condition has received appropriate attention. a) It recommends entry into the Log Book provided of all the system events for future reference. b) The person inspecting the protected premises can ensure that the use of the area(s) inspected has not changed such that the detection and alarm devices have become inappropriate. c) The area(s) can be inspected to check that no unsafe practices that could lead to fire are being undertaken. Weekly At Weekly intervals a different Fire detector or Manual Call Point of the system should be tested to ensure the system is capable of operating under alarm condition. a) The operation of the alarm sounders should be checked, which also provides a regular reminder to those occupying the premises that there is a fire alarm system with a particular characteristic sound. b) The test should be performed at a regular time to avoid confusion between a test and a genuine fire alarm. Quarterly At quarterly intervals the system should be inspected and any work necessary should be performed by a trained maintenance engineer. User Responsibility Battery Replacement NOTE: Any servicing work on the System must be carried out by a servicing organisation. Under normal operating conditions the maintenance free lead acid batteries in the Control and Repeat panels can have a useful life of up to 5 years from the date of manufacture. NOTE: It is recommended that these batteries are replaced at 4 Yearly intervals from the date the System is first commissioned. CAUTION: The batteries should only be replaced by trained service personal. Part 2 of 4188-424 Issue 2 3 03/01

User Responsibility Testing a Manual Call Point Push the test key through the hole in the underside of the call point to engage the test cam mechanism and push to operate the cam mechanism. At this point the test key is retained in the call point and pulling it out will reset the glass. NOTE: The alarm sounders in the system will be activated by this test. To silence alarms and reset the system, see operating instructions. Replacing a broken Glass WARNING: Take appropriate precautions when clearing broken glass to prevent injury. NOTE: A weather resistant version of manual call points will have two gaskets, a Cover/glass gasket and a Spacer/cover gasket, which must be installed in their respective position. Fire Panels These procedures assume the cover on the manual call point is open and any broken glass has been cleared. a) Insert the glass beneath the opaque slider 1 and locate bottom of the glass into recess, ensure the thumb wheel is up as shown.. b) Place the test key on the cam (thumb wheel) 2. c) Fit the call point cover by hooking it into the top of the unit. Make sure that the glass is properly seated (held down). Withdraw the test key from the call point 3 and then use it to fit the screw 4 securing the cover to the back box. CALL POINT BACK BOX AND MAIN ASSEMBLY SLIDER SLIDER CAM CALL POINT COVER THUMB WHEEL FIR E BREAK GLASS 1 4 2 TEST KEY 2 HOLD ON TO THE COVER 3 Figure 2 Replacing a broken MCP glass cd8m322 03/01 4 Part 2 of 4188-424 Issue 2

Fire Panels Operating instructions Operating instructions ZONE Fire, Fault or Disablement indications red Zones FIRE Fault System Power Earth Sounder Disabled Other Fault indications 1 2 3 4 5 6 7 Cancel System Buzzer Reset Sound Silence Alarms Alarms Essential controls 1 2 3 4 5 6 7 8 9 Display 0 Numeric keypad Display test key Shift v 8 Shift or Function key Test green Power Day/Night Access / Function Normally lit to indicate Power supply healthy The light is lit when the Function key is pressed or there is an entry to controls with coded access Figure 3 Controls and indications cd8m191 Normal indications Under normal condition the panel should give a healthy indication, with only the green light lit. Power The control panel provides system security by password entry to controls. Fire Condition In the event of an automatic fire detection the indications given are: FIRE light is lit. Zones-fire light is lit. buzzer sounds continuous tone. system alarm sounders are activated if applicable, auxiliary equipment is actuated if applicable, automatic link to the Fire Brigade is initiated. After the emergency is over After emergency is over silence the alarms and reset the system: a) Enter the 3 digit code n n n to gain access to the controls. b) Press the Silence Alarms button. Notice the system alarm sounders are silenced and local buzzer sounds continuous tone. c) After the cause of the alarm has been investigated, ensure smoke and excess heat have had time to clear from automatic detectors and broken manual call point glasses have been replaced where necessary. Press the System Reset button. Notice the indications return to their pre fire status. Part 2 of 4188-424 Issue 2 5 03/01

Operating instructions Fire Panels Condition Normal indication Visual indications Zone Fire (1-8) -Red Fire Common - Red Disabled - Yellow Test - Yellow Power - Green Access/ Function - Yellow Audible indication Buzzer Sounder circuits Signals out Aux Relay contacts Normally deenergised Comm on fault - Norma lly active Comm on fire- Norma lly deacti ve On Normal Active Deact ive Fire On On On On On Change over New fire (different zone) On On On On On Change over Active Active AL2, 3 or 4 On On Normal Active Deact ive Function key press On Fast Pulse Active Active Normal Active Deact ive Indications on panel To Sound Alarms To re-sound the alarm sounders during a fire condition: a) Enter the 3 digit code n n n to gain access to the controls. b) Press the Sound Alarms button. Notice the system alarm Sounders are activated. To Silence Alarms To silence system alarm sounders after they have been actuated: a) Enter the 3 digit code n n n to gain access to the controls. b) Press the Silence Alarms button. Notice the system alarm Sounders are silenced. To carry out a display test a) #Enter the 3 digit code n n n to gain access to the controls. # Coded entry is only required if Display test function is configured for operation at Access level 2. v b) Press the shift button and then the display button. Ensure that all the LEDs light in sequence and the buzzer sounds. Fault Condition In the event of an automatic fault detection the indications given are: Fault light is lit fault indicators are lit buzzer sounds intermittent. (except for system fault which is a continuous sound) To Cancel fault buzzer a) #Enter the 3 digit code n n n to gain access to the controls. # Coded entry is only required if Cancel Buzzer function is configured for operation at Access level 2. b) After investigating fault, press the Cancel Buzzer button. Notice the buzzer is silenced but other indications remain active. The fault indications are normally automatically extinguished once the fault condition has been rectified. Action to rectify fault Suggested action to rectify fault condition: NOTE: All fault rectification work must be done by suitably qualified personnel. The fault indicators may be extinguished during a fire condition. The mains failure condition overrides all other fault indications in order to preserve battery standby capacity. NOTE: A comprehensive fault finding guide is included in the Installation and Commissioning guide. 03/01 6 Part 2 of 4188-424 Issue 2

To comply with the requirements of BS5839 : Part 1 : 1988 and to allow those concerned with the fire detection and alarm systems to monitor the long term performance of the system, it is important that a log is kept, which includes all the events relating to the performance of the system. SITE ADDRESS Log Book Contract No. Site ID: For Service Normal Hours Mon-Fri Tel. Outside Normal Hours Tel. Manned Centre Telephone Manned Centre Code No. Responsible Persons on SITE: AL2 password For each zone record the location description. Zone number Description of the zonal location Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Log book for Part 2 of 4188-424 Issue 2 7 03/01

System configuration record Fire Panels This information will assist the servicing organisation to keep a record of how the system is configured. Mark in the table below any deviation(s) from the standard factory settings. Detection and zone circuit configuration Zone number 1 2 3 8 5 6 7 8 Normal zone operation (factory setting) Non latching zone operation First fire to be a pulsing indication (factory setting) First fire to be a steady indication Zone short circuit to give a fault (factory setting) Zone short circuit to give a fire Sounders and system reset configuration Silence alarms and reset to operate independently (factory setting) Silence alarms and reset to operate as per BS5839: Part 4 Reset to also action the silence alarms Sound alarms to operate in fire condition only (factory setting) Sound alarms to operate at any time Auxiliary relay to energise with fire (factory setting) Auxiliary relay to energise with sound alarms Access level Access levels AL1 AL2 Cancel buzzer (AL1 - factory setting) Test A & B mode, Cancel Test (AL2 - factory setting) N/A Display test (AL1 - factory setting) Repeat panel information Repeat panel EEPROM location EEPROM Data (address) Name of the area where the panel is installed on site 1st Repeat panel 2nd Repeat panel 3rd Repeat panel 4th Repeat panel 03/01 8 Log book for Part 2 of 4188-424 Issue 2

Fire Panels Location of system devices Location of system devices Make copies of this page to record details of the system. This information will assist the servicing organisation to keep a record of how the system is configured. Zone Type of system device Location 1 2 3 4 5 6 7 8 Log book for Part 2 of 4188-424 Issue 2 9 03/01

Event log Fire Panels Event log Make copies of this page to record details of system events. Date Time Events Action Date complete Name 03/01 10 Log book for Part 2 of 4188-424 Issue 2

Fire Panels Event log Event log Make copies of this page to record details of system events. Date Time Events Action Date complete Name Log book for Part 2 of 4188-424 Issue 2 11 03/01

Event log Fire Panels 03/01 12 Log book for Part 2 of 4188-424 Issue 2