Fire Alarm Control Systems Simple. Smart. Reliable.

Similar documents
Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

Fire Alarm Control Systems

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

PART IV DETAILED SPECIFICATION

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center

SILENT KNIGHT IFP-1000

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

INTELLIKNIGHT Model 5808

ECC-50/100C. Emergency Command Center

Innovation that Endures

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

INTELLIKNIGHT 5820XL. Installation and Operation Manual. Addressable Fire System. Part Number H, 10/03

July 14, 1999 DF C-100.

INTELLIKNIGHT MODEL 5700

30.45 Electric Release PDRP-2001

June 10, 2002 DF C S2424

FARENHYT ORDER FORM Page 1 of 5

Addressable Fire Alarm Control Panel

E3 Series Broadband System

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 04/01/2011 Rev: S P/N L8:S ECN

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 05/09/2012 Rev: T P/N L8:T ECN

Silent Knight Software Suite Intelliknight Training

good things in small packages

D7024 Fire Alarm Control Panel

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

Version /17. Honeywell Gamewell-FCI Honeywell Security and Fire 12 Clintonville Road Northford, CT 06472

MODEL IFP-100. Installation and Operations Manual. Analog/Addressable Fire Control Panel. Part Number Rev L

FireNET Plus Wiring Instructions

INTELLIKNIGHT MODEL 5700

A World of Solutions

IFP-2000 F r a en e h n y h t y PH P D

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

LifeAlarm Fire Alarm Control Panels

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

E3 Series Broadband System

Installation and Operation Guide. EVS-Series. Emergency Voice System. Document: LS SK-E ECN:

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

4.1 Mounting the 5820 Cabinet Removing the 5820 Assembly from the Housing AC Connection Battery Connection...

Agent Release Control Panel

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Mircom FX /01/16

MODEL IFP-2000/ RPS-2000

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

INTELLIKNIGHT MODEL 5808

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

The Worldwide Fire System ANSI/UL 864 9th Edition

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

A World of Solutions in Fire Protection Systems

TECHNICAL DATA OBSOLETE

Innovative protection that combines power and flexibility

Section 8 System Operation

Unified Fire Authority - Fire Prevention Bureau

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

TrueAlarm Fire Alarm Systems

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Laptop / PC Programming Manual

4007ES Fire Control Panels

INTELLIKNIGHT MODEL 5700

The Worldwide Fire System ANSI/UL 864 9th Edition

AutoPulse. AUTOPULSE IQ-318 AGENT RELEASING CONTROL PANEL Data/Specifications

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

SMALL SCALE SOLUTIONS

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AND ARCHITECT SPECIFICATIONS

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

L-Series, Emergency Communication Devices

DS7400Xi Addressable Control/ Communicator

SP40S-D. Kingfisher Company, inc. Features: Description:

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Specification/ Data Sheet

PFC-4064 Conventional Fire Alarm Panel

TrueAlarm Fire Alarm Controls

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Integrated Security Solutions

AFP-400 Analog Fire Panel MEA E. City of Chicago Class 1: 1291E Class 2: 1792E GENERAL FEATURES. A Pittway Company

INSPECTION AND TESTING FORM

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Desigo TM Fire Safety System A comprehensive fire-protection system

Scott Barrett, President

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets...

Section 9 System Operation

Transcription:

Fire Alarm Control Systems Simple. Smart. Reliable.

PROVEN PERFORMANCE Honeywell Silent Knight Fire Alarm Systems Founded in 1961, Honeywell Silent Knight designs and manufactures commercial fire alarm and life safety systems. It leads the fire alarm industry with a broad portfolio of products with advanced features and capabilities. Perfect for both simple and complex installs, you'll find Silent Knight at security equipment distributors throughout the United States. Silent Knight s headquarters and manufacturing operations are based in Northford, Connecticut, USA. The Honeywell Silent Knight 6000 Series When Silent Knight's on guard, you won't be caught off-guard. Silent Knight fire systems offer: Over 1,100 addressable points with versatile SLC functionality Compatible with System Sensor and Hochiki devices Combination Fire Alarm Control Panel and Emergency Voice System for mass notification SWIFT Class A mesh wireless detection Ability to connect addressable panels for single point viewing Thorough classroom/on-line training, technical services, Jumpstart autoprogramming, SKST configuration and HFSS tools 2 Protecting what matters most

Addressable Fire Alarm Control Panels (FACPs) Silent Knight 6000 Series Features 6700 6808 6820 and 6820EVS Up to 100 points for small sized installations Up to 198 points for medium sized installations Up to 1,110 points for large installations or complex projects For more information on the 6820EVS see Pages 8-9. Shared Features and Specifications Field upgradeable firmware Connect up to 17 panels with convenient single panel visibility of all connected panels Built-in IP/POTs and optional cellular communicators SWIFT wireless detection Supports Class B and Class A configurations Distributed, intelligent power Three Form C relays: one trouble and two programmable. Rated at 2.5 amps at 24 VDC. Automatic drift compensation Detector status to perform a NFPA 72-compliant sensitivity check Built-in synchronization for System Sensor, Wheelock, Gentex, and AMSECO Built-in digital communicator (DACT) ADDITIONAL FEATURES AND SPECIFICATIONS 6820 and 6820EVS 6808 6700 MAX ADDRESSABLE POINTS - SK (SYSTEM SENSOR) DEVICES 1,110 198 100 MAX ADDRESSABLE POINTS - SD (HOCHIKI) DEVICES 635 127 50 NOTIFICATION APPLIANCE CIRCUITS 6 (expandable to 56) 4 (expandable to 36) 2 (expandable to 34) POWER SUPPLY 6A 6A 2.5A SMOKE VERIFICATION ü ü ü ANSI 3.41 (TEMPORAL) CADENCE ü ü ü UP/DOWNLOADABLE (IP ONLY) ü ü ü BUILT-IN RELAY OUTPUTS 3 3 3 MAX REMOTE ANNUNCIATORS 16 12 8 BUILT-IN 80-CHARACTER LCD ü ü ü ALARM REPORTING BY POINT OR ZONE ü ü RS-485 ACCESSORY COMM BUS ü ü ü BUILT-IN SERIAL INTERFACE TO PROGRAM VIA PC ü ü ü PROGRAMMABLE FOR DAYLIGHT SAVINGS TIME ü ü ü NON-VOLATILE, 1000-EVENT HISTORY BUFFER ü ü ü CUSTOMIZABLE TEXT LABELS FOR DEVICE AND MODULES ü ü ü WATER DELUGE RELEASING SERVICE ü ü ü 3

6820 System Example Example of a complete FACP system using a 6820 FACP. Includes detectors, AV notification appliances, Flexputs, SLC expanders, SWIFT wireless and other devices. Fire Department Central Station 6815 SLC SK-BEAM SK-DUCT HFSS 6820 FACP with IP/POTs 5895XL Power Supply Cellular Connection CELL-CAB-SK SWIFT 6815 SLC SLC SBUS 6860 6855 6815 SLC 6815 SLC WSK-WGI W-USB PC2WL Ceiling-Mount Flexput* Horn Strobe HRL Wall-Mount Horn AV NOTIFICATION PC2RL Ceiling-Mount Horn Strobe OUTPUT SK-RELAY Relay Module SBUS WSK-PHOTO WSK-PHOTO-T 2W-B Photoelectric CONVENTIONAL DEVICES CO1224T CO INPUT SK-ZONE Zone Interface Module 5496 6 Amp Power Module WSK-HEAT WSK-HEAT-ROR SK-FIRE-CO B200S-LF Multi-Criteria Fire/CO with Low Frequency Sounder Base SK-PHOTO-W Photoelectric DETECTORS SK-HEAT-W Fixed Thermal SK-ACCLIMATE Multi-Criteria Photoelectric Thermal SK-CONTROL-6 Supervised Control Module SK-MON-10 Addressable Multi-Module 5460R Remote Annunciator 5880 LED Driver and Input Module WSK-MONITOR WSK-RELAY SK-MINIMON Monitor Module SK-MONITOR Input Module SK-ISO Fault Isolator Module SK-PULL-DA SK-PULL-SA SK-RELAYMON-2 Two In/Two Out Module 5883 Relay Interface Module DEVICES * Flexput Circuits are input or output circuits that can be programmed for NACs, conventional input circuits, or auxiliary power - constant power, door power, or resettable smoke power. Versatility without the cost of additional modules. Also useful for retrofitting existing systems. 4

ADDRESSABLE FIRE ALARM DEVICES Detectors, Modules, Pull Stations, Annunciators, Power Supplies and More Silent Knight's addressable detectors, modules, pull stations, annunciators and power supplies are specifically engineered to ensure your installs and maintenance are simple and efficient. Silent Knight addressable FACPs support both System Sensor (SK) and Hochiki (SD) devices although SK and SD devices cannot be mixed together within the same system. Silent Knight routinely adds new devices to its offering. For the most up-to-date product listing, visit www.silentknight.com. SK Devices B200S Intelligent Sounder Base B200S-LF Intelligent Low Frequency Sounder Base B200SR Sounder Base B200SR-LF Low Frequency Sounder Base B210LP Intelligent 6-Inch Detector Base B224BI Isolator Base B224RB Relay Base B501 Intelligent 4-Inch Detector Base ISO-6 Six Fault Isolator Module SK-ACCLIMATE Multi-Criteria Photoelectric Detector With Thermal Sensing SK-BEAM Single-Ended Reflected Beam Detector SK-BEAM-T Single-Ended Reflected Beam Detector With Integrated Sensitivity Test SK-CONTROL Supervised Control Module SK-CONTROL-6 Six Circuit Supervised Control Module SK-DUCT Photoelectric Duct Detector SK-FIRE-CO Combination Fire And CO Detector SK-HEAT 135 F Fixed Temperature Heat Detector SK-HEAT-HT 190 F Fixed High Temperature Heat Detector SK-HEAT-HT-W 190 F Fixed High Temperature Heat Detector (White) SK-HEAT-ROR 135 F Fixed Temperature Rate of Rise Heat Detector SK-HEAT-ROR-W 135 F Fixed Temperature Rate of Rise Heat Detector (White) SK-HEAT-W 135 F Fixed Temperature Heat Detector (White) SK-ISO Fault Isolator Module SK-MINIMON Mini Monitor Module SK-MON-10 Ten Input Monitor Module SK-MONITOR Monitor Module SK-MONITOR-2 Dual Monitor Module SK-PHOTO Photoelectric Detector SK-PHOTOR Remote Test Capable Detector for DNR/DNW SK-PHOTO-R-W Remote Test Capable Detector for DNR/DNW (White) SK-PHOTO-T Photoelectric Thermal Detector SK-PHOTO-T-W Photoelectric Thermal Detector (White) SK-PHOTO-W Photoelectric Detector (White) SK-PULL-DA Addressable Dual Action Pull Station SK-PULL-SA Addressable Single Action Pull Station SK-RELAY Relay Control Module SK-RELAY-6 Six Relay Control Module SK-RELAYMON-2 Intelligent Dual Monitor/Relay Module SK-ZONE Zone Interface Module SK-ZONE-6 Six Zone Interface Module SD Devices SD500-AIM Addressable Input Module SD500-ANM Addressable Notification Module SD500-ARM Addressable Relay Module SD500-LIM Loop Isolation Module SD500-MIM Mini-Input Module SD500-PS/PSDA Single or Dual Action Addressable Pull Station SD500-SDM Smoke Detector Module SD505-4AB/SD505-6AB Four/Six-Inch Detector Base SD505-6IB 6-Inch Isolator Base SD505-6RB 6-InchAddressable Relay Base SD505-6SB 6-Inch Addressable Sounder Base SD505-DTS-K Addressable Duct Detector Test Switch SD505-DUCT Addressable Duct Housing SD505-DUCTR Addressable Duct Detector with Built-In Relay SD505-HEAT Addressable Heat Detector SD505-PHOTO Addressable Photoelectric Detector Audible/Visible Devices Most of our AV devices are available in red or white. Part numbers with an "R" indicate red and "W" white. For more AV options visit www.silentknight.com. CHSRL/CHSWL Wall chime/strobe CHSCRL/CHSCWL Ceiling chime/strobe CHRL/CHWL Wall chime HRL/HWL Wall horn P2RL/P2WL Wall horn/strobe P4RL/P4WL Wall horn/strobe (4-wire) PC2RL/PC2WL Ceiling horn/strobe PC4RL/PC4WL Ceiling horn/strobe (4-wire) SRL/SWL Wall strobe SCRL/SCWL Ceiling strobe SPSCRL/SPSCWL Ceiling speaker/strobe SPSRL/SPSWL Wall speaker/strobe SPRL/SPWL Wall speaker SPCRL/SPCWL Ceiling speaker SWIFT Wireless Detection Uses SK Protocol WSK-HEAT Fixed Heat Detector WSK-HEAT-ROR Rate-of-Rise Heat Detector WSK-MONITOR Monitor Module WSK-PHOTO Photo Detector WSK-PHOTO-T Photo/Thermal Detector WSK-RELAY Relay Module WSK-WGI Gateway W-USB SWIFT Tools USB Transceiver Other Devices 5496 Addressable Power Supply 5815XL Signaling Line Circuit for SD Devices 5824 Serial/Parallel Module 5860/5860R Remote LCD Annunciator 5865-3/5865-4 Remote LED Annunciator 5880 LED Input/Output Module 5883 Relay Interface Board 5895XL Intelligent Power Module 6815 Signaling Line Circuit for SK Devices SK-FML Fiber Optic Card (Multi-Mode) Transmitter/Receiver SK-FSL Fiber Optic Card (Single-Mode) Transmitter/Receiver SK-NIC Network Interface Card SK-NIC-KIT Accessory Cabinet for SK-NIC SK-SCK Seismic Compliance Kit 5

Remote Annunciators and SWIFT Wireless Devices Remote Annunciators Silent Knight remote annunciators are an indispensable part of any fire system. They can be used to operate and program the FACP from additional locations within the system. In addition to status messages displayed on the LCD, there are LEDs for alarm, supervisory, trouble, silence, and AC power status. On-board piezo sounders audibly indicate alarms, troubles and supervisory conditions. Remote annunciators communicate with the FACP through an RS-485 connection with wiring up to 6,000 feet from the panel, and they can be flush or surface mounted. When surface mounted, trim rings are available for a seemless look between the wall and annunciator. 6860 Large 160-character LCD display (4 lines, 40 characters per line) Four programmable function keys free-up time spent at the panel executing routine tasks Lock and key for secure access Surface mount trim ring (RA-100TR) SWIFT Wireless Detection SWIFT (Smart Wireless Integrated Fire Technology) devices seamlessly integrate with existing or new wired installations, providing a unique level of reliability through smart, true mesh technology. With redundant paths of communication, if a wireless path is disrupted, the system automatically heals itself, providing Class A system reliability. 6855 80-character LCD display (4 lines, 20 characters per line) Lock and key for secure access Surface mount trim ring (RA-100TR) 5860R 80-character LCD display (4 lines, 20 characters per line) Access via firefighter s key or access code. Special installation code required for programming functions. Surface mount trim ring (5860TR) SWIFT is ideal for hard-to-wire locations, buildings where new wiring is not allowed, or for retrofit and temporary applications. Compatible with 6000 Series panels, using SK protocol, with the WSK-WGI gateway communicating via the SLC. SWIFT Wireless Detection Uses SK Protocol WSK-HEAT Fixed Heat Detector WSK-HEAT-ROR Rate-of-Rise Heat Detector WSK-MONITOR Monitor Module WSK-PHOTO Photo Smoke Detector WSK-PHOTO-T Photo/Thermal Detector WSK-RELAY Relay Module WSK-WGI Gateway W-USB SWIFT Tools USB Transceiver 6

Application Examples From connecting panels, to utilizing emergency communication systems and SWIFT devices, here are a few examples of how Silent Knight products can be used for specific applications. Integrated FACP and Emergency Voice Systems Housed in one panel with associated peripherals; meets UL 2572 requirements for mass notification. Consider this set-up: 6820EVS, EVS-LOC, EVS-125W, SPSWL, SK-PULL-DA, SK-FIRE-CO, SK-DUCT, 5860, and CELL-CAB-SK Integrating Wireless Solutions Integrate SWIFT wireless devices where wiring is discouraged or impractical places of worship, historical structures, or complex pre-wired sites. SWIFT is also ideal for easy-install fire protection in unfinished structures. Note that SWIFT operating temperatures are 32ºF-122ºF. Consider this set-up: 6808, WSK-WGI, WSK-PHOTO, WSK-PHOTO-T, WSK-HEAT, WSK-HEAT-ROR, and WSK-MONITOR Fire Systems for Connected Buildings Improve access to critical indicators while lowering monitoring fees by connecting the fire system using fiber optic or copper wire with one panel handling communications for all connected panels. Central Station communications can be initiated using Contact ID with Alarmnet, or SIA protocols. Consider this set-up: 6820, 6808, 6815s, SK-NIC, SK-FML, SK-FIRE-CO, SK-ACCLIMATE, SK-DUCT, SK-PULL-DA, P2WL, SRL, 6860, and CELL-CAB-SK Conventional Fire Systems Designed for small or open buildings where locating precise fire spots is not paramount, but the budget is. Also useful for monitoring sprinkler systems. Consider this set-up: SK-5208, PS-DA, and an assortment of conventional devices 7

Emergency Voice Systems Silent Knight's Emergency Voice System (EVS) product line is a fire and emergency mass notification system conveniently integrated and housed in a single panel, and meets the requirements for mass notification as described in UL 2572. This combination is useful for managing fire and non-fire events where life safety and property protection depends upon clear and timely communications. Silent Knight's Emergency Voice System (EVS) includes the 6820EVS panel, optional amplifiers, an operator's console, fire fighter telephone system and a wide variety of alarms and audio visual devices. The panel has an on-board supervised microphone, and all call and non-active call buttons that can quickly select all active or all non-active output groups. The system also lets you select an EVS message as a priority over fire. The FACP has 16 built-in speaker group switches - expandable to 32, and 15 recordable one minute messages that can be mapped to eight different EVS buttons. It has a built-in annunciator with a 160-character (4 line, 40 character) LCD display, and four programmable buttons that can be programmed as needed to minimize time spent executing complex or routine tasks. This system will help keep those impacted informed of both fire and non-fire emergencies, with real time information and guidance. Emergency Voice System Application SPCWL SPCRL SWL SPCW8 Audible Visible Notification EVS - 125WAmplifier SK-PHOTO-W SK-FIRE-CO SK-HEAT-W 6820EVS Fire Alarm Control Panel and Emergency Voice System SK-PULL-DA P2RL SPSWL Detection and Notification on an SLC Loop HRL EVS-LOC Remote Command Unit 8

EVS-LOC Combination supervised remote microphone and annunciator compatible with the 6820EVS Makes access to the communication system easier when immediate and timely communications are essential Up to four EVS-LOCs can be added to a compatible emergency voice system SKE-450 Voice evacuation system that delivers clear voice messages 50 watts, built-in digital message repeater, power supply, and two alarm inputs Message repeater, power supply, and two alarm inputs Field programmable messages and fully supervised speaker circuits SK-FFT Fire Fighters Telephone Communication System Control and annunciation of up to 48 remote fire fighter telephone jacks with intuitive LEDs that help you locate trouble quickly A maximum of 10 fire fighter remote handsets can be used at one time 6820EVS Fire alarm control panel with integrated emergency voice communication system Large 160 character (4 lines x 40 characters) display Four programmable buttons save time at the panel executing routine and complex tasks Up to 1,110 points (SK Protocol); 635 (SD Protocol) Integrated IP/POTs and optional cellular side-cars On-board microphone, 16 speaker groups (expandable to 32), and up to 15 recordable messages Supports up to four EVS-50W, EVS-100W or EVS-125W amplifiers; maximum of 500 watts. Each amplifier has four built-in speaker circuits expandable to eight. For more information see Pages 3 and 8 Three options for audio amplification: EVS-50W 50 watt amplifier EVS-100W 50/100 watt amplifier with built-in backup EVS-125W 125 watt amplifier Additional Accessories EVS-INT50W 50 Watt internal amplifier EVS-CE4 Circuit Audio Expander EVS-SW24 24 Switch Expander EVS-VCM Voice Control Module 9

Power Supplies 5499 and 5495 Distibuted Power Supplies The 5499 (9 Amps) and 5495 (6 Amps) notification power expanders provide AC power connection, a battery charging circuit and backup battery support for compatible fire alarm control panels. Their switch mode power supply design is up to 50% more efficient than linear mode power supplies. They include built-in synchronization for appliances from System Sensor, Gentex, Wheelock and others. POWER SUPPLY FEATURES FEATURES 5499 5495 Power Output 9A/24VDC 6A/24VDC Number of Outputs 4 + Aux 4 + Aux Maximum Output per CKT 3A 3A Auxillary Power Output 3A 3A Ground Fault Detection ü ü Trouble Relay ü ü Standalone Operation ü ü ANSI 3.41 (Tempoal) Cadence ü ü Activation-->>Reverse Polarity/Contect ü ü Class A or B Operation ü ü Fire Communicators CELL-MOD and CELL-CAB-SK Designed to integrate directly with Silent Knight 6000 Series panels, these HSPA+ (4G) communicators do not require special programming or a dialer capture module and utilize the battery backup provided by the fire alarm control panel. They are useful for dual path reporting when combined with integrated panel IP communications and are remote mountable up to 6000 feet from the FACP so they can be positioned to receive the best cellular signal. CELL- MOD Cellular Side-Car (Plastic Housing) CELL-CAB-SK Cellular Side-Car (Metal Housing with Lock/Key) IPGSM-4G Communicator Fire alarm communicator that offers Contact ID reporting Provides single or dual path communications through three selectable reporting paths - cellular, IP or IP primary/cellular backup Connects directly to the communication ports of the FACP digital alarm communicator transmitter (DACT) Communications are sent to the AlarmNet Network Control Center 10 5104 Digital Fire Communicator A six-zone stand-alone or adjunct communicator (Universal Digital Alarm Communicator Transmitter) reporting through POTs lines Can be used as a stand-alone sprinkler supervisory control panel for supervised waterflow bell output Six fully supervised inputs including one Class A and five Class B SK-IP-2 Remote reporting via the Internet. Requires a VisorAlarm receiver at the central station. Metal enclosure mounts next to the FACP Two supervised inputs and two additional outputs

Conventional Fire Alarm Control Panels Silent Knight conventional fire alarm control panels include basic 2 to 10 zone panels, with optional zone expansion, remote annunciators, pull stations and related accessories. Built-in synchronization for System Sensor, Wheelock, Gentex, and AMSECO. All zones are compatible with listed 2- or 4-wire smoke detectors. CONVENTIONAL FEATURES SK-5208 SK-4 SK-2 Number of Class B Zones 10 (exp. to 30) 4 2 Notification Appliance Circuits 4 2 1 Power Supply (24VDC) 6.0A 2.5A or 5.0A 2.5 Alarm Verification ü ü ü ANSI 3.41 (Temporal) Cadence ü ü ü Up/Downloadable ü Communicator ü Optional Optional Built-In Relay Circuits 4 3 2 Remote Annunciator LCD LED Auxiliary Power 1.0A 0.5A 0.5A SK-5208 Ten zone panel (expandable to 30), LCD display and programmable touchpad Supervised zone expanders and I/O modules can be mounted remotely from the main control SK-4 Four zone panel Form C alarm, supervisory and trouble relays Optional module converts all 4 IDCs and 2 NACs to Class A Silent or audible walk test operation Disable switches provided per zone SK-2 Two zone panel Form C alarm and trouble relays Silent or audible walk test operation Disable switches provided per zone Accessories SK-5208 Accessories SK-5217 10-Zone Expander SK-5235 Remote LCD Annunciator SK-5280 Status Display Module 5660 Silent Knight Software Suite (SKSS) (available on website only) 5824 Serial/Parallel Module SK-4 Accessories SK-DP2/4 Dress Panel SK-4RB Repair Board SK-CAC4 Class A Converter SK-4XTM Transmitter Module SK-4XLM LED Interface Module SK-XRM24 110 Volt Transformer 3-6A SK-RZA4 Remote Annunciator SK-4XZM Zone Relay Module TR-1-R Semiflush Mount Trim Ring SK-DP2 Accessories SK-DP2/4 Dress Panel SK-2RB Repair Board SK-4XTM Transmitter Module RBB Remote Battery Box Accessory Cabinet TR-1-R Semiflush Mount Trim Ring Conventional Pull Stations Can be reset with Silent Knight enclosure keys. Optional surface mount back boxes. PS-SATK Single Action Metal (Weatherproof) PS-DATK Dual Action Metal (Weatherproof) PS-SA Single Action Lexan PS-DA Dual Action Lexan PS-DASP Dual Action Spanish Language Lexan PS-DAH Dual Action Hex Key Lexan PS-DALOB Dual Action Listed Outdoor w/back Box Lexan PS-DATK PS-DA 11

For more information, visit: www.silentknight.com Contact our sales team: www.silentknight.com/salesmap Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 350920-L8 Rev B 03/18 2018 Honeywell International Inc.