INSTALLATION INSTRUCTION & OWNER S GUIDE

Similar documents
READ CAREFULLY AND SAVE R3

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Limited Lifetime core warranty. 5-year warranty on balance of unit.

SAFETY AND INSTALLATION MANUAL MODEL 8100

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

READ AND SAVE THESE INSTRUCTIONS

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

NU800, NU1200 & NU1600

Installation & Owner s Manual

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Heat Recovery Ventilators models:

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

VERTICAL FAN COIL UNITS

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

CVS Model Inline Multi-Port Ventilators

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Outside Air Requirements... SOLVED!

Instruction Manual Item No.: V~, 60Hz

5) Do not start or stop the unit by inserting or pulling out the power plug.

Indirect Gas-Fired Make-Up Air

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Portable Dehumidifier with Internal Pump

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Bathroom Exhaust Fan

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

DBF 4XL Dryer Booster Fans

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Model 1820 Dehumidifier

Indoor Air Quality Product Brochure.

Superdryer Dehumidifiers

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Address of your installer

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

DUST FREE CARBON Whole House Air Purifier

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

SLIDER CASEMENT AIR CONDITIONER

Quest Dry 105, 155, and 205 Dual

INSTALLATION MANUAL AND USER GUIDE

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

GL-DEH Series Portable Dehumidifier Operating Instructions

e Bath Fan with Light User s Guide

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER

Indoor Air Quality Product Brochure.

12,000 BTU Evaporative Portable Air Conditioner

Portable Dehumidifier

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

ROTARY CONTROL AIR CONDITIONER

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

TR Series - The Ultimate ERV

Modular Supply Make-Up Air Unit

READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Installation & Owner s Manual

SH, VH & SE Series. Installation, Operation and Maintenance Manual. Heat & Energy Recovery Ventilators SH 704 VH 704 SE 704

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Put the V back in HVAC

INSTALLATION INSTRUCTIONS USER GUIDE

e Bath Fan with Light User s Guide

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.


10-year industry best core warranty. 5-year warranty on balance of unit.

PORTABLE AIR CONDITIONER OWNER S MANUAL

Transcription:

INSTALLATION INSTRUCTION & OWNER S GUIDE 448 S. Main Street - P.O. Box 930040 - Verona, WI 53593-0040 Phone (608) 845-6411 - Fax (608) 845-6504 - carnes@carnes.com Air Exchanger with Heat Recovery Light Industrial Model WPDB07B - WPDB11B Model WPDB07H - WPDB11H Read carefully and save these instructions.

a 1 WELCOME Table of contents 1 Welcome a Table of contents...2 b Introduction...3 c Air exchanger with heat recovery...3 2 Installation preliminaries a Box contents...4 b Installation kit contents...4 3 Location a Of the unit... 5 b Of inlet grilles...5 c Of diffusers...5 d Of the humidity control...5 4 Installation a Of the unit... 6 b Of the exhaust louver...6 c Of the inlet louver...6 d Of the humidity control...6 e Of the ductwork...7 f Air balancing...7 g Unit connection... 8-9 h Unit configuration...10 5 Operation a Unit...11 b Humidistat...12-15 c Timer...16 d Maintenance...16 6 General information a Technical sheet for Model WPDB07B... 17-18 b Technical sheet for Model WPDB07H... 19-20 c Technical sheet for Model WPDB11B...21-22 d Technical sheet for Model WPDB11H... 23-24 e Warranty...25 f Additional information...26 g Product information...26 Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 2

1 WELCOME b Introduction You are now the proud owner of an exchanger. Carnes would like to thank you for purchasing this unit which, if you carefully follow the instructions in this guide, will provide you with years of comfort. First fill the product information section at the end of this guide. The data is necessary for any claim regarding the warranty. c Air exchanger with heat recovery This unit is specially designed to change the in your home. This exchanger will ensure continuous ventilation on request. In winter, it will dehumidify the ambient to the level set on the control. Odors will also be exhausted and the life span of your house will be extended. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 3

2 INSTALLATION PRELIMINARIES a Box contents Check if all the parts are included in the package. b Air exchanger Bag of pieces - 2x 3/8 & ½ universal drain - 2x Seal brommets - 2x Drain taps - 1x Drain hose T connector - 12 drain hose Installation kit contents Additional parts can be bought to complete the installation. The following parts are recommended for a standard installation. Humidistat Cable for humidistat Inlet and exhaust louver Inlet grille or diffuser Insulated duct Non-insulated duct Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 4

3 LOCATION a Of the unit The Carnes unit should be installed in an area where the temperature is always above the freezing point. The best location for the unit would minimize the total duct length and the number of elbows. The shorter the ducts and the fewer elbows there are, the higher the flow will be. b Of inlet grilles The ambient inlet grilles should be mounted close to areas with high humidity levels. Most of the time, they are located in the corridor between the kitchen and the washroom on the ground floor and close to the washroom in the basement. It should not be located in a room containing a combustion appliance like a furnace or a fireplace. The grilles can be installed on the ceiling or a wall. Place the grille within 12 (30cm) of the ceiling. c Of diffusers The diffusers are normally installed in corridors as far from the ambient intake as possible. This forces the to circulate through most of the house. The diffuser can be installed on a wall or on the ceiling. If it is located in an occupied area, we recommend mounting the diffuser on the ceil - ing. This allows the fresh to be mixed with the ambient before reaching the occupants, thus improving the comfort level during a cold winter day. A wall-mounted diffuser should be located within 12 (30 cm) of the ceiling. d Of the humidity control The control has to be installed where excess humidity is more likely to be detected. On the ground floor, this place is generally located between the kitchen and the bathroom. If you wish to control the humidity level mainly in the basement you should install the control in this area. Avoid placing the humidistat in an area with stagnant, for example behind a door. The installation of the exchanger must be in accordance with the applicable codes in your area. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 5

4 INSTALLATION a Of the unit The unit is designed to be installed on a shelf or suspended to the structure. When the unit is on a shelf, it is necessary to have some vibration isolators under its casing to prevent the propagation of noise. The exchanger must be leveled horizontally. This is necessary to drain the condensation out of the unit. A drainage pipe should join the connection in the bottom of the casing to the building drainage system. b Of the exhaust louver The exhaust louver is installed through an exterior wall at 4 (10 cm) minimum above ground. Attach the intermediary sleeve to the plastic louver collar with a crew. Seal the gap between the sleeve and the wall. c Of the inlet louver The inlet louver is installed through an exterior wall, at more than 6 (185 cm) from the exhaust louver and more than 18 (46 cm) above ground. Make sure the inlet louver is installed so the insulated vent duct, joining it to the cabinet, is as straight as possible. d Of the humidity control The control should be mounted on the wall, 5 (150 cm) above the floor. Drill a hole through the wall so you can pass a wire from the control to the unit. This wire contains 4 wires in different colors. Connect them to the wires coming out of the unit. Follow the color code. The wires are at 24V. Attach the back part of the control to the wall. Install the plastic cover with the help of the fixing screw and the control button. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 6

4 INSTALLATION e Of the ductwork To maximize the exchanger flow, install the ducts as straight as possible. We recommend galvanized steel ducts for long ductwork be - cause of their ease of cleaning and low flow resistance. You can run ducts through floors, ceilings, walls or closets and cover them thereafter with gypsum board. Ducts in unheated areas must be insulated. The last 3 (m) of the exhaust duct adjacent to the exhaust louver should be insulated and covered with a vapor barrier. Refer to page 18 to 25 to find where the ducts can be connected to the unit. Slide end of flexible duct over unit port. Wrap 2 (5cm) wide tape around duct. If necessary, the gaps between ducts and walls or ceilings can be hidden with the rubber strips. f Air balancing The supplied through the diffuser should be warmer than 54 F (12 C). Colder would make people uncomfortable and create condensation on ducts surfaces. Balancing dampers should be installed in all the exchanger ducts. They must be adjusted so the supplied temperature is higher than the temperature stated above all year round. The difference between the exhaust and supply flow rates should be negligible (below 10%). Airflows balancing are especially important in houses with combustion appliances or in area where soil gas is deemed to be a problem. Use flow measuring stations and a magnetic gage to measure the flow rates. The speed of each blower can be independently adjusted by turning the adjustment knob located on the top of the electrical box. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 7

g 4 INSTALLATION Unit connection Wall mounted accessories The wall mounted accessories must be installed on the wall at approx. 5 (150cm) from the floor and connected to the device according to the following illustration. VERT G REE N VERT G REE N R OUG E R E D NOIR BLACK For the connection of the humidistat 611224 or DRY CONTACT, see the following illustrations according to the installation needs. WITHOUT recirculation option WITH recirculation option Option 1: the unit is in EXCHANGE mode at DEFAULT SPEED Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 8

4 INSTALLATION Option 2: the unit is in RECIRCULATION mode at DEFAULT SPEED Synchronization contact The unit disposes of a dry contact either NO or NC for synchronization with a pulsated system or other. Occupancy Control This dry contact offers a unit operation priority control; it can be used to connect a programmable timer or a motion detector to limit the unit s operation periods. When this contact is activated, the unit functions normally according to the mural accessories. Supply and exhaust damper These contacts make it possible to feed two damper actuator; one for the supply streams and one for the exhaust streams (24VAC, 10VA max each). Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 9

4 INSTALLATION h Unit configuration It is possible to change the defrost parameters and speed range using the jumper on the configuration port. The configuration port is located on the control board as indicated on the figure below. 2 4 6 8 10 1 3 5 7 9 Configuration port EXTENDED DEFROST Option For the severe applications, it is possible to extend defrost period in order to prevent ice build-up in the unit. To activate the extended defrost option, add a jumper on the configuration port between terminals 1 and 2 (DEGIVRAGE position). 2 4 6 8 10 1 3 5 7 9 REDUCED SPEED Option To operate the unit according to the REDUCED speed range (see data sheet for performance), add a jumper on the configuration port between terminals 3 and 4 (OPTION 0 position). 2 4 6 8 10 1 3 5 7 9 Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 10

5 OPERATION a Unit This heat/energy recovery ventilator is the ideal powerful unit for spacious homes, businesses, daycare centers, clinics, bars, restaurants, etc. The unit will function according to the speed selected using the button located on the side of the device (see figure below). A pilot light indicates selected speed. This speed is called DEFAULT SPEED or speed ; it is the speed to which the unit operates when no signal is emitted by the various mural accessories (humidistat, timer, etc) connected on terminals 1 to 5. When a signal is emitted by one of the mural accesso - ries, the unit is activated at HIGH SPEED or speed VERT AMBRE ROUGE B B B B VERT G REE N VERT G REE N OUG E R R E D NOIR BLACK Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 11

5 OPERATION b Humidistat The humidistat controls the relative humidity rate. Equipped with a humidity sensor and on electronic system, it efficiently controls your exchanger to keep the humidity rate in your home below the desired setting. This feature allows you to set the functioning mode of your exchanger according to your needs. You can create a continuous exchange with the outside, recirculate ambient or maintain a constant flow of fresh when there are more people in the house. The humidistat is designed to quickly evacuate all excess humidity. When the humidity content exceeds the desired setting, this features causes to be exchanged with the outside at a high speed until the humidity has been returned to the desired rate. Afterwards, it will automatically come back to the chosen operating mode. ASHRAE* standards recommend maintaining a relative humidity rate between 30% and 60%. *(American Society of Heating-Refrigerating and Air Conditioning Engineer) RECOMMENDED HUMIDITY RATE TO PREVENT INDOOR CONDENSATION Outside temperature 10 C / 50 F 0 C / 32 F -10 C / 14 F -20 C / -4 F -30 C / -22 F Recommended humidity rate Between 55 % and 60 % Between 50 % and 55 % Between 45 % and 50 % Between 40 % and 45 % Between 30 % and 40 % *These rates may vary according to the type of construction and fenestration of your house. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 12

5 OPERATION Humidistat model 611224 The mechanical humidistat controls excess humidity. When the rate of humidity is greater than the value indicated on the adjustment knob, activate the high speed switch and if needed, the interior-exterior exchange switch. When the appropriate humidity rate is reached, the humidistat returns to its pre-selected ventilation mode. Turn the adjustment knob from the humidity s higher value toward its lower value and, when you hear a click, look at the value indicated. This value represents the rate of ambient moisture in the. You may also wish to operate the appliance at high speed. To do this, adjust the knob to its lowest rate of humidity (20%). This setting is recommended for a room full of guests or an extended period of cooking. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 13

5 OPERATION Model 611227 Electronic humidistat with liquid crystal display. Liquid crystal display Humidity setting/ speed selection Mode selection Presentation of the display window Humidity setting Relative humidity rate Excess of humidity Blower speed Functioning modes Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 14

5 OPERATION - To adjust the highest humidity setting, use the until you reach the desired level. This symbol will be displayed during adjustment. - Wait several seconds and the relative ambient humidity level will again displayed. - If the humidity rate exceeds the highest set level, the symbol will appear and the exchanger will evacuate the excess humidity. However, if you set the functioning to *OFF*, excess humidity will not be evacuated from the house. (Please see Section 5) Presentation of the exchanger s functioning modes To select one of the available functioning modes for your exchanger, press the *mode* button until the mode you desire is displayed. According to the chosen mode, you must adjust the speed of the fans by pressing the up or the down ar - row. Once your selection has been choosen, don t touch the device for several seconds. This allows it to return to a normal display. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 15

5 OPERATION c Timer (Product #611228) Function: Provides the ventilation unit with high-speed exterior exchange for the following durations: 20 minutes 40 minutes 60 minutes d Maintenance WARNING: Always disconnect the exchanger from its power source before attempting any operation inside the unit Check regularly that the inlet screen and the exhaust screen are not obstructed by ice or particles. In winter, check every month that the condensate drain opening is not blocked. Filter to be cleaned with soapy water 3 times a year or when needed. ATTENTION : Optional high efficiency and charcoal filter are NOT wash - able Clean the heat recovery core in the Carnes unit once a year or when needed. Pull out gently the core from the unit. Wear gloves when you handle the core since it can have sharp angles. Vacuum cabinet interior at least once a year preferably at the beginning of fall. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 16

6 GENERAL INFORMATION a Technical sheet for Model WPDB07B WPDB07B The WPDB07B is a heat recovery ventilator of 700 CFM. This heat recovery ventilator is the ideal powerful unit for spacious homes, businesses, daycare centers, clinics, bars, restaurants, etc. The WPDB07B is the ultimate solution to prevent excess humidity and improve quality. Optional version with recirculation system is available. High performance flow Silent Highly cost effective and cost efficient Norms and certifications Conformity to Norm : 1. C22.2 no113 2. UL 507 Certified Casing Material : Pre-painted steel 22GA Insulation : 1 foil faced fiberglass Drain connection : Ø3/8 or Ø ½ Duct diameter: 8 in x 14 in Height : 23 7/8 in Width : 36 1/4 in Depth : 32 1/4 in Weight : 150 lbs Blowers Number : 2 Type: backward curved centrifugal fans Mount Suspended by chains with anti-vibration springs or on a shelf Electrical Specifications Tension : 120 VAC 230 VAC Frequency : 60 Hz Amperage : 5.5 A 2.9 A Power : 660 Watt Electrical wiring : Extension cord (120VAC; WPDB07B-A) Field wired (230VAC; WPDB07B-B) Control Low voltage dry contact (24 VAC 20Va) for : Occupancy control (start / stop) Speed selection Exchange / recirculation (optional) 24VAC 10VA output for : Supply damper Exhaust damper Compatible with : Liquid crystal display electronic humidistat (no 611227) Mode Control (exchange or recirculation) (no 611230) Humidity Control (no 611224) Speed Control (intermittent, high or low speed) (no 611229) Timer (no 611228) Defrost Cycles Controlled by a temperature sensor By exhaust only By recirculation (optional) DEFROST CYCLE TEMPERATURE Outside temperature Standard Extended Celsius Fahrenheit min def/vent min def/vent t > -5 t > 23 n.a. n.a. -5 > t > -25 23 > t > -13 7/25 10/20-25 > t -13 > t 10/22 10/15 Filters Number : 4 Type (standard) : Washable, aluminum (no 683901) Options and restriction Airflow (CFM) MERV 8 Charcoal High-Efficiency 300 0,03 0,03 0,03 500 0,08 0,08 0,08 700 0,15 0,15 0,15 Dimensions : 13 3/4 in X 15 in X 7/8 in Recovery Core Material : Aluminium Performance certified : Quantity : 2 Dimensions : 12 in X 12 in X 15 in Step : 2.5mm Warranty Appliance : limited 2 years Core Assembly : limited 15 years Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 17

6 GENERAL INFORMATION WPDB07B VENTILATION PERFORMANCE WPDB07B WPDB07B (%) Efficiency (inh2o) Pressure DIMENSIONS Recirculation (optional) 1-5/8 8 outside return 8 exhaust supply 23-7/8 15 8 36-1/4 4 10-1/2 14 40-3/4 Bolt Pattern (1/2 Dia) 24-1/8 41-3/4 32-1/8 Model, options and product number WPDB07B-A WPDB07B-B Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 18

6 GENERAL INFORMATION a Technical sheet for Model WPDB07H WPDB07H The WPDB07H is a heat recovery ventilator of 700 CFM. This heat recovery ventilator is the ideal powerful unit for spacious homes, businesses, daycare centers, clinics, bars, restaurants, etc. The WPDB07H is the ultimate solution to prevent excess humidity and improve quality. Optional version with recirculation system is available. High performance flow Silent Highly cost effective and cost efficient Norms and certifications Conformity to Norm : 1. C22.2 no113 2. UL 507 Certified Casing Material : Pre-painted steel 22GA Insulation : 1 foil faced fiberglass Drain connection : Ø3/8 or Ø ½ Duct diameter: 8 in x 14 in Height : 23 7/8 in Width : 36 1/4 in Depth : 32 1/4 in Weight : 150 lbs Blowers Number : 2 Type: backward curved centrifugal fans Mount Suspended by chains with anti-vibration springs or on a shelf Electrical Specifications Tension : 120 VAC 230 VAC Frequency : 60 Hz Amperage : 5.5 A 2.9 A Power : 660 Watt Electrical wiring : Extension cord (120VAC; WPDB07H-A) Field wired (230VAC; WPDB07H-B) Control Low voltage dry contact (24 VAC 20Va) for : Occupancy control (start / stop) Speed selection Exchange / recirculation (optional) 24VAC 10VA output for : Supply damper Exhaust damper Compatible with : Liquid crystal display electronic humidistat (no 611227) Mode Control (exchange or recirculation) (no 611230) Humidity Control (no 611224) Speed Control (intermittent, high or low speed) (no 611229) Timer (no 611228) Defrost Cycles Controlled by a temperature sensor By exhaust only By recirculation (optional) DEFROST CYCLE TEMPERATURE Outside temperature Standard Extended Celsius Fahrenheit min def/vent min def/vent t > -5 t > 23 n.a. n.a. -5 > t > -25 23 > t > -13 7/25 10/20-25 > t -13 > t 10/22 10/15 Filters Number : 4 Type (standard) : Washable, aluminum (no 683901) Options and restriction Airflow (CFM) MERV 8 Charcoal High-Efficiency 300 0,03 0,03 0,03 500 0,08 0,08 0,08 700 0,15 0,15 0,15 Dimensions : 13 3/4 in X 15 in X 7/8 in Recovery Core Material : Aluminium Performance certified : Quantity : 2 Dimensions : 12 in X 12 in X 15 in Step : 2.5mm Warranty Appliance : limited 2 years Core Assembly : limited 3 years Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 19

6 GENERAL INFORMATION WPDB07H VENTILLATION PERFORMANCE WPDB07H WPDB07H (%) Efficiency (inh20) Pressure DIMENSIONS Recirculation (optional) 1-5/8 8 outside return 8 exhaust supply 23-7/8 15 8 36-1/4 4 10-1/2 14 40-3/4 Bolt Pattern (1/2 Dia) 24-1/8 41-3/4 32-1/8 Model, options and product number WPDB07H-A WPDB07H-B Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 20

6 GENERAL INFORMATION a Technical sheet for Model WPDB11B Model WPDB11B The WPDB11B is a heat recovery ventilator of 700 CFM. This heat recovery ventilator is the ideal powerful unit for spacious homes, businesses, daycare centers, clinics, bars, restaurants, etc. The WPDB11B is the ultimate solution to prevent excess humidity and improve quality. Optional version with recirculation system is available. High performance flow Silent Highly cost effective and cost efficient Norms and certifications Conformity to Norm : 1. C22.2 no113 2. UL 507 Certified Casing Material : Pre-painted steel 22GA Insulation : 1 foil faced fiberglass Drain connection : Ø3/8 or Ø ½ Duct diameter: 8 in x 14 in Height : 23 7/8 in Width : 36 1/4 in Depth : 32 1/4 in Weight : 150 lbs Blowers Number : 2 Type: backward curved centrifugal fans Mount Suspended by chains with anti-vibration springs or on a shelf Electrical Specifications Tension : 120 VAC 230 VAC Frequency : 60 Hz Amperage : 5.5 A 2.9 A Power : 660 Watt Electrical wiring : Extension cord (120VAC; WPDB11B-A) Field wired (230VAC; WPDB11B-B) Control Low voltage dry contact (24 VAC 20Va) for : Occupancy control (start / stop) Speed selection Exchange / recirculation (optional) 24VAC 10VA output for : Supply damper Exhaust damper Compatible with : Liquid crystal display electronic humidistat (no 611227) Mode Control (exchange or recirculation) (no 611230) Humidity Control (no 611224) Speed Control (intermittent, high or low speed) (no 611229) Timer (no 611228) Defrost Cycles Controlled by a temperature sensor By exhaust only By recirculation (optional) DEFROST CYCLE TEMPERATURE Outside temperature Standard Extended Celsius Fahrenheit min def/vent min def/vent t > -5 t > 23 n.a. n.a. -5 > t > -25 23 > t > -13 7/25 10/20-25 > t -13 > t 10/22 10/15 Filters Number : 4 Type (standard) : Washable, aluminum (no 683901) Options and restriction Airflow (CFM) MERV 8 Charcoal High-Efficiency 300 0,03 0,03 0,03 500 0,08 0,08 0,08 700 0,15 0,15 0,15 Dimensions : 13 3/4 in X 15 in X 7/8 in Recovery Core Material : Aluminium Performance certified : Quantity : 2 Dimensions : 12 in X 12 in X 15 in Step : 2.5mm Warranty Appliance : limited 2 years Core Assembly : limited 15 years Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 21

6 GENERAL INFORMATION WPDB11B VENTILLATION PERFORMANCE WPDB11B WPDB11B (%) Efficiency (inh20) Pressure DIMENSIONS Recirculation (optional) 1-5/8 8 outside return 8 exhaust supply 23-7/8 15 8 36-1/4 4 13-5/8 20 40-3/4 Bolt Pattern (1/2 Dia) 37-1/2 41-3/4 47-1/4 Model, options and product number WPDB07H-A WPDB07H-B Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 22

6 GENERAL INFORMATION a Technical sheet for WPDB11H WPDB11H The WPDB11H is a heat recovery ventilator of 700 CFM. This heat recovery ventilator is the ideal powerful unit for spacious homes, businesses, daycare centers, clinics, bars, restaurants, etc. The WPDB11H is the ultimate solution to prevent excess humidity and improve quality. Optional version with recirculation system is available. High performance flow Silent Highly cost effective and cost efficient Norms and certifications Conformity to Norm : 1. C22.2 no113 2. UL 507 Certified Casing Material : Pre-painted steel 22GA Insulation : 1 foil faced fiberglass Drain connection : Ø3/8 or Ø ½ Duct diameter: 8 in x 14 in Height : 23 7/8 in Width : 36 1/4 in Depth : 32 1/4 in Weight : 150 lbs Blowers Number : 2 Type: backward curved centrifugal fans Mount Suspended by chains with anti-vibration springs or on a shelf Electrical Specifications Tension : 120 VAC 230 VAC Frequency : 60 Hz Amperage : 5.5 A 2.9 A Power : 660 Watt Electrical wiring : Extension cord (120VAC; WPDB11H-A) Field wired (230VAC; WPDB11H-B) Control Low voltage dry contact (24 VAC 20Va) for : Occupancy control (start / stop) Speed selection Exchange / recirculation (optional) 24VAC 10VA output for : Supply damper Exhaust damper Compatible with : Liquid crystal display electronic humidistat (no 611227) Mode Control (exchange or recirculation) (no 611230) Humidity Control (no 611224) Speed Control (intermittent, high or low speed) (no 611229) Timer (no 611228) Defrost Cycles Controlled by a temperature sensor By exhaust only By recirculation (optional) DEFROST CYCLE TEMPERATURE Outside temperature Standard Extended Celsius Fahrenheit min def/vent min def/vent t > -5 t > 23 n.a. n.a. -5 > t > -25 23 > t > -13 7/25 10/20-25 > t -13 > t 10/22 10/15 Filters Number : 4 Type (standard) : Washable, aluminum (no 683901) Options and restriction Airflow (CFM) MERV 8 Charcoal High-Efficiency 300 0,03 0,03 0,03 500 0,08 0,08 0,08 700 0,15 0,15 0,15 Dimensions : 13 3/4 in X 15 in X 7/8 in Recovery Core Material : Aluminium Performance certified : Quantity : 2 Dimensions : 12 in X 12 in X 15 in Step : 2.5mm Warranty Appliance : limited 2 years Core Assembly : limited 3 years Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 23

6 GENERAL INFORMATION WPDB11H VENTILLATION PERFORMANCE WPDB11H WPDB11H (%) Efficiency (inh20) Pressure DIMENSIONS Recirculation (optional) 1-5/8 8 outside return 8 exhaust supply 23-7/8 15 8 36-1/4 4 13-5/8 20 40-3/4 Bolt Pattern (1/2 Dia) 37-1/2 41-3/4 47-1/4 Model, options and product number WPDB11H-A WPDB11H-B Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 24

6 GENERAL INFORMATION e Warranty We guarantee this product and all its components to be free from defects in material and factory workmanship for a period of 2 years. This warranty plan does not cover any defect resulting from improper installation, misuse, acts of God and/or other similar causes beyond the control of the manufacturer. Carnes shall not be liable for implied or expressed warranty for damages or indemnity. Neither shall Carnes be responsible for any injury or harm caused directly or indirectly by our ventilation units. How to claim Any claim concerning a defective unit or any of its components should be submitted to Carnes who will replace it by an identical or a similar part or will rep it according to the advice of the company s representa - tive. The cost for removal and installation of the defective parts is not covered by this actual warranty. We recommend talking with one of our technicians before removing any unit. He can probably indicate another way to solve the problem. Obtain an authorization number from our customer service department before sending a unit for service. Please forward the defective part prepaid to the address below. It will be returned to you prepaid. Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 25

6 GENERAL INFORMATION f Additional information For more details on the installation or the operation of your unit contact your dealer or the staff of our residential division. We will be glad to help you. Carnes Company 448 S. Main Street P.O. Box 930040 Verona, WI 53593-0040 Phone: (608) 845-6411 Fax: (608) 845-6504 g Product information Date of purchase Serial number Store (dealer) *Keep your sales slip as proof of purchase. Maintenance sheet Date Installation instruction & owner s guide - Model WPDB07B - WPDB11B / WPDB07H - WPDB11H 26