Breathe Easy With. Out. Out 54 FINE HOMEBUILDING. COPYRIGHT 2014 by The Taunton Press, Inc. Copying and distribution of this article is not permitted.

Similar documents
Put the V back in HVAC

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

Tech to Tech May 07 HRV s & ERV s

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Indoor Air Quality Product Brochure.

Houses Need to Breathe... Right?

WHOLE-HOUSE VENTILATION SYSTEMS

BEST PRACTICE RECOMMENDATIONS

Indoor Air Quality Product Brochure.

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Building Science Basics

Ventilation Solutions IAQ Canada

Energy Recovery Ventilation

An Introduction to Energy Efficient and Effective Whole-House Ventilation

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

SAFETY AND INSTALLATION MANUAL MODEL 8100

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Residential Heat & Energy Recovery

Limited Lifetime core warranty. 5-year warranty on balance of unit.

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

IAQ VENTILATION SOLUTIONS

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

IAQ VENTILATION SOLUTIONS

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

The best way to enhance indoor air quality

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Ventilation Solutions IAQ Canada

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

Heat & Energy RECOVERY VENTILATORS

TR Series - The Ultimate ERV

Heat Recovery Ventilation

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

Tuning up ventilation systems

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

LEED for Homes Points

Ventilation for New Low-Rise Residential Buildings July 20, 2015

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Clearing the Air: Ventilation. RESNET Building Performance Conference San Diego, CA February 17 th, 2015

Outside Air Requirements... SOLVED!

Ventilation, Makeup and Combustion Air Calculations Submittal Form New Dwellings

Ventilation Strategies in Weatherization

Ventilation Techniques. Topic 5 - Audio 53

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

Moisture, Ventilation & Global Weirding NEHERS Webinar Series

Effects of Kitchen Ventilation on Residential Dwellings

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Site address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

The Art of Building Science

Overview and Specifications

Ventilation Unit Zehnder ComfoAir 350

Dwelling Ventilation Strategies, Including ASHRAE 62.2 ASHRAE Ventilation for Acceptable Indoor Air Quality

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Home Performance Science

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Indoor Environmental Quality

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

City of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )

Bill McCullough. Director ERV Products. Dallas, TX

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

HEALTH. Particles. Chemicals

Applying the latest version of the National Ventilation Standard Heyoka Solutions, LLC Paul H. Raymer

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Managing HVAC in High Performance Buildings

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Ventilation and Indoor Air Quality

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

Building Codes, Ventilation Rates, and Certified Performance. Ventilation Track Comfortech 2007 St Louis, MO September 27, 2007

Fresh Air Solutions Whole-Home Ventilation

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Supplement A- Improving Forced Air Heating Systems

Green Building Practice Summary 3/10/2011

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Uniform Dwelling Code 2017 Updates SPS 323

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

Ventilation and the Indoor Environment

HEALTH. Particles. Chemicals

Consumer Features & Benefits of Energy Efficient Products

HVAC for Raters & Inspectors

EARTH ADVANTAGE HVAC REQUIREMENTS

Energy Recovery Ventilation Introduction

The Heating System and Ventilation and Combustion Air

Keeping the Heat In 9 Operating your house

SUNDRY ASPECTS OF HEAT RECOVERY VENTILATION. In my earlier articles I have described the basics of a Heat Recovery Ventilation system:

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

DUCTING FOR HRV SYSTEMS The distribution of airflows

BETTER AIR. BETTER LIFE.

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

Spray Polyurethane Foam and Open-Combustion Appliances

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

IT S ABOUT TIME FOR FRESH AIR.

BPI 1200 and ASHRAE Standards

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

Transcription:

Breathe Balanced Easy With The best solutions provide fresh the whole Out Bad -only ventilation uses a relatively low-volume bathroom fan run either continuously or at intervals on a timer to expel stale the home. Although excellent for their intended use, bath fans aren t ideal as a whole-house ventilation solution. Drawing air through the fan creates a slight negative pressure in the house and pulls air through leaks in the envelope. There is no control over the source of incoming air. It could as easily come from the garage, basement, or utility room as around the jambs of a second-floor window. In Better Supply-only ventilation is the inverse of the exhaust scenario: A fan pulls fresh air into the house; under pressure, air finds its way out of the house through cracks. This is an improvement over the exhaust-only system because pressurizing the house makes the fan less likely to pull the garage and because incoming air can be filtered. Depending on the system, though, it can be inefficient to use the furnace fan to distribute air. In Out Best Balanced ventilation makes the most sense if you intend to control the source of your fresh air. By relying on separate intake and exhaust fans working as a system, the amount of air that you expel from the house is matched by the amount of fresh air supplied by the ventilation equipment. This avoids depressurizing or pressurizing the house; the source of incoming air is planned and controlled, and it s filtered. The fans are small and cheap to operate. Best of all, balanced systems are available with heat exchangers to recover the heating or cooling energy in the outgoing air. 54 FINE HOMEBUILDING Drawings: Christopher Mills

Ventilation house without a severe energy penalty BY SEAN GROOM Houses need fresh air. Without ventilation, the quality of indoor air can rapidly become worse than that of the air; that holds true even in urban areas. Common contaminants include gases, odors, and moisture, and these can stem from utility rooms, garages, basements, bathrooms, and kitchens. Until recently, fresh air entered a typical house through various openings, whether intentional (a fan or open window) or unintentional (holes and leaks around windows, rim joists, door jambs, and sheathing penetrations). Over the last few decades, however, houses have become tighter, and the unintentional flow of air through the building envelope has been reduced. Once a house reaches about five air changes per hour (ACH), it s important to start thinking about using mechanical ventilation to ensure indoor-air quality. In regions with moderate to significant heating and/or cooling loads, HRVs and ERVs are the most efficient means of mechanical ventilation. Depending on the efficiency of the heat exchanger, it can transfer anywhere from 50% to 91% of the conditioned air s heat and energy to the supply air. Homeowner satisfaction with a recovery ventilator will depend on the answers to three questions: Does it keep the air temperature comfortable? Is it cheap to operate? Is it excessively noisy? Does it keep the air temperature comfortable? Comfort speaks to a unit s thermal efficiency. Thermal efficiency is the recovery ventilator s ability to transfer the temperature of the outgoing the incoming air. When a unit transfers a high percentage of the heat or cold to the incoming air, the fresh air can be diffused directly into the living space without Retrofit ready. Lunos e² devices are small, ductless HRVs with ceramic heat exchangers. Working in pairs ($1200), one pulls air in while the other pushes air out, and airflow direction changes every 70 seconds. Installed through a hole in the wall, they use little electricity, are quiet, and provide between 10 cfm and 25 cfm at about 90% efficiency. How much ventilation is enough? ERVs and HRVs must be able to run at two ventilation rates: the background ventilation rate required to ensure the right number of air changes per hour for the house, and a second, higher rate when the bathrooms and kitchen need a boost. The boost rate is typically 50% higher than the background rate. The background ventilation rate is determined by the home s exhaust requirement. Depending on whom you ask, this can be determined by the number of bathrooms, the number of occupants, the infiltration rate of the house, and the size of the house either in isolation or in combination. Recovery-ventilator manufacturers offer guidance for sizing a unit, but the ultimate arbiter is your local building code. Many codes have adopted the American Society of Heating, Refrigeration, and Air Conditioning Engineers standard, referred to as ASHRAE 62.2. This standard requires 7.5 cfm per person (calculated by number of bedrooms, with the master bedroom counting twice) plus 3 cfm per 100 sq. ft. Prior to the 2013 revision, this calculation used only 1 cfm per 100 sq. ft., and the increased ventilation rate has met with strong resistance from building scientists and ventilation engineers who argue that for new, tight houses, the new standard imposes a stiff energy penalty by overventilating. At least one competing standard has emerged from Building Science Corporation, but it s too early to know what standard the building codes will adopt. www.finehomebuilding.com APRIL/MAY 2014 55

BALANCED VENTILATION SHOULD BE RECOVERY VENTILATION There are three types of balanced mechanical ventilation. Each relies on one or more fans to bring fresh air into the house and to exhaust stale air out of the house. These are called balanced systems because the volume of air moved in each direction should be the same. Because differences in duct lengths and the number of elbows affect airflow, these systems need to be tested and tuned to achieve balance. This process, called commissioning, should be part of any installation. Filter Air exchanger By pulling outdoor air into the house at the same rate it expels indoor air, an air exchanger provides balanced ventilation at a relatively low rate, say 60 cfm. Your fresh air won t be quite as fresh as with a recovery ventilator, your stale air won t be completely removed, and the mixing of airstreams is an inefficient way of conditioning supply air. The appliance itself, however, is far less expensive than an HRV or ERV. Filters Improved indoors Stale air from Heat exchanger Stale air from HRV A heat-recovery ventilator is perfectly suited for a heating climate. The idea behind it is simple: Outgoing stale air and incoming fresh air pass through a heat exchanger so that the warm air gives up its heat to the cool airstream. In winter, the outgoing warm air heats the incoming cold air; in summer, the incoming warm air gives up its heat to the outgoing cold air. The two airstreams are kept separate to prevent contaminants in the outgoing tainting the incoming fresh air. Efficiency is a function of how long the air spends in the heat exchanger. There are two heatexchanger designs: crossflow and counterflow. The greater surface area of counterflow designs makes them more efficient, and there are three design types within this category: vertical flat panel, horizontal flat panel, and cellular. Vertical-flat-panel models are the least efficient (50% to 70%), followed by horizontal-flat-panel models (70% to 80%) and cellular heat exchangers (more than 80%). Condensate drain ERV An ERV is ideally suited for a cooling climate. Although it s commonly referred to as an energy-recovery ventilator, ERV actually stands for enthalpy-recovery ventilator. Put simply, an ERV is a moisture- and heat-recovery ventilator. The only difference between an HRV and ERV is a vapor-permeable membrane between the exhaust and intake sides of the heatexchange chamber. Instead of the aluminum or polypropylene that you d find in an HRV, the material between the outgoing and incoming chambers in an ERV is a fabric akin to Gore-Tex. Vapor can pass through the material, but air, gases, odors, and bulk water cannot. Because ERV cores don t have as much surface area as HRVs, they are not as efficient at heat removal. The typical efficiency penalty is about 10%. Heat exchanger Filters Stale 56 FINE HOMEBUILDING

creating cold drafts in the winter and warm eddies of air in the summer. To compare the effects of efficiency on indoor-air temperature, let s say the indoor temperature is 70 F and the outdoor temperature is 30 F. The makeup air an HRV that s 75% efficient distributes through the house is 60 F a far cry from the 30 F air pulled in by an air exchanger, but cool enough to be uncomfortable in a 70 F environment. A 90%-efficient HRV will raise the temperature of the makeup a more comfortable 66 F. The Home Ventilation Institute (HVI), an independent agency, tests and reports the performance of HRVs and ERVs. You can compare the thermal efficiency of different units on its website (hvi.org), including both sensible recovery efficiency and apparent sensible effectiveness (see sidebar below). It s worth checking this database instead of relying on a manufacturer s advertising. Is it cheap to operate? A recovery ventilator should be airtight and well insulated, and it should have an ultra-efficient motor. The degree to which it diverges from this ideal determines overall efficiency and operating cost. Recovery ventilators run continuously, so motor efficiency is critical. The most efficient machines use electronically commutated motors (ECMs). The best measure of over- all efficiency is expressed as cfm/w, or how many watts it takes to exchange a cubic foot of air per minute. Plenty of recovery ventilators have a cfm/w ratio under 1.0, but aim for a value of 1.5 or better. Is it excessively noisy? A well-insulated house reduces sound transmission from the ; as a side effect, noises from mechanical systems the house become much more noticeable. It s important to install the recovery ventilator in a utility room away from the bedrooms. Unfortunately, no independent organization tests these ventilation products for operating noise. The two recovery-ventilator brands I know that publicize noise levels are Lunos and Zehnder. Ratings are in decibels and not sones, which is the measure used for bath fans. Zehnder is the only system I m aware of that incorporates a duct silencer. In talking with architects and building scientists who have specified equipment for projects, I ve heard a few brands consistently mentioned as quiet: tech, Venmar, and Zehnder. One feature consumers can look for are ECMs; in addition to being efficient, they are quieter than alternating-current (AC) motors. Do you want an ERV or HRV? One thing that often confounds people looking at recovery ventilators for the first time Integration for high performance. Most manufacturers leave it up to the installer to fabricate or source ductwork. Switzerland-based Zehnder s system includes proprietary 3-in.-o.d. flexible duct (nearly smooth on the to improve airflow), which snaps easily into register boxes. The supply and return manifolds absorb sound from the fans. With heat-recovery efficiencies as high as 91%, its units top the field. ONE MACHINE BUT TWO EFFICIENCY SCORES Recovery ventilators report thermal efficiency in two categories: sensible recovery efficiency (SRE) and apparent sensible effectiveness (ASE). SRE is the true measure of the heat exchanger s efficiency; it measures only the amount of heat transferred across the plates of the heat exchanger, not including any variables. ASE includes heat from sources other than the exchanger itself. Waste heat generated from the unit s motors, air leakage between the exhaust- and fresh-air streams, and heat from other appliances in the room can skew the apparent efficiency of the ventilator by more than 10%. ASE includes heat from the unit and ambient heat from external sources SRE measures only the heat exchanger www.finehomebuilding.com APRIL/MAY 2014 57

Stale air is stripped of its heat and then exhausted. air enters the house. Conditioned fresh air is supplied to bedrooms. is whether they should choose an HRV or an ERV. The essential difference between the two is that an ERV transfers moisture, as well as heat, between the two airstreams. If you live in a region with a very consistent climate, then the answer is simple: Choose an HRV for cold climates and an ERV for hot, humid climates. The problem is that a lot of North America falls into the mixed-climate category. To choose between an ERV and HRV in a mixed climate, you ve got to look at the length of the cooling season, the amount of outdoor humidity, and the conditions the house. First, consider that the flow of moisture in an ERV is from the warm, moist airstream to the cold, dry airstream. This means that in the summer, humidity is transferred to the colder stream, which is exhausting the house. In the winter, though, the colder stream is incoming, so the ERV is raising humidity levels in the house. That s why home size and the number of occupants can make an ERV the wrong choice in some situations. In a small, sufficiently air-sealed house with many occupants, the relative humidity in Stale air is picked up from the bathrooms and the kitchen. winter may be fairly high, and capturing and returning humidity to the house with an ERV could raise relative humidity to unhealthy levels. On the other hand, a larger house with few occupants could be made more comfortable by returning the relatively low moisture content to the house with an ERV. In these cases, an ERV might raise relative humidity 8% to 10% above the 35% to 45% relative humidity you d get with an HRV. In regions where the cooling season is dominant and there s outdoor humidity, an ERV is the clear choice. When an ERV reduces the humidity of the incoming air, it s making you more comfortable; it s also easing the burden on your air-conditioning system by reducing the amount of moisture it has to remove from the air. In colder regions, an HRV makes the most sense. There might be a slight comfort bump from an ERV s raising of the relative humidity in winter, but it would be outweighed by the greater thermal efficiency of an HRV. Sean Groom is a contributing editor. Photos courtesy of the manufacturers. Forget HVAC. You want HAC & V To get the most out of a ventilation system, decouple it from the heating and cooling systems. The potential problem with connecting your recovery ventilator to a forced-air heating and cooling system is that the furnace becomes the distribution fan for ventilation. A furnace fan is larger and less efficient than a recovery ventilator. Without a Cycler or similar device, this overventilates the home and does so at a higher price. The other problem with using HVAC ducts for ventilation is that it short-circuits the airexchange process. Properly installed ventilation creates airflow through the house by estab lishing a cascade of air from supply vents to exhaust vents (drawing left). Supply diffusers are placed in bedrooms or walk-in closets, while exhaust vents are placed in the bathrooms and the kitchen. The idea is that fresh air is delivered to the sleeping areas, drawn through the hallways into the common living spaces, and then vented out of the house from the bathrooms and the kitchen. This cascade design flushes stale air out of the house at relatively low cfm, reducing both energy use and noise. Adding airsupply diffusers in general living areas or having vents and supplies in the same room will short-circuit air movement, causing fresh flow directly from supply to exhaust. Bath vents should have boost switches, which increase the fan rate when moisture accu mulates, either by humidistat control or a manually activated timer switch. In the kitchen, a recovery ventilator intake cannot take the place of a range hood. Separate ventilation is needed for airborne oils. To keep ventilation rates balanced, system designers often recommend an induction cooktop because there s no combustion. A recirculating hood can then be used to trap oil and to push air back into the kitchen so the ERV or HRV can exhaust it. 58 FINE HOMEBUILDING