Property Condition Report

Similar documents
Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Home Inspection Report

Home Inspection Report

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

Home Inspection Report

Home Inspection Report

American Property Inspectors of Northwest Florida, Inc.

Home Inspection Report

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Axiom Property Inspections

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Inside Out Home Inspections

fieldwork report contains the Functional

Jeff Brown Inspections

Troy's Home Inspection Services LLC

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Inspection Report 123 My Street Midland, GA

Cascade Inspection Services, LLC

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Hearth and Homes Inspections, llc

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

Inspector FX Field Forms

Canadian Property Inspections

Hope Home Inspections LLC rd Ln E Sarasota, FL

Peconic Home Inspections, LLC Inspection Report. 123 Lane Suffolk, New York 11900

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Property Inspection Report

Extra Mile Inspection, Inc.

McKinney Inspection Company

SPS Home Inspections, LLC

Home Inspection Report

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

Watson Home Inspection Services, LLC.

BISHOP HOME INSPECTIONS, LLC. Phone (269) / Fax (269) / Website: bishophomeinspection.

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

All In One Home Inspections

MHI Services Inc. Property Inspection Report

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

Bayshore House Inspections LLC

Steve Ramsey Home Inspections

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

RW West Consultants. Property Inspection Report

Excellent Home Inspection Services, LLC

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

Patriot Home Inspections

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Inspection Report. Inspection Date: 5/1/2010. Single Family Sample Report. Property Address: Address. City State Zip. All In One Home Inspection LLC

I. STRUCTURAL SYSTEMS

Inspector Gadget Homes

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

Residential Construction and Remodeling Estimates. compliments of. pillartopost.com

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Canadian Property Inspections

Space Coast Home Inspections LLC

SUMMARY 1234 Main St.Edmonton AB T5T3E9 Buyer Name 07/05/2018 9:00AM

Maintence/Renewal Report

Tennessee Valley Property Inspections

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

FAIRA TRANSPARENCY REPORTS NE 178th St, Lake Forest Park, WA May 2 nd, 2017

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

FAIRA TRANSPARENCY REPORTS

Inspection Report. Property Address: XXXX Sondrio Dr Las Vegas NV Skye Canyon Home Inspection Services

Residential * Commercial * Mobile Homes * New Construction

HOME INSPECTION REPORT

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

Coast Home Inspection

FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

This Report Was Prepared For: Property Address Inspected:

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

ITEMS NEEDING ACTION

Home Inspection Report

FAIRA TRANSPARENCY REPORTS

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

Amendment to the Inspection Report

26632 Timberlane Dr SE, Covington, WA 98042

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

FAIRA TRANSPARENCY REPORTS. July 6, 2016

1152 Vinetta - Des Peres The Wakefield Model $634,900

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

RW West Consultants, Inc. Property Inspection Report Inspector: Clifton Moody (Skip), RW West Consultants, Inc. Cover Page

FAIRA TRANSPARENCY REPORTS th Ave N, Edmonds, WA January 19 th, 2018

FAIRA TRANSPARENCY REPORTS th Ave NE, Arlington, WA 98223

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

Inspection Report. Eagle Eye Home Inspectors. John R. Dixon 24GI McKinley Court Princeton, NJ

Transcription:

10 Public Square Willoughby, Ohio 44094 Property Condition Report 1234 Main St. Mentor, OH 44060

Page 1 of 19 Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior Surface and Components 3 Roof 4 Garage/Carport 4 Electrical 5 Structure 5 Attic 6 Basement 7 Air Conditioning 7 Heating System 8 Plumbing 8 Bathroom 9 Kitchen 10 Bedroom 11 Living Space 12 Laundry Room/Area 13 Summary 14

Page 2 of 19 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection. A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function. Property Address 1234 Main St. City Mentor State Ohio Zip 44060 Client Name John Smith Inspector Name Eric Miller Company Name Camelot Home Inspections, Inc. Address 10 Public Square City Willoughby State Ohio Zip 44094 Phone 440-602-9797 Fax 440-602-9933 Inspection Date 01/11/2012 Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable Building Type Single family Garage Attached General Information Property Information Client Information Inspection Company Conditions

Page 3 of 19 Lots and Grounds Wood siding should be a minimum of 6" above ground. Detection of the presence of concealed moisture, mold or wood decay present behind exterior finishes is beyond the scope of this inspection. Promote positive (+) drainage away from foundation and extend runoff from roofing and downspouts a minimum 10 ft from foundation. Pictures are provided for illustration purposes only and are not to be relied on or regarded as part of the Inspection Walks: Concrete - Cracked Patio: Concrete - Settlement observed Vegetation: Shrubs/trees - Prune vegetation away from structure Grading: Moderate slope - Grades toward rear of structure Driveway: Concrete - Cracks in surface Exterior Surface and Components House and garage Exterior Surface Type: Aluminum siding and brick Fascia: Aluminum - Missing section Soffits: Vinyl Entry Doors: Wood Patio Door: Vinyl sliding Windows: Vinyl casement Window Screens: Vinyl mesh - Missing/some stored in basement Exterior Lighting: Surface mount Exterior Electric Outlets: 110 VAC - Recommend GFCI's as needed Gas Meter: Exterior surface mount at side of home - Rust present:paint as needed Main Gas Valve: Located at gas meter

Page 4 of 19 Roof Chimney flue inspection is limited due to height. The inspection covers only the visible portion of the flue. Main Roof Surface Method of Inspection: On roof Material: Asphalt/Fiberglass shingle Type: Gables Approx Age: 10 to 15 Years Valleys: Asphalt/Fiberglass shingle Plumbing Vents: PVC Gutters: Aluminum Downspouts: Aluminum Central Chimney Chimney: Metal - Rust present Flue/Flue Cap: Metal Chimney Flashing: Metal Garage/Carport Attached Garage Type of Structure: Car Spaces: 2 Garage Doors: Wood Door Operation: Mechanized Service Doors: Metal - Add closing mechanism to entry door, Missing handle and lock hardwae Ceiling: Drywall - Loose or peeling textured ceiling Floor/Foundation: Block foundation/poured floor - Settlement cracks, Floor settled approximately 2" Hose Bibs: Rotary Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Extension cord in use/light not permanent

Page 5 of 19 Garage/Carport (Continued) Windows: Wood double hung - Boarded over, Broken glass Electrical This report reflects general conditions noted during the time of inspection. Electrical systems because of their nature and complexity are subject to deterioration or breakdown over time that cannot be predicted. Recommended grounded and GFCI protected outlets be installed at all Exterior, Kitchen, Wet Bar, Garage and Unfinished Basement outlet locations. Service Size Amps: 100 Volts: 220 VAC Service: Aluminum 120 VAC Branch Circuits: Copper 240 VAC Branch Circuits: Copper Conductor Type: Romex Ground: Plumbing ground - Recommend grounding to rod Basement main Electric Panel Max Capacity: 100 Amps Main Breaker Size: 100 Amps Basement Electric Panel Breakers: CU/AL - Double tap wiring on #1,5,7,12,21:fire hazard, Contact a qualified electrician for further evaluation:breaker connections appear to be rated for 2 wires but label rating reads 1 Is the panel bonded? Yes No Structure Structure Type: Wood frame Foundation: Block - Cracked with displacement:approximately 1/2", A qualified contractor is recommended to evaluate and estimate repairs Beams: Steel I-Beam Bearing Walls: Block/frame

Page 6 of 19 Structure (Continued) Joists/Trusses: 2x10 - Mold visible mostly in laundry area - potential health concern Piers/Posts: Steel posts Floor/Slab: Poured slab - Cracked Stairs/Handrails: Wood stairs with wood handrails Subfloor: Plywood - Mold visable:potential health concern Attic Garage Attic Method of Inspection: From the attic access Unable to Inspect: 30% - Insulation Roof Framing: 2x4 Truss Sheathing: Plywood Ventilation: Gable and soffit vents Insulation: Batts Insulation Depth: 3-4" Attic Fan: Direct drive - Too cold Wiring/Lighting: 110 VAC lighting circuit - Inoperative Moisture Penetration: None visable Main Attic Method of Inspection: From the attic access Unable to Inspect: 40% - Insulation, Not floored Roof Framing: 2x4 Truss Sheathing: Plywood - Mold present:potential health concern Ventilation: Gable, ridge and soffit vents Insulation: Batts Insulation Depth: 9" Attic Fan: Direct drive - Too cold Wiring/Lighting: 110 VAC lighting circuit - Loose wiring Moisture Penetration: Yes - Mold present:potential health concern Bathroom Fan Venting: Electric fan - Bathroom improperly vents into attic and may cause moisture damage

Page 7 of 19 Basement Inspection does not cover any damage concealed by rugs, carpeting, wall paneling, furniture or fixtures. Typical wall/ceiling minor cracks/touch ups are considered normal. Main Basement Unable to Inspect: 30% - Finished space - Unfinished Doors: Hollow wood - The door is sticking Windows: Wood Electrical: 110 VAC outlets and lighting circuits - Loose wiring,outlet lying on floor, Incomplete, Missing outlet(s),switches etc. HVAC Source: Air exchange ventilation/baseboard Ventilation: Windows Insulation: None - Recommend installing insulation Moisture Location: Walls - Water stains present mostly in n.e. corner and front south wall adjacent garage:active, Mold present on floor joists:potential health concern Bsmt Stairs/Railings: Wood stairs with wood handrails Air Conditioning This report reflects general conditions noted during the time of the inspection. HVAC systems because of their nature and complexity are subject to deterioration or breakdown over time that cannot be predicted. Annual cleaning and servicing recommended for best performance and life expectancy. Main AC System A/C System Operation: Unknown - Too cold to operate, The unit is nearing the end of the manufactures stated design life Exterior Unit: Condenser - Unit not level Area Served: Approximate Age: 16 Years Fuel Type: 220 VAC Temperature Differential: Type: Central A/C Capacity: 3 ton Refrigerant Lines: Serviceable condition - Torn insulation

Page 8 of 19 Electrical Disconnect: Fused switch Air Conditioning (Continued) Heating System This report reflects general conditions noted during the time of the inspection. HVAC systems because of their nature and complexity are subject to deterioration or breakdown over time that cannot be predicted. Annual cleaning and servicing recommended for best performance and life expectancy. Basement Heating System Heating System Operation: Functional Type: Forced air Capacity: 100,000 BTUHR Area Served: Approximate Age: 17 Years Fuel Type: Natural gas Heat Exchanger: 4 Burner - Enclosed: recommend inspection by a qualified heating specialist Blower Fan/Filter: Direct drive with disposable filter - Filter installed in reverse Distribution: Metal duct Draft Control: Power vent Flue Pipe: Single wall - Negative slope at elbow Thermostats: Individual Plumbing This report reflects general conditions noted during the time of the inspection. Plumbing systems because of their nature and complexity are subject to deterioration or breakdown over time that cannot be predicted. Water heater tested for functional operation at time of inspection only. Approximately 200 gallons of water is pushed through sewer drain lines to verify functional drainage of public sewer or septic systems. Service Line: Copper

Page 9 of 19 Plumbing (Continued) Main Water Shutoff: Basement - Active leak(s) Water Lines: Copper Drain Pipes: PVC Service Caps: Not visible Vent Pipes: PVC Gas Service Lines: Cast iron Basement Water Heater Water Heater Operation: Unknown - Gas shut-off, Water heater has exceeded design life Type: Natural gas Capacity: 40 gallons Approximate Age: 16 Years Area Served: Flue Pipe: Single wall - Flat slope TPRV and Drain Tube: Brass/copper Bathroom Family room Bathroom Ceiling: Drywall Floor: Ceramic tile Doors: Hollow wood Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed Counter/Cabinet: Marble and wood Sink/Basin: Molded single bowl Faucets/Traps: Fixtures with a metal trap - Past leaks/rust Toilets: Porcelain - Flush valve leaks HVAC Source: Air exchange ventilation Ventilation: Electric ventilation fan - Loose cover Hall Bathroom Ceiling: Drywall Floor: Ceramic tile Doors: Hollow wood Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed Counter/Cabinet: Marble and wood

Page 10 of 19 Bathroom (Continued) Sink/Basin: Molded single bowl Faucets/Traps: Fixtures with a metal trap - Past leaks, Rust Tub/Surround: Fiberglass Toilets: Porcelain HVAC Source: Air exchange ventilation Ventilation: Electric ventilation fan with heater Master Bathroom Ceiling: Drywall - Loose or peeling paint Floor: Tile Doors: Hollow wood Windows: Vinyl casement Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed Counter/Cabinet: Marble and wood Sink/Basin: Molded single bowl Faucets/Traps: Fixtures with a metal trap - Past leaks, Rust Shower/Surround: Fiberglass Toilets: Porcelain - Flush valve fills very slowly, The tank is loose HVAC Source: Air exchange ventilation Ventilation: Electric ventilation fan with heater Kitchen 1st Floor Kitchen Cooking Appliances: Natural gas Ventilator: Vented through filter Disposal: In-Sinkerator Dishwasher: Built-in Trash Compactor: Functional - Noisy Refrigerator: Side by side - Ice maker/water line leaks Sink: Molded dual bowl Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Missing outlet cover, Encase romex as needed Plumbing/Fixtures: Fixtures with a PVC trap Counter Tops: Laminate

Page 11 of 19 Kitchen (Continued) Cabinets: Wood Ceiling: Drywall Floor: Ceramic tile Doors: Wood Windows: Vinyl casement/wood double hung HVAC Source: Air exchange ventilation Bedroom Side center Bedroom Closet: Single Ceiling: Drywall Floor: Carpet - Stains Doors: Wood Windows: Wood double hung Electrical: Outlets, lighting and ceiling fan HVAC Source: Air exchange ventilation Front south Bedroom Closet: Single Ceiling: Drywall Floor: Carpet Doors: Wood Windows: Wood double hung Electrical: Outlets, lighting and ceiling fan HVAC Source: Air exchange ventilation Front north Bedroom Closet: Single Ceiling: Drywall Floor: Carpet - Stains Doors: Hollow wood Windows: Wood double hung

Page 12 of 19 Bedroom (Continued) Electrical: 110 VAC outlets and lighting circuits HVAC Source: Air exchange ventilation - Cover(s) missing Living Space Inspection does not cover any damage concealed by rugs, carpeting, wall paneling, furniture or fixtures. Typical wall/ceiling minor cracks/touch ups are considered normal. Patio enclosure Living Space Windows: Wood casement - Screens loose/torn Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed Family Room Living Space Closet: Single Ceiling: Drywall Floor: Carpet - Stains Doors: Vinyl slider Windows: Wood double hung Electrical: Outlets, lighting and ceiling fan - Missing switch cover HVAC Source: Air exchange ventilation Dining/family Room Living Space Ceiling: Drywall - Cracks present Floor: Laminate Windows: Vinyl casement - Missing window crank knobs Electrical: 110 VAC outlets and lighting circuits HVAC Source: Air exchange ventilation Foyer/hallway Living Space Closet: Several - Door sticks Ceiling: Drywall - Water stains present:inactive at this time Floor: Carpet/ceramic tile Electrical: 110 VAC outlets and lighting circuits HVAC Source: Air exchange ventilation

Page 13 of 19 Laundry Room/Area Basement Laundry Room/Area Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Single receptacle outlets recommended at washer/dryer Laundry Tub: Fiberglass Laundry Tub Drain: Electric pump/pvc - Missing check-valve Washer Hose Bib: Rotary Washer and Dryer Electrical: 110-220 VAC Dryer Vent: Rigid metal Dryer Gas Line: Cast iron - Shut-off Washer Drain: On wall system Floor Drain: Surface drain - Missing cover

Page 14 of 19 Not Inspected Summary IMPORTANT NOTE - PLEASE READ: The Not Inspected Summary page is provided to allow the reader a brief overview of the report. This page is not encompassing. Reading this page alone is not a substitute for reading the report in its entirety. The entire Inspection Report, including the ASHI Standards of Practice limitation and Pre-Inspection Agreement must be carefully read to fully access the findings of the inspection. This list is not intended to determine which items may need to be addressed per the contractual requirements of the sale of the property. Any areas of uncertainty regarding the contract should be clarified by consulting an attorney or real estate agent. It is recommended that any items Not Inspected and the components/systems related to these not inspected items noted in the report be evaluated/inspected and repaired as needed by licensed contractors/professionals PRIOR TO THE CLOSE OF ESCROW. Further evaluation PRIOR to the close of escrow is recommended so a properly licensed professional can evaluate items not inspected. Please call our office for any clarifications or further concerns. Attic 1. Garage Attic Attic Fan: Direct drive - Too cold 2. Main Attic Unable to Inspect: 40% - Insulation, Not floored 3. Main Attic Attic Fan: Direct drive - Too cold Air Conditioning 4. Main AC System A/C System Operation: Unknown - Too cold to operate, The unit is nearing the end of the manufactures stated design life Heating System 5. Basement Heating System Heat Exchanger: 4 Burner - Enclosed: recommend inspection by a qualified heating specialist Plumbing 6. Basement Water Heater Water Heater Operation: Unknown - Gas shut-off, Water heater has exceeded design life Laundry Room/Area 7. Basement Laundry Room/Area Dryer Gas Line: Cast iron - Shut-off

Page 15 of 19 Marginal Summary IMPORTANT NOTE - PLEASE READ: The Marginal and Defective Summary pages are provided to allow the reader a brief overview of the report. This page is not encompassing. Reading this page alone is not a substitute for reading the report in its entirety. The entire Inspection Report, including the ASHI Standards of Practice limitation and Pre-Inspection Agreement must be carefully read to fully access the findings of the inspection. This list is not intended to determine which items may need to be addressed per the contractual requirements of the sale of the property. Any areas of uncertainty regarding the contract should be clarified by consulting an attorney or real estate agent. It is recommended that any deficiencies and the components/systems related to these deficiencies noted in the report be evaluated/inspected and repaired as needed by a licensed contractors/professionals PRIOR TO THE CLOSE OF ESCROW. Further evaluation PRIOR to the close of escrow is recommended so a properly licensed professional can evaluate our concerns further and inspect the remainder of the system or component for additional concerns that may be outside our area of expertise or the scope of our inspection. Please call our office for any clarifications or further concerns. 1. Walks: Concrete - Cracked 2. Patio: Concrete - Settlement observed Lots and Grounds 3. Vegetation: Shrubs/trees - Prune vegetation away from structure 4. Grading: Moderate slope - Grades toward rear of structure 5. Driveway: Concrete - Cracks in surface Exterior Surface and Components 6. Fascia: Aluminum - Missing section 7. Exterior Electric Outlets: 110 VAC - Recommend GFCI's as needed 8. Gas Meter: Exterior surface mount at side of home - Rust present:paint as needed Roof 9. Central Chimney Chimney: Metal - Rust present Garage/Carport 10. Attached Garage Service Doors: Metal - Add closing mechanism to entry door, Missing handle and lock hardwae 11. Attached Garage Ceiling: Drywall - Loose or peeling textured ceiling 12. Attached Garage Floor/Foundation: Block foundation/poured floor - Settlement cracks, Floor settled approximately 2" 13. Attached Garage Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Extension cord in use/light not permanent

Page 16 of 19 Marginal Summary (Continued) 14. Attached Garage Windows: Wood double hung - Boarded over, Broken glass Electrical 15. Ground: Plumbing ground - Recommend grounding to rod Structure 16. Floor/Slab: Poured slab - Cracked Attic 17. Garage Attic Unable to Inspect: 30% - Insulation 18. Garage Attic Wiring/Lighting: 110 VAC lighting circuit - Inoperative 19. Main Attic Wiring/Lighting: 110 VAC lighting circuit - Loose wiring 20. Main Attic Bathroom Fan Venting: Electric fan - Bathroom improperly vents into attic and may cause moisture damage Basement 21. Main Basement - Unfinished 22. Main Basement Doors: Hollow wood - The door is sticking 23. Main Basement Insulation: None - Recommend installing insulation Air Conditioning 24. Main AC System Exterior Unit: Condenser - Unit not level 25. Main AC System Refrigerant Lines: Serviceable condition - Torn insulation Heating System 26. Basement Heating System Blower Fan/Filter: Direct drive with disposable filter - Filter installed in reverse 27. Basement Heating System Flue Pipe: Single wall - Negative slope at elbow Plumbing 28. Service Caps: Not visible 29. Basement Water Heater Flue Pipe: Single wall - Flat slope

Page 17 of 19 Marginal Summary (Continued) Bathroom 30. Family room Bathroom Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed 31. Family room Bathroom Ventilation: Electric ventilation fan - Loose cover 32. Hall Bathroom Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed 33. Hall Bathroom Faucets/Traps: Fixtures with a metal trap - Past leaks, Rust 34. Master Bathroom Ceiling: Drywall - Loose or peeling paint 35. Master Bathroom Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed 36. Master Bathroom Faucets/Traps: Fixtures with a metal trap - Past leaks, Rust Kitchen 37. 1st Floor Kitchen Trash Compactor: Functional - Noisy 38. 1st Floor Kitchen Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Missing outlet cover, Encase romex as needed Bedroom 39. Side center Bedroom Floor: Carpet - Stains 40. Front north Bedroom Floor: Carpet - Stains Living Space 41. Patio enclosure Living Space Windows: Wood casement - Screens loose/torn 42. Patio enclosure Living Space Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed 43. Family Room Living Space Floor: Carpet - Stains 44. Family Room Living Space Electrical: Outlets, lighting and ceiling fan - Missing switch cover 45. Dining/family Room Living Space Ceiling: Drywall - Cracks present 46. Dining/family Room Living Space Windows: Vinyl casement - Missing window crank knobs 47. Foyer/hallway Living Space Closet: Several - Door sticks 48. Foyer/hallway Living Space Ceiling: Drywall - Water stains present:inactive at this time Laundry Room/Area 49. Basement Laundry Room/Area Electrical: 110 VAC outlets and lighting circuits - Recommend GFCI's as needed, Single receptacle outlets recommended at washer/dryer 50. Basement Laundry Room/Area Laundry Tub Drain: Electric pump/pvc - Missing check-valve 51. Basement Laundry Room/Area Floor Drain: Surface drain - Missing cover

Page 18 of 19 Defective Summary IMPORTANT NOTE - PLEASE READ: The Marginal and Defective Summary pages are provided to allow the reader a brief overview of the report. This page is not encompassing. Reading this page alone is not a substitute for reading the report in its entirety. The entire Inspection Report, including the ASHI Standards of Practice limitation and Pre-Inspection Agreement must be carefully read to fully access the findings of the inspection. This list is not intended to determine which items may need to be addressed per the contractual requirements of the sale of the property. Any areas of uncertainty regarding the contract should be clarified by consulting an attorney or real estate agent. It is recommended that any deficiencies and the components/systems related to these deficiencies noted in the report be evaluated/inspected and repaired as needed by a licensed contractors/professionals PRIOR TO THE CLOSE OF ESCROW. Further evaluation PRIOR to the close of escrow is recommended so a properly licensed professional can evaluate our concerns further and inspect the remainder of the system or component for additional concerns that may be outside our area of expertise or the scope of our inspection. Please call our office for any clarifications or further concerns. Electrical 1. Basement Electric Panel Breakers: CU/AL - Double tap wiring on #1,5,7,12,21:fire hazard, Contact a qualified electrician for further evaluation:breaker connections appear to be rated for 2 wires but label rating reads 1 Structure 2. Foundation: Block - Cracked with displacement:approximately 1/2", A qualified contractor is recommended to evaluate and estimate repairs 3. Joists/Trusses: 2x10 - Mold visible mostly in laundry area - potential health concern Attic 4. Main Attic Sheathing: Plywood - Mold present:potential health concern 5. Main Attic Moisture Penetration: Yes - Mold present:potential health concern

Page 19 of 19 Defective Summary (Continued) Basement 6. Main Basement Electrical: 110 VAC outlets and lighting circuits - Loose wiring,outlet lying on floor, Incomplete, Missing outlet(s),switches etc. 7. Main Basement Moisture Location: Walls - Water stains present mostly in n.e. corner and front south wall adjacent garage:active, Mold present on floor joists:potential health concern Plumbing 8. Main Water Shutoff: Basement - Active leak(s) Bathroom 9. Family room Bathroom Toilets: Porcelain - Flush valve leaks 10. Master Bathroom Toilets: Porcelain - Flush valve fills very slowly, The tank is loose Kitchen 11. 1st Floor Kitchen Refrigerator: Side by side - Ice maker/water line leaks