HF Motion Sensor Introduction Completely built-in the lighting fixture, the motion sensor utilizes Doppler principle and RADAR technology to detect moving objects at certain speed & reflection surface, and gives output control signals to achieve on/off control, 2 steps dimming control, or 3-step dimming control function. A daylight sensor is also employed to set the threshold at which the motion sensor can be activated. With DIP switch, it is easy and accurate to select suitable detection area, motion hold-time, daylight threshold, stand-by dimming level, as well as stand-by period to fit for each specific installation. Sensors for On-off Control Super-compact Version Standard Version Flush Mounting Version HC005S page 16 HC009S page 19 HC002S page 107 The smallest sensor with DIP switch Loop-in and loop-out, easy wiring Condominium control DC Operation Version Detached Version Attachable Version HC501S page 88 HC009S-KD HC030S page 70 page 122 Input voltage 12V DC (24V/ 48V can be customized) Separate sensor antenna (3 types to choose), no shadow cast in LED bulkhead For external installation, attach to outside of fixture 01 Hytronik Microwave motion sensor
Sensors for 3-step Dimming Control (Corridor Function) Advanced Version Condominium Control Version Detached Version HC018V HC019V HC403V-KD page 22 page 26 page 73 1-10V output control Super compact size 2 or multi sensors control the same group of slaves Zero-cross relay operation Separate sensor antenna (3 types to choose), no shadow cast in LED bulkhead 1-10V output control 100 hrs burn-in for fluorescent lamp PWM Dimming Control Absence Detection Flush Mounting Version HC011D HC017V HC407V + HRC-02 page 77 page 91 page 111 Work with most ordinary non-dimmable LED drivers World-wide patented circuit For both Contant Current (350-1050mA) and Constant Voltage (20-90V) driver. Motion sensor won`t be activated until the push switch is short-pressed. With remote control 1-10V output control DALI Sensors This DALI sensor is designed for built-in lighting fixture, to be incoporated in the DALI system, taking command from the DALI master, accepting and carry out the grouping work with up to 64 luminaires, switch on/off, or dim the assigned group members, and feed back the status to the DALI master. HCD409 page 30 HCD402 page 105 HCD418 page 33 For DALI BUS power supply 16 groups selection via rotary switch 3-step dimming control For DALI BUS power supply 16 groups selection via rotary switch 3-step dimming control Flush mounting installation DALI power supply circuit inluded. 3-step dimming control independent DALI system Hytronik Microwave motion sensor 02
Integrated Motion Sensor LED Drivers Combination of HF motion sensor and LED power supply. Daylight Harvest Right time, right place and right amount of light! On--off Version SensorDIM Version (3-step dimming) Motion Sensor + Photo Cell + Remote Control HEC8025 page 37 HEC9025 page 41 HC407VDS + HRC-01 page 114 Multiple current selections Separate sensor antenna (3 types to choose) Multiple current selections Separate sensor antenna (3 types to choose) With built-in daylight sensor DS02, interact with daylight, and maintain the Lux level. page 99 Sensors with RF Wireless Transmission Control RF Transceiver RF Receiver (on-off control) RF Receiver (dimming) HC028V/RF page 45 HC023RF page 50 HC024RF page 55 Serve as both master & slave 3 rotary switches, one for sending RF signal and the other two for receiving RF signals. FSK 868/433/315/915MHz Slave only Rotary switch grouping before installation, easy to setup FSK 868/433/315/915MHz Slave only Rotary switch grouping before installation, easy to setup FSK 868/433/315/915MHz RF Transmitter RF Receiver (on-off control) RF Transmitter RF Receiver (dimming) HC018V/RF HC023RF page 61 HC018V/RF HC024RF page 65 On-off function only, with built-in daylight sensor Rotary switch grouping before installation, easy to setup 1-10V dimming control with built-in daylight sensor page 51 Rotary switch grouping before installation, easy to setup False Ceiling Sensors On--off Version 3-step Dimming Control Condominium Control PWM Dimming Control HC009S /EXT page 125 HC018V/EXT page 128 HC019V /EXT page 132 HC011D /EXT page 136 Condominium control 1-10V output control Condominium control Zero-cross relay operation Work with most non-dimmable LED drivers World-wide patented circuit For both Contant Current (350-1050mA) and Constant Voltage (20-90V) driver.
Dry-contact Sensors Standard Version Flush Mounting Version Alternating Version HC009SDC Loop-in and loop-out HC502SDC Input voltage 12V DC HC020SDC page 84 page 120 page 86 3-pole relay alternating control Voltage-free sensor Special Applications Converting daylight into 1-10V signal, and the control gear can compensate artificial light automatically according to the preset target Lux value. Specially designed for T8 LED lamp, ultra compact size for on/off and dimming control. This sensor shifts in between two different loads when movement is detected. Daylight Sensor Built-in Micro-sensor Alternating Version DS02 page 100 HCT8 page 80 HC021S page 94 Work with 1-10V control gear Dimming function Ambient daylight threshold For 100,000hrs lighting fixture Shifting in between two separate load, 2 steps dimming control function. Reinforced sensor for high-bay and warehouse installation. Detection height up to 12m. Reinforced Version For narrow detection, such as toilet compartment. Medium Range Sensor Phase-cut power output from the dimmer goes to the sensor first, controlled by the sensor, and then supplied to the luminaires. For Triac Dimmer HC009S /R HC002S /R page 97 /139 HC008S /M page 98 On/off control Ambient daylight threshold. On/off control HC402S /T page 117 On/off control. Triac dimmer decides the lighting level (1-100%) when motion detected. Hytronik Microwave motion sensor 04
Features 100hours burn-in 100H burn-in mode for fluorescent lamp Fluorescent lamp need 100 hours burn-in before dimming or freqently on/off switch to secure the rated life, when new fixture is installed, or old lamp is replaced. Rapidly turn off/on the fixture 3 cycles within 3 sec., the lamp is100% on, and then automatically goes to sensor mode after 100 hours. Ambient daylight threshold Ambient daylight threshold Rapidly turn off/on the fixture 2 cycles within 2 sec, the sensor can set the ambient daylight level as threshold. This feature enables the fixture to function well in any real application circumstance, as the daylight penetrated into fixture may vary a lot. The latest surrounding lux value (either the setting on DIP switch or the learned ambient lux threshold) can overwrites previous lux value learned. The latest action stays in validity. Zero-cross relay operation Designed in the software, sensor switches on/off the load right at the zero-cross point, to ensure the min. current passing through the relay contact point, and enable the max. load and life-time of the relay. zero-cross points alternating current Condominium control Condominium control function In many cases, several sensors are connected together to control the same fixture, or to trigger on each other, the sudden on/off of the lamp tube or the ballast/driver causes huge magnetic pulse, which may mis-trigger the sensor. The sensor has a very advanced software to ignore that interference, and keep each individual sensor functioning well. Loop in Loop out Wire loop-in and loop-out To save cost and assembly work, all Hytronik sensors are designed with L and N for power in, and L and N for power out to the load. Easy, nice and clean. Latest DALI protocol for sensor control Being a member of the DALI group, Hytronik sensor is always keeping up with the latest DALI standard for sensor controls. We offer both DALI sensors for big DALI system as well indepandant DALI sensors (containing DALI power supply) for small and medium projects and installation. Product Benefits Tailor-made for automatic lighting intelligent application. Totally enclosed in fixture, there is no need to keep the sensor head sticking out of the fixture thanks to microwave that can penetrate any non-metal objects. Extremely low transmission power, <2mW, 2% of mobile phone. With RF wireless KEELOQ coding system and rotary switch grouping, perfect for renovation of old project. Multi options on daylight threshold, holdtime, stand-by brightness and stand-by period of corridor function. With both 230V and 1-10V output interface for various lighting control. Working temperature: -35 ~+70. Suitable for outdoor application. Typical Lighting Applications: This sensor can be built in totally enclosed lighting fixture thanks to microwave technology. The combination of this sensor and any ordinary 1-10V dimmable control gear can easily achieve fully automatic intelligent lighting control. Perfect to apply on public area like corridors, side walks, parking garage, warehouse, as well as big office areas to save every possible watt. 07 Hytronik Microwave motion sensor
Super compact sensor HC005S LED array LED linear fixture For LED bulkhead For 2D 28/38W lamp For LED panel light, motion sensor with daylight harvest Installation 1 Always keep the antenna at least 5mm above the metal mounting surface to avoid mis-trigger problem. 2 High metal wall also blocks and reflects microwave. Do not put the sensor deeply in metal wall. Keep the sensor to the openning as close as possible. The antenna is at the same level of the metal plate. Keep the antenna at least 5-6mm above the metal plate Warranty Hytronik offers 5 years product warranty to cover all kinds of product manufacturing defects, and Hytronik will be reliable for the cost envolved: 1. For product in HYTRONIK original brand, Hytronik takes care of all related cost including product cost, replacement cost etc. For the first 3 years; and only product cost for the rest 2 years. 2. For OEM customer branded product, Hytronik only takes care of the product cost. Others 1 The sensor relay has a lifespan of 300,000 cycles at the rated max. load. However if the actual load is below the rated max. load, the actual lifespan will be easily prolonged by 2x, 5x, or even 10x! 2 Great savings on electricity can be easily achieved with the employment of motion sensor. Hytronik has formulated a calculation tool for customers to simulate how much energy can be saved, how much less CO2 emmision can be reduced and how long is the payback period when applying the sensors for retrofit the old on/off installations; change over to sensordim, or ultimately adopt our constant lux control system --- daylight harvest system. Please log in WWW.HYTRONIK.COM to download the calculation tool and see what you can do to contribute in the reduction of CO2 emmission! Hytronik Microwave motion sensor 08