Congress Elementary School (Milwaukee, Wisconsin) Human Factors Evaluation

Similar documents
Solon High School (Solon, Iowa) Human Factors Evaluation

NRG SYSTEMS, HINESBURG, VT

Buidling 661 Annual Daylight Performance Modeling Studies

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

Daylighting Control Design and Application Guide

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

Main Lobby Area (North Vestibule thru South Vestibule):

Lighting Application Guide for K-12 Classrooms

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

Thesis Proposal Update #2

Lindsey Beane. Executive Summary

Lord Stirling Community School

Hawthorn Building. Penn State Altoona Campus Altoona, PA. Walter Nichols. Lighting/Electrical Option Faculty Advisor: Dr.

1. Select the group that best represents your connection with Eagle Hall.

Safety Lighting. Safe also without electricity. Standards SIST EN 1838: 2011 ISO (2007) CIE S 020 (2007)

CENTRAL KITSAP SCHOOL DISTRICT BOARD PROCEDURE

Daylight and Whole-Building Energy Analysis Using Radiance in IES <Virtual Environment>

Advanced Lighting For Office

Technical Report One

Some Basics of School Library Design

Reducing Barriers to Use of High Efficiency Lighting Systems Oct. 2001

BUG stands for Backlight, Uplight and Glare. The acronym

Serie 3 Interaction Design Basics, HCI in the Software Process & Design Rules

Technical Assignment I

FUTURES EVALUATION REPORT. Prepared for Yolo Farm to Fork. December 29, Gail Feenstra and Shosha Capps

Vernonia K-12 School: Thermal Comfort in Passively-Cooled Zones

University of California Santa Barbara. Student Resource Building

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

Gathering Space. Function and Orientation. Space Characteristics Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

Quality of the Visual Environment

SCC BULLETIN DPS/SCC Directive Date of issue: December 4, 2002

Lighting System Conceptual Design

Overview. The Reading Room

Carpenter Center Cambridge, MA DAYLIGHT AS A DESIGN FACTOR Anahita Anandam

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Reduce lighting energy costs with controls

Lighting Control Strategies. to meet code requirements save energy and improve building performance

A Guide for Applicants and Lighting Designers

Lighting Design Criteria: Codes and Standards

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

MATHEMATICAL SCIENCES BUILDING

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

LUMINOUS ENVIRONMENT AND OCCUPANT S SATISFACTION AT OPEN- PLAN OFFICE (Case Study: Jawa Pos Office, Grha Pena 4 th Floor, Surabaya)

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

Café DUSON- Overview

Balance LC. classroom light control fixture solution. simple to order simple to install simple to use

Working Together to Keep our Kids Safe. Baker Middle School Families + Staff + Montgomery County Police Department = Safety

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

TECHNICAL ASSIGNMENT #3: SCHEMATIC LIGHTING DESIGN

PLATTEVILLE MIDDLE SCHOOL

Lighting Existing Conditions and Design Criteria Report

Lighting Proposal Memo. Lighting Proposal. Angela Nudy Lighting/Electrical Dr. Mistrick Lighting Proposal Memo 1

High Performance Lighting. Terry Egnor Senior Consultant NBI

B115/B116, B117, B118, B132, B205, B206,

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Lighting in the workplace is it just about vision?

Adopted February 1977 Recoded May 1998 Revised September 2007 Reviewed July 2014 Revised July 2017 EMERGENCY DRILLS

AR Wickes Elementary School (Cossatot River School District) 130 School Drive Wickes AR School Parent and Family Engagement Plan

If the address on this form is different than the address of the building, submit a written explanation.

600 Watt Dimmer Install Guide


Optimizing the Radiance Workflow: In an Integrated Firm Environment

WSA120: New Energy Codes and Lighting Controls

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

HOT IN HERE: OFFICE OCCUPANT THERMAL COMFORT IN LAWRENCE HALL

West International House Fire Plan Updated: September 14, 2010 By: Resident Manager

Section 3. Preparedness. Shelton School District Emergency Response Plan

Duke Tower Main Entrance Lobby Overview

A DAY BEACH LIGHTHOUSE DENTAL

Windows Influence on Room Daylighting in Residential Buildings

Acknowledgement: Ralph Prahl, Prahl & Associates, contributed critical review and analysis

If the address on this form is different than the address of the building, submit a written explanation.

Design and Build a. Solar House. Introduction. Design a model house that uses as little energy as possible to keep it warm.

Course Syllabus LIGHTING DESIGN

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Energy Audit. This guide is for a 6 month Silver Award project. It is suitable for both group and individual volunteering.

CAC OVERVIEW. CAC Roles and Responsibilities CAC Operations CAC Membership CAC DAC Relations

Variable Light and Shade. Flexible sun and glare protection systems

Advances in Non-Residential Lighting Technologies

Incorporating Lights in the Landscape

Morning Announcements Energy Savings Tips for Students

Lobby Lighting Design

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

NEW ELEMENTARY SCHOOL AT THOMAS JEFFERSON MIDDLE SCHOOL

B115/B116, B117, B118, B132, B205, B206,

Product Specifications Dialog Room Controller* (*patent pending)

POST OCCUPANCY REVIEW LED INSTALLATION

Solid State Lighting

Home Energy Audit. Overview. Objectives. Time Requirements. Materials. Procedure CON EDISON WEB-BASED MIDDLE SCHOOL ACTIVITY

Rethinking Bexley Hall

EXEMPLAR: School Grounds and Gardens

High Five for Saving Energy!

Transcription:

ENERGY SMART SCHOOLS: APPLIED RESEARCH, FIELD TESTING, AND TECHNOLOGY INTEGRATION Congress Elementary School (Milwaukee, Wisconsin) Human Factors Evaluation SEPTEMBER 2004 Published by the Energy Center of Wisconsin for the United States Department of Energy and National Association of State Energy Officials (NASEO) 455 Science Drive, Suite 200 Madison, Wisconsin 53711 608.238.4601 www.ecw.org

PROJECT OVERVIEW The Association of State Energy Research and Technology Transfer Institutions, Inc. (ASERTTI) and the National Association of State Energy Officials (NASEO) with the Department of Energy (DOE) and the EnergySmart Schools Program conducted a joint project that encompassed applied research, field testing and technology integration. The following organizations worked collectively to conduct this research: Energy Center of Wisconsin Iowa Energy Center Lighting Research Center Lawrence Berkeley National Laboratory Dalhoff & Associates Fort Collins Utilities As part of the overall project there were eight distinct tasks outlined, each with its own set of goals, activities and deliverables. This document was created as part of Task 4: Advanced Daylighting Research.

Congress Elementary School Milwaukee, Wisconsin Daylight Human Factors Evaluation Report submitted to: Energy Center of Wisconsin Project J30447 Energy Smart Schools Report submitted by: Lighting Research Center December 11, 2003 (Revised January 2004) (Reformatted July 2004)

Table of Contents Congress Elementary School Milwaukee, Wisconsin Evaluation Summary 2 Site Conditions 5 Appendix A: Teacher/Staff Interviews 6 Appendix B: Teacher Survey Answers.. 9 Appendix C: Daylighting Evaluation Survey Form (Blank) 10 Appendix D: Window Luminance and Transmittance 11 Appendix E: Window Blind Use During Visit. 13 Appendix F: Horizontal Illuminance Measurements 14 Appendix G: Site Plan and Horizontal Illuminance Measurement Points... 15 Appendix H: LRC Contact Information... 16 July 2004-1 - Lighting Research Center

Evaluation Summary: Congress Elementary School, Milwaukee, WI The use of Cool Daylighting principles at Congress Elementary school creates a pleasant visual environment that is well-accepted by the teaching staff. The extensive use of Venetian blinds and roller shades may, however, have an impact on energy savings. Energy analysis will be addressed by other researchers. The following summarizes the results of the human factors evaluation by the Lighting Research Center (LRC) in September 2003. This school has two Cool Daylighting copy classrooms with special glazing and blinds. One of these two rooms (Room 10) has full photosensor-controlled lighting as well. The third room is a base case (Room 8), with existing windows and electric lighting. All three classrooms face east (see plans, Appendix G). For more information about the site, see Site Conditions and appendices, attached. Researchers from the LRC visited Congress Elementary school in the day and evening in mid-september 2003. The LRC is charged with evaluating the human factors condition at the copy rooms; energy use will be monitored by other parties. Due to hesitance about subjecting students and teachers to productivity and visibility testing, our human factors study focused on acceptance. We interviewed the teachers who use the rooms with new blinds and tinted windows. There art teacher who regularly uses the base case classroom was away on maternity leave, so very little human factors evaluation was done in that space. We did interview a visiting teacher who was working in room 8. The LRC attempted to survey the children using a raise of hands method. However, since the children were only in the first and second grade, many of the concepts were too complex for the students to understand. We are therefore relying on interviews with the teachers for feedback about acceptance of the new windows and lighting. (Other schools that will be included in this study have older students, which will permit wider use of surveys.) To support the human factors evaluation, the LRC also measured the photometric conditions in all three classrooms at several times in the day (see Appendix A). The lighting system in Room 10 successfully maintained the design illuminance (500 lux) throughout the day, even exceeding minimum requirements in the morning. As indicated above, the LRC did not attempt to monitor energy use in the space. In both rooms, the LRC found that blinds tend to be down on the upper clerestory windows, thus limiting the amount of available daylight (see Appendix E). Upper blinds were difficult for teachers to access. In each room, blinds must be closed for frequent audio/visual presentations. We noticed one teacher balancing on a chair to access the upper blind controls. Lower blinds were easier to access, but also tended to be left down. These teachers were too busy looking after their students to be willing to adjust the 18 sets of blinds repeatedly. It is understandable, therefore, that blinds tended to remain down or closed. It may be valuable to provide blinds for the clerestory that are easier to access, or perhaps adjust automatically. July 2004-2 - Lighting Research Center

Also limiting available daylight was the use of the upper clerestory windows for display of learning aids such as posters. This space had previously been opaque wall, so the teacher was accustomed to using it for display purposes. Since the photosensors in Room 10 are located in the room ( closed loop ), lighting energy savings in Room 10 may be undermined if blinds and learning aids block daylight. Learning aids in Room 10 Proponents of the use of daylighting in classrooms may wish to consider other possible reasons why blinds may be left closed. A visiting teacher reported that she once had a principal who established strict rules about how blinds should be used, so that the school looked tidy and under control from the outside. Keeping blinds closed gives a uniform look of the outside of the building, which is particularly important for schools in economically disadvantaged areas. (Congress School does not have such a policy.) Other view issues were identified in the teacher interviews. Lower blinds may be closed to prevent view from the exterior (and theft) of valuable computers. Also, lower blinds are closed to prevent students from being distracted by exterior gym classes. Before proposing the use of blinds for future projects, it would be valuable to confirm with administrators whether blinds may be used for reasons other than visual comfort. The use of blinds may impact daylight energy savings. Teachers find the visual environment in the two copy rooms to be comfortable. Neither complained that the new tinted glass looked dark. Both the clerestory and view glass are tinted (18% and 23% visible transmittance). Indeed, LRC researchers found the extreme tinting of the glass to be indistinguishable from clear glazing classroom environments. This is likely due to the fact that all the glazing in the room is tinted; there is no visual cue to actual exterior luminances, so the space actually appears quite cheerful and bright compared to the base case (in which blinds were closed). Light levels from the new luminaires in Room 10 were equivalent to those with the old lighting in Rooms 8 and 9. In general, the teachers were satisfied with the quantity and distribution of electric light for both the old and the new lighting systems. There were no complaints of premature failure of the dimmed lamps in Room 10. The teacher enjoyed having a wall box dimmer to occasionally override the light levels. The teacher in Room 10 did not notice the electric lights automatically dimming throughout the day. (Note: The LRC was not able to confirm control settings, or even whether the system was working properly.) In summary, the use of Cool Daylighting principles at Congress School has provided a visual environment that was acceptable to the teachers. There may, however, be reduced energy savings due to the widespread use of blinds. July 2004-3 - Lighting Research Center

Room 8, base case condition Room 9, new windows with old lighting Room 10, new windows and new lighting July 2004-4 - Lighting Research Center

Site conditions General: See plans, Appendix G Inner-city school Year-round operation Young children, approx. 5-12 years old (K-6) Three east-facing rooms studied: one with cool daylighting windows and lighting, one with new windows old lighting, and one base case with old windows and lighting Architectural: No overhang East-facing windows Continuous windows, not punched openings Lower windows are tinted, probably Viracon type VE3-40, 18% visible transmittance (see photo); feedback from Viracon corresponds to field measurements (see Appendix D) Upper clerestory windows are tinted as well Viracon VE3-55, 23% visible transmittance Upper blinds are white Venetian blinds Lower blinds are black perforated roller shades Lowest segment of lower windows is operable with a screen that reduces transmittance Original fenestration and new tinted glass New lighting: Pendants with 32 stem, with perforated metal reflector wings that can be opened to allow Cool Daylighting windows and lighting uplight on the ceiling; most were in open position. (The same luminaire was used at Zach Elementary School. See this separate report.) Two lamps in cross section, four lamps per eight-foot luminaire Dimming ballasts Two fixtures per bay, three bays per room The three fixtures closest to window are controlled by one photosensor built into the end of one fixture, facing downward (see photo) The three fixtures in the rear of the room are controlled by a second photosensor, mounted in same manner New lighting has different layout than old lighting, but seems to use the same number of lamps Photosensor built into luminaire July 2004-5 - Lighting Research Center

Appendix A: Teacher/Staff Interviews Teacher, Room 10 (east-facing room with new windows, blinds, and lighting) General: The teacher had worked in this room before and after the renovation. Teachers have been encouraged to move the artwork to the lower windows from the upper windows. This teacher feels the upper windows did eat up her display space; in the past she used this as mounting space because it was opaque. The chalk board on north side is not used. Blinds: Most of the time the teacher operates the blinds, not the students. If she doesn t close the upper blinds, the students squint a little. In mornings, all blinds are closed because eastern exposure is too sunny. The teacher stated that she puts top blinds down and open in morning to reflect light off ceiling (Note: Most appeared to be closed during our morning visit. See Window Blinds, Appendix E.) This class uses one window for calendar when they log weather. o Due to black perforated roller blinds on lower windows, every day the students think the weather is overcast. o For this reason the teacher instructs the appointed weather monitor student to walk over to one window and look out at the sky. o The lower blinds on this one window seem to remain open. In afternoon after recess, the teacher opens the blinds, depending on the weather. Sometimes the lower blinds are closed not for lighting reasons, but to block the view of gym classes, which are distracting to the children. The teacher says usually the middle three window (the center bay ) blinds are more frequently adjusted. The teacher rarely opens the blinds next to the computer, even though the computer is not working right now. Lighting: The white board in the rear of the room is the only dark spot. Opening the wings on the fixture has helped. The teacher uses the dimmer override to turn down the lights to the lowest setting during DOL time. DOL is Daily Oral Language, when they work on grammar, sentences, etc. She uses the overhead projector during DOL. This requires low ambient light levels. The teacher likes the lighting better now that she has learned to open the flaps on the light fixtures. Open is better for lighting. (Note: Opening flaps creates uplight.) The teacher likes dimming as an improvement to just shutting off lights. When the students write and she plays classical music, they say ooo when she dims the lights. After lunch she dims the lights to calm the children down when they are overly energetic. Lights are not turned off, but are dimmed to the lowest setting. (LRC nighttime measurements showed that the minimum dim level was 20% of full output.) July 2004-6 - Lighting Research Center

Teacher, Room 9 (new windows, old lighting) This room has only the special windows and blinds, but not the special new lighting. The teacher says she leaves blinds all open on top. However, the LRC noted that the upper blinds were down, and many were closed (see Appendix E). LRC researchers observed that the teacher had to stand on a chair to close one upper blind during the morning class. Teacher keeps the black perforated (lower) blinds raised to the level of the operable window mullion. See survey (Appendix B) for other comments. Room 8, visiting mentor in control room (old windows, blinds, and lighting) This room is not used by a regular teacher or class; on the day we visited it was being used for speech therapy. There was also evidence of use for art instruction. This visiting mentor has been an educator since 1968. The mentor doesn t think lighting is very important unless it is very bad. The mentor turns off the lights after recess to calm the students down. The blinds are closed for property security after hours. Keeping blinds closed gives a uniform look of the outside of the building, which may be important to some principals because it reflects on the overall administration of the building. This mentor once had a principal who established strict rules about how blinds should be used, so that the school looked tidy and under control from the outside. Henry, maintenance specialist Henry works second shift. Henry changes light bulbs, among other duties. Henry began work there in February 2003; his predecessor was present for installation of the new lighting and windows, not he. He uses a spot relamping strategy. No lamps have failed since February 2003 (seven months). He has the electrician s contact info if necessary. Class 10 bulbs are OSI T8 3500K 835/XP. The old, existing fixtures use one lamp in cross section. Meeting with school district administrators including Tom Chojnacki, Manager of Environmental Services Administrators are trying to increase school stock in inner city to reduce busing costs. The schools do have air conditioning. The schools are in session 180 days a year, and do operate in the summer. They have more breaks throughout the year that are longer. o Air conditioning is unusual in Milwaukee. Thirty percent are air-conditioned, although this is increasing. o Air conditioning is a requirement of year-round schooling. o The district is moving towards more year-round schooling as a standard. The school district would have to see results of energy monitoring before they decide to revise the lighting and windows in more schools. o An energy case study is desirable to compare these three rooms, the control room, windows only, and windows + lighting. July 2004-7 - Lighting Research Center

Teachers were not told how to use shades and fixtures, which would be of value in the future. o Dean Schultzbank, WE Energies account manager commented that he thinks teachers should be influencing design. Not to have influence could be frustrating to teachers. The teachers need to be included in the design process. o The teacher loses the upper window space, which was a type of bulletin board. The teacher complained right away (see interview). This design and installation process has gone on for 2+ years. o School administrators toured the Appleton, Wisconsin school copy room. Teachers change rooms from one year to the next The east-facing room orientation was chosen by Steve Ternoey, consultant to Energy Center of Wisconsin. Follow-up telephone interview with Principal Jacqueline Patterson December 11, 2003 Room 8 is used primarily for art instruction The art teacher is on maternity leave until February 2004 (at least) There have been substitute teachers, but not ones who have worked in the space for a long period of time, who could comment on multiple seasons and weather. Principal Patterson cannot offer an e-mail address or other contact information for the art teacher in the interim Principal Patterson says that blinds are in fact opened during class, as part of the teaching methodology There is no policy at this school to keep blinds closed or opened She has heard positive feedback from the teachers in rooms 9 and 10 about the new windows and lighting July 2004-8 - Lighting Research Center

Appendix B: Teacher Survey Answers See Appendix C for blank version of survey. Similar surveys were used at the other schools. Teacher, Room 10 Teacher, Room 9 Lower windows, when sunny: Comfortable Comfortable Lower windows, when cloudy: Dark, when shades down Comfortable Upper windows, when sunny: Comfortable Comfortable Upper windows, when cloudy: Comfortable Comfortable Lower blinds block of the light, AM: Lower blinds block of the light, PM: Upper blinds block of the light, AM: Upper blinds block of the light, PM: It is too dark: There is too much light: Do you notice the electric lights dimming up and down? Do you find the dimming distracting? All Half Most Most Never, except at dry erase white board Never; shades make it acceptable if there were no shades, there would be too much light No No A little A little Never Sometimes, due to weather condition. She shuts off lights for quiet time or "time out" N/A didn't have special lighting N/A Do you find the electric lighting uncomfortably bright? No No (has existing lighting) Compared to other classrooms at other schools, the lighting in this classroom is Comments Better, because it doesn't seem as glaring See report About the same (has existing lighting) She likes the perforated roller shades July 2004-9 - Lighting Research Center

Appendix C: Daylighting Evaluation Survey Form (Blank) Room # Teacher: Date: n = students When you look at the LOWER windows, you find them: When sunny:>>> Too dark Dark Comfortable Bright Too bright When cloudy:>>> Too dark Dark Comfortable Bright Too bright When you look at the UPPER windows, you find them: When sunny:>>> Too dark Dark Comfortable Bright Too bright When cloudy:>>> Too dark Dark Comfortable Bright Too bright When you use this classroom, how much of the light are the LOWER BLINDS blocking? All Most Half A little None When you use this classroom, how much of the light are the UPPER BLINDS blocking? All Most Half A little None How frequently is it TOO DARK in this classroom? Never Sometimes Often Always (If Sometimes or Often ) This was this due to the: Type of activity Weather condition Please describe How frequently is there TOO MUCH LIGHT in this classroom? Never Sometimes Often Always (If Sometimes or Often ) This was this due to the: Type of activity Weather condition Please describe Do you notice the electric lights automatically DIMMING UP AND DOWN? Yes No Do you find the dimming DISTRACTING? Yes No Do you find the electric lighting uncomfortably bright? Yes No Compared to classrooms at other schools, the lighting in this classroom is. Better About the same Worse Any comments about the windows, blinds, or electric lighting in this classroom? July 2004-10 - Lighting Research Center

Appendix D: Window Luminance and Transmittance a LRC researchers took luminance measurements during actual class time to compare to the teachers reports of visual comfort levels. Researchers tried to minimize disruption to the class by measuring the two states that are primarily used, upper blinds down/open and upper blinds down/closed (point a). Since teachers do open lower roller shades, points b and c include shades down and up. Electric lights were on during measurements. b c In Room 10, LRC researchers also attempted to verify window transmittance by holding an illuminance meter against the glass, compared to illuminance at an open window. Window measurement points Room 8 Luminances (Room has old roller shades, old lighting) Approx. 2:40 p.m., partly cloudy Blinds Closed Comments Point a N/A Top segment opaque, no glass Point b 14,000 cd/m 2 View of white cloud 2900 cd/m 2 View of blue sky Point c 1600 cd/m 2 View of asphalt blacktop Note: Blinds seem to remain closed; this room is not occupied consistently Room 9 Luminances (Room has new blinds and windows, old lighting) Approx. 10:30 a.m., mostly sunny Blinds Down/Closed Blinds Down/Open Comments Point a 350 cd/m² 890 cd/ m² Upper blinds always down Point b 70 cd/ m² 1020 cd/ m² Lower blinds up when open Point c 19 cd/ m² 350 cd/ m² Lower blinds up when open July 2004-11 - Lighting Research Center

Room 10 Luminances (Room has new blinds, new windows, new lighting) Approx. 9:50 a.m., sunny Blinds Down/Closed Blinds Down/Open Comments Point a 732 cd/m 2 1266 cd/m 2 White blinds; clear sky view Point b 82 cd/m 2 1571 cd/m 2 Black blinds; clear sky view Point c 25 cd/m 2 250 cd/m 2 Black blinds; blacktop view Approx. 2:20 p.m., partly cloudy Blinds Down/Closed Blinds Down/Open Comments Point a 66 cd/m 2 1800-2100cd/m 2 View of cloud Point b 70 cd/m 2 3400-4000cd/m 2 Black blinds; cloud view 800 cd/m 2 View of clear sky Point c 15 cd/m 2 150-200 cd/m 2 Black blinds; blacktop view Room 10 Window Transmittance Verification Approx. 9:50 a.m., sunny Illuminance Transmittance Comments Point a 14,500 lx 30% Point b 14,800 lx 30% Point c 10,300 lx 21% This window has a screen Point c, opened window 49,000 lx 100% This window has a screen Approx. 12:05 p.m., sunny Illuminance Transmittance Comments Point a 2,600 lx 18% Point b 2,900 lx 20% Point c 2,200 lx 15% This window has a screen Point c, opened window 14,200 lx 100% This window has a screen Approx. 2:20 p.m., partly cloudy Illuminance Transmittance Comments Point a 2,400 lx 26% Point b 2,360 lx 25% Point c 1,450 lx 16% This window has a screen Point c, opened window 9,300 lx 100% This window has a screen July 2004-12 - Lighting Research Center

Appendix E: Window Blind Use During Visit In rooms 9 and 10 (those with new windows), there are 18 sets of blinds to adjust, 9 upper blinds and 9 lower blinds. The graph below shows that nearly all windows in the Cool Daylighting demonstration have window blinds down, and most are fully closed. This will likely affect energy savings from photosensor-controlled electric lighting. Use of Blinds Congress Elementary School, Milwaukee, WI (Rooms 9-10, East-facing) Blinds down and CLOSED Clerestory Windows View Windows 64% 85% Blinds down and OPEN 0% 31% Clerestory Windows View Windows (Not applicable for roller shades) Blinds UP 6% Clerestory 15% View Windows 0% 20% 40% 60% 80% 100% July 2004-13 - Lighting Research Center

Appendix F: Horizontal Illuminance Measurements Horizontal illuminances were measured with blinds as they are actually used by teachers (usually blinds were closed). Room 10 has photosensor-controlled dimming. Since the LRC's responsibility was human factors evaluation, no attempt was made to monitor electric light power levels during the day. Refer to Appendix G for measurement points. Room 10: New windows and new lighting Room 9: New windows, old lighting Room 8: Base case, old windows, old lighting Point A Point B Point C Point D Point E Point F Point G Point H Point I Desk ht 9:10 a.m., sunny Only one lower blind open 10:30 a.m., sunny; lower blinds open to lower window 8:50 a.m., sunny; blinds down all the way 23" 1030 lx 630 lx 630 lx 760 lx 660 lx 650 lx 29" 580 lx 640 lx 617 lx 12:05 p.m., now partly cloudy 23" 610 lx 602 lx 590 lx 2:20 p.m., partly cloudy, blinds haven't moved 2:30pm, blinds still down 23" 606 lx 540 lx 600 lx 29" same as 9:00 a.m. 7:45 p.m., after dark 23" 583 lx 528 lx 620 lx Room 10: One lower blind Room 9: All lower blinds Room 8: Blinds always open for weather monitoring open to lower window closed July 2004-14 - Lighting Research Center

Appendix G: Site Plan and Horizontal Illuminance Measurement Points (See Appendix F for illuminance measurements.) July 2004-15 - Lighting Research Center

Appendix H: LRC Contact Information The following parties can be contacted for more information as follows: Lighting Research Center 21 Union St. Troy, NY 12180 (518) 687-7100 Project Manager, Site Evaluator, Report Author: Site Evaluator: Associate Director, Daylighting Expert: Human Factors Methodology Development: Publication Editing and Layout: Jennifer Brons Julle Oksansan, visiting scholar Russell Leslie Peter Boyce, PhD Yukio Akashi, PhD Dennis Guyon Researchers from LRC wish to express their appreciation to the following individuals for their assistance in the evaluation at Congress School: Thomas Chojnacki, Manager Environmental Services, Milwaukee Public Schools Jacqueline Patterson, Principal, Congress Elementary School July 2004-16 - Lighting Research Center