Pressure drop analysis of Condenser using refrigerants R-134a, R-407C

Similar documents
Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Performance Study of Triple Concentric Pipe Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Enhancement of COP using Nanoadditives in Domestic Refrigerator

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Global Journal of Engineering Science and Research Management

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Compression of Fins pipe and simple Heat pipe Using CFD

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Enhancement of COP in Vapour Compression Refrigeration System

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Waghmare Tushar Ramrao, D.S.Nakate

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

2. HEAT EXCHANGERS MESA

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

DEEPAK PALIWAL, S.P.S.RAJPUT

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Mallikarjun 1, Anandkumar S Malipatil 2

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Adsorption refrigeration system using waste heat

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Performance Optimization of the Evaporative Condenser Design

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

Performance investigation of Air-conditioning system using ejector as expansion device

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

II. OBJECTIVE OF RESEARCH

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

ENSC 388: Engineering Thermodynamics and Heat Transfer


Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Refrigerant Glide and Effect on Performances Declaration

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

CHAPTER 1 INTRODUCTION

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Low GWP Refrigerants for Air Conditioning Applications

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Investigation and Optimization of Air Cooled Condenser of Chillers by Replacing Cu to Al Tubes

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Performance of an Improved Household Refrigerator/Freezer

FUNDAMENTAL BASIS AND IMPLEMENTATION OF SHELL AND TUBE HEAT EXCHANGER PROJECT DESIGN: EVAPORATOR STUDY

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

η second law = Second law efficiency

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Investigation of Evaporator Performance with and without Liquid Overfeeding

Transcritical CO2 Bottle Cooler Development

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Transcription:

Pressure drop analysis of Condenser using refrigerants R-134a, R-407C #1 Sachin N.Jadhav, #2 Dr. Pradeep A.Patil #12 Department of Mechanical Engineering, Savitribai Phule University of Pune, Pune, India. ABSTRACT This paper presents experimental study of effect of Pressure Drop on a shell side in a Condenser. Their are Two different Refrigerants are used i.e.r-134a and R-407C. Then all this test are conducted in a Test rig set-up. In this paper are performed for various condensing temperatures and evaporating temperatures. The test runs are performed for each average saturated condensing temperatures ranging from 38.6 ᵒC to 45.6 ᵒC for which evaporating temperatures are varied. The experimental results were studied for effect of mass flow rate on shell side pressure drop and friction factor. It indicates that the frictional pressure drop increases whereas friction factor decreases with increase in mass flow rate. It is observed that frictional pressure drop for R-134a is more than R-407C.If allowable pressure drop range is 0.8 Pa. Keywords STHE, Pressure drop, Frictional factors, Mass flow rate, condensing temperatures and evaporating temperatures. I. INTRODUCTION Heat exchanger is a device to transfer the thermal energy ie. enthalpy between two or more fluids, between a solid surface and solid particles and a fluid at different temperatures In thermal contact. In a heat exchangers there are no external heat and work interactions.heat exchanger is a wide variety of applications such as Air-conditioning, Petrochemical industries, space applications, manufacturing industries, milk pasteurization industries, waste heat recovery, power generations etc. In most heat exchangers the heat transfer between fluid takes place through a separating wall. Such heat exchangers rate the fluids are by heat transfer area, and they do not mix or leak such heat exchangers are direct transfer type. Exchangers in which there is a intermittent heat exchangers between the hot and cold fluids via thermal energy storage and release through the exchanger surface. The heat exchanger are broadly classified as : according to transfer process,according to number of fluids, surface compactness, according to construction, flow arrangements, heat transfer mechanism. But in this paper only studied the shell and tube heat exchanger. It is a type of tubular heat exchanger. Tubular heat exchangers can be designed for high pressure Tubular exchangers can be designed for high pressures relative to the environment and high-pressure differences between the fluids. Tubular exchangers are used primarily for liquid-to-liquid and liquid-to-phase change (condensing or evaporating) heat transfer applications. They are used for gas-to-liquid and gas-to-gas heat transfer applications primarily when the operating temperature and pressure is very high. Fig.No.1 Shell and tube Heat Exchanger. In above fig. shows that a Tubular type shell and tube heat exchanger. In this exchanger no. of tubes mounted in a cylindrical shell. One fluid flows inside the tubes and other flows across the means in shell side. the major components of this exchangers are tube sheets, plate baffle spacing, tubes or tubes bundle, shell, front end head, rear end head. The internal constructions is depending on the pressure drop and heat transfer,thermal stresses, to control corrosion, to containing operating temperatures and pressures, to prevent leakages. In shell and tube heat exchangers classified widely used in a TEMA standards.(tubular Exchanger Manufacturers association). TEMA standards specify the manufacturing tolerances for various mechanical classes,the range of tube sizes and pitches, baffle space and plates, tube sheet thickness formula, pressure classification and so on. widely used in industries because operating 2015, IERJ All Rights Reserved Page 1

condition such as from high vacuum to ultra high pressure(100mpa).it can be designed for special operating conditions :erosion, corrosion, toxicity, vibration, highly viscous fluid, multi component mixtures, density of fluid, flow of fluid. II. LITERATURE REVIEW Heat transfer coefficient and pressure drop on the shell side of a shell-and-tube heat exchanger] have been experimentally obtained for three different types of copper tubes (smooth, corrugated and with micro-fins). Also, experimental data has been compared with theoretical data available. Correlations have been suggested for both pressure drop and Nusselt number for the three tube types. A shell-and-tube heat exchanger of an oil cooler used in a power transformer has been modeled and built for this experimental work in order to investigate the effect of surface configuration on the shell side heat transfer as well as the pressure drop of the three types of tube bundles.[ R. Hosseini, A. Hosseini-Ghaffar and M. Soltan Vol.27,April 2007] They have presented a compact formulation to relate the shell-side pressure drop with the exchanger area and the film coefficient based on the full Bell Delaware method. In addition to the derivation of the shell side compact expression, they have developed a compact pressure drop equation for the tube-side stream, which accounts for both straight pressure drops and return losses. They have shown how the compact formulations can be used within an efficient design algorithm. They have found a satisfactory performance of the proposed algorithms over the entire geometry range of single phase, shell and tube heat exchangers. 3.Saunders in his book proposed practical method and simple design factors are provided and the method is used rapidly for fixed set of geometrical parameters. In his work the correction factors are for heat transfer and pressure drop correlations.[ M.Serna and Hydro-fluorocarbon (HFC) refrigerants, like R134a and zero-tropic refrigerant mixtures like R407C have been introduced in order to replace R12 and R22, respectively. As per the agreement done in The Montreal Protocol, efforts towards the replacement of these refrigerants are under progress. For the optimum performance, an accurate design technique is essential for the prediction of refrigerant pressure-drops and flow-patterns through the evaporator, condenser and other heat exchangers (Smith et al., 2001). Experimental setup : The actual photo of set up is shown in above fig. The test rig was vapor compression cycle along with some additional components and instruments to maintain desired operating condition to measure the parameters at various location for study. The setup used for the experiments is a Compressor-Calorimeter test rig, as shown in fig. 1, which can also be used to analyze Vapor Compression Cycle (VCC). The refrigerants are charged at the suction port of the rig. Once the compressor starts, it pumps up the refrigerant to the higher pressure. Oil Separator is provided to separates the oil that is probably carried along with refrigerants during the compression stroke. The outlet of the compressor has two thermocouples to measure the compressor top shell temperature and discharge temperature of the compressor From the oil separator the refrigerant passes to the shell and tube condenser, where in the cooling water supplied by the cooling tower at the ambient condition exchanges heat in the shell and tube frame work of the condenser. The refrigerant coming out of the condenser expected to be in the saturated state is made to flow in the sub cooler via liquid temperature controller where the liquid is further condensed to ensure the liquid state before it is expensed in the expansion valve. 2015, IERJ All Rights Reserved Page 2

The liquid (sub cooled) phase refrigerant passes on to the drier, to get wiped out of any moisture content present within. The receiver following next to the drier is just a storage unit where in it stores the refrigerant. Mass flow meter provided measures the amount of refrigerant that is been used by the compressor for particular given condition. Then the refrigerant is passed to the evaporator, where actually the cycle is theoretically believed as the starting point. The evaporator cabin (Sealed tank) as shown in fig.2 incorporates evaporator coil, stirrer and glycol heater. The glycol mixture is used as anti-freezing agent in the cabin to see to that the temperature does fall beyond the set value during the experimentation. There are 7 temperature sensors fixed in the circuit lines to measure the temperature condition of the refrigerant and the cooling water that runs in the system during cycle operation. The suction pressure and the discharge pressure of the compressor is been regulated by the pressure switch, the magnitudes of the same is measured by the transducer fixed at the inlet and outlet of the compressor. There are two more pressure transducer to sense the pressure in water supply lines to the condenser and sub cooler. A proportional-integral-derivative controller (PID controller) is a control loop feedback mechanism (controller) used in this system 3 in numbers that is been used to set the discharge pressure of the compressor, desired sub cooling temperature of the refrigerant and the suction temperature of the refrigerant before it enters the compressor.r134a,r407c are charged in the system one by one. for each condensing temperature, evaporating temperature is varied. Water cooled condenser specification: Cosmic Refrigeration: Sr Parts Name No. 1 Length of tube 2 Length of shell 3 Shell inner diameter 4 Shell outer diameter 5 Shell wall thickness 6 Number of tubes 7 Tube inner diameter 8 Tube outer diameter Specification 566mm 570mm 105mm 115mm 5mm 10No s 16mm 19.05mm Methodology: Analysis: 1.In a Test-Rig panel take a observation for temperature and pressure for using refrigerant R- 134a,R22,R404A,R407C(Hydrocarbon Blends). 2.Take readings for Compressor suction temperature, discharge temperature,suction pressure, Evaporator in pressure, Condenser in temp.,refrigerant mass flow rate, Glycol temp. 3.Using Refrigerant chart(p-h),refprop and cool-pack software for refrigerant R22,R134a,R404A,R407C obtain the values of enthalpies, density and viscosity. 4.Calucalation COP, Work done, and Refrigerant effect 5.Determination of Pressure drop, Mass flow rate, friction factor for different loads for R22,R134a,R404A,R407C. The pressure drop experienced by the shell-side fluid is calculated by; Where, Gs=Shell side mass velocity(m s /A s ) =Variable correction factor (µ /µ ) ᶲ s b w μ b= Is the viscosity of the shell-side fluid at. bulk temperature. μ w= is the viscosity of the tube-side fluid at wall temperature. Fs=Shell side friction factor (1) Re s= Shell side Reynolds No. =G s D e /µ 400<Re s = G s D e /µ<1*10 6 2015, IERJ All Rights Reserved Page 3

Reynolds number for the shell-side is based on the equivalent diameter and the velocity based on a reference flow: Shell Side Area(A s ): Re Equivalent diameter for Triangular layout: s ms De A s Ds As P T s P d B T o D etriangular 4A P flow Free Flow Area(A flow ): e 4 3P 4 T 2 d d 8 O 2 2 O A flow P 2 T 1 4 4 2 2 2 4 do PT do 6.Ploting of graphs: a)pressure drop Vs Mass flow rate b)friction factor Vs Mass flow rate c)temp. ratio Vs Mass flow rate d) Temp. ratio Vs Pressure drop. 7.Then Comparison for the performance by the results. 4 Results and Discussion : Present experiment was performed for various condensing temperatures ranging from 38.6 ᵒC to 45.6 ᵒC on the test apparatus shown in fig. 1. For each condensing temperature evaporating temperature was varied from 2 ᵒC to 10 ᵒC and corresponding readings of total pressure drop, mass flow rate and refrigerant temperature after sub-cooling were noted down. The values of the ΔPtot observed from the experiment were used to calculate frictional pressure drop, momentum pressure drop and friction factor for refrigerants R-134a, R-407C using equations (1). The graphs were plotted to check the trend of variation of pressure drop and friction factor with respect to the variation of mass flow rate. From calculations done it was observed that frictional pressure drop values were much higher than Total shell side pressure drop values. Hence the frictional pressure drop plays a vital role in design of condenser. Physical properties such as density, surface tension, kinematic viscosity and pressure have significant effect on shell side pressure drop. 1)Variation in different mass flow rate Vs Pressure drop for R134a: Fig.2 Variation in different mass flow rate Vs Pressure drop for R134a Fig. 2 shows variation of shell side pressure drop with respect to mass flow rate for R-134a refrigerant. It can be clearly observed that the pressure drop is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is increase in shell side pressure drop. 2)Variation in different mass flow rate Vs frictional factor for R134a: 2015, IERJ All Rights Reserved Page 4

Fig.3 Variation in different mass flow rate Vs frictional factor for R134a Fig. 3 shows variation of shell side friction factor with respect to mass flow rate for R-134a refrigerant. It can be clearly observed that the friction factor is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is decrease in mass flow rate. 3)Variation in different mass flow rate Vs Pressure drop for R407C: Fig.4 Variation in different mass flow rate Vs Pressure drop for R407C Fig. 4 shows variation of shell side pressure drop with respect to mass flow rate for R-407C refrigerant. It can be clearly observed that the pressure drop is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is increase in shell side pressure drop 4)Variation in different mass flow rate Vs frictional factor for R407C: Fig.5 Variation in different mass flow rate Vs frictional factor for R407C Fig. 5 shows variation of shell side friction factor with respect to mass flow rate for R-407C refrigerant. It can be clearly observed that the friction factor is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is decrease in mass flow rate. 5)Variation in different mass flow rate Vs Temp..Ratio(T d /T s ) for R407C. 2015, IERJ All Rights Reserved Page 5

Fig.6 Variation in different mass flow rate Vs Temp..Ratio(T d /T s ) for R407C. Fig. 6 shows variation of Temperatures with respect to mass flow rate for R-407C refrigerant. It can be clearly observed that the Temperature is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is decrease in Temperature. 6)Variation in different mass flow rate Vs Temp.Ratio(Td/Ts) for R134a: Fig.7 Variation in different mass flow rate Vs Temp.Ratio(Td/Ts) for R134a. Fig. 7 shows variation of Temperatures with respect to mass flow rate for R-134a refrigerant. It can be clearly observed that the Temperature is strongly affected by mass flow rate. As the flow velocity increases with increase in mass flow rate, there is decrease in Temperature. 7)Comparative analysis for variation of Temperature with mass flow rate. Fig.8 Comparative analysis for variation of Temperature with mass flow rate. Fig. 6 and fig. 7 a show the variation of Temperature with mass flow rate for R-134a and R-407C respectively. As the mass flow rate increases there is decrease in Temperature. The same trend is observed for all the refrigerants. This decrease is 0.2 % to 3.5 %, and 0.5 % to 1.8% with respect to mass flow rate for R-134a, and R-407C respectively 8) Comparative analysis for variation of shell side friction factor with mass flow rate. 2015, IERJ All Rights Reserved Page 6

Fig.6 Comparative analysis for variation of shell side friction factor with mass flow rate. Fig. 2 and fig. 5 a show the variation of friction factor with mass flow rate for R-134a and R-407C respectively. As the mass flow increases there is 0.2 % to 3.5 %, and 0.5 % to 1.8% decrease in friction factor. The same trend is observed for all the refrigerants. This decrease is with respect to mass flow rate for R-134a, and R-407C respectively. 9)Comparative analysis for variation of shell side pressure drop with mass flow rate Fig.10 Comparative analysis for variation of shell side pressure drop with mass flow rate. Fig.10shows the comparative frictional pressure drop analysis with respect to mass floe rate for all the three refrigerants. Only frictional pressure drop is considered for analysis as it accounts major part of total pressure drop. It can be seen that R-134a, R- 407C is the increasing order of frictional pressure drop with respect to mass flow rate. III. CONCLUSION Pressure drop and friction factor for refrigerants R-134a and R-407C were investigated across Condenser. Effect of mass flow rate on frictional pressure drop and friction factor was found out for each refrigerant and even comparative analysis is also done. Pressure drop is higher for higher mass flow rate where as friction factor is lowest for higher mass flow rate. And lower temperature where as higher mass flow rate.frictional pressure drop values play significant role for design purpose as it accounts major part of total pressure drop. The allowable pressure drop is 0.3-0.8 bar. Frictional pressure drop for R-407c is larger than R-134a. Friction factor R-134a is larger than R-407C s. but R-134a is not environment friendly refrigerant. Hence R-407c can be considered as best amongst these two refrigerants from the experiment performed. Friction factor correlation can also be developed from current data and can exist as future scope of the same experiment. IV. REFERENCES 1.R. Hosseini, A. Hosseini-Ghaffar and M. Soltan " April 2007 Experimental determination of shell side heat transfer coefficient and pressure drop for an oil cooler shell-and-tube heat exchanger with three different tube bundles", Applied thermal Engineering,Volume 27. 2.M.Serna and A.Jimenez, A compact formulation of the Bell Delaware method for Heat Exchanger design and optimization, Chemical Engineering Research and Design.83(A5): 539 550. 3.Ajit kumar M.S 1,Ganesha T 2,M.C.Math 3 vol.2,no7, CFD Analysis to study the effects of inclined Baffles on fluid flow in a shell and tube heat exchangers Dep. Of thermal power engineering VTU PG Centre,Mysore. 2015, IERJ All Rights Reserved Page 7

4.K Anand, Jan2014 Experimental Investigation of shell and tube heat exchanger using Bell Delaware method. Thermal power Engg. Dept.of Mech.Engg.PDACE Gulbarga vol-2 jan2014. 5. Saunders, 2008. Heat Exchangers, John Wiley & Sons, New York. Vol. 12. 6. S. Noie Baghban, M. Moghiman and E. Salehi, 1990 Thermal Analysis of shell side flow of shell and tube type heat exchanger using experimental and theoretical methods, Institute for Scientific Research, University of Guanajuato Lascurain de Retana No. 5 Guanajuato, Gto, México rence, and 36 pp. 256-262 7.C. Aprea, A. Greco, A. Rosato, Comparison of R407C and R417A heat transfer coefficients and pressure drops during flow boiling in a horizontal smooth tube, Energy Conversion and Management, 1629 1639. NOMENCLATURE P S =Shell side pressure drop.(p a ) F S =Shell side friction factor. N b =Number of baffles. ɸ s =Variable property correction F s= Shell side friction factor. ρ s =Shell side density(kg/m 3 ) μb=viscosity of the shell-side fluid at bulk temperature.(k) μw= viscosity of the tube-side fluid at wall temperature.(k) As= Shell Side Area(m) Aflow=Area of flow.(m) Pe=Equivalent Perimeter.(m) PT=Tube Pitch.(m) Ms=shell side mass flow rate(kg/m 2.s) T=Temperature (k) 2015, IERJ All Rights Reserved Page 8