GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Similar documents
GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GKS9 40" 90% Gas Furnaces

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMS9/GCS9 SERIES 93% AFUE

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

AMVM97 (B) / ACVM97 (B)

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

AVPTC. Air Handlers 1½ to 5 Tons

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

ComfortNet -Compatible

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

TECHNICAL INFORMATION MANUAL

Technical Information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

FG7T (C and L Series)

AVPTC Multi-Position, Internal Txv

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL INFORMATION MANUAL

AVPTC. Air Handler 1½ to 5 Tons

TECHNICAL SPECIFICATIONS

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

Wt. Lbs Model Number (BTUH) Hz

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Multi-Position Gas Furnaces

MULTI POSITION GAS FURNACE

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

MULTI POSITION GAS FURNACE

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Ruud Achiever Plus Series Multi-position Gas Furnaces

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Rheem Classic Series Multi-position Gas Furnaces

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Rheem Classic Plus Series Multi position Gas Furnaces

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

MERIT SERIES Downflow

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

13 GEP A L P - 1 A

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

Cooling Capacity CFM in. w.c. (125 Pa)

G6RC Series TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

TSTAT0101SC Recommended (order separately)

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

RG7D 1-Stage Heat Series

Upflow/Horizontal Condensing, Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

MBR. Multi-Position. Modular Blower

Cooling Capacity CFM range

TSTAT0201CW Recommended (sold separately)

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

T9MPV SmartComfort VS90 Product Specifications

Ruud Achiever Series Multi position Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

TECHNICAL MANUAL *MSS92, *CSS " SINGLE STAGE MULTI-SPEED GAS FURNACE UP TO 92% AFUE

RGE 13 A T - 1 A

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

Transcription:

/ Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10 Accessories...11 Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage gas valve Durable Silicon Nitride igniter Multi-speed blower motor Quiet single-speed induced draft blower Self-diagnostic control board All models comply with California 40 ng/j Low NOx emissions standard AHRI Certified; ETL Listed Cabinet Features Designed for multi-position installation : upflow, horizontal left or right : downflow, horizontal left or right Certified for direct vent (2-pipe) or on-direct vent (1-pipe) Easy-to-install top venting with optional side venting Convenient left or right connection for gas and electrical service Cabinet air leakage (QLeak) 2% Heavy-gauge steel cabinet with durable finish Foil-faced insulated heat exchanger cabinet Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS- www.goodmanmfg.com 8/15 Supersedes 4/15

Nomenclature G M S S 92 060 3 B N A A 1 2 3 4 5,6 7,8,9 10 11 12 13 14 Brand Minor Revision G Goodman Brand A - Initial Release B - 1st Revision Configuration M Upflow/Horizontal Major Revision C Downflow/Horizontal A - Initial Release B - 1st Revision Motor V Variable Speed ECM / ComfortNet NOx E Multi- Speed ECM N - Low NOx S Single Speed Cabinet Width Gas Valve B - 17.5" M Modulating C - 21" C Two Stage D - 24.5" S Single Stage Maximum CFM AFUE 2-800 CFM 92 92% AFUE 3-1200 CFM 96 96% AFUE 4-1600 CFM 97 97-98% AFUE 5-2000 CFM MBTU/h 040-40,000 BTU/h 080-80,000 BTU/h 120-120,000 BTU/h 060-60,000 BTU/h 100-100,000 BTU/h 2 www. goodmanmfg.com SS-

Product Specifications 0803BNA 0805CNA 1004CNA 1205DNA Heating Data High Fire Input¹ 40,000 60,000 80,000 80,000 80,000 100,000 100,000 120,000 High Fire Output¹ 36,840 55,260 73,680 73,680 73,680 92,100 92,100 110,520 AFUE² 92 92 92 92 92 92 92 92 Temperature Rise Range ( F) 30-60 35-65 35-65 35-65 25-55 35-65 35-65 35-65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 3" No. of Burners 2 3 4 4 4 5 5 6 Circulator Blower Available AC @ 0.5" ESP 1.5-3 1.5-3 1.5-3 3-5 3-5 3-5 3-5 3-5 Size (D x W) 10" x 8" 10" x 8" 10" x 8" 10" x 10" 11" x 10" 10" x 10" 11" x 10" 11" x 11" Horsepower @ 1075 RPM ⅓ ⅓ ⅓ ½ ¾ ½ ¾ ¾ Speed 4 4 4 4 4 4 4 4 Electrical Data Min. Circuit Ampacity⁴ 9.6 9.6 9.6 11.7 13.7 11.7 13.7 13.7 Max. Overcurrent Device (amps)⁵ 15 15 15 15 15 15 15 15 Shipping Weight (lbs) 109 112 115 137 138 139 140 152 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. ⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- www.goodmanmfg.com 3

Product Specifications Heating Data High Fire Input¹ 40,000 60,000 80,000 100,000 High Fire Output¹ 36,840 55,260 73,680 92,100 AFUE² 92 92 92 92 Temperature Rise Range ( F) 30-60 35-65 35-65 35-65 Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" No. of Burners 2 3 4 5 Circulator Blower Available AC @ 0.5" ESP 1.5-3 1.5-3 2.5-4 2.5-4 Size (D x W) 10" x 8" 10" x 8" 10" x 10" 11" x 10" Horsepower @ 1075 RPM ⅓ ⅓ ½ ¾ Speed 4 4 4 4 Electrical Data Min. Circuit Ampacity⁴ 9.6 9.6 11.7 13.7 Max. Overcurrent Device (amps)⁵ 15 15 15 15 Shipping Weight (lbs) 109 112 137 140 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. ⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. 4 www. goodmanmfg.com SS-

Dimensions Air Discharge Air Discharge 28¾ Air Intake 2" Pipe Left-Side Drain Trap Exterior Holes 6½ 2¾ 2⅝ 2 Center Dimple For Alternate Air Intake Pipe 3" OD Hole High-Voltage Standard Gas Supply Location A Dim B Discharge C 1⅞ ¾ ¾ 2 Vent/ Flue Pipe 2" PVC Right-Side Drain Trap Exterior Holes High-Voltage Alternate Gas Supply 6½ 19½ Alternate Vent/ Flue Location ¾ 34½ 14 1½ Side Cut-out 5 9¼ 19⅝ 23 24⅞ 31⅞ 26½ 23 21⅛ 19⅝ 9¼ 5 Side Cut-Out 1⅜ LEFT SIDE VIEW Low-voltage 23 1⅞ 2⅜ 2½ Condensate Drain Trap Exterior Connection (Right or Left Side) ¾ PVC FRONT VIEW D Folded Flanges E Unfolded Flanges ⅞ Low-Voltage 1⅞ 2⅜ 2½ RIGHT SIDE VIEW 22 Folded Flanges 23½ Unfolded Flanges Model A B C D E 17½ 16" 13⅞" 12⅛" 13⅝" 17½ 16" 13⅞" 12⅛" 13⅝" 0803BNA 17½ 16" 13⅞" 12⅛" 13⅝" 21" 19½" 17⅜" 16" 17½" 0805CNA 21" 19½" 17⅜" 16" 17½" 1004CNA 21" 19½" 17⅜" 16" 17½" 21" 19½" 17⅜" 16" 17½" 1205DNA 24½" 23" 20⅞" 19⅜" 20⅞" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 3" C 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. SS- www.goodmanmfg.com 5

Dimensions A 6½ 1⅜ 23 2⅝ 1⅞ C 1⅝ 2½ 1⅞ Alternate Vent/ 1½ Low-Voltage 14 Side Cut-Out Low-Voltage Alternate Gas High-Voltage 34½ 25⅛ Alternate Gas Supply Side Cut-Out 14¾ 25⅛ 14⅞ 14¾ 4⅛ 6⅞ 11⅜ 11⅜ 6⅞ Drain Trap Holes Standard Drain Trap 28¾ Air Discharge 2 2½ 3½ D Folded Flanges E Unfolded Flanges Front View High-Voltage 2 2⅝ Right Side Exterior Drain Trap Holes 18⅛ Folded Flanges 20⅛ Unfolded Flangs Right-Side View Air Discharge Model A B C D E 17½" 14⅝" 14" 14½" 16" 17½" 14⅝" 14" 14½" 16" 21" 18⅛" 17½" 18" 19½" 21" 18⅛" 17½" 18" 19½" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 3" NC 0" 1" Horizontal 6" 0" 3" C 0" 6" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. 6 www. goodmanmfg.com SS-

Airflow Data Model 0803BNA 0805CNA 1004CNA 1205DNA ¹ at 0.5" ESP Motor Speed Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,498 N/A 1,446 N/A 1,368 N/A 1,302 N/A 1,227 N/A 1,145 1,059 954 Med 2.5 1,223 N/A 1,182 N/A 1,153 30 1,099 31 1,051 32 982 901 813 Med-Lo 2 983 35 971 35 945 36 919 37 878 39 813 746 659 Low 1.5 816 42 794 43 758 45 734 46 678 50 637 597 523 High 3 1,494 N/A 1,428 36 1,362 38 1,294 39 1,231 42 1,162 1,076 972 Med 2.5 1,203 42 1,178 43 1,147 45 1,101 46 1,045 49 986 927 831 Med-Lo 2 977 52 965 53 939 54 904 57 866 59 801 763 639 Low 1.5 801 64 786 65 751 N/A 714 N/A 714 N/A 680 635 596 High 3 1,459 47 1,397 49 1,339 51 1,270 54 1,202 57 1,107 1,049 952 Med 2.5 1,191 57 1,166 58 1,137 60 1,086 63 1,033 N/A 973 889 797 Med-Lo 2 985 N/A 967 N/A 932 N/A 900 N/A 859 N/A 805 731 620 Low 1.5 808 N/A 785 N/A 758 N/A 726 N/A 679 N/A 629 590 513 High 5 2,115 N/A 2,050 N/A 1,973 35 1,915 36 1,810 38 1,695 1,587 1,467 Med 4 1,802 38 1,739 39 1,725 40 1,665 41 1,612 42 1,532 1,443 1,320 Med-Lo 3.5 1,517 45 1,509 45 1,496 46 1,475 46 1,441 47 1,388 1,304 1,205 Low 3 1,213 56 1,225 56 1,216 56 1,194 57 1,179 58 1,135 1,084 1,005 High 5 2,284 30 2,231 31 2,170 31 2,103 32 2,037 33 1,945 1,836 1,750 Med 4 1,865 37 1,869 36 1,775 38 1,732 39 1,684 40 1,619 1,548 1,480 Med-Lo 3.5 1,594 43 1,571 43 1,530 45 1,492 46 1,454 47 1,414 1,355 1,293 Low 3 1,411 48 1,366 50 1,325 51 1,296 53 1,251 54 1,200 1,147 1,096 High 5 2,082 41 1,997 43 1,943 44 1,847 46 1,749 49 1,669 1,560 1,443 Med 4 1,823 47 1,782 48 1,711 50 1,659 51 1,574 54 1,513 1,402 1,305 Med-Lo 3.5 1,565 54 1,545 55 1,529 56 1,487 57 1,441 59 1,365 1,287 1,196 Low 3 1,261 N/A 1237 N/A 1,242 N/A 1,216 N/A 1,179 N/A 1,145 1,098 1,034 High 5 2,137 40 2,073 41 2,031 42 1,949 44 1,879 45 1,811 1,734 1,625 Med 4 1,793 48 1,754 49 1,704 50 1,648 52 1,590 54 1,534 1,451 1,371 Med-Lo 3.5 1,558 55 1,518 56 1,477 58 1,425 60 1,376 62 1,316 1,242 1,170 Low 3 1,370 62 1,325 64 1,288 N/A 1,237 N/A 1,191 N/A 1,134 1,086 1,024 High 5 2,256 45 2,192 47 2,133 48 2,054 50 1,986 51 1,907 1,834 1,718 Med 4 1,805 57 1,762 58 1,722 59 1,677 61 1,618 63 1,563 1,507 1,441 Med-Lo 3.5 1,565 65 1,513 N/A 1,480 N/A 1,415 N/A 1,392 N/A 1,346 1,269 1,198 Low 3 1,368 N/A 1,326 N/A 1,278 N/A 1,238 N/A 1,208 N/A 1,165 1,093 1,052 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. Minimum Filter Sizes 0803BNA 0805CNA 1004CNA 1205DNA Filter Size (in²) (Qty) (1) 16 x 25 (side or bottom) (1) 20 x 25 (bottom) or (2) 16 x 25 (side) (1) 16 x 25 (side or bottom) (1) 20 x 25 (bottom) or (2) 16 x 25 (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS- www.goodmanmfg.com 7

Airflow Data Model 0804BNA ¹ at 0.5" ESP Motor Speed Tons AC¹ (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM High 3 1,400 N/A 1,331 N/A 1,263 N/A 1,189 N/A 1,106 31 1,020 941 843 Med 2.5 1,204 N/A 1,176 N/A 1,121 30 1,072 32 1,002 34 927 853 740 Med-Lo 2 1,020 33 998 34 968 35 923 37 880 39 820 739 652 Low 1.5 841 41 827 41 797 43 766 44 727 47 680 634 556 High 3 1,668 31 1,335 38 1,288 40 1,207 42 1,133 45 1,061 955 845 Med 2.5 1,224 42 1,182 43 1,139 45 1,088 47 1,015 50 948 859 759 Med-Lo 2 1,030 50 1,005 51 988 52 942 54 893 57 830 751 666 Low 1.5 859 60 830 62 815 63 789 65 751 N/A 693 629 556 High 4 1,770 39 1,645 41 1,610 42 1,528 45 1,437 47 1,340 1,251 1,141 Med 3.5 1,690 40 1,615 42 1,531 45 1,470 46 1,393 49 1,308 1,196 1,099 Med-Lo 3 1,612 42 1,540 44 1,472 46 1,398 49 1,306 52 1,223 1,132 1,010 Low 2.5 1,396 49 1,339 51 1,304 52 1,250 55 1,170 58 1,092 1,010 906 High 4 1,793 48 1,699 50 1,610 53 1,533 56 1,461 58 1,363 1,247 1,146 Med 3.5 1,693 50 1,622 53 1,552 55 1,467 58 1,390 61 1,320 1,205 1,083 Med-Lo 3 1,632 52 1,546 55 1,493 57 1,415 60 1,332 64 1,257 1,148 1,054 Low 2.5 1,429 60 1,380 62 1,334 64 1,258 N/A 1,199 N/A 1,136 1,041 942 Notes CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of maximum static pressure allowed when heating. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. Minimum Filter Sizes Filter Size (in²) (Qty) (2) 10 x 20 or (1) 16 x 25 (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) 8 www. goodmanmfg.com SS-

Temperature Rise Range Chart 100 90 80 70 60 50 40 30 20 10 BTU BTU OUTPUT Output vs Vs. TEMPERATURE Temperature Rise RISE Chart CHART 600 CFM 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM Formulas FMULAS BTU BTU/h OUTPUT Output = CFM x x 1.08 1.08 x Rise x RISE BTU OUTPUT RISE = BTU/H Output Rise = CFM 1.08 CFM x 1.08 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT Output BTU/h BTU/HR x 1,000 x 1000 TEMPERATURE Temperature Rise RISE SS- www.goodmanmfg.com 9

Wiring Diagram 24V THERMOSTAT CONNECTIONS GND BR BR RD C G R W DIAGNOSTIC LED 2 CIRCUIT CONNECT HOT SURFACE IGNITER COL CODES: YL YELLOW ANGE PU PURPLE GN GREEN BLACK 24 VAC 115 VAC 115 VAC HOT AND PARK TERMINALS COOL-H CAPACIT GND ID BLOWER PRESSURE SWITCH HEAT-H BLOWER COMPARTMENT BURNER COMPARTMENT N O 24 VAC HUMIDIFIER FUSE (HI) BL (MED) (MED LOW) RD (LOW) CIRCULAT BLOWER AUTO RESET PRIMARY LIMIT CO NTR O L C2 GAS VALVE YL PK PINK BR BROWN ITE BL BLUE GY GRAY RD RED LINE-H RD 1 PK INDUCED DRAFT BLOWER C Y INTEGRATED CONTROL MODULE 24 VAC HUMIDIFIER GY PK AUXILIARY LIMIT CONTROLS BL PU MANUAL RESET ROLLOUT LIMIT CONTROL(S) ( SINGLE CONTROL ON 40K BTU ) GND RD GR BLOWER COMPARTMENT DO SWITCH (OPEN EN DO OPEN) BL 24V THERMOSTAT CONNECTIONS PK 115 VAC NEUTRAL TERMINALS XFMR-H 40 VA TRANSFMER 3 2 2 RD 1 6 5 4 9 8 7 12 11 10 GY PK BL GR YL INTEGRATED CONTROL MODULE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION EQUIPMENT GND FIELD GND IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPAT ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTUR'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CRECT HEATING TEMPERATURE RISE AND THE CRECT COOLING CFM. 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFM TO N.E.C. AND LOCAL CODES. TH (3) XFMR-H LINE-H DO SWITCH WARNING: DISCONNECT POWER BEFE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. JUNCTION BOX GR GND FLAME SENS FS IGN IND TR (6) GND (8) MVC (9) HLO (1) RO2 (11) RO1 (5) COOL HEAT-H JUNCTION BOX L GND N INTEGRATED CONTROL MODULE DISCONNECT TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WARNING:DISCONNECT POWER BEFE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. DISCONNECT AUXILIARY LIMIT CONTROLS FLAME SENS HOT SURFACE IGNITER ID BLWR GND PS (10) C NO PSO (4) HLI (7) MANUAL RESET ROLLOUT LIMIT CONTROL(S) (SINGLE CONTROL ON 40K BTU) 24 VAC 115 VAC CIRCULAT BLWR 40 VA TRANSFMER N GND L FIELD SPLICE SWITCH (TEMP.) AUTO RESET PRIMARY LIMIT CONTROL INTEGRATED CONTROL MODULE GR RD YL BL STEADY ON = NMAL OPERATION OFF = CONTROL FAILURE 1 FLASH = 2 FLASHES = PRESSURE SWITCH STUCK CLOSED 3 FLASHES = PRESSURE SWITCH STUCK OPEN 4 FLASHES = OPEN HIGH LIMIT 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE 6 FLASHES = 7 FLASHES = 7 FLASHES = LOW FLAME SIGNAL 8 FLASHES = 8 FLASHES = CHECK IGNITER IMPROPER GROUNDING CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY SYSTEM LOCKOUT (RETRIES EXCEEDED) OPEN ROLLOUT GY BR MI GY YL NO C PU BR BL GY BR FRONT COVER PRESSURE SWITCH C G Y W R TO MICRO EAC-H MV(12) HUMIDIFIER N O FRONT COVER PRESSURE SWITCH ELECTRONIC AIR CLEANER C C2 GAS VALVE M1 ID BLOWER PRESSURE SWITCH LINE NEUTRALS TO 115 VAC / 1Ø / 60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 0140F01908-A 10 www. goodmanmfg.com SS-

Accessories Model Description 0803BNA 0805CNA 1004CNA 1205DNA CVENT-2 Concentric Vent Kit (2") --- CVENT-3 Concentric Vent Kit (3") CFSB17 Downflow Sub-Base 17.5" --- --- --- --- --- --- --- --- CFSB21 Downflow Sub-Base 21" --- --- --- --- --- --- --- --- CFSB24 Downflow Sub-Base 24" --- --- --- --- --- --- --- --- RF000142 Drain Kit -Horizontal Left Vertical Flue EFR02 External Filter Rack with 16"x25" Permanent Filter --- --- --- 0170K00000S Flush Mount Vent Kit - 3" or 2" 0170K00001S Flush Mount Vent Kit - 2" --- AFE18-60A Fossil Fuel (Dual Fuel) Kit HASFK High-Altitude Natural Gas Kit HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit HASFK-4 HASFK-4 HASFK-5 HASFK-4 HASFK-4 HASFK-4 HASFK-5 HASFK-4 LPLP03 Low LP Gas Pressure Switch LPM-07 LP Conversion Kits FTK04 Twinning Kit Model Description CVENT-2 Concentric Vent Kit (2") CVENT-3 Concentric Vent Kit (3") CFSB17 Downflow Sub-Base 17.5" --- --- CFSB21 Downflow Sub-Base 21" --- --- CFSB24 Downflow Sub-Base 24" --- --- --- --- RF000142 Drain Kit -Horizontal Left Vertical Flue --- --- --- --- EFR02 External Filter Rack with 16"x25" Permanent Filter --- 0170K00000S Flush Mount Vent Kit - 3" or 2" 0170K00001S Flush Mount Vent Kit - 2" AFE18-60A Fossil Fuel (Dual Fuel) Kit HASFK High-Altitude Natural Gas Kit HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit HASFK-4 HASFK-4 HASFK-5 HASFK-4 LPLP03 Low LP Gas Pressure Switch LPM-07 LP Conversion Kits FTK04 Twinning Kit SS- www.goodmanmfg.com 11

Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2015 Goodman Manufacturing Company, L.P. Houston, Texas 12 www. goodmanmfg.com SS-