USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Industrial Flanged Immersion Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Flanged Immersion Heaters

Flanged Immersion Heaters

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation Instructions Type XPMC Air Heater for Hazardous Locations

ULTRA-SAFE Explosion-proof Duct Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation, Operation and. Maintenance Instructions

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INFINITY FLUIDS CORPORATION

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

SuperKlean Washdown Products

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

ULTRA-SAFE Explosion-proof Duct Heaters

CPL Series Pedestal Convection Heater

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

LTFX Electric Tank Immersion Heaters Installation Instructions

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Tubular Industrial Process

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Installation & Maintenance Instructions

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

R Series B & T2 Model

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Electrical Preventive Maintenance (EPM) Program

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

WATLOW ELECTRIC MANUFACTURING COMPANY Installation & Maintenance Manual for ECO-HEAT Heaters I&M MANUAL No: Page: 1 Date: 3/15/2017 Rev: 4

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

CXH-A Forced-Air Heater

ELECTRICAL SAFETY Information Bulletin

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

Differences Among Screw Plug Immersion Heaters

Installation of Glass Lined Equipment

WATLOW ELECTRIC MANUFACTURING COMPANY

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

24 VAC SYSTEM CONTROL KIT

24 VAC SYSTEM CONTROL KIT

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Explosion Protected Panelboards D2Z Series

FX5 Series Explosion-Proof Electric Air Heaters

FLCH4R Garage and Utility Electric Heater

Getting Started Quick Reference Guide

VERTICAL HIGH OUTPUT VHC-IOM INSTALLATION AND MAINTENANCE INSTRUCTIONS VHC INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE TECHNICIAN

Brasch Hazardous Location Unit Heaters

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Installation & Maintenance Instructions

ELECTRICAL SAFETY Information Bulletin

Installation Instructions U-RAD-LT Electric Radiant Heaters

Installation Instructions

Installation Instructions

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

ELECTRICAL SAFETY Information Bulletin

Installation Instructions

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Instruction Manual HWR MODEL RESISTO-FLO ELECTRIC BOILER

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Survey of electrical equipment installed in hazardous areas on tankers

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

SECTION ISOLATED POWER SYSTEMS

WATLOW ELECTRIC MANUFACTURING COMPANY

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Transcription:

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS APPLICATION INDEECO Explosion proof Electric Immersion Heaters for Hazardous Locations are ccsaus Certified for use in areas (external to the mounting flange) that are classified as Class I, Divisions 1 & 2, Groups B and/or C & D. Heaters marked exclusively for a Division 2 area are constructed without arcing and sparking components. The maximum operating temperature ignition code is determined for the operating and mounting requirements of each specific application and is assigned at the time of manufacture. See the data plate for the specific temperature code and mounting orientation assigned to this heater. NEVER operate the heater in an atmosphere with an ignition code temperature lower than the heater marking. NEVER operate the heater mounted in an orientation contrary to its marking. The maximum external temperature code only applies to external surfaces of the explosion proof electric immersion heater. The temperature code does not apply to internal components of the heater such as the heating elements or to any parts of the tank or pipe line that the heater is mounted in. The rating of the process, gas or liquid, and the process containing tank or pipeline in which the active portion of the heating elements are located in are to be classified as non hazardous. The explosion proof electric immersion heater terminal enclosure is rated for a minimum operating ambient temperature of 40 C ( 40 F) and a maximum operating ambient temperature of 40 C (104 F), unless otherwise stamped on the data plate. For details on the particular hazardous environments having the potential for explosion, refer to Articles 500 through 516 of the National Electrical Code or Section 18 of the Canadian Electrical Code, Part I. A. The INDEECO Explosion proof Electric Immersion Heaters are intended to be mounted into a tank or in a pipe line by a mounting flange that mates to the heater mounting flange. The active portion of the heating elements extend into the tank or pipe line to heat the contained gas or liquid. The unheated portion of the elements extend back through the mounting flange and any reflector shield(s) to enter the terminal enclosure. Operation of the heater requires a remotely mounted, properly coordinated electrical power control panel that contains all of the necessary operation and safety controls. The element joints at the mounting flange and terminal enclosure are welded or silver soldered pressure tight joints. A safety high temperature sensing thermocouple is attached to the external surface of the mounting flange. Other safety high temperature sensing thermocouples may be attached to the active portion of the heating element sheath or located to sense the process temperature. These safety temperature sensing thermocouples should be electrically connected per the wiring diagram to the heater electrical power controls so that the heater power is shut off if excessive temperatures are reached. The heaters are specifically designed for each application and should give years of safe, trouble free operation when properly installed, operated and maintained. B. Disassembly of the unit for installation is not required or authorized. When installing: 1. Observe all heater nameplate ratings, warnings and notes. 2. Follow the wiring diagram in making all electrical connections. 3. Keep all electrical connections tight. 4. Keep the heater terminal enclosure and element area clean. 5. Carefully read and comply with all warnings and cautions. All of the CAUTIONS and WARNINGS are stated in the following Safety Summary and are repeated throughout these instructions. CAUTION: INDEECO strongly recommends this heater be installed by qualified personnel familiar with the National Electrical Code and/or the Canadian Electrical Code requirements for hazardous locations as well as any local codes. It is the responsibility of the installer to verify the safety and suitability of the installation. Page 1 of 5 425 Hanley Industrial Court * St. Louis, MO 63144

CAUTION: NEVER operate the heater in an atmosphere with an ignition temperature lower than the heater marking. The heater must be mounted, vertical or horizontal, as marked on the data plate to Disassembly of the unit, for installation, is not required or authorized. The heater is intended to be electrically connected to a coordinated heater control panel that contains the necessary flange safety high temperature limit control. The flange safety high limit control should not be set higher than the limit control setting shown on the data plate. CAUTION: When connecting the safety high temperature limit sensors, be sure to follow the wiring diagram provided with the heater. The heater must not be operated without the safety high temperature limit cutout(s) properly connected in the circuit. Never operate the heater with the flange safety high temperature limit control set above the nameplate limit setting. Replacement of electrical components should only be done by authorized personnel familiar with the requirements of maintaining electrical equipment in an explosion hazard area. Replacement of electrical components must be obtained from the factory to maintain the hazardous location rating. disconnect switch in the off position and tag the circuit Out for Maintenance before working on this equipment. INSTALLATION Site Selection: 1. The INDEECO Explosion proof Electric Immersion Heaters for Hazardous Locations are designed for use only while permanently mounted in a tank or pipe line in a vertical or horizontal orientation as stamped on the data plate. 2. The site must allow sufficient free space around the heater for safe and easy installation and maintenance access. a.) The minimum pull space allowed should be at least equal to the heaters overall length plus 3 feet. b.) Workspace for heater maintenance should be at least 3 feet all around the mounting flange and terminal box. 3. The elements extending out from the external surface of the mounting flange should not be enclosed or insulated in any manner that would prevent air circulation around the face of the flange and elements. Likewise the terminal enclosure should not be enclosed or insulated. CAUTION: INDEECO strongly recommends this heater be installed by qualified personnel familiar with the National Electrical Code and/or the Canadian Electrical Code requirements for hazardous locations as well as any local codes. It is the responsibility of the installer to verify the safety and suitability of the installation. The heater must be mounted, vertical or horizontal, as marked on the data plate to Page 2 of 5 425 Hanley Industrial Court * St. Louis, MO 63144

Mechanical Installation: Once an acceptable location has been determined, follow these instructions to complete the mechanical installation. CAUTION: Disassembly of the unit for Installation is not required or authorized 1. Lifting eyes are provided to facilitate handling. Do not lift the heater by the heating elements. 2. Do not nick or scratch the mating surfaces of the mounting flanges. 3. Exercise care when installing the heater so as not to damage the heating elements, spacers, or temperature sensors. 4. Be sure a gasket rated for the application is installed between the sealing surfaces of the mounting flanges. 5. Be sure all flange bolts are installed and securely tightened. 6. Be sure the element bundle is adequately supported to prevent drooping. For element bundles 30" or less in length, supports are not necessary. For longer element bundles, supports are recommended within 6" from the U bend end of the bundle and on maximum 24" centers thereafter. Supports should allow for thermal expansion of the element bundle. 7. Pressure test the installation to make sure there are no leaks at any of the joints. 8. Insure the tank or pipe line is full, and/or the process flow rate is present before operating the heater. Electrical Installation Follow these instructions to complete the electrical installation. CAUTION: The heater is intended to be electrically connected to a coordinated heater control panel that contains the necessary flange safety high temperature limit controls. When connecting the safety high temperature limit sensor(s), be sure to follow the wiring diagram provided with the heater. The heater must not be operated without the safety high temperature limit cutout(s) properly connected in the circuit. 1. Remote, coordinated heater control is required. Follow the wiring diagram and any Code recommendations in making all electrical connections. 2. Use only an approved explosion proof means of wiring, such as mineral insulated cable or copper conductors in rigid conduit with threaded connections and conduit seals per the CEC or NEC requirements to make electrical connections to the heater. 3. Follow the NEC and/or CEC and any local electrical and building codes related to the installation and intended use of the heater in an explosion hazard area. 4. When doing any work on a heater, including the initial electrical connection, disconnect the electrical current at the main branch circuit switch, and lock the switch in the off (open) position and tag the circuit Out for Maintenance to prevent potential lethal shock hazards. 5. Confirm that the electrical power supply matches the nameplate voltage, phase and amperage rating of the heater to be connected. 6. Ensure conductors are of appropriate gauge size. Size all input conductors according to accepted standards consistent with the temperature rating of the wire being used. Use minimum 75 C rated wire or as otherwise indicated on the heater nameplate. 7. All thermocouple extension wire must be sized by the length of the run to stay below the maximum lead resistance specified in the control manufacturers instructions. The extension wire (pair) resistance should be kept at a value that will limit the offset error to 1 F or less. 8. Do not run thermocouple extension wire in the same conduit with AC electrical conductors. 9. Proper installation of the heater requires that an adequate grounding conductor be connected to the ground terminal. This terminal is painted green or marked with the letter G and is located on the inside of the control enclosure next to the power input terminals. An external grounding pad may also be provided on the terminal enclosure. 10. Refer to the wiring diagram to ensure that all connections are as required. 11. Check and confirm all connections are securely fastened. 12. Ensure that input conductors and conduit have adequate strain relief at installation. 13. Before application of electrical power, recheck all connections to ensure compliance with the wiring diagram and any code requirements. Remove any foreign objects from the terminal enclosure. Reinstall cover tightly. 14. See operating instructions before energizing the heater. disconnect switch in the off position and tag the circuit out for maintenance before working on this equipment. Page 3 of 5 425 Hanley Industrial Court * St. Louis, MO 63144

CAUTION: The heater is intended to be electrically connected to and controlled by a coordinated heater control panel that contains the necessary flange safety high temperature limit control(s). When connecting the safety high temperature limit sensor(s), be sure to follow the wiring diagram provided with the heater. The heater must not be operated without the safety high temperature limit cutout(s) properly connected in the circuit FIELD INSTALLED CONTROLS temperature sensors. The output of the safety high temperature limit controls must be electrically connected to the heater power control(s) so as to shut the heater off if the flange high limit control, or other safety high temperature control outputs are actuated. 2. Use Dwyer, Love Series 16L or other equivalent (QUYX/QUYX7) or FM approved device that has been evaluated for use as a temperature limit control for heating applications. 3. Contact the factory for coordination of any field installed controls. Field installed controls not shown on the wiring diagram may void the INDEECO warranty and the agency certification. 1. If the heater control panel is not supplied by INDEECO the control supplier must include an approved thermocouple input temperature control for the flange safety high temperature sensor as well as other controls for heating element sheath and/or process safety high CAUTION: The flange safety high limit control should not be set higher than the limit control setting shown on the data plate. OPERATION The INDEECO Explosion proof Electric Immersion Heaters may be operated normally at ambient temperatures of 104 F (40 C) or less, unless otherwise marked, and in atmospheres containing less than 21% oxygen by volume, and as classified on the nameplate. All of these conditions must be met before attempting to operate the heater. The heater should never be operated in an oxygen enriched atmosphere or at ambient temperatures above the marked maximum ambient temperature or 104 F, (40 C). At higher ambient conditions the safety high temperature limit cutouts may activate. If this occurs, the installation should include some means to de energize the heater during high ambient conditions, such as an automatic temperature control thermostat or a manually operated disconnect switch, to prevent excessive cycling of the controls. CAUTION: NEVER operate the heater in an atmosphere with an ignition temperature lower than the heater marking. CAUTION: The heater must be mounted, vertical or horizontal, as marked on the data plate to Never operate the heater with the flange safety high temperature limit control set above the nameplate limit setting. Initial Operation: Check to make sure the mechanical and electrical installation is complete and that it is safe to operate the heater. Normal Operation 1. Inspect the heater installation for loose bolts, covers, signs of overheating or corrosion that could impair the ability of the heater to operate safely. 2. Perform the operation steps per the instructions provided with the remote heater control panel. 3. Place the heater in service. Page 4 of 5 425 Hanley Industrial Court * St. Louis, MO 63144

MAINTENANCE disconnect switch in the off position and tag the circuit out for maintenance before working on this equipment. CAUTION: Replacement of electrical components should only be done by authorized personnel familiar with the requirements of maintaining electrical equipment in an explosion hazard area. Replacement of electrical components should be obtained from INDEECO to maintain the hazardous location rating. Electrical: 1. Annually inspect all terminal connections and visible insulation for damage, looseness, fraying, etc., as applicable. Tighten any loose terminals and replace or repair damaged or deteriorated insulation. 2. If reduced heat output is suspected verify the condition of the heating elements by using an ammeter to check the current draw of each input line. All input lines should draw approximately equal current which should agree with nameplate rating. If they do not, one or more of the heating elements could be burned out. Mechanical: 1. Check the terminal enclosure, and conduit connections for evidence of water leaks or moisture collection. Tighten connections and check the cover O ring as required. 2. The Division 1 marked explosion proof control box is designed with threaded joints and metal to metal contact at the cover joint to prevent an explosion. Do not attempt to install gasket material of any type at these joints. 3. Annually check the tightness of all mounting bolts and nuts. 4. Should there be any evidence of fluid or gas leakage from the mounting flange, or element joints the heater should be repaired immediately. Contact the factory for instructions. REFERENCE DATA Wiring Diagrams: Please refer to the enclosed wiring diagrams in making all electrical connections to the heater and in performing any required maintenance. Data Plate Information: The data plate contains the catalog number and rating information. Please copy this information down and have it available when communicating with the factory. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. Page 5 of 5 425 Hanley Industrial Court * St. Louis, MO 63144