AV60 Advocate Lavatory System AV-Series

Similar documents
AV60 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

AV90 Advocate Lavatory System AV-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

FL-2H, FL-2L Frequency Lavatory System FL-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

Express Lavatory System SS-Series

SS-3N Express Lavatory System SS-Series

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

LD-5010 OmniDeck with WashBar 5000 Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

FL-3H, FL-3L Frequency Lavatory System FL-Series

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

Express Lavatory System MG-Series

Express Lavatory System MG-Series

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

LVQD3 Verge with WashBar Technology LVQ-Series

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

LVQD3 Verge with WashBar Technology LVQ-Series

LVQD1 Verge with WashBar Technology LVQ-Series

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Model Z Sundara Reef Triple Basin Hand Washing System

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

School Solutions Ideabook

LVSD2 Verge Wash Basin LVS-Series

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

LVSD2 Verge Wash Basin LVS-Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation Instructions OBSOLETE

MERIDIAN MODEL# 3793

Model Z Sundara Float Double Basin Hand Washing System

Washfountain Application Guide

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

PAT BASIN MODEL 9121, 9131, & 9141

LA60 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

A. Section Joint Sealants: Seal fixtures to walls and floors.

LA45 DISCONTINUED IMPORTANT!

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

LA90 DISCONTINUED IMPORTANT!

Terreon Lav Decks WARNING

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

ADA guidelines. 48" min. 30" min. 8 min. 34 max. to top of lavatory rim. 27 min. knee space to bottom of bowl

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Partitions. Accessories. Lockers. No-Touch Washroom Accessories

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

HOT WATER WITH THE SNAP OF A FINGER. Mini Tanks. Basic Heaters. High Capacity Heaters. Model CMT. Model SR, M & E. Model ER Series

Luckdrops. Technical Spec Sheet. Studio+ Modular Home

Durability within reach

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Unit Size (HxWxD) x 11.6 x 3.9 / 339 x 295 x 100

Commercial washroom innovation. 90 years as the leading source of innovative solutions for all washroom design challenges. bradleycorp.

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Transcription:

Soap, water and hand dryer, unique all-in-one patent pending design Includes infrared, high speed, dual-sided hand dryer at each hand washing station Includes large capacity, top-fill, infrared soap dispenser, with low level indicator and one-of-a-kind overfill protection Includes hygienic hands-free infrared,.38gpm faucet Constructed of Terreon Solid Surface Material Meets International Codes & Standards Specifications The Advocate Lav System s unique all-in-one design allows users to access soap, water and a hand dryer without leaving the hand washing station. This provides personal space and helps to prevent water from dripping off hands and on to the floor, making cleaning and maintenance easier while providing a safer restroom environment. The AV-Series features a solid surface one-of-a-kind integral bowl. This system can be mounted at different heights to accommodate hand washing for adults, children, young children and those with disabilities. Construction owl Constructed of Terreon, a densified solid surface material composed of polyester resin or Terreon RE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are certified by NAH to meet ANSI Z124.3, Z124.6 and ANSI/ICPA SS-1-2001. Terreon and TerreonRE are GREENGUARD certified as low-emitting materials. Trap Cover Enclosure The trap cover of the Advocate lav system not only conceals plumbing and electrical connections, but also reduces time needed for installation and maintenance. Trap cover is made from Class A fire-rated polystyrene. Trap cover color: Coal. End Panel The end panels are deep drawn 18 gauge stainless steel. Stainless steel is polished 300 series with a #3 finish. End panels have internal stud welds for mounting to stainless steel frame described below. Mounting Frame The AV-Series includes welded 18 gauge stainless steel mounting frame with 14 gauge basin supports, eliminating the need for additional specifications and/or casework to support the fixture. All Advocate Lavatory Systems meet or exceed industry standards for load testing. Faucet The faucet sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Range is 4". This creates a specific detection area near the faucet spout. Sensor activates when the user s hands enter the detection area. A timing turn-off delay of 2 3 seconds results in a smooth, controlled hand-washing operation. The radley sensor is not affected by varying skin tones or darkness. Sunlight or bright washroom lights (up to 10,000 lux) will not activate the system. The flow is a spray pattern at a rate of.38 gpm. Low Voltage Transformer A Class II, UL/CSA-listed 120/24 VAC or 230/24 VAC, plug-in transformer powers the solenoid valve. The transformer, furnished as standard equipment, plugs into a standard GFCI protected electrical outlet. Protected by one or more of the following patents: D663, 016; S674,967. Other patents pending. Page 1 of 8 This information is subject to change without notice. Model AV60 Valve 24V, 50/60 Hz, 3 8" NPT electronically-activated solenoid valve provides reliable performance since there are few moving parts, and its operation is unaffected by most chemicals and minerals often present in municipal water supplies. Operating water pressure range is 40 100 psi. Flow regulator keeps flow rate constant at all pressures. Soap Dispenser Each hand washing station features an electronic liquid soap dispenser within the basin area. This eliminates any soap from dripping on counters or onto the floor, minimizing slip hazards and easing cleaning. Each dispenser features an integral check valve to hold prime for consistent reliable operation. Dispenser is top filled via a tamper resistant flip top cover accessed using a spanner wrench (included). Dispenser is compatible with most liquid soaps. Soap tank capacity is 64oz. (1893ml). The Advocate soap dispenser features built in-overflow protection utilizing an audible chirp that increases in duration when soap level approaches full. Soap level indicator flashes red when soap is low. The sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Sensor activation range is 2". Intelligent electronics allow a maximum of three activations in a 15-second period, limiting the rate at which soap can be dispensed, preventing waste and deterring vandalism. Sensor can be activated at start up to automatically prime soap dispenser. Hand Dryer Each hand washing station features an individual infrared-activated, energy efficient hand dryer. Dryer can be entered from the side immediately after washing hands. This virtually eliminates excess water on the floor. The one-of-a-kind dual-sided dryer features white LEDs to illuminate the dryer cavity while in stand-by mode, and amber LEDs while dryer is active. Dryer sensors can be turned off for 30 seconds while cleaning dryer area. The sensor uses a collimated infrared transmitting beam as part of a position sensor to detect hands. Range is 4". The dual-sided dryer will dry hands in approximately 15 seconds. The dryer nozzles contain antimicrobial protection that inhibits the growth of microorganisms such as bacteria, mold, mildew, and fungus. Dryer motor, located inside the cabinet of the Advocate, has 3' power cord that plugs into a standard 20-amp, 120-volt outlet. Easily accessible filter housing uses standard rigid polyester replacement air filters. Dryer has an on/off disconnect switch. Dryer must be unplugged for any service. Hand dryer requires a dedicated 20 amp circuit, and must be properly grounded. GFI circuit protection is recommended. Hand dryer is UL listed. AV Dryer Option Code Voltage/ Hz Watts Amps CFM d Plug Type HD2 120/60 1150 12 69 80 K HD3 230/50 1150 8.6 70 80 F HD4 230/50 1150 8.6 70 80 D

Code Compliance and Certifications Electrical Safety - United States and Canada UL 507 Electric Fans CSA C22.2 no. 113-10 Fans and Ventilators UL 60730-1 Electrical Controls for Household and Similar Use, Part 1: General Requirements. CSA-E60730-1-02, Automatic Electrical Controls for Household and Similar Use - Part 1: General Requirements FCC Part 15 Subpart Class A Electrical Safety - Europe IEC 60730-1 Automatic Electrical Controls for Household and Similar Use - Part 1: General Requirements IEC 60335-1 Household and Similar Electrical Appliances Safety Part 1: General Requirements - Edition 4 - Revisions Date 2004/03/01 IEC 60335-2-23 Household and Similar Electrical Appliances - Safety Pt. 2-23, Particular Requirements for Appliances for Skin or Hair Care - Edition 5.2 - Issue Date 2012/03/01 EN 61000-3-2 Harmonic Current Emissions EN 61000-3-3 Limits - Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-Voltage Supply Systems, for Equipment with Rated Current 16A per Phase and not Subject to Conditional Connection EN 61000-6-2 Generic Standards - Immunity for Industrial Environments EN 61000-6-4 Generic Standards - Emission Standard for Industrial Environments EN62233: 2008 Measurement Measurements for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure Plumbing - United States and Canada CSA 45.0 General Requirements for 45.5/IAPMO Z124 Plastic ASME A112.18.1-2011/CSA 125.1-11 Plumbing Supply Fittings ASME 1070-2004 Performance Requirements for Water Temperature Limiting Devices IAPMO IGC 127 Combined Hand Washer/Dryer with Integral Soap Dispenser with or without a Lavatory IAPMO IGC 156 Washfountains and Lavatory Systems with or without Water Closets Plumbing - Europe EN 14688 Washbasins. Functional Requirements and Test Methods EN 695 Kitchen Sinks. Connecting Dimensions EN 31 Washbasins. Connecting Dimensions Solid Surface - United States and Canada ANSI Z124.3-2005 Plastic Lavatories IAPMO/ANSI Z124.6 Plastic Sinks ASTM E84 Surface urn Characteristics - Rated Flame Class A Solid Surface - Europe DIN ISO 4586-2: 07-1997 High-Pressure Decorative Laminate Sheets Made from Thermosetting Resins - Part 1: Classification and Specifications DIN EN 438 - Part 1 1991 High-Pressure Decorative Laminates (HPL). Sheets ased on Thermosetting Resins (Usually Called Laminates). Classification and Specifications for Alternative Core Laminates DIN EN13501-1 Fire Classification of Construction Products and uilding Elements - Part 1: Classification Using Data from Reaction to Fire Tests Rated -s1, d0 Standard Height Mounting The standard height hand washing stations are designed to be mounted with a 34" rim height to comply with all ADA guidelines on reaches and clearances. Juvenile Height Mounting The juvenile height hand washing stations are designed to be mounted at 31" rim height to comply with all ADA guidelines, and ANSI A117.1 standard, for reaches and clearances. Source: ADA Accessibility Guidelines for uildings and Facilities (ADAAG) as amended through August 5, 2005. Junior Height Mounting The Junior Height option is designed to be mounted at a 26" rim height for use by younger children where ADA guidelines are not a concern. Hand Dryer The Advocate Lavatory System hand dryer meets requirements for safety as listed by Underwriters Laboratories, Inc. This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages. The AV-Series is A1953 and CA A 1953 compliant. Standard Equipment AV60 Advocate lavatory system features two hand washing stations with hands-free.38gpm flow faucets, soap dispensers and two hand dryers. These components are composite fiberglass, reinforced polymer with a painted, clear coat finish. End panels are satin finish 300 series stainless steel. Heavy gauge stainless steel mounting system. Trap cover is easily removed for service and encloses the following fittings: offset drains; P-traps; flexible stainless steel supply connections; and ASSE 1070 Navigator thermostatic mixing valve with combination stop/strainer/check valves. Meets the "lead free" requirements of CA A 1953. Lead Free Page 2 of 8 This information is subject to change without notice.

Dimensions for AV-Series Advocate Lavatory Systems Top View 17" (432mm) 19" (483mm) 13 3 8" (340mm) 11⁵ ₈" (295mm) 48" (1219mm) min. ADA 15½" (394mm) 27½" (699mm) Clear floor space (for each station) 30" (762mm) min. ADA Front View 4 3 8" (111mm) 5¼" (133mm) 30" (762mm) 13 1 8" (333mm) 60" (1524mm) 30" (762mm) 20¾" (527mm) 15¾" (400mm) Page 3 of 8

Dimensions for AV-Series Advocate Lavatory Systems Standard Height 40" (1016mm) 33¼" (845mm) 36¼" (921mm) 38¼" (972mm) 17½" (445mm) 9" (229mm) * 27" (686mm) * 32" (813mm) 34" (864mm) 6" (152mm) 17" (432mm) min. 8" (203mm) * Juvenile Height Junior Height 37" (940mm) 35¼" (895mm) 14½" (368mm) 9" (229mm) * 24" (610mm) * 29" (737mm) 30¼" (768mm) 31" (787mm) 33¼" (845mm) 30¼" (768mm) 9 5 8" (244mm) 24" (610mm) 25¼" (641mm) 26" (660mm) 28¼" (718mm) 6" (152mm) 17" (432mm) min. 8" (203mm) * * ADA AA Guidelines, 2004; Chapter 6: Plumbing Elements and Facilities; 606.3 Height Page 4 of 8

Dimensions for AV-Series Advocate Lavatory Systems TAS Height Grades 6 through 8 or 9 37" (940mm) 36¼" (921mm) 15½" (394mm) 9" (229mm) 28" (711mm) 30" (762mm) 31¼" (794mm) 32" (813mm) 34¼" (870mm) 6" (152mm) 17" (432mm) min. 8" (203mm) TAS Height Grades Pre-K through 5 or 6 34¼" (870mm) 34" (864mm) 13½" (343mm) 9" (229mm) 29¼" (743mm) 28" 26" (711mm) (660mm) 30" (762mm) 32¼" (819mm) 6" (152mm) 17" (432mm) min. 8" (203mm) Page 5 of 8

Rough-Ins (hot/cold, drain, electrical, and valve) for AV60 Advocate Lavatory Systems (standard height shown) 26¾" (679mm) 20½" (521mm) 6½" (165mm) 60" (1524mm) 9½" (241mm) 2¾" (70mm) E D F F D E 19" (483mm) 25¾" (654mm) (2) places 24" (610mm) (2) places 20¼" (514mm) H/C 2½" (64mm) H C 19¹ ₈" (486mm) C L 26½" (673mm) 25¼" (641mm) Finished Floor 17⁵ ₈" (448mm) 36⁵ ₈" (930mm) CODE DESCRIPTION QTY. H, C ½" nominal (⁵ ₈" O.D. Comp.) Hot/Cold Supplies, Stub-Out 2" (51mm) From Wall 1 D 1½" NPT Drain, Stub-Out 2" (51mm) From Wall 2 E 20-amp, 120-volt GFI Protected Electrical Outlet or 10-amp minimum circuit required for 230V (based on product selections) Circuit breaker to have a minimum instantaneous overload current rating of 6 times the circuit breaker's ampere rating. F #10 Anchors for Valve racket Installation 2 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FOR CODES A,, H, C, D and E 34" (864mm) No Adjustment Standard 31" (787mm) Subtract 3" (76mm) Juvenile 26" (660mm) Subtract 8" (203mm) Junior 32" (813mm) Subtract 2" (51mm) TAS Grades 6 through 8 or 9 30" (762mm) Subtract 4" (102mm) TAS Grades Pre-K through 5 or 6 FIXTURE STYLE 2 Page 6 of 8

acking Rough-Ins for AV60 Advocate Lavatory Systems (standard height shown) AV60 Areas marked as Anchor hardware is not provided. require sufficient backing compliant with local building site codes. 11¾" (298mm) 15⁵ ₈" (397mm) 60" (1524mm) 14³ ₈" (365mm) C L 11¾" (298mm) A A A A 19" (483mm) 9½" (241mm) (4) places 17⁵ ₈" (448mm) 15¾" (400mm) 23¾" (603mm) 14¼" (362mm) 45¾" (1162mm) 15¾" (400mm) 20¾" (527mm) (4) places 36¹ ₈" (918mm) (4) places Finished Floor CODE DESCRIPTION QTY. A ³ ₈" owl Anchors with a Minimum Pull-Out Force of 1,000 lbs. 4 ³ ₈" Frame Anchors 8 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FOR CODES A,, H, C, D and E 34" (864mm) No Adjustment Standard 31" (787mm) Subtract 3" (76mm) Juvenile 26" (660mm) Subtract 8" (203mm) Junior 32" (813mm) Subtract 2" (51mm) TAS Grades 6 through 8 or 9 30" (762mm) Subtract 4" (102mm) TAS Grades Pre-K through 5 or 6 FIXTURE STYLE Page 7 of 8

Model AV60 Advocate Lavatory System AV-Series Standard Selections (Must select one from each category) Activation 2A.................................................. Faucet Spout with Infrared Control Valve 2.................................................................. Tempered Line 3................................................Navigator Thermostatic Mixing Valve Soap Dispenser 1......................................................... Electronic Soap Dispenser Hand Dryer HD2................................... rushless DC Motor 120v/60hz, 20 Amp (Type "K") HD3................................... rushless DC Motor 230v/50hz, 10 Amp (Type "F") HD4................................... rushless DC Motor 230v/50hz, 10 Amp (Type "D") Component Finish (Faucet, Soap, Dryer) VS................................................................... Vapor Silver P-Trap D................................................................ Chrome (Single) G........................................................... Polypropylene (Single) Color of Terreon owl (select one): Standard Colors E-GRAY...................Empire Gray GRAPH.................... Graphite PEP-WHT.............. Peppered White LANNON................Lannonstone SAND...................... Sandtrap COLE................Cobblestone CHAR.................. Charcoal Gray WHT SAND..............White Sand JADE...........................Jade LONDON GRAY..........London Gray O-TAUPE............... Organic Taupe Element Colors SS-GRAY............... Soapstone Gray Designer Colors * ARC-CHIP.................Arctic Chip S-SAGE................. Summer Sage RIVER..................... Riverstone MYSTIC-M............... Mystic Moss STAR-D......................Stardust TerreonRE Colors* IRCH-ARK.............. irch ark DUSK......................... Dusk FERN..........................Fern MAIZE.........................Maize CA-TAN................. Canyon Tan COFFEE................ Coffee ean CORN.................... Cornfield LUESKY..................lue Sky HILLSIDE.................. Hill Side MOUNTAIN............. Mountain Top MOONDUST..............Moondust OAT........................... Oat OCEAN-MIST............Ocean Mist OLIVE........................Olive * Designer and TerreonRE colors available at an additional charge (non-cancelable, non-returnable). Trap Cover PD....................................................... High Impact Polymer, Coal AV60 Page 8 of 8 This information is subject to change without notice.