LVQD1 Verge with WashBar Technology LVQ-Series

Similar documents
LVQD3 Verge with WashBar Technology LVQ-Series

LVQD3 Verge with WashBar Technology LVQ-Series

LVSD2 Verge Wash Basin LVS-Series

LVSD2 Verge Wash Basin LVS-Series

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

LD-5010 OmniDeck with WashBar 5000 Series

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

FL-3H, FL-3L Frequency Lavatory System FL-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

AV60 Advocate Lavatory System AV-Series

AV30 Advocate Lavatory System AV-Series

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2003, SN2023, SN2004, SN2024

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Express Lavatory System MG-Series

Express Lavatory System MG-Series

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

Express Lavatory System SS-Series

DUKE UNIVERSITY CONSTRUCTION STANDARDS

WF2613 Classic Corner Washfountain with 9" Deep Bowl

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

AV60 Advocate Lavatory System AV-Series

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

SS-3N Express Lavatory System SS-Series

EXQUISITE. PERFORMANCE.

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

AV90 Advocate Lavatory System AV-Series

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

SS-1N Express Lavatory System SS-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

AV60 Advocate Lavatory System AV-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

D & L A.D.A. SOLUTIONS 448 WEST MAIN ST. AUBURN,WA (800) HOUR FAX (206) FROM THE PARTS PEOPLE. SUPPLY and MFG.

Corporate Interiors Ideabook Handwashing Fixtures, Washroom Accessories, Toilet Partition Cubicles

FAUCET PARTS - EXPLODED VIEW Model: K-59

SS-2N Express Lavatory System SS-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

A. Section Joint Sealants: Seal fixtures to walls and floors.

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

ADA guidelines. 48" min. 30" min. 8 min. 34 max. to top of lavatory rim. 27 min. knee space to bottom of bowl

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Hardwired Model Shown. WarmlyYours Infinity Towel Warmer Installation & Operation Manual

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

LA45 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

LA90 DISCONTINUED IMPORTANT!

Front Load Washer FAFW3801L W

Model Z Sundara Float Double Basin Hand Washing System

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

Installation Instructions OBSOLETE

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

School Solutions Ideabook

2). Crane Co. 4). Kohler Co. 5). Universal-Rundle Corp. Revised September 29, 2017 Commercial Plumbing Fixtures

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Model Z Sundara Reef Triple Basin Hand Washing System

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

University of Rochester October 17, 2008 Brooks Landing Business Center

DESIGN STANDARDS SECTION Toilet rooms and utility rooms to have floor drains at lowest point.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

TEMPOMIX COMFORT WATER SAVINGS VANDAL-RESISTANT SAFETY. Time flow basin mixer

PROPER WALL MOUNTING OF THE SUITMATE

TOP-LINE. TOP-LINE K13 and TL20, TL50, TL57, TL61, TL70 Series Pre-Rinse Assemblies

SECTION PLUMBING FIXTURES AND TRIM. A. Types of plumbing fixtures required for the project include the following:

Showers 1:6:0. Selector. Valves and fittings 1:6:1. Trays 1:6:2. Icon key. Showers. Blue Book Armitage Shanks. Residential.

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Plumbing Standards

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

MERIDIAN MODEL# 3793

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Transcription:

One piece plated stainless steel Washar includes touch-free soap, water and hand dryer Washar technology intuitively guides user and eliminates simultaneous activations asin and drain engineered to evacuate water and dissipate air flow Single piece molded basin eliminates caulk lines and seams Washar and basin system comes complete with mounting, access panel, drain assembly and plumbing connections Specifications The Verge Wash asin is 30" in length and is designed to accommodate one user at a time with standard lavatory spacing positioned on 30" centers. The single piece ll in One Washar allows users to access soap, water and a hand dryer without leaving the hand washing station. The unit handles washroom traffic quickly and economically, while providing each user with personal space. onstruction asin The basin has been designed to direct water to a trench drain and features a 300 series stainless steel drain cap. The basin and drain cap work together to evacuate water and dissipate airflow to prevent splashing on the user or floor. The basin is constructed of Evero Geo Series, a natural quartz surface made from a blend of bio-based resin, natural quartz, granite and other exotic minerals. It is made of 25% recycled content. Evero Pearl Series is a natural quartz surface made with bio-based resin, sea shells, recycled glass and natural quartz. It is made of 70% recycled content. asin is available in all Evero colors. Variations in the natural stone color, pattern, size, shape and shade are inherent. Due to these unique characteristics, please expect subtle shade variations when units are installed adjacent to each other. Washar ll in One chrome-plated stainless steel Washar includes touch-free soap, water and hand dryer. Load tested to 500 pounds, the Washar is secured to the basin with two anti-rotational shanks. lue LED lights help guide the user to the Washar, indicating the three functions. The LED light will change from blue to green to signify that the function is in use. Each function is easily identified by the corresponding icon on the Washar's top surface. Sensors are programmed to eliminate simultaneous activations of nearby functions. Each sensor includes a turn-off delay of 1-2 seconds to aid in a smooth, controlled hand-washing and drying operation. Washar sensors are not affected by varying skin tones or darkness. Smart technology allows the facilities manager or maintenance staff to clean and configure with ease. The Washar is powered by one 12V D adapter and plugs into a properly grounded dedicated 20 amp circuit, 120V outlet. One duplex outlet is required per station. The Washar must be unplugged before any service is performed. leaning Mode Washar has an activation feature to put the unit into cleaning mode to allow for easy cleaning of the Washar and basin without activating the functions. onfiguration Mode The Washar also has a configuration mode to identify how many cycles are on the soap, faucet and dryer. Mode also allows for dryer speed adjustment at low, medium and high levels. Page 1 of 6 3/9/2017 radley_sink_verge_ Soap Dispenser The soap dispenser is located on the left side of the Washar. This eliminates any soap from dripping on counters or onto the floor, minimizing slip hazards and allows for easy cleaning. hoose between a foam or liquid soap dispenser, which are compatible with most bulk soaps. Soap system accommodates up to a 1 gallon container to reduce the number of soap replacements. When the LED light above the soap function turns to solid red, simply check the level and replace the soap container with a full container if necessary. The soap system includes an adapter to fit many 1 gallon soap containers available on the market. Please visit https://www./maintenance/soap-dispensers for soap recommendations. Faucet Faucet is located in the center of the Washar and has a spray angle of approximately 17 degrees off the vertical. hoose either a 0.5 gpm or 0.35 gpm P rubber tip aerator. Maximum run time is 30 seconds. The 0.5 gpm aerator option is the equivalent to 0.25 gpc and the 0.35 gpm aerator option is the equivalent to 0.18 gpc. utomatic 5 second purge within 24 hours of the last use. The solenoid valve is powered by the shared 12V D adapter. Recommended operating range is 20-80 psi. Dryer The hand dryer is located on the right side of the Washar, allowing users to dry their hands immediately after washing. This virtually eliminates excess water on the floor. The dryer motor provides heated air at three speeds, high-medium-low, which can be field adjusted by placing the Washar in configuration mode. The single sided dryer will dry hands in approximately 15 seconds depending on user preference. The decibel range with hands in air stream is 76 d (high speed) to 64 d (low speed). The dryer motor, located behind the access panel, is csus listed. ccess Panel Minimalistic panel is composed of decorative 300 series stainless steel. Plumbing components, dryer motor, and soap tank are concealed within the panel. The new swing down access panel is designed to ease the maintenance process by eliminating tools and only requires one person for installation. Top edge of the access panel has been hemmed to reduce sharpness. Support racket racket design allows for flexible stud or wall blocking anchor locations. Eliminates the need for in-wall carriers and frame. System is IPMO certified to meet or exceed NSI load requirements. Strainer and Drain ssembly System Strainer and drain assembly system comes complete with 300 series stainless steel trench drain cap, tailpiece and polypropylene p-trap. Optional chrome plated p-trap available. The multi-station system is configured with one drain and one set of supplies to reduce the cost associated with individual drains and supplies. This plumbing fixture is designed for hand washing only. It is not Intended to dispense water for human consumption through drinking or for preparation of food or beverages.

Models (Must select one) Model Description Verge with Washar Technology LVQ-Series, One-Station Standard Selections (Must select one from each category) ctivation (select one) W1 hrome-plated Washar with Infrared ontrol erator Type (select one) 35 0.35 gpm P Rubber Tip erator 50 0.50 gpm P Rubber Tip erator Water Supply (select one) TM Navigator Thermostatic Mixing ssembly w/stops and Hot and old Supply Hoses NONE No Valve Option Selected (includes stop and supply hose) Soap Type (select one) FSD Foam Soap Dispenser - 1 gallon soap container by others LSD Liquid Soap Dispenser - 1 gallon soap container by others Hand Dryer (select one) HD1 D Motor 120v/60hz, 20 mp Trench Drain ap (select one) DR1 Stainless Steel Trench Drain ap olor of Evero asin (select one) Geo Series NDORR ndorra EVEREST Everest NSSU Nassau NTRTI ntarctica GLIER Glacier ay PTGONI Patagonia LK-SE lack Sea KLHRI Kalahari SIERR Sierra Madre O abo MOJVE Mojave TUSNY Tuscany DENLI Denali MYKONOS Mykonos YUKON Yukon Pearl Series (available at an additional charge) (Non-cancelable, non-returnable) KOY koya LK-MOON lack Moon olor of ccess Panel (select one) STIN Stainless Steel P-Trap (select one) S-POLY Single Polypropylene P-Trap S-HROME Single hrome Plated P-Trap Mounting Heights Standard Height Mounting The standard height hand washing stations are to be mounted with a 33-1/2" rim height to comply with D/TS reaches and clearances. Juvenile Height Mounting The juvenile height hand washing stations are designed to be mounted at 30-1/2" rim height to comply with D/TS reaches and clearances. O Height Mounting The Ontario uilding ode hand washing stations are designed to be mounted at a 33" maximum rim height to comply with O reaches and clearances. ode ompliance and ertifications NSI Standards Evero Natural Quartz Surface is Home Innovation Lab ertified to meet the requirements of S 45.5/IPMO Z124. cup pproval Verge Lavatory is Uniform Plumbing ode (UP), International Plumbing ode (IP) and National Plumbing ode of anada (NP) approved through the International ssociation of Plumbing and Mechanical Officials (IPMO). Manufactured in compliance with IG 156, S 45 Series (R08) & SME 112.18.1/S 125.1. Standard product selections contained within this document are third party ERTIFIED to NSF/NSI 372 meeting the Lead-Free content requirement. ny product configured with custom options will be OMPLINT with NSF/ NSI 372 meeting the Lead-Free content requirement. ertified to NSF/NSI 372 Page 2 of 6 3/9/2017 radley_sink_verge_

Dimensions for Wash asin Top View 13-1/2" (343) 11" (279) 5-1/2" (140) Ø 1-1/2" (38) 21" (533) 5" (127) 14-3/8" (366) 2-3/4" (70) 26-3/4" (681) 1-1/2" (40) Front View 29-3/4" (756) 3-3/4" (95) 5" (127) 5" (127) (509) 30" (762) (508) Page 3 of 6 3/9/2017 radley_sink_verge_

Dimensions for Wash asin Side View Side View - anadian Standards 3-3/4" (95) 20 12-3/8" (314) Dryer 11-3/4" (299) Faucet 6-1/2" (165) 21" (534) 3-5/8" (92) Spray ngle ~ 17 3-7/8" (99) 3-3/4" (95) 20 12-3/8" (314) Dryer 11-3/4" (299) Faucet 6-1/2" (165) 21" (534) 3-5/8" (92) Spray ngle ~ 17 3-7/8" (99) 7-1/2" (189) (507) 33" (839) 28-15/16" (735) 7-1/2" (189) (507) D/TS Standard Height D/TS Juvenile Height (hildren 6-12 years) Dim 33-1/2" (851mm) 30-1/2" (775mm) Dim 27" (686mm) 24" (610mm) Dim 13-1/2" (343mm) 10-1/2" (267mm) S Standard Height O/ Standard Height Dim 33-1/2" (851mm) 33" (838mm) Dim 29-29/32" (760mm) 28-15/16" (735mm) Dim 13-1/2" (536mm) 13" (330mm) Page 4 of 6 3/9/2017 radley_sink_verge_

Structural Rough-Ins for Wash asin Mounting for Standard, D and TS height shown. Points, and require sufficient backing compliant with local building codes. WRNING Ensure bowl is completely seated in the wall bracket and securely fastened to the wall at point. 5" Wall racket (127) L 2-1/2" (64) Secure bracket to wall using min. 3/8" anchor bolt to the left of /L and min. 3/8" anchor bolt to the right of /L. The anchor bolt to the right of /L must be min. 5" apart from the anchor bolt to the left of /L. When mounting is complete, check to ensure the bracket is level. See Step 1: racket Mounting for more information. 33-1/2" (851) S S 31-1/2" (800) 29-1/2" (749) ottom of racket 28" (711) 15-1/8" (384) 5-1/2" (140) Trap over racket S1 S1 9-1/8" (231) 12-5/8" (320) Finished Floor 9-1/8" (231) 12-5/8" (320) 3/4" (19) Trap over racket 14-1/4" (362) 25-1/4" (654) ODE DESRIPTION QTY. Install (1) 3/8" wall anchor with a minimum pull-out force of 1,000 lbs. per local codes at locations shown 2 Provide structural backing compliant with local building codes. 2 Install wall anchor with a minimum pull-out force of 100 lbs. per local codes at locations shown 4 S #10 Wall nchors for Soap ontrol ox racket 2 S1 #10 Wall nchors for Soap Tank racket (100 lb pull out) 2 RIM HEIGHT VERTIL HEIGHT DJUSTMENTS FIXTURE STYLE 33½" No djustment Standard Height, D, TS and S 30½" Subtract 3" Juvenile, D and TS 33" Subtract ½" O/ Page 5 of 6 3/9/2017 radley_sink_verge_

Plumbing and Electrical Rough-Ins for Wash asin Mounting for Standard, D and TS height shown. 33-1/2" (851) E 24-1/8" (613) 2-1/4" (57) H 1" (25) 17-1/2" (444) Min. Finished Floor ODE DESRIPTION QTY. 1½" NPT Drain, Stub-out 2" from wall 1 H, ½" Nominal (⁵ ₈" O.D. omp.) Hot/old supplies, Stub-out 2" from wall 1 E 110V GFI protected electrical outlet 1 Page 6 of 6 3/9/2017 radley_sink_verge_