Emergency Planning for Institutional Facilities

Similar documents
FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

ICC CODE CORNER 2015 International Fire Code

Defend In Place 2012 IFC Overview of Institutional Occupancies

Public. Mike Free Health. State of Alabama Department of

Public Health Fax: Web Site:

E25 (D) Automatic controls for general means of egress lighting

AHC Meeting #7 July 12-13, Occupancy WG Report

Welcome to the AccessibilityOnline Webinar Series. Listening to the Webinar. Listening to the Webinar, continued

Welcome to the AccessibilityOnline Webinar Series. Listening to the Webinar

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

EMERGENCY PLANNING AND PREPAREDNESS

AHC MEETING #4 PART I ROUND 1 ISSUES CODE CHANGES

EMERGENCY PLANNING AND PREPAREDNESS

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Agency for Health Care Administration

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

BCAC Egress Work Group

AD HOC HEALTHCARE COMMITTEE MEANS OF EGRESS WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B MOE COMMITTEE

2000 to 2012 Hospital K-tag crosswalk matrix for hospitals 2000 Tag #

Following are code change proposals submitted through Adhoc Health from General study group and related changes. General. Position.

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

DEALING WITH FIRE SAFETY

Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA

Emergency Planning and Preparedness

Agency for Health Care Administration

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

EC 5.10 FIRE PREVENTION MANAGEMENT

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Agency for Health Care Administration

Report on First Revisions with Statement June 2014 NFPA 101

St. Vincent s Health System Page 1 of 6

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

APPENDIX A International Building Code Amendments

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

FIRE PROTECTION KEY DESIGN CONCEPTS IN HEALTHCARE FACILITIES Scott Twele, Aman Shah Steven Dannaway. AIA Healthcare Group

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

Fxx - 13 K-66 Smoking Regulations (New)

IRVING FIRE DEPARTMENT EMERGENCY PLANS

Residential Care Facilities Requirements

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

FIRE PLAN. In order to assure the safety of patients, visitors and staff, a standard response to fire or the potential of fire is required.

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

Written Fire Safety Plans

Status Update K-tag WG 12/8/2011

Agency for Health Care Administration

Agency for Health Care Administration

Review of Revisions to NFPA 1, 2015 Edition

Lauzon Life Safety Consulting

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Agency for Health Care Administration

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

First Revision No NFPA [ Section No ]

Hospice of Rutherford County Policies and Procedures

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

Renovation Program. Renovation Program GENERAL

Established /10/2015. Doran Pruisner Dan Wood

Property Name & Address [ Property Name ] - [ Property Address ]

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Fire Protection Coffee Break Training May 2016

ICC Committee on Health Care Hospitals and Nursing Homes Group A Draft Proposals Revised Copyright 2017 International Code Council, Inc.

Fire evacuation drill

CHAPTER 7 ALTERATIONS LEVEL

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Chapter 2: Definitions

Life Safety Codes for Assisted Living Facilities

Overview of Fire Alarm Provisions Based on the 2012 IBC, IFC and NFPA 72, 2013 Edition

Assisted Living Facilities

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Agency for Health Care Administration

Level I Chapter 1 Worksheet

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

2015 Recommended Building Code with Amendments. The Executive Committee of the Central Iowa Code Consortium does ordain as follows:

Residential Based Care Facility Guidelines

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

May 27, Mayor Joanne D. Yepsen Saratoga Springs Commissioners City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

NFPA 101 Life Safety Code Introduction for Fire Alarm, Security and Locksmith Qualifiers

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

DISTRIBUTION: HOSPITAL-WIDE VERSION #:4 REPLACES:

Emergency Planning and Preparedness

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

Iowa (2) Delete section and insert in lieu thereof the following new section:

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

For additional information regarding R-3.1 residential care facilities please contact (951)

Agency for Health Care Administration

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Transcription:

Emergency Planning for Institutional Facilities Pacific ADA Emergency Preparedness Webinars Presented by: Kimberly Paarlberg, ICC Based on the 2015 edition of the International Building Code (IBC) and the International Fire Code (IFC) Contents Occupancy classification Planning Notification and Communication Means of Egress Special Building Construction 2 Copyright 2017 International Code Council 1

Goal Have a basic understanding of the unique emergency criteria for institutional facilities such as assisted living facilities, nursing homes, hospitals and jails. New criteria for other health care facilities, such as doctor s offices, outpatient surgery centers and detached emergency centers. 3 Objectives Understand why assisted living facilities, nursing homes, hospitals and jails may not be able to use the standard evacuation systems. Identify what plans need to be developed and practiced in these facilities. Understand what alternatives there are for notification other than standard audible alarms. Identify what building elements are required for compartmentation and smoke protection. 4 Copyright 2017 International Code Council 2

Occupancy Classification 5 Overview The main factors that distinguish the various occupancies are: Level of care Length of stay Capabilities of care recipients for self evacuation Number of care recipients 6 Copyright 2017 International Code Council 3

Level of Care CUSTODIAL CARE. Assistance with day-to-day living tasks; such as assistance with cooking, taking medication, bathing, using toilet facilities and other tasks of daily living. Custodial care includes persons receiving care who have the ability to respond to emergency situations and evacuate at a slower rate and/or who have mental and psychiatric complications. MEDICAL CARE. Care involving medical or surgical procedures, nursing or for psychiatric purposes. 7 Length of stay 24-HOUR BASIS. The actual time that a person is an occupant within a facility for the purpose of receiving care. It shall not include a facility that is open for 24 hours and is capable of providing care to someone visiting the facility during any segment of the 24 hours. 8 Copyright 2017 International Code Council 4

Capability for self evacuation INCAPABLE OF SELF-PRESERVATION. Persons who, because of age, physical limitations, mental limitations, chemical dependency or medical treatment, cannot respond as an individual to an emergency situation. 9 Types of facilities AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing or similar care on a less than 24-hour basis to individuals who are rendered incapable of selfpreservation by the services provided. CLINIC, OUTPATIENT. Buildings or portions thereof used to provide medical care on less than a 24-hour basis to persons who are not rendered incapable of selfpreservation by the services provided. 10 Copyright 2017 International Code Council 5

Types of facilities DETOXIFICATION FACILITIES. Facilities that provide treatment for substance abuse, serving care recipients who are incapable of self-preservation or who are harmful to themselves or others. FOSTER CARE FACILITIES. Facilities that provide care to more than five children, 21/2 years of age or less. GROUP HOME. A facility for social rehabilitation, substance abuse or mental health problems that contains a group housing arrangement that provides custodial care but does not provide medical care. 11 Types of facilities HOSPITALS AND PSYCHIATRIC HOSPITALS. Facilities that provide care or treatment for the medical, psychiatric, obstetrical, or surgical treatment of care recipients who are incapable of self-preservation. NURSING HOMES. Facilities that provide care, including both intermediate care facilities and skilled nursing facilities where any of the persons are incapable of self-preservation. 12 Copyright 2017 International Code Council 6

Group I-3 Types of facilities Correctional centers Detention centers Jails Prerelease centers Prisons Reformatories 13 Group I-3 - Characteristics Supervised environment 24 hour stay Security or restraint > 5 detainees Incapable of self preservation Condition 1 through 5. Least to greatest level of restraint 14 Copyright 2017 International Code Council 7

Group I-2 Types of facilities Foster care facilities Detoxification facilities Hospitals and psychiatric hospitals Nursing homes 15 Group I-2 - Characteristics Supervised environment 24 hour care Nursing & medical care > 5 patients Condition 1 - Nursing homes and foster care facilities. Do not provide emergency care, surgery, obstetrics or in-patient stabilization units. Condition 2 - Hospitals. Do provide emergency care, surgery, obstetrics or in-patient stabilization units. 16 Copyright 2017 International Code Council 8

Group I-1& R-4 Types of facilities Alcohol and drug centers Assisted living facilities Congregate care facilities Group homes Halfway houses Residential board and care facilities Social rehabilitation facilities 17 Group I-1 Characteristics Supervised environment 24-hour stay Custodial care >16 residents Condition 1. Respond to an emergency situation without assistance Condition 2. Respond to an emergency situation with limited verbal or physical assistance. 18 Copyright 2017 International Code Council 9

Group R-4 Characteristics Supervised environment 24-hour stay Custodial care > 5 and 16 residents Condition 1. Respond to an emergency situation without assistance Condition 2. Respond to an emergency situation with limited verbal or physical assistance. 19 Group B Types of facilities Ambulatory care facilities Outpatient clinics Laboratories, testing and research Professional services (dentists, physicians) 20 Copyright 2017 International Code Council 10

Group B - Characteristics < 24 hour stay Medical care Outpatient clinic capable of self preservation Ambulatory care facility - Incapable of self preservation >=4 patients incapable had additional safety requirements 21 Adhoc Health Care Committee Committee has been working on hospital, nursing home and ambulatory care facility requirements in the codes Coordinating with latest K-tags used for licensure Info on the International Code Council website https://www.iccsafe.org/codes-tech-support/cs/icc-adhoc-committee-on-healthcare-ahc/ 22 Copyright 2017 International Code Council 11

Planning Pre-Planning for Emergencies Fire evacuation plans Fire safety plans Lockdown plans Associated drills Worked out with the building owner/renter and the fire department Updated annually or when necessitated by changes Available for review 24 Copyright 2017 International Code Council 12

Fire Evacuation Plans (FEP) Emergency routes Strategy - Evacuation or defend in place Critical equipment operation Assisted rescue procedures Verifying full evacuation Emergency responders Notification of occupants Notification of fire department Emergency voice/alarm communication system 25 Fire Safety Plans (FSP) Reporting emergency Evacuation or relocation of occupants Site plans occupancy assembly point, fire hydrants, fire truck route Floor plans exits, routes, areas of refuge, fire alarm, extinguishers, fire hoses Major fire hazards Persons responsible 26 Copyright 2017 International Code Council 13

Lock-down plans Occupant notification Emergency responders notification Accountability Recall Communication Coordination Training 27 Practice Employee training Resident training Emergency evacuation drills Emergency Preparedness for Institutional Facilities 28 Copyright 2017 International Code Council 14

Additional requirements for: Institutional Jails Group I-3 Hospitals Group I-2, Condition 2 Nursing homes Group I-2, Condition 1 Assisted living/group homes- Group I-1 & R-4 Ambulatory care Group B 29 Group I-3 Employee training. Instructed in the use of manual fire suppression equipment. Housing cells shall unlock remotely or an employee shall be within three floors or 300 feet horizontal distance of each cell. In Group I-3 Conditions 3, 4 and 5, Employee start emergency evacuation within 2 minutes of an alarm. Residents can readily notify an employee of an emergency. 30 Copyright 2017 International Code Council 15

Group I-3 Emergency evacuation drills Employees, quarterly on each shift 31 Group I-2 - FEP Include a description of special staff actions. Evacuate all visitors and patients Procedures for evacuation for patients with needs for containment or restraint and post-evacuation containment, where present. A written plan for maintenance of the means of egress. Procedure for a defend-in-place strategy. Procedures for a full-floor or building evacuation, where necessary. 32 Copyright 2017 International Code Council 16

Group I-2 - FSP A copy of the plan maintained at the facility at all times. Location and number of patient sleeping rooms and operating rooms. Location of adjacent smoke compartments or refuge areas. Path of travel to adjacent smoke compartments. Location of special locking, delayed egress or access control arrangements. Location of elevators utilized for patient movement 33 Group I-2 Emergency evacuation drills Employees, quarterly on each shift Movement of patients to safe areas or to the exterior of the building is not required. Where emergency evacuation drills are conducted after visiting hours or where patients or residents are expected to be asleep, a coded announcement shall be an acceptable alternative to audible alarms. 34 Copyright 2017 International Code Council 17

Group I-1 & R-4 FEP/FSP A copy maintained at the facility at all times Include special employee actions Including fire protection procedures necessary for residents Amended or revised upon admission of any resident with unusual needs. 35 Group I-1 - FEP Group I-1 Condition 2 occupancies Include procedures for evacuation through a refuge area in an adjacent smoke compartment and then to an exterior assembly point. 36 Copyright 2017 International Code Council 18

Group I-1 & R-4 - FSP Location and number of resident sleeping rooms. Location of special locking or egress control arrangements. 37 Group I-1 & R-4 Employee training. Training as part of new employee orientation Employees periodically instructed and kept informed of their duties and responsibilities under the plan. Records of instruction maintained. Plan reviewed by the staff not less than every two months. 38 Copyright 2017 International Code Council 19

Group I-1 & R-4 Resident training. Residents capable of assisting in their own evacuation shall be trained in the proper actions to take in the event of a fire. Residents shall be trained to assist each other in case of fire to the extent their physical and mental abilities permit them to do so without additional personal risk. The training shall include actions to take if the primary escape route is blocked. In Group I-1 Condition 2 occupancies, training shall include evacuation through an adjacent smoke compartment and then to an exterior assembly point (staged evacuation). Where the resident is given rehabilitation or habilitation training, methods of fire prevention and actions to take in the event of a fire shall be a part of the rehabilitation training program. 39 Group I-1 & R-4 Emergency evacuation drills. All occupants, semi-annually on each shift Employees, additional two times a year on each shift. Twelve drills with all occupants in the first year of operation. Timing of drills can be planned. The fire officials can choose to not require building evacuation due to bad weather. In Group R-4, residents shall be instructed in the use of emergency escape and rescue openings 40 Copyright 2017 International Code Council 20

Ambulatory care - FEP Description of special staff actions Procedures for stabilizing patients Options Defend-in-place, Staged evacuation, or Full evacuation in conjunction with the entire building if part of a multitenant facility. 41 Ambulatory care - FSP Locations of patients who are rendered incapable of selfpreservation. Maximum number of patients rendered incapable of selfpreservation. Area and extent of each ambulatory care facility. Location of adjacent smoke compartments or refuge areas, where required. Path of travel to adjacent smoke compartments. Location of any special locking, delayed egress or access control arrangements. 42 Copyright 2017 International Code Council 21

Ambulatory care Staff training. Training as part of new employee orientation Employees periodically instructed and kept informed of their duties and responsibilities under the plan. Records of instruction maintained. Plan reviewed by the staff not less than every two months. 43 Ambulatory care Emergency evacuation drills. Employees, not less than four times per year. Movement of patients to safe areas or to the exterior of the building is not required. 44 Copyright 2017 International Code Council 22

Notification& Communication 45 Signage Evacuation plans at elevators Signage at any non-accessible exits 46 Copyright 2017 International Code Council 23

Signage Visual exit signs at stairway entrances Tactile exit signs at stairway entrances 47 Signage Visual signage within the stairway Tactile signage indicating floor levels Tactile signage at the door leading to the exit discharge 48 Copyright 2017 International Code Council 24

Two-way Communication Within areas of refuge (in non-sprinklered buildings) At elevator lobbies in sprinklered buildings (2009, 2012and 2015 IBC) Variety of options Allow for communication and feedback between emergency responders and people who need assistance 2018 Not required in hospitals or nursing homes due to staff training 49 Audible and Visible alarms Installed in accordance with NFPA 72. Manual fire alarm pull stations must be accessible. Allows for manual fire alarm boxes at the nurse station Copyright 2017 International Code Council 25

Visible Alarms All public spaces All common spaces In some of the resident s bedrooms in Group I-1 Allows for private mode signaling in patient care areas Healthcare Accessibility in the International Codes 51 Sprinkler automatic notification Group I-1, I-2, I-3, R-4 are required to be sprinklered. Activation of the sprinkler system automatically notifies the fire department Upon arrival the fire department can use the sprinkler panel to identify the floor where the fire is happening Standby power on the elevators allow for the fire department to move to the fire floor so they can offer assistance. 52 Copyright 2017 International Code Council 26

Means of Egress (MOE) Means of Egress (MOE) A means of egress is an unobstructed path to leave buildings, structures, and spaces Comprised of: Exit Access Exits Exit Discharge 54 Copyright 2017 International Code Council 27

Accessible MOE An accessible means of egress is a continuous and unobstructed accessible route of egress travel from any accessible point in a building or facility to a public way. 55 ADA & ABA Standards 207 Require compliance with the International Building Code (IBC) for accessible means of egress OR IBC 2003 Section 1007 IBC 2000 with 2001 Supplement Section 1003.2.13 56 Copyright 2017 International Code Council 28

ADA & ABA Standards What about compliance with later editions? Permitted where equivalent or better ( equivalent facilitation in the ADA Standards Section 103) 2015 57 MOE: Minimum Number MOE required from each space and room Drawing courtesy of Access Board 58 Copyright 2017 International Code Council 29

Means of Egress Assisted rescue when necessary Defend in place (i.e., hospitals, jails) Assisted evacuation at stairways Assisted evacuation at elevators with standby power 59 Elevator with Standby Power Elevator with standby power Required in buildings 5 stories or higher Drawing courtesy of Access Board 60 Copyright 2017 International Code Council 30

Group I-2 No exterior steps permitted. 61 Defend-in-place Used in Group I-2 and I-3 The option to subdivide a building so that smoke cannot move freely throughout a floor or between floors This allows for patients/residents to remain in place, or be related to another area on the floor where they would be protected from smoke and fumes Evacuation of these patients/residents in bad weather could be dangerous for them due to level of care required 62 Copyright 2017 International Code Council 31

Opening protectives Cross-corridor doors that close automatically upon activation of the fire alarms 63 Refuge Area/Smoke compartments Within each smoke compartment, an adequately-sized area (called a refuge area) must be available for care recipients to be relocated to during an emergency. They must met these criteria: >= 30 net square feet for each non-ambulatory care recipient. Can be located with corridors, care recipient rooms, treatment rooms, lounge or dining areas. Occupants must have access to the refuge area without passing through adjacent tenant spaces. 64 Copyright 2017 International Code Council 32

Smoke Compartment Independent Egress 65 Independent Egress A means of egress shall be provided from each smoke compartment created by smoke barriers: Requires a means of egress, not an exit. Cannot return through the smoke compartment from which egress originated. Can pass through multiple smoke compartments. 66 Copyright 2017 International Code Council 33

Special building construction 67 Hospitals Group I-2 Condition 2 Design allowances for suites for areas such as ICU, CCU, Emergency Dept. 96 wide corridors for movement of patients in beds Limitations for equipment in corridors 68 Copyright 2017 International Code Council 34

Nursing home housing units Group I-2 Condition 1 Allowances for limited cooking and living spaces open to the corridors 69 Assisted living Group I-1 Dwelling units separated from each other, other spaces and the corridors with fire partitions Condition 2 - subdivided into smoke compartments to allow for staged evacuation of residents 70 Copyright 2017 International Code Council 35

Special locking arrangements In areas for dementia, Alzheimer's and psychiatric treatment special allowances allow for egress doors to be controlled by staff or delayed egress 71 Ambulatory care facilities The facility must be separated from other tenants by smoke partitions If >10,000 sq.ft, the facility must be subdivided into smoke compartments of less than 22,500 sq.ft. Sprinkler system required for the floor and all floors below. Some of the requirements reduced is there are fewer than 4 patients not capable of self - preservation 72 Copyright 2017 International Code Council 36

Questions? 73 Copyright 2017 International Code Council 37