Product Specifications Linear Accelerator Relay Junction Box

Similar documents
Product Specifications 480 VAC, 175A Main Power Distribution Panel

Product Specifications 480 VAC, 70A Main Power Distribution Panel

Product Specifications Warning Light Control Cabinet

Product Specifications Auto Restart Main Power Distribution Panel

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications Warning Light Control Cabinet

Product Specifications Fail Safe Emergency Power Off Control Panel 480V 3 Phase

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

MaxLite LED High Bay Fixtures

Electric Duct Heaters

INSTALLATION and OPERATION INSTRUCTIONS

MaxLite Polygon Linear LED Light

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

ELP21LU3-LF-HLOL THREE CHANNEL

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Installation, Operation & Service Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Owner s Manual Hydro-X Vacuum Pac

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

SECTION AUTOMATIC TRANSFER SWITCHES

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

For use with models: BP , BP , BP

GENESIS Indoor Air Conditioners

OPERATING INSTRUCTIONS

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

/ How To Order

Innovative Lighting R-Series Overhead LED Conversion Kits

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

CURRENT LIMITING LIGHTING CONTROL PANEL Supplemental Overcurrent Protection City of Los Angeles Approved Version

Service Parts, Kits and Accessories

MacroAir AirVolution HVLS Fans

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

SECTION HVAC Fans

Panel Mounted Heat Exchangers by Dantherm, Inc.

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

MacroAir AirElite HVLS Fans

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Beacon 800 Gas Monitor Operator s Manual

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Remote Relay Module (RRM)

MacroAir AirSpan HVLS Fans

Innovative Lighting R-Series Vertical Refrigeration

MaxLite LED Round Pendant Highbay Series

BACKUP BATTERY INSTALLATION INSTRUCTIONS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Desiccant / Pump Dehumidification System. Model Operating Manual

MANUAL RESET ALARM RELEASE

Universal Fan and Light Remote Control

Quest Power Electric Heat EHS 31 Pro

Controllers. Instruction Manual WARNING

Centro-Matic Automated Lubrication Systems System Controls

Instruction Manual WARNING

Description. Applications

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Owner s Manual Phoenix FireBird

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

NXM2G Installation and Operating Manual

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Model 4001 Series Single Channel Controller

D E S I G N G U I D E REVISED 10 / 2017

D E S I G N G U I D E REVISED 9 / 2018

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Owner s Manual Phoenix Aquadry TX 200

PART GENERAL 1.01 SECTION INCLUDES

Ultrasonic Reflective Sensor

SU2000-SM. model OPTICAL TURNSTILES DESCRIPTIVE SPECIFICATIONS TYPICAL INSTALLATION SITES COMMON APPLICATIONS ALVARADOMFG.COM

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Operation Manual. Rev. E GEM-II Self Contained Gas Detector.

Instruction Manual and Warranty

Quest Power Electric Heat EHS 62 Pro

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Transcription:

NOVA Energy & Automation Product Specifications Linear Accelerator Relay Junction Box Model NEAVRJB-C3 03 January 2012

Product Description 1. Standard Applications The Nova NEAVRJB-C3 relay junction box provides controls for all of the necessary components interfaced with the Varian Clinac including: laser positioning, room lights, warning lights, door switches, and the emergency stop system. The low voltage control panel provides a safe, low voltage interface between the imaging equipment, warning lights, room lights, operator s control, and room line voltage. The system was designed to meet the hospital-grade requirements of medical imaging suites. 2. System Compatibility The Nova NEAVRJB-C3 is compatible with the following medical imaging equipment: Varian Medical Systems: 2100 C/D, 2300C/D, 21EX, 23EX, Novalis Tx, Trilogy, IX, Silhouette, Clinac ix and several other related projects incorporating relay junction box controls 3. Identification Varian Medical Systems: The proper distribution panel can be identified in the Varian Site Planning Packet keynote 65.142 Equal to item VRJB-C3 4. Features/ Benefits Features Dedicated terminals and multiple ground terminal bars are clearly marked with Varian drawing reference numbers. Includes Varian specific pre terminated Interface Cables Surge Suppression installed for each relay coil. All input and output signals are protected with fuses. UL and cul listed to conform to NEC. Labeled to conform with NFPA99, NFPA-70. No minimum load required Factory wired and tested. Simple field configuration can accommodate several different equipment installations. Isolated heavy duty contacts for room lighting Isolated heavy duty contacts warning lights All components are within a small 45lb enclosure Short Circuit current rating of 5 kaic at 120VAC Manufactured in the USA Co Author: JF 2

Benefits Designed, tested, and installed on several projects world wide Acceptable low cost alternative to GE Manufactured using the highest quality components for high reliability and long life Single junction point for all low voltage and lighting needs for a linear accelerator installation. Manufactured to a tolerance which exceeds the specifications of Varian equipment. Reduces installation time and cost by eliminating delays in obtaining individually enclosed components and by eliminating on site assembly Accommodates different room lighting applications and circuit loads (120V, 277V, 220V, LED, Incandescent, and fluorescent) Accommodates different warning light applications and circuit loads (120V, 277V, 220V, LED, Incandescent, and fluorescent) Integrated design provides all of the controls into an easy to configure panel Eliminated the multiple control systems Provides a standardized platform for other future modifications or upgrades. Compact size and reduced weight for easy installation Life time product support Figure 1 Nova Linear Accelerator Relay Junction Box- Inside Co Author: JF 3

5. Specifications Model Application Input Voltage Input Current Room Lighting Voltage Maximum Room Lighting Load Warning light voltage NEAVRJB-C3 Relay junction box for Varian linear accelerator equipment 110, 277, 220 (600VAC max) AC input (maximum): 20 A 110, 277, 220 (600VAC max) 20 Amps 110, 277, 220 (600VAC max) Maximum Warning Light Load 5 Amps per zone (Beam off, Beam On, Beam Ready, Generator On, X- ray On), 20 Amps total load Laser On Control Voltage (CV) Room Lights Out CV EPO Out CV EPO In CV DC Door Interlock In CV DC Door Interlock Out CV OPT Neutron Door Interlock Out CV OPT Door Interlock In CV AC Door Interlock Out CV AC Door Interlock In CV Beam Off Light Out CV Beam On Light Out CV Beam Ready Light Out CV Generator Light Out CV X-ray light out CV Remote Emergency Off CV Approvals Varian Supplied -12VDC or +24VDC Varian Supplied -12VDC or +24VDC Varian Supplied -12VDC Varian Supplied -12VDC UL/cUL Co Author: JF 4

6. Weight and Dimensions Mounting Dimensions Weight Mounting Enclosure Enclosure Sealing Warning and Room Lighting Controller is provided in a steel enclosure suitable for surface, wall or above the ceiling mounting. Height: 23.62 (600mm) Width:14.2 (400mm) Depth: 6 (150mm) 45 lbs. (20.45 kg) Rear wall mounting holes (4). Spaced 0.79 (20mm) from enclosure edge. Optional mounting brackets are available 16 Gauge Carbon Steel, all rounded corners 1 gland plate in the enclosure base. Foamed-in place polyurethane door gasket Finish Dip coat primed, powder coated in textured RAL 7035 Latching Mechanism Interior Panel Protection Category Two ¼ turn latches with double-bit inserts (cam lock). Door is hinged on the left side but can be swapped if specified when order is placed. Zinc-Plated subpanel IP 66 to EN60 529/09:2000, complies with NEMA 4. Enclosure Approvals: UL, CSA, TUV, GL, Lloyds, VDE, Bureau Veritas Figure 2 Enclosure Dimensions: Outside, Mounting, Depth Top and Bottom have removable gland plates for easy mounting of conduit fittings. Co Author: JF 5

7. Warranty This limited warranty set forth below is given by Nova Automation ( Seller ) with respect to the electrical equipment ( Product ) packaged with this limited warranty. The Product, when delivered to you in new condition in its original packaging, is warranted against defects in materials or workmanship as follows: For a period of one (1) year from the date of original purchase, defective parts or a defective Product returned to a Seller, or its authorized service providers, as applicable, and proven to be defective upon inspection, will be repaired, or exchanged for a new Product, as determined by the Seller, or the authorized service provider. This limited warranty covers all defects encountered in normal use of the Product, and does not apply in the following cases: Loss of or damage to the Product due to abuse, mishandling, alteration, accident, electrical current fluctuations, failure to follow operating, maintenance or environmental instructions prescribed by Seller, failure to follow Sellers installation instructions, or service performed by someone other than Seller or its authorized service provider. Nova assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any consequential or incidental damages arising from the use of the product. Nova Automations entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement of the product. WARRANTY IS VOID IF PRODUCT IS NOT USED FOR THE PURPOSE FOR WHICH IT WAS MANUFACTURED. 8. Product Service and Technical Assistance Nova Automation, LLC 2722 N. Avondale Blvd Milwaukee WI 53210 PH# 262-309-2950 Website: www.novaautomation.net Co Author: JF 6