Segment design & and Bus Diagnostics

Similar documents
Fieldbus Foundation TM Bus diagnostics and troubleshooting

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

Two global companies, one solution.

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Assembly. Host Sub-D Alarm

C-Bus Four Channel General Input Unit Installation Instructions

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

EasyLog Data Logger Series

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

EasyLog Data Logger Series

operational excellence Solutions for

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Refrigerated Incubator Model and Operating Instructions

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Temperature Data Logging

Intelligent addressable fire alarm control panel

SC-F3G User Manual 1.0

SIL2-Interface/ -Signal Conditioners Series DuoTec

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

MHC Series Sensors

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Reliably Advanced Extinguishing Control

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

POL-200-TS User Manual

Specification for On-Line UPS Battery Monitoring and Data Management System

AmpLight group management

OVEN INDUSTRIES, INC.

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Different types of Fire Alarm System

DS7400Xi Addressable Control/ Communicator

GPS or DCF 77. DTS Masterclock

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

M2500 Engine Controller Installation Manual

C-Bus Four Channel Analogue Output Unit Installation Instructions

IntesisBox BACnet/IP Server - Notifier ID3000 series

APC BC300 Series 40kW 208/450/480V User Guide

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Advanced HART Diagnostic Suite

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

PROFIBUS-PA Display RID 261 PROFIBUS-PA

QA16 Addressable System

Danfoss gas detection units

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Added password for IP setup page : Password must be in IP format!

DigiTrace NGC-family

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Security Alarm Systems

For Complete Fire and Gas Solutions

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Reliably Advanced Extinguishing Control

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

DualCom GradeShift UDL QUICK GUIDE & INSTRUCTION MANUAL

DC 60 & DM 60 displays

Industrial Grade Gas Detection Detecting The Difference

RS485 MODBUS Module 8AI

Danfoss gas detection unit Type GD Heavy Duty

Smart Combiners CG-VMU SolarVu. Installation Guide

explosion protection automation global partner of the process industry

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

DTS MOBATime's Distributed Time System

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Aritech. Fault Finding Guide. Addressable Fire. FFG2000 Revision 1.6, March

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Technical Manual. Level Alarm Unit CARLA & WIDS

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

HD COMMUNICATOR. Features & Benefits: Unique continuous Redundant Routing capacity. Up to 20km reach on a single copper pair.

technical datasheet technical datasheet

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

GasGard 100 Control System

ACTIVE INFRARED BARRIER

CARD ACCESS CONTROL SYSTEM

Arc Fault Protection System D1000

MO n : 12JMC rév A

Section PERIMETER SECURITY SYSTEMS

AUTROSAFE 4 A new level in interactive fire detection systems

GMH 285 / GMH 285-BNC

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Dryer Master DM510 Commissioning Guide

Advanced FireAlarm Panel 1-4Loop

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

FTS500 Series. Handheld OTDR Test Set.

Networked Access Control Panel. Installation Guide

Transcription:

Segment design & and Bus Diagnostics Arasu Thanigai Business Development Manager Pepperl+Fuchs Pte Ltd, Singapore On behalf of FF End user Council Taiwan 1 Taiwan FF Seminar

Part1 - Segment design & Verification Tools Part2 Validation and Diagnostic tools 2 Taiwan FF Seminar

Segment Design and Verification Tools How to design Foundation Fieldbus segments? 3 Taiwan FF Seminar

Segment Design and Validation Tools Fieldbus allows to connect many devices on the same bus cable, but How many devices can I really connect? What cable should I use, and what cable distances can I really achieve? What happens in case of a short circuit in the field? 4 Taiwan FF Seminar

Segment design Engineers especially new to Fieldbus technology have some Common questions that has to be answered before proceeding to the real design. What are the common questions about Fieldbus design? Fieldbus allows to connect many devices on the same bus cable, but how many devices can I really connect? what cable should I use, and what cable distances can I really achieve? what happens in case of a short circuit in the field? what Power Supplies and wiring blocks can I connect in hazardous areas? how do I do the termination? and how do I document my calculations and designs? How do I do the proper segment design for various zones of applications 5 Taiwan FF Seminar

Segment Design and Validation Tools What Power Supplies and wiring blocks can I connect in hazardous areas? How do I do the termination? And how do I document my calculations and designs? What happen to my segment due to ambient temperature change? Will it work properly? 6 Taiwan FF Seminar

Segment Design and Validation Tools Most component manufacturers provide own versions of the segment design tools Design tools are available in either Excel based versions or graphical based versions. Most segment design tools generate design report. The validation of a Fieldbus segment includes checks like application of bus terminators, cable distances, voltage and current values as well as short circuit simulation checks. 7 Taiwan FF Seminar

Segment Design and Validation Tools Graphical segment design tool example Pepperl+Fuchs Segment Checker design tool www.segmentchecker.com 8 Taiwan FF Seminar

Segment Design and Validation Tools The Segment Checker is a software tools for design and validation of Fieldbus networks. The Segment Checker is a graphical design tool with report generator. The validation of a Fieldbus segment includes checks like application of bus terminators, cable distances, voltage and current values as well as short circuit simulation checks. 9 Taiwan FF Seminar

Segment Design and Validation Tools Before a segment can be validated, it needs to be designed. 10 Taiwan FF Seminar

11 Taiwan FF Seminar

Using Segment Checker - Validation The project report tab lists a result summary of the checks performed by the software. 12 Taiwan FF Seminar

Using Segment Checker - Report Sample Report 13 Taiwan FF Seminar

Segment Design and Validation Tools Excel spreadsheet based segment design tool example Stahl Segment design tool 14 Taiwan FF Seminar

Segment Design and Validation Tools 15 Taiwan FF Seminar

Segment Design and Validation Tools Excel spreadsheet based segment design tool example MTL Segment design tool 16 Taiwan FF Seminar

Segment Design and Validation Tools 17 Taiwan FF Seminar

Segment Design and Validation Tools Other Vendors e.g STAHL, may also provide segment design tools that consists of their own interface components. DCS Companies also provide segment design tools that consists of interface components from various vendors 18 Taiwan FF Seminar

Part 2 - Validation and Diagnostic tools 19 Taiwan FF Seminar

Need for diagnostics Field study by installation and commissioning Engineers around the world shows that more than 80% of the plant disturbances come from the physical layer level be it conventional 4-20mA applications or Fieldbus applications. Unless the engineers sufficiently trained for Fieldbus applications the most common mistakes are made at the physical layer level such as wiring faults, wrong termination etc. 20 Taiwan FF Seminar

Typical problems Electrical wiring of Fieldbus is same as conventional same problems (loose wires, water ingress, faulty devices, EMC, etc) Difference: bus topology locating the problem is difficult and time consuming (many devices in one loop; Interoperability) Available tools are optimized for conventional technology tools are not able to solve majority of problems 21 Taiwan FF Seminar

Typical problems Improperly closed housing Loose wire Error log showing intermittent faults Internally modified Interoperability testing by end user Electro-magnetic interference Faulty field device Cable Wrong degradation termination 22 Taiwan FF Seminar

Diagnostic Tools Engineering tool Digital Volt Meter Portable oscilloscope Fieldbus tester Network sniffer Advanced Online diagnostic tools Portable diagnostic tools 23 Taiwan FF Seminar

Network Problems Commissioning problems Insufficient power Poor wiring Interoperability Problems introduced at changes and expansion Additional grounding points Version incompatibilities Long term problems Water filling Deteriorating cable 24 Taiwan FF Seminar

Basic Troubleshooting Communication errors are automatically detected and indicated in operator console and engineering tools. As for all troubleshooting, removing parts one-by-one until it works finding the fault through elimination, is a useful way. This may detect communication problems as well as insufficient current being available from the power supply or galvanic isolator (barrier). It is also a good idea to test a problem device on its own on the workbench. If there is no communication at all, there is a problem with its configuration or installation. 25 Taiwan FF Seminar

Types of Communication Errors Configuration download is not working Error Log" window appears: block or parameter problem Function block link from a block output in one device to a block input in another device does not appear to be working. Block input status is Bad, no communication Supervisory data acquisition does not work Asterisk (*) or invalid character is appearing in operator console 26 Taiwan FF Seminar

Communication Errors Communication errors are mainly caused by installation problems, not configuration or failure: Poor connections Wrong or no terminator placement Too low or unstable power supply Too long or overpopulated spurs Wrong or no grounding Water filling due to poor plugs and cableglands 27 Taiwan FF Seminar

H1 Bus Power Simultaneous power supply and communication on a single pair of wires. DC power 9-32 VDC AC communication (@31.25 khz) Power consumption varies from one device to another. There are no upper or lower limits. Power consumption is indicated on device ID plate. The lower consumption the better, especially in intrinsic safety applications. It is important that the wire resistance is not too high making the supply voltage at the device too low. Good connections and junctions must be made It is possible to test the voltage (not signal) on the installed network using a hand-held Digital Volt Meter (DVM). 28 Taiwan FF Seminar

Check Points (1) Are two (and only two) terminators connected per bus? Be especially careful where redundant power is used. Is the display of the not communicating device working having any indication at all? Is the power supply at the terminals of the not communicating DEVICE sufficient > 9 V? Is the polarity correct? Verify continuity of wires, and that short circuits are not caused by junction box water filling. 29 Taiwan FF Seminar

Power Supply Example Number of devices: Impedance output voltage is 19 V Cable loop resistance for 1.9 km is 84 ohm Device needs minimum 9 V Maximum voltage drop is therefore 10 V (19-9) Maximum total current draw thus is 120 ma (10/84) Each device needs 20 ma (many devices are as little as 12-15 ma) Maximum 6 devices, or shorter cable (120/20) Cable length: Impedance output voltage is 19 V Device needs 20 ma and minimum 9 V Maximum voltage drop is therefore 10 V (19-9) Total current draw for 12 devices thus is 240 ma (12 x 20) Maximum cable loop resistance is therefore 42 ohm (10/0.24) Cable resistance is 22 ohm/km- in each direction 30 Taiwan FF Seminar Maximum 0.95 km, or less devices (42/(2 x 22))

Fieldbus Tester Voltage (> 9 V) LAS signal level (> 150 mv) Number of devices Lowest device signal level (> 150 mv) Average noise (< 75 mv) Peak noise (< 75 mv) Signal level of new device (> 150 mv) Inverted signal Frame error Draws 15 ma from the bus! 31 Taiwan FF Seminar

Fieldbus Wiring Validator Used together with Fieldbus Tester (Relcom FBT-3) Test the wiring, terminators, and junction bricks/couplers No Fieldbus devices, host, or power shall be connected Simulates power and communication, in place of host Permits tester to monitor: Voltage (drop) Signal level (attenuation) Noise level FBT5 Control Room Trunk FBT3 Field 32 Taiwan FF Seminar

Bus analyzer / Configurator Monitors device communication with monitor software Monitors communication faults with monitor software Configure devices with configurator software 33 Taiwan FF Seminar

Earthing (Grounding) Don't ground shield in both ends Make sure shield or ground wire does not get in touch with instrument housing Other earth points along the wire Open earth connection at host to measure Earthing point for surge protector, not fieldbus shield 34 Taiwan FF Seminar

Advanced Troubleshooting To find serious problems a bus analyser may be used to study the communication messages in order to find a protocol interoperability problem. An oscilloscope (balanced/isolated - e.g battery operated) may also be a useful tool in extreme cases of interoperability problems. 35 Taiwan FF Seminar

Oscilloscope Well formed waveform: Sloped raising edge Flattish top Sloped falling edge Flattish bottom Symmetrical Signal Level > 350 mv 200-350 mv 150-200 mv Conditi on Excell ent 36 < 150 mv Poor Taiwan FF Seminar Good Fair

Terminator If a terminator is missing the signal amplitude will be too high If too many terminators are present the signal amplitude will be too low 37 Taiwan FF Seminar

Noise 38 Taiwan FF Seminar

Error Rate CRC error exceeding 0.8% will not perform well 39 Taiwan FF Seminar

Fieldbus Sniffer (FBView) Permits non-experts to capture communication and email to experts for analysis Expert can filter, time, find, and decode frames 40 Taiwan FF Seminar

Locating physical layer faults Field JB FTC DCS Bulk 24VDC Fieldbus Wiring Block Segment 4 Segment 3 Segment 2 Segment 1 FF Power Supply Single redundant wiring H1 card 41 Taiwan FF Seminar

Measurements Tools of the Trade Multimeter Handheld Tester Handheld Communicator Oscilloscope Notebook Bus Analyzer Advanced Diagnostic Module Segment voltage Segment current Segment noise (low freq.) Segment noise (high freq.) Segment signal level Segment signal jitter Instrument signal level = Instrument signal jitter Instrument noise (individual) Fieldbus termination = = Segment earth fault (imbalance) Device communication Communication faults Cable degradation (trending) Device configuration Remote access 42 Taiwan FF Seminar Supported = Result incomplete Requires shutdown Fully

Portable Diagnostic tools Stand Alone diagnostic tools Some Diagnostic tools can also be used for data storage 43 Taiwan FF Seminar

Portable Diagnostic Module DM-AM USB interface Fieldbus interface Bulk Power Features of the Diagnostic Module User-configurable warning and alarm levels for long-term diagnostic Alarming with time stamping (final version) History/trending for all measured values stored in the diagnostic module (final version) DCS system integration with OPC (final version) Features of the PC Tool Commissioning tool for easy warning and alarm level definition Documentation tool, file or print out Expert system wizard to isolate cause of deviation or errors (final version) Build in Fieldbus oscilloscope 44 Taiwan FF Seminar

45 Taiwan FF Seminar

FBT6 Fieldbus powered LC display Does the same function as FBT3 and additionally Device add & drop indication Shield short indication when + or shorted to shield The address and signal level of each device on the network is displayed in turn by pushing the SELECT button. Checks for any device not responding to a LAS pass token and indicates the address of the last device that failed to respond to the LAS pass token Upload measurement data to a PC via USB port Draws Power from Fieldbus 46 Taiwan FF Seminar

Field Communicator 375 Configures Fieldbus devices in the field Measures and monitors DC voltage Average noise Signal level per segment Certified for Intrinsic safe applications 47 Taiwan FF Seminar

Online Diagnostic tools Usually integrated in the Power conditioner system Can also be used for data storage and trending Analyses complicated Fieldbus issues Some tools integrated with Fieldbus Oscilloscope Some tools generate automatic commissioning report Can transport the data on H1 bus or separate protocol like RS485 and Ethernet 48 Taiwan FF Seminar

Cash Flow The effect of Advanced Diagnostics Plan and purchase Install and commission Operate and maintain Commission Monitor Troubleshoot Longer plant uptime Know before you act Actionable information in clear text Verify against original design Automated checkout procedures Segment Checker: design of the physical layer 49 Taiwan FF Seminar

Commissioning until now Always on the critical path Manual, step-by-step procedure Labor intensive Requires Screw driver Check sheet Pencil Multimeter Oscilloscope Connect one device at a time Disconnect after testing Test Report 50 Taiwan FF Seminar

Simple Commissioning Steps with ADM x Test Report Verify address setting Wire up devices in the right location Check shielding Activate communication Use automated work procedures Testing Documentation All devices at once Wiring remains undisturbed Commissioning Wizard 51 Taiwan FF Seminar

Commissioning Wizard Simple to use Eliminates manual test procedures Ensures compliance with AG181 and IEC 61158-2 Creates baseline report: Snapshot of all measurements Complete documentation Recommends warning and alarm limits for the ADM Stores limits in non-volatile memory Reduces pre-commissioning time by up to 80% 52 Taiwan FF Seminar

Control the physical layer Supervision and diagnostics Measurements, trending, alarming Part of the Power Hub Online and in real-time with remote access from the control room and via Internet Simple-to-use DTMs Signal measurements Color-coded status indicators Built-in oscilloscope for greatest detail NOT a Fieldbus Device 53 Taiwan FF Seminar

RS485 T Diagnostic Manager Industrial Ethernet DCS / Maintenance Station Control Cabinet 54 Taiwan FF Seminar

55 Taiwan FF Seminar

Snapshot Functionality Automatically generated documentation Baseline report for online comparison and trending Live supervision during operation 56 Taiwan FF Seminar

Diagnostic Menu ADM delivers actionable information for fast fault finding 1 Active messages 2 Actionable information with solution guideance based on expert knowledge 2 3 History with timestamps When the failure occured disappeared Export function for external analysis and storage 1 3 57 Taiwan FF Seminar

Oscilloscope function Many trigger events selectable! This telegram is lost 58 Taiwan FF Seminar

Practical Example Approx. 7 ms In this example the frequency of noise was approx. 150Hz 59 Taiwan FF Seminar

ISbus Fieldbus Power Supply Advance diagnostics Same functionality as Basic FPS, plus: Integrated physical layer diagnostics: trunk voltage, trunk current, communication level, noise level, asymmetry, jitter, waveform snapshot adjustable warning levels for pro-active maintenance warning warning with simple relay contact Software independent in redundant operation, diagnostics is also redundant 60 Taiwan FF Seminar 27 & 29 th page July 60 2010

ISbus Fieldbus Power Supply Advance Diagnostics Green LED: OK segment runs in specification with 100 % quality Yellow LED: WARN segment runs in specification but with reduced quality (warning level can be adjusted 5 90 %) Soon maintenance required Red LED: BAD segment out of specification (incl. cable break & short circuit) Maintenance required now! 61 Taiwan FF Seminar 27 & 29 th page July 61 2010

Fieldbus Power Supply Advanced diagnostics Failure detection of physical layer problems: jitter, noise, asymmetries, voltage level, current level Indication via LED Signalling via relay contacts: 62 Taiwan FF Seminar

F809F diagnostic tool Host control system Instrument Management Software (including fieldbus diagnostics) power supply system On-line Diagnostic Module Controller I/O Alarm Fieldbus 63 Taiwan FF Seminar

F809F Diagnostic tool 64 Taiwan FF Seminar

Conclusion Follow the System design guidelines provided by AG guidelines at www.fieldbus.org Fieldbus Physical layer specification IEC 61158-2 Good grounding and shielding concept as per the plant conditions Installation guidelines Approved and registered products Right diagnostic tools to reduce installation and commissioning time 65 Taiwan FF Seminar

QUESTIONS? 66 Taiwan FF Seminar