Laboratory thermostatic chambers

Similar documents
Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

ZL Laboratory freezers

Laboratory refrigerators

Drying ovens, incubators, cooled incubators

Made in Poland. Established POL-EKO-APARATURA. products. Your partner in laboratory analysis and technological processes

Table of contents. Table of contents. Development history THERMOSTATIC EQUIPMENT. Cooled incubators (ST) Laboratory refrigerators. Laboratory freezers

Caution: Before using the device first read carefully this manual!

Stability Chambers & Rooms

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Constant climate chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chamber with ICH-compliant illumination

Constant climate chambers

Constant climate chamber with humidity

EC 160 CO 2. Incubator

Heated and Refrigerated Incubators

Drying and heating chambers

laboratory & sterilization technology

Constant climate chambers

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

FUNCTION LINE HEATING AND DRYING OVENS

Laboratory Refrigerator/Deep Freezer TC 802

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

INSTRUCTION MANUAL. Matos Refrigerators / Freezers

DOUBLE DOOR FREEZER.

& Freezers. Selection Guide. Laboratory Refrigerators & Freezers. Accessories & Options

Environmental simulation chamber for complex alternating climate profiles

Environmental Chambers

Model C 170 CO 2 incubators with hot air sterilization

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Constant climate chambers

NC SERIES. Bench Top Steam Sterilizers

Instruction Manual. DRY-Line DL 56 Prime: DL 112 Prime: DL 180 Prime:

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Caution: Before using the device first read carefully this manual!

laboratory & sterilization technology

Refrigerated Incubators / Environmental Testing Chambers

Chromatographic Air circulated Refrigerator, two-door TC 603

New Generation KBF 240 series

VWR INCU-Line Peltier Cooled Incubators. Instruction Manual

ULTRA.GUARD ultra low temperature freezer

NC 100. Vertical Steam Sterilizer

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

ICP450. Compressor-cooled incubator. Product specification

Natural convection, Film type heater. Amb. +3 to 60 / Amb to , 0.3, 0.1 at 37 / 0.36, 0.54, 0.18 at 98.6

Environmental Chambers

Caution: Before using the device first read carefully this manual!

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

KMF Environmental test chamber for constant climate

Model KBWF 240 Growth chambers with light and humidity

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

OT SERIES. Bench Top Steam Sterilizers

Model KBWF 720 Growth chambers with light and humidity

Constant climate chambers

REFRIGERATOR M E D I C A L.

AZTECA A LITRE STERILISER


Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Digital incubating/ refrigerating benchtop shakers

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Commodity Description

ICH260C. Climate Chamber. Product specification

Multi-Lab REFRIGERATORS Frigidere medicale

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

NC SERIES. Horizontal Steam Sterilizers

Plant growth chambers

Constant climate chambers

Forced Convection Laboratory Incubators. Reliable Performance For Universal Applications. Forced Convection Laboratory Incubators

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

ICH750L. Climate Chamber. Product specification

OVENS Forced Convection Ovens. Economy Forced Convection Ovens. Vacuum Ovens.

LAUDA ECO. Precise, economical, flexible

MS Mini Incubator MO-MINI. Incubator. Specification. Ordering Information. Accessories

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Photo Stability Chamber

Vacuum drying chambers. VD VDL series

Ovens. General Applications. Forced Convection Ovens. Natural Convection Ovens. Vacuum Ovens. Clean Ovens, Class 100

Benchtop & Compact Test Chambers

Model KBF 240 Constant climate chambers with large temperature / humidity range

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Refrigerated Incubator. Reliable Performance For Universal Applications

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

ICH110. Climate Chamber. Product specification

Constant climate chambers

Walk in Freezer. Comfortable work environment

Universal Applications

creating the right atmosphere NEW SERIES Galaxy Plus 170 litre CO 2 Incubators Advanced design for optimum results

Chromatographic Air circulated Refrigerator, two-door TC 603

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

NEW GENERATION. Efficient use of valuable space INCUBATORS

FITOCLIMA 600 & 1200 PHARMA

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Transcription:

Laboratory thermostatic chambers I

Laboratory thermostatic chambers Thermostatic cabinets single chamber double chamber Laboratory refrigerators single chamber double chamber Thermostatic boxes Laboratory freezers Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers ECO - basic version STD - standard version TOP+ - professional version TOP+ Control and EasyLab-T PLUS software Laboratory Incubators Cooled incubators Drying ovens Pass-through drying ovens Laboratory sterilizers Equipment with photoperiodic and phytotron system Climatic chambers Climatic chambers with phytotron system OPTIONS AND ACCESSORIES Parameters list Parameters description Options and accessories Temperature protection 9 12 13 14 17 18 19 20 24 25 26 27 29 30 33 36 39 41 44 47 47 51 52 53 57 67

Thermostatic cabinets ST Application BOD determination microbiological research plant growing and microorganisms breeding at specified temperature storage of liquids and samples for physicochemical analysis Thermostatic cabinets are equipped with both heating and cooling systems and can provide a stable temperature in a range of +3...+70 C regardless of ambient conditions. LCD graphic display internal socket (option) acces port (option) external glass door (option) fan door lock (option) ST 2/2+ 7

ST Thermostatic cabinets Advantages available in two versions - basic and TOP+ single or double chamber versions capacity from 68 to 1460 liters aluminum or stainless steel interior (depending on model) housing: powder coated sheet, stainless steel linen finish (INOX/G) or polished (INOX/S) (depending on model) thermal insulation - polyurethane foam solid, glass (ST*/A option) or double (ST*/C option) door type forced air convection heating and cooling systems to hold set temperature regardless of ambient conditions defrosting function (see page 56) wheels in ST 1200 and 1450 model four temperature ranges available +3 +40 C +3 +50 C (ST/50 option) +3 +60 C (ST/60 option) +3 +70 C (ST/70 option) LCD graphic display illuminated touch buttons microprocessor temperature control temperature sensor fail alarm (see page 56) power failure control system (see page 56) real time clock sound alarm (see page 56) self-check function (auto control) automatic fan shut down after completing the program Program possibilities in basic version six segment temperature-time profile cycle run of the program 3 user programs memory adjustable start delay feature (from 1 min to 99:59 h) adjustable time of holding the set temperature from 1 min to 31 days, or continuous operating recording min, average and max temperature value separately for each segment overeview of set parameters during operating time over temperature sound alarm temperature program priority (see page 56) Program possibilities in TOP+ version, see page 28. Temp. [ C] off 100% 100% 100% 100% 100% off 70 C Maximal temperature T2 55 C TIME 2 - parameter set by User: T1 37 C TIME 1 D - adjustable start delay (1 min...99,59 h) - fan speed control T0 20 C D 37 C 55 C temperature T1/T2 - set temperature TIME 1/2 - set time 0,5 h 3h 1,5 h Time [h] All POL-EKO-APARATURA products can be supplied with a calibration certificate issued by an accredited Measurement Laboratory. Further information is available on pages 87-89 and our website www.pol-eko.eu

Thermostatic cabinets ST Thermostatic cabinets in TOP+ version The ST thermostatic cabinets are available in the TOP+ professional version too. The TOP+ version features a full colour 5,7 touch screen with internal memory to store all measurement data. These are the only thermostatic cabinets which can be controlled from a PC, as they can be connected to an Ethernet network that enables the user to program the equipment virtually from any place in the world. Details on page 28. Standard equipment solid door temperature range +3 +40 C (+3 +60 C in TOP+ version) RS 232 interface and USB port ; RS 232 or USB cable must be purchased additionally (RSK or USBK) wire shelves (with slides set) in case of aluminum interior and stainless steel wire shelves in case of stainless steel interior manfacturer s test certificate at +37 C operation manual in English and English menu (other languages ) over temperature protection 1.0 class according to DIN 12880 TOP+ standard equipment see page 28 Options and accesories (icon description see page 51) INOX DIN 2.0 DIN 3.1 DIN 3.2 DIN 3.3 90% +50 C +60 C +70 C KG 10...100% 30% PWP KAFKA 9 5 SMS RS 422 RS 485 RS 232 RS 422 RS 485 USBK IQ OQ PQ for basic version only for basic version and TOP+ for TOP+ only

ST Single chamber cabinets Available options : ST/50 - extended temperature range to +50 C ST/60 - extended temperature range to +60 C ST/70 - extended temperature range to +70 C ST*/C - internal glass door ST*/A - external glass door PLUS - automatic defrosting during operating FOT - photoperiodic system ST 2+ INOX INOX/S with ST 2+/C option Model ST 1+ ST 2+ ST 3+ ST 4+ ST 5+ ST 500 ST 700 ST 1200 ST 1450 Parameter air convection forced [l] 68 150 200 250 300 493 625 1365 1460 chamber capacity 1 [cu ft] 2,4 5,2 7,0 8,8 10,5 17,4 22,0 48,2 51,6 2 door type solid / glass or double (option) temperature range [ C] +3...+40 / up to +50, +60 or +70 (option) / +3...+60 in TOP+ version [ F] +37...+104 / up to +122, +140 or +158 (option) / +37...+140 in TOP+ version controller microprocessor with external LCD graphic display interior aluminum / stainless steel housing powder coated sheet / stainless steel linen finish INOX/G or polished INOX/S width 550 600 600 600 600 635 725 1440 1440 overall dims [mm]** height 600 850 1050 1250 1450 2025 2025 2025 1970 depth 650 600 600 600 600 810 860 860 890 width 470 520 520 520 520 510 600 1310 1340 3 internal dims [mm] height 430 660 860 1060 1260 1510 1510 1510 1460 depth 300 420 420 420 420 640 690 690 750 max shelf workload [kg]* - 10 10 10 10 10 20 30 30 30 PW version 100 100 100 100 max unit workload [kg] - 20 30 40 50 60 100 150 300 300 W version nominal power [W] 160 170 170 330 330 400 400 550 550 weight [kg] 30 48 52 61 66 105 115 195 200 temperature resolution [ C] 4 temperature fluctuation at +37 C [ C] over temperature protection voltage 50/60 Hz [V] 6 shelves fitted / max warranty manufacturer ±0,2 ±0,2 ±0,3 ±0,3 ±0,3 2/2 every 0,1 3/4 3/4 4/6 4/7 24 months POL-EKO-APARATURA ±0,2 3/11 ±0,2 ±0,3 class 1.0 according to DIN 12880 / class 2.0, 3.1, 3.2, 3.3 (option) / class 3.3 in TOP+ version 110-120/220-240 3/11 5 2 x 3/11 ±0,3 5 2 x 3/11 * - at even surface workload ** - dims of door handles, power cable and leveling feet or wheels not included 1 - working capacity of chamber can be smaller 2 - additional internal glass door 3 - dims of units with double door can be smaller 4 - fluctuation measured in centre of the chamber 5 - two columns with 3 shelves each 6 - "fitted number of shelves fitted, included in price 6 - "max" number of shelves which can be fitted

Double chamber cabinets ST Available options ST/50 - extended temperature range up to +50 C ST/60 - extended temperature range up to +60 C ST/70 - extended temperature range up to +70 C ST*/C - internal glass door ST*/A - external glass door PLUS - automatic defrosting during operating FOT - photoperiodic system Example of configuration To configure a double-chamber thermostatic cabinet, e.g.: - upper chamber equipped with solid door and temperature up to +60 C - lower chamber equipped with double door and temperature up to +40 C, you select: for ST 1/1+: ST 1/1+ and ST/60 option for upper chamber + ST 1/C option for lower chamber ST 2/2+ with additional options Model ST 1/1+ ST 1/1/1+ ST 2/2+ ST 2/3+ ST 2/4+ ST 3/3+ ST 350/350 Parameter air convection chamber capacity 1 door type temperature range controller interior housing overall dims [mm]** 3 internal dims [mm] max shelf workload [kg]* max unit workload [kg] nominal power [W] weight [kg] temperature resolution [ C] 4 temperature fluctuation at +37 C [ C] over temperature protection voltage 50/60 Hz [V] 6 shelves fitted / max warranty manufacturer [l] [cu ft] [ C] [ F] width height depth width height depth - PW version - W version * - at even surface workload ** - dims of door handles, power cable and leveling feet or wheels not included 1 - working capacity of chamber can be smaller 2 - additional internal glass door 68/68 550 1170 650 470 430 300 68/68/68 150/150 forced 150/200 150/250 2 solid / glass or double (option) 200/200 +3...+40 / up to +50, +60 or +70 (option) / +3...+60 in TOP+ version +37...+104 / up to +122, +140 or +158 (option) / +37...+140 in TOP+ version microprocessor with external LCD graphic display aluminum / stainless steel powder coated sheet / stainless steel linen finish INOX/G or polished INOX/S 294/294 2,4/2,4 2,4/2,4/2,4 5,2/5,2 5,2/7,0 5,2/8,5 7,0/7,0 10,3/10,3 550 600 600 600 600 720 1740 1670 1870 2070 2070 2025 650 600 600 600 600 860 470 520 520 520 520 600 430 660 660/860 660/1060 860 700 300 420 420 420 420 700 10 10 10 10 10 10 30 20/20 20/20/20 30/30 30/40 30/50 40/40 75/75 320 480 350 350 350 350 800 65 100 100 105 110 115 162 every 0,1 ±0,2 ±0,2 ±0,3 ±0,3 ±0,3 ±0,3 ±0,5 class 1.0 according to DIN 12880 / class 2.0, 3.1, 3.2, 3.3 (option) / class 3.3 in TOP+ version 110-120/220-240 2/2 2/2 3/4 3/4 3/4 3/4 2/6 24 months POL-EKO-APARATURA 3 - dims of units with double door can be smaller 4 - fluctuation measured in centre of the chamber 5 - two columns with 3 shelves each 6 - "fitted number of shelves fitted, included in price 6 - "max" number of shelves which can be fitted

CHL Laboratory refrigerators Application storage of water and sewage samples, piezometer leachate storage of ASA, GC or HPLC calibration standards storage of reagents chemical storage general storage Laboratory refrigerators are equipped with a cooling system and can provide a stable temperature lower than ambient. RS 232 and USB port LCD graphic display illuminated touch buttons adjustable shelf with slide set fan CHL 2+

Laboratory refrigerators CHL Advantages single or double chamber versions capacity from 68 to 1460 liters aluminum or stainless steel interior (depending on model) housing: powder coated sheet, stainless steel linen finish (INOX/G) or polished (INOX/S) (depending on model) thermal insulation - polyurethane foam solid, glass (CHL*/A option) or double (CHL*/C option) door type forced air convection heating and cooling systems to hold set temperature regardless of ambient conditions defrosting function (see page 56) wheels in CHL 1200 and 1450 model two temperature ranges available 0 +10 C -10 +10 C (CHL*/T option) for CHL 500-1450 LCD graphic display iluminated touch buttons microprocessor temperature control temperature sensor fail alarm (see page 56) power failure control system (see page 56) real time clock sound alarm (see page 56) self-check function (auto control) Program possibilities single segment temperature-time profile temperature program priority adjustable start delay feature (from 1 min to 99:59 h) adjustable time of holding the set temperature from 1 min to 31 days, or continuous operating recording min, average and max temperature value separately for each segment overeview of set parameters during operating time over temperature sound alarm Temp. [ C] 20 C off D 11 T1 9 C TIME 1 9 C - parameter set by User: D - adjustable start delay (1 min...99:59 h) T1 - temperature TIME 1 - time 0,5h 5h Time [h] All POL-EKO-APARATURA products can be supplied with a calibration certificate issued by an accredited Measurement Laboratory. Further information is available on pages 87-89 and our website www.pol-eko.eu

CHL Laboratory refrigerators Laboratory refrigerators CHL All refrigerators, thermostatic cabinets and cooled incubators can optionally be equipped with an automatic defrosting function (PLUS option). It features a countinuous operating without a necessity to defrost, keeping a stable temperature in the chamber. Details on page 65. Standard equipment solid door temperature range 0 +10 C RS 232 interface and USB port ; RS 232 or USB cable must be purchased additionally (RSK or USBK) wire shelves (with slides set) in case of aluminum interior and stainless steel wire shelves in case of stainless steel interior manfacturer s test certificate at +4 C operation manual in English and English menu (other languages ) over temperature protection 1.0 class according to DIN 12880 Options and accesories (icon description see page 51) INOX DIN 3.2 10...100% PWP KAFKA SMS RS 422 RS 485 RS 232 RS 422 RS 485 USBK 9 5 IQ OQ PQ

Single chamber refrigerators CHL Available options CHL*/T - extended temperature range to -10 C CHL*/A - external glass door PLUS - automatic defrosting function during operating A mini refrigerator TB 35 INOX with an additional battery power supply guarantees continuous operating in case of power failure. Details on page 19. TB 35 INOX Model CHL 1+ CHL 2+ CHL 3+ CHL4+ CHL 5+ CHL 500 CHL 700 CHL 1200 CHL 1450 Parameter air convection forced [l] 68 150 200 250 300 493 625 1365 1460 chamber capacity 1 [cu ft] 2,4 5,2 7,0 8,8 10,5 17,4 22,0 48,2 51,6 2 door type solid / glass or double (option) temperature range [ C] +0...+10 +0...+10 / -10...+10 (option) [ F] +32...+50 +32...+50 / +14...+50 (option) controller microprocessor with external LCD graphic display interior aluminum / stainless steel housing powder coated sheet / stainless steel linen finish INOX/G or polished INOX/S width 550 600 600 600 600 635 725 1440 1440 overall dims [mm]** height depth 600 650 850 600 1050 600 1250 600 1450 600 2025 810 2025 860 2025 860 1970 890 width 470 520 520 520 520 510 600 1310 1340 3 internal dims [mm] height depth 430 300 660 420 860 420 1060 420 1260 420 1510 640 1510 690 1510 690 1460 750 max shelf workload [kg]* - 10 10 10 10 10 20 30 30 30 PW version 100 100 100 100 max unit workload [kg] - 20 30 40 50 60 100 150 300 300 W version nominal power [W] 160 170 170 330 330 400 400 550 550 weight [kg] 30 48 52 61 66 105 115 195 200 temperature resolution [ C] 4 temperature fluctuation at +4 C [ C] over temperature protection voltage 50/60 Hz [V] 6 shelves fitted / max warranty manufacturer ±0,2 ±0,2 ±0,3 ±0,3 ±0,3 2/2 every 0,1 110-120/220-240 3/4 3/4 4/6 4/7 24 months POL-EKO-APARATURA ±0,2 class 1.0 according to DIN 12880 / class 3.2 (option) 3/11 ±0,2 ±0,3 3/11 5 2 x 3/11 ±0,3 5 2 x 3/11 * - at even surface workload ** - dims of door handles, power cable and leveling feet or wheels not included 1 - working capacity of chamber can be smaller 2 - additional internal glass door 3 - dims of units with double door can be smaller 4 - fluctuation measured in centre of the chamber 5 - two columns with 3 shelves each 6 - "fitted number of shelves fitted, included in price 6 - "max" number of shelves which can be fitted

CHL Double chamber refrigerators Available options for each chamber : CHL*/T - extended temperature range to -10 C CHL*/A - external glass door PLUS - automatic defrosting during operating There is a possibility to combine different sizes of ST+ and CHL+ chambers between models ST/CHL+ 2-5. (e.g ST 2+/CHL 3+) Example of configuration To configure a double chamber laboratory refrigerator, e.g.: - upper chamber with solid door and temperature range 0 +10 C - lower chamber with solid door and temperature range -10 +10 C, you select: for CHL 350/350 model: CHL 350/350 and CHL 350/T option for lower chamber CHL 2 / ZLN 85+ Model CHL 1/1+ CHL 1/1/1+ CHL 2/2+ CHL 2/3+ CHL 2/4+ CHL 3/3+ CHL 350/350 Parameter air convection chamber capacity 1 door type temperature range controller interior housing overall dims [mm]** 3 internal dims [mm] max shelf workload [kg]* max unit workload [kg] nominal power [W] weight [kg] temperature resolution [ C] 4 temperature fluctuation at +4 C [ C] over temperature protection voltage 50/60 Hz [V] 6 shelves fitted / max warranty manufacturer [l] [cu ft] [ C] [ F] width height depth width height depth - PW version - W version * - at even surface workload ** - dims of door handles, power cable and leveling feet or wheels not included 1 - working capacity of chamber can be smaller 2 - additional internal glass door forced 68/68 68/68/68 150/150 150/200 150/250 200/200 294/294 2,4/2,4 2,4/2,4/2,4 5,2/5,2 5,2/7,0 5,2/8,5 7,0/7,0 10,3/10,3 550 1170 650 470 430 300 2 solid / glass or double (option) 0...+10 / -10...+10 (option only for CHL 350/350) +32...+50 / +14...+50 (option only for CHL 350/350) microprocessor with external LCD graphic display aluminum / stainless steel powder coated sheet / stainless steel linen finish INOX/G or polished INOX/S 550 600 600 600 600 720 1740 1670 1870 2070 2070 2025 650 600 600 600 600 860 470 520 520 520 520 600 430 660 660/860 660/1060 860 700 300 420 420 420 420 700 10 10 10 10 10 10 30 20/20 20/20/20 30/30 30/40 30/50 40/40 75/75 320 480 350 350 350 350 800 65 100 100 105 110 115 162 every 0,1 ±0,2 ±0,2 ±0,3 ±0,3 ±0,3 ±0,3 ±0,5 class 1.0 according to DIN 12880 / class 3.2 (option) 110-120/220-240 2/2 2/2 3/4 3/4 3/4 3/4 2/6 24 months POL-EKO-APARATURA 3 - dims of units with double door can be smaller 4 - fluctuation measured in centre of the chamber 5 - "fitted number of shelves fitted, included in price 6 - "max" number of shelves which can be fitted